PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Repeatability and Reproducibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Human Fc gamma receptors: stable inter-donor variation in quantitative expression on platelets correlates with functional responses.

Evidence has recently been presented that a 40,000 dalton membrane sialoglycoprotein (p40) shared by monocytes and granulocytes serves as the human platelet receptor for aggregated IgG. We now report that the platelets of normal donors exhibit stable quantitative differences in the expression of this receptor molecule, as determined by flow cytometry using fluorescent staining with murine monoclonal antibody to p40 (mab IV.3). These inter-donor differences were reproducible on repeated testing over at least 4 mo. In concurrent assays, the binding of mab IV.3 to each donor's platelets was highly correlated with the binding of heat-aggregated human IgG, also assayed by flow cytometry. The biological relevance of this quantitative variation in IV.3 binding is suggested by its reproducible correlation with platelet responsiveness to aggregated IgG measured by aggregometry. Such stable quantitative variation in platelet Fc receptor expression among individual humans could contribute to differences in severity of certain pathologic processes initiated by IgG-containing immune complexes.

Antibodies, Monoclonal↗

A novel multiplexing, polymerase chain reaction-based assay for the analysis of chromosome 18q status in colorectal cancer.

Chromosome 18q allelic loss has been reported to have prognostic significance in stage II colorectal carcinoma. We have developed a fluorescent multiplex polymerase chain reaction assay to analyze five microsatellite markers (D18S55, D18S58, D18S61, D18S64, and D18S69) for allelic loss at the long arm of chromosome 18. Amplicon detection and evaluation was accomplished by capillary electrophoresis using an ABI 310 genetic analyzer. Robustness of the assay when performed on DNA extracted from formalin-fixed, paraffin-embedded tissue sections was confirmed by analyzing its repeatability and reproducibility. Allelic loss was assessed in 61 stage II colorectal tumors and was detected in 58% (31 of 53) of tumors not showing instability. As part of the study, results of 207 previous polymerase chain reaction/polyacrylamide-based assays were re-evaluated by two independent observers to determine the degree of concordance of visual evaluation. In the case of stage II colorectal tumors, when electropherogram results were compared with those obtained from visual evaluation of the same markers after polyacrylamide gel electrophoresis, discrepancies between observers were detected in 16.4% of determinations. In conclusion, we have developed a robust and reliable assay for multiplexed loss of heterozygosity determination that improves assessment of chromosome 18q allelic loss in colorectal tumors processed as routine formalin-fixed, paraffin-embedded specimens.

Adult↗

Effects of diltiazem on in vitro cardiovascular actions of crude venom obtained from Okinawan box-jellyfish (Habu-kurage), Chiropsalmus quadrigatus.

The venom obtained from Okinawan box-jellyfish (Habu-kurage), Chiropsalmus quadrigatus, produced increases in contractions of isolated rat right atrial preparations in a concentration-dependent manner without changes in a spontaneous beating rate. These increases in contractions were significantly inhibited by diltiazem and did not show tachyphylaxis. The venom also produced increases in contractions of isolated rat aortic ring preparations (endothelium-intact) in a concentration-dependent fashion, which were reproducible with repeated application and were significantly inhibited by diltiazem or heating. These increases in vascular contractions were weakened in endothelium-denuded preparations, and almost abolished in a calcium-free medium. On the other hand, the venom at higher concentrations diminished contractions of both myocardial and vascular preparations and did not show reproducibility. These results suggest that the Habu-kurage venom is heat-labile and may increase contractions of cardiac muscle and aortic smooth muscle by increasing calcium influx into muscle cells, and that the venom at higher concentrations may produce dysfunction of muscle contractile systems due to calcium overload.

Animals↗

The Fowler breathholding study revisited: continuous rating of respiratory sensation.

The respiratory distress of breathholding has been shown to be relieved by breathing, even without correction of worsening blood gases (Fowler, 1954). We repeated the study by having untrained normal subjects perform maximal breathholds which were followed by the rebreathing of a gas mixture containing 7.5% CO2 and 8.2% O2, and then by second breathholds. In addition, we had the subjects continuously rate their respiratory distress using a visual analog scale (VAS). The ratings were easy to perform and were highly reproducible on repeated trials in a given subject. Subjects experienced increasing distress during the breathhold, rapid and substantial relief upon rebreathing, and then were capable of performing second breathholds, all consistent with Fowler's results. The findings are consistent with animal studies in which a neural mechanism associated with stimulation of pulmonary stretch receptors inhibits the firing of midbrain neurons which may be involved in transmission to the cortex of sensory information about breathing.

Adult↗

Application of interhemispheric index for transcranial Doppler sonography velocity measurements and evaluation of recording time.

BACKGROUND AND PURPOSE: To validate the reliability of transcranial Doppler sonography velocity measurements in clinical settings, assessment of the reproducibility of repeated bilateral simultaneous measurements and the optimal recording time is needed. Our hypothesis was that interhemispheric indices would prove more valid than the absolute velocity measurements usually applied. The potential interference between ultrasound beams in bilateral samplings also needs evaluation. METHODS: Thirty healthy volunteers were studied at rest within hours or with a 2-month interval between measurements. Absolute blood flow velocities and side-to-side indices between velocities obtained in the middle cerebral arteries were measured over a 30-second period by two independent examiners. The correlation coefficient (r) and the coefficients of variation of the difference between either absolute velocities (CV) or indices (CVi) were calculated. The beat-to-beat variation of the diastolic, systolic, and mean velocities was also recorded. For evaluation of ultrasound beam interference, measurements were performed with and without one probe unplugged. RESULTS: In the interobserver study in which measurements were repeated within hours, r = .92, CV = 8.8%, and CVi = 4.1%. In the intraobserver study in which measurements were repeated with a 2-month interval, r = .8, CV = 13.0%, and CVi = 7.3%. A recording time of 30 seconds reduced CVi to 2.6%, whereas for absolute velocities 5-second recordings produced an acceptable variation. There was no significant interference between bilaterally placed probes. CONCLUSIONS: The introduction of interhemispheric indices improve interobserver and intraobserver reproducibility by approximately 50%. We recommend use of the index in clinical settings in which unilateral velocity changes are expected. For measurement of an interhemispheric index, a recording time of 30 seconds is recommended, whereas 5-second measurement periods yield a sufficient estimate of absolute velocities.

Adult↗

Development of quantification software using model-based segmentation of left ventricular myocardium in gated myocardial SPECT.

Gated myocardial single photon emission computed tomography (SPECT) is being used for the diagnosis of coronary artery diseases. In this study, we developed new software for the quantification of volumes and ejection fraction (EF) on the gated myocardial SPECT data using a cylindrical model. Volumes and EF by developed software were validated by comparing with those quantified by quantitative gated SPECT (QGS) software. Cylinder model for left ventricular myocardium was used to eliminate background activity and count profiles across the myocardium were fitted to the Gaussian curve to determine the endocardial and epicardial boundary. End-diastolic volume (EDV), end-systolic volume (ESV) and EF were calculated using this boundary information. Gated myocardial SPECT was performed in 83 patients. EDV, ESV and EF values estimated using present method were compared to those obtained using the commercialized software QGS, and reproducibility in the parameter estimation was assessed. EF, EDV and ESV obtained using two methods were correlated well (correlation coefficients = 0.96, 0.96 and 0.98). The correlation between the parameters repetitively estimated from the same data set by an operator was very high (correlation coefficients = 0.96, 0.99 and 0.99 for EF, EDV and ESV). On the repeated acquisition, reproducibility was also high with correlation coefficients of 0.89, 0.97 and 0.98. The present software will be useful for the development of new parameters for describing the perfusion and function of the LV.

Aged↗

Evaluation of performance of four genotypic methods for studying the genetic epidemiology of Aspergillus fumigatus isolates.

In the present investigation, 49 Aspergillus fumigatus isolates obtained from four nosocomial outbreaks were typed by Afut1 restriction fragment length polymorphism (RFLP) analysis and three PCR-based molecular typing methods: random amplified polymorphic DNA (RAPD) analysis, sequence-specific DNA primer (SSDP) analysis, and polymorphic microsatellite markers (PMM) analysis. The typing methods were evaluated with respect to discriminatory power (D), reproducibility, typeability, ease of use, and ease of interpretation to determine their performance and utility for outbreak and surveillance investigations. Afut1 RFLP analysis detected 40 types. Thirty types were observed by RAPD analysis. PMM analysis detected 39 allelic types, but SSDP analysis detected only 14 types. All four methods demonstrated 100% typeability. PMM and RFLP analyses had comparable high degrees of discriminatory power (D = 0.989 and 0.988, respectively). The discriminatory power of RAPD analysis was slightly lower (D = 0.971), whereas SSDP analysis had the lowest discriminatory power (D = 0.889). Overall, SSDP analysis was the easiest method to interpret and perform. The profiles obtained by PMM analysis were easier to interpret than those obtained by RFLP or RAPD analysis. Bands that differed in staining intensity or that were of low intensity were observed by RAPD analysis, making interpretation more difficult. The reproducibilities with repeated runs of the same DNA preparation or with different DNA preparations of the same strain were high for all the methods. A high degree of genetic variation was observed in the test population, but isolates were not always similarly divided by each method. Interpretation of band profiles requires understanding of the molecular mechanisms responsible for genetic alternations. PMM analysis and Afut1 RFLP analysis, or their combination, appear to provide the best overall discriminatory power, reproducibility, ease of interpretation, and ease of use. This investigation will aid in planning epidemiologic and surveillance studies of A. fumigatus.

Aspergillosis↗

Postmortem assessment of fetal diaphyseal femoral length: validation of a radiographic methodology.

Depending on the general condition of fetal remains, forensic specialists might face difficulties concerning age estimation. Reference tables and regression equations are helpful devices in this task, although they are generally applied for complete fetuses or fetal remains including soft tissues. However, the problem of age estimation stays for osseous remains, both for entire bones and ossified parts, since most of the reference tables come from ultrasonographic measurements, which are not easily reproducible on fetal osseous remains. Furthermore, the ultrasonographic measurements contain slight errors in comparison to the real anatomical ones. This study describes a radiographic protocol and a measurement technique that facilitate and improve bone measurements, and therefore, facilitate age estimation, too. A qualitative criterion, namely a clear-cut bony endplate, was defined and tested. Its reliability (repeatability and reproducibility) turned out to be good, showing nonsignificative differences to the threshold of 0.05, with average errors of 0.26 and 0.44 mm respectively. Moreover, concerning the test of eventual size differences between the right and left femurs showed a P value < 0.0001. The test of the qualitative criterion was based on the comparison of the radiographic in situ femur measurements and the radiographic measurements of the same bones after dissection. The results were satisfactory, since an average error of 0.58 mm was obtained, which did not give any significant differences to the threshold of 0.05. It was concluded that this methodology provides an easy and precise new measurement tool for forensic practice, and can allow us to establish some nonultrasonographic tables, which fit our population.

Age Determination by Skeleton↗

Measurement of inotropic effects by a newly developed guinea pig papillary muscle bioassay.

In order to measure inotropic influences of physiologically occurring substances and drugs we used a newly developed guinea pig papillary muscle (GPPM) bioassay. GPPM were suspended in air and surface coated with buffer (Krebs-Henseleit solution). The muscles were stimulated (pulsating direct current, 1.5 V; 0.5 Hz, 20 ms duration) which led to contraction. This method enables measurements of inotropic effects up to 5 days, contrary to previous studies (1 day), in which immersions of GPPM in buffer were performed. In order to investigate the comparability of the new method we measured the effect of metabolites (citric acid cycle), lactic acid, lactate, and extracellular pH on muscle contractility. The H(+)-dependent decrease of the contractile force of the GPPM can be compensated by an increased Ca(2+)-concentration. Further, the influence of catecholamines (isoproterenol) on the contractility was investigated. As a result, isoproterenol caused arrhythmias and extrasystoles as it was observed in clinical studies. Several pharmaceutical substances were tested to show the reproducibility and repeatability of the bioassay.

Acid-Base Equilibrium↗

Determination of fumonisins B1 and B2 in corn and corn flakes by liquid chromatography with immunoaffinity column cleanup: collaborative study.

A liquid chromatographic (LC) method for the determination of fumonisins B1 (FB1) and B2 (FB2) in corn and corn flakes was collaboratively studied by 23 laboratories, which analyzed 5 blind duplicate pairs of each matrix to establish the accuracy, repeatability, and reproducibility characteristics of the method. Fumonisin levels in the corn ranged from <0.05 (blank) to 1.41 microg/g for FB1 and from <0.05 to 0.56 microg/g for FB2, whereas in the corn flakes they ranged from <0.05 to 1.05 microg/g for FB1 and from <0.05 to 0.46 microg/g for FB2. The method involved double extraction with acetonitrile-methanol-water (25 + 25 + 50), cleanup through an immunoaffinity column, and LC determination of the fumonisins after derivatization with o-phthaldialdehyde. Relative standard deviations for the within-laboratory repeatability (RSDr) of the corn analyses ranged from 19 to 24% for FB1 and from 19 to 27% for FB2; for the corn flakes analyses, RSDr ranged from 9 to 21 % for FB1 and from 8 to 22% for FB2. Relative standard deviations for the between-laboratories reproducibility (RSDR) of the corn analyses ranged from 22 to 28% for FB1 and from 22 to 30% for the FB2; for corn flakes analyses, RSDR ranged from 27 to 32% for FB1 and from 26 to 35% for FB2. Mean recoveries of FB1 and FB2 from corn spiked with FB1 at 0.80 microg/g and with FB2 at 0.40 microg/g were 76 and 72%, respectively; for corn flakes spiked at the same levels recoveries were 110 and 97% for FB1 and FB2, respectively. HORRAT ratios for the analyses of corn ranged from 1.44 to 1.53 for FB1 and from 0.96 to 1.48 for FB2, whereas for corn flakes they ranged from 1.60 to 1.82 for FB1 and from 1.39 to 1.68 for FB2.

Carboxylic Acids↗

Are heart rate responses reproducible in the tilt-table test?

Measurement of blood pressure and heart rate in active orthostasis has proven to be effective in the diagnosis of autonomic regulatory dysfunctions. The following study was carried out in order to clarify to what extent reproducible heart rate reactions also occur in passive orthostasis. 61 people with normal results in five standardized tests were examined. All 61 test persons had individually differing courses of heart rate. After an initial increase of frequency an almost straight line results from a superimposed projection of the graphs. In 20 of these cases the tilt-table test was repeated in order to detect intra-individual regularities. Even when the test was repeated, no reproducible intraindividual heart rate reactions occurred. And here as well, projection of the graphs produced an almost straight line. We could not find any quotient, such as the 30/15 ratio in active orthostasis, during our tests with the tilt-table.

Adult↗

Repeated micro-monocyte adherence inhibition assay: a new technique of leukocyte adherence inhibition to detect tumor immunity in patients with hepatoma.

A microplate leukocyte adherence inhibition (micro-LAI) assay was performed with peripheral blood mononuclear cells obtained from patients with hepatoma and control subjects (including healthy donors and patients with other diseases). Cell extracts of human hepatoma cells (HCC-M) and human hepatic cells (Chang liver cell) in tissue culture were prepared by sonication followed by centrifugation. The supernatants of these two cell lines were used as a specific antigen and a nonspecific antigen, respectively. It was found that monocytes were major indicator cells and that monocytes produced an LAI reaction in the absence of lymphocytes. Therefore, a repeated microplate monocyte adherence inhibition (MAI) assay was developed, in which the monocyte population of adherent cells is increased by removing nonadherent cells after an initial assay in fetal calf serum-containing medium without test antigens, and monocytes are counted selectively as peroxidase-positive cells in a subsequent second assay with test antigens. With regard to sensitivity and reproducibility, the repeated micro-MAI assay is superior to a micro-MAI assay in which the initial assay is omitted although monocytes are selectively counted. With this simple and sensitive technique a hepatoma-associated immune response to the extract of HCC-M was detected in 16 out of 22 patients (73%) with hepatoma, whereas the false-positive rate was 7% (3/41) in all control subjects.

Carcinoma, Hepatocellular↗

Repeatability of cough-related variables during fog challenges at threshold and suprathreshold stimulus intensity in humans.

Cough-related variables such as cough frequency, time to onset (i.e. the time until the first cough occurs) and the cough index (i.e. the ratio between the cough frequency and the time to onset) may be important when interpreting results of cough challenges for therapeutic interventions or for comparative research purposes. Nevertheless, repeatability (or reproducibility) for these widely used variables has been poorly studied. In thirty normal subjects, coughing was induced by inhalation of threshold (T) and suprathreshold (1.6 x T) concentrations of ultrasonically nebulized distilled water (fog). Cough threshold was taken as the lowest fog concentration that evoked at least one cough effort during two challenges separated by a 30-min interval. During challenges performed at both threshold and suprathreshold stimulus intensity, cough frequency, time to onset, and the cough index were assessed; within-subject repeatability for these variables was subsequently evaluated. Median +/- interquartile range cough threshold value was 0.9+/-0.5 mL x min(-1). During the two challenges performed to assess cough threshold, the mean +/-SD values of cough frequency, time to onset, and cough index were similar (5.0+/-2.7 and 5.3+/-3.1 coughs x min(-1), 32.4+/-13.3 and 32.9+/-13.6 s, and 0.2+/-0.2 and 0.2+/-0.2, respectively). However, none of these cough-related variables proved to be sufficiently repeatable. During the two challenges performed at suprathreshold stimulus intensity, mean values of cough frequency, time to onset, and cough index were also similar (20.0+/-9.0 and 18.2+/-10.2 coughs x min(-1), 13.5+/-5.8 and 12.0+/-4.62 s, and 1.7+/-1.0 and 1.8+/-1.2); furthermore, all considered variable of suprathreshold challenge turned out to be reproducible. In conclusion, during fog challenges at threshold stimulus intensity, cough frequency, time to onset and cough index cannot reliably be used for evaluating cough responses. However, these cough-related variables may represent useful and reliable research tools in the evaluation of suprathreshold cough responses.

Adult↗

Plasma post-heparin lipase activities in the HERITAGE Family Study: the reproducibility, gender differences, and associations with lipoprotein levels. HEalth, RIsk factors, exercise Training and GEnetics.

OBJECTIVES: Examine the reproducibility of plasma lipid and lipoprotein measurements in the HERITAGE Family Study. DESIGN AND METHODS: In a sample of 379 subjects (191 men and 188 women), reproducibility was determined for lipids, lipoproteins (done on two occasions) and post-heparin lipase assays using an Intracenter Quality Control study by generating split samples from an additional 60 subjects (35 men and 25 women), which were assayed in a blind fashion by the lipid core laboratory. Reproducibility was estimated using intraclass correlation coefficients (ICC) for the selected variables. Analytical error (ANER) and coefficient of variation (CV) were also calculated. Day-to-day variation for 10 variables including plasma cholesterol and triglycerides (TG), HDL-cholesterol and its subfractions HDL2-cholesterol and HDL3-cholesterol, LDL-cholesterol and VLDL-cholesterol, as well as apoprotein (apo) A-I, apo B, and LDL-apo B were assessed. RESULTS: In the HERITAGE study, all lipid and lipoprotein variables had ICC above 0.79. Plasma VLDL-cholesterol (31 %) and TG (23%) levels, which are well known to be highly variable from one day to another, had CVs greater than 20%. Other variables had CVs lower than 10% except for HDL2-cholesterol which reached 16%. In the intracenter reliability sub-study, the measurement errors were found to be low except for HDL2-cholesterol. For the lipases, the reproducibility of repeated samples was very high, with ICC over 0.95. The within-assay CV corresponded to 2.1 and 5.3% for hepatic lipase (HL) and lipoprotein lipase (LPL), respectively, whereas the between-assay CV reached 8-12% for HL and about 15% for LPL. Due to the complexity of these two assays, the results are considered to be quite satisfactory. CONCLUSIONS: The reproducibility of plasma lipid and lipoprotein measurements, as well as of post-heparin lipase activities, is good in the multicenter HERITAGE Family Study. In addition, the well-documented gender difference in the plasma lipoprotein profile was confirmed in the present study, women having lower fasting triglyceride and LDL-cholesterol levels than men as well as reduced cholesterol/HDL-cholesterol and increased HDL2-cholesterol/ HDL3-cholesterol ratios compared to men. Results of the present study support the notion that the higher LPL and low HL activities found in women compared to men are important factors contributing to explain gender difference in the lipoprotein profile. However, additional factors not examined in the present study are involved beyond the contribution of post-heparin lipase to the sex dimorphism in plasma lipoprotein levels.

Female↗

Repeated antigen inhalation-induced reproducible early and late asthma in guinea pigs.

To develop a model of chronic experimental asthma in guinea pigs, the animal was forced to inhale the mist of a low dose of ovalbumin (OA) adsorbed on fine Al(OH)3 for sensitization once every 4 weeks. The animal was challenged by inhalation with the mist of OA on day 14 after the respective sensitizations. Either the first or the second antigen challenge markedly induced an early asthmatic response (EAR), whereas there was hardly any late asthmatic response (LAR). At the 3rd challenge, LAR also emerged with some severity. These dual responses were consistently observed until the 10th challenge. On the other hand, repeated inhalation/challenge, once every 2 weeks, with OA alone at the same dose tended to lead to the desensitization of the EAR. In addition, LAR was hardly observed throughout the experiments. In both groups, gamma 1 and IgE levels in the serum were elevated by the repetitive antigen inhalations, yet no obvious relationship between these antibody levels and the intensity of either EAR or LAR was recognized. The present results indicate that the asthmatic model with reproducible EAR and LAR developed in this study appears to be very beneficial for the investigation of bronchial asthma and for the assessment of anti-asthma drugs.

Administration, Inhalation↗

Use of a new alginate film test to study the bactericidal efficacy of the high-level disinfectant ortho-phthalaldehyde.

OBJECTIVES: To evaluate the merit of a new alginate efficacy film test to determine the bactericidal activity of the high-level disinfectant ortho-phthalaldehyde (OPA). METHODS: The efficacy of OPA was investigated using a new sodium alginate surface film test against Mycobacterium chelonae NCIMB 1474 and Epping, and Pseudomonas aeruginosa NCIMB 10421 under different test conditions. RESULTS: OPA was highly bactericidal against P. aeruginosa but its mycobactericidal efficacy was seriously reduced and produced >or=5 log reductions only at a concentration of 0.5% (w/v) within 30-60 min without organic load. CONCLUSIONS: The sodium alginate film efficacy was reproducible between repeats. Inactivation results depended upon the concentration of OPA, contact time, the presence of an organic load and the bacterial genera.

Alginates↗

Reliability and sensitivity of diagnostic tests for primary Sjögren's syndrome.

OBJECTIVE: To investigate whether diagnostic tests for primary Sjögren's syndrome (pSS) are reproducible when repeated after one year (reliability). To evaluate whether the sensitivity of the diagnostic tests increases with repeated testing. METHODS: A structured interview investigating the subjective sensation of dry eyes and dry mouth, and the diagnostic tests Schirmer I, unstimulated whole saliva collection (UWSC), serological tests for antinuclear antibodies (ANA), for anti-Ro/SSA and anti-La/SSB antibodies as well as Waaler's test for rheumatoid factor, were performed twice with a one year interval in 66 patients with pSS. Reliability was given as the percentage of positive tests remaining positive at the second examination, while sensitivity was given as the percentage of patients with positive tests. RESULTS: Highest reliability was obtained for the sensation of dry mouth (98.2%) and sensation of dry eyes (96.4%), and anti-SSA/SSB antibodies (93.3%). Lowest reliability was obtained for rheumatoid factor at cutoff titer 1:32 (70.6%) and positive Schirmer I in one eye (77.4%). The reliability for ANA was 80% at cutoff titer 1:32, and increased to 93.3% at cutoff titer 1:128. UWSC had a reliability of 84.2%. The pooled sensitivity for all the tests increased significantly (p < 0.05) compared to the examination, which had the lowest sensitivity. CONCLUSION: The diagnostic tests for pSS are generally highly reliable when performed twice with a one year interval. The gain in sensitivity by repeating the tests is limited, being most marked for Schirmer I.

Adult↗

Freeze-dried mixed cultures as reference samples in quantitative and qualitative microbiological examinations of food.

Two simulated food samples in the form of mixtures of bacteria, freeze-dried in small glass vials, were tested for their suitability as reference materials in food microbiology. Stability and homogeneity of the samples were assessed during a 1 year period when stored at 2-6 degrees C. Samples were examined for aerobic plate counts, coliform counts, Staphylococcus aureus, Clostridium perfringens, Bacillus cereus, enterococci, yeasts and salmonellas. The samples were homogeneous but the number of colony forming units of some organisms declined during the time period studied. The maximum rate of decline (0.8 log units per year) was observed for the coliforms. Precision estimates (reproducibility and repeatability) for the different testing methods used are given. When compared with these data, the rate of decline was considered to be of less importance.

Analysis of Variance↗