PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 361 records · Page 20Linked to original sources

Linking biosensor responses to Cd, Cu and Zn partitioning in soils.

Soils bind heavy metals according to fundamental physico-chemical parameters. Bioassays, using bacterial biosensors, were performed in pore waters extracted from 19 contrasting soils individually amended with Cd, Cu and Zn concentrations related to the EU Sewage Sludge Directive. The biosensors were responsive to pore waters extracted from Zn amended soils but less so to those of Cu and showed no toxicity to pore water Cd at these environmentally relevant amended concentrations. Across the range of soils, the solid-solution heavy metal partitioning coefficient (K(d)) decreased (p<0.01) with increasing amendments of Cu and Zn; Cu exhibited the highest K(d) values. Gompertz functions of Cu and Zn, K(d) values against luminescence explained the relationship between heavy metals and biosensors. Consequently, biosensors provide a link between biologically defined hazard assessments of metals and standard soil-metal physico-chemical parameters for determining critical metal loadings in soils.

Biosensing Techniques↗

Detection of egg yolk antibodies reflecting Salmonella enteritidis infections using a surface plasmon resonance biosensor.

A surface plasmon resonance (SPR) biosensor assay was developed on the basis of a lipopolysaccharide antigen of Salmonella enterica serovar enteritidis (S. enterica serovar enteritidis) to detect egg yolk antibodies against S. enterica serovar enteritidis. This biosensor assay was compared to two commercial ELISA kits based on LPS antigen and flagellar antigen. A number of 163 egg yolk and combined egg white and yolk samples from chickens experimentally infected with S. enterica serovar enteritidis and 90 egg yolk and combined egg white and yolk samples from uninfected chickens were analyzed. Receiver operating characteristic analysis of the data calculated a diagnostic sensitivity of 82% and a diagnostic specificity of 100%. The within-day coefficient of variation of a positive internal-control egg yolk was 1%. The SPR biosensor assay was able to detect antibodies in a significantly higher percentage of known positive samples than the commercial ELISA's. The anticipated use of the SPR biosensor assay is to determine the S. enterica serovar enteritidis serostatus of non-vaccinated layer hens.

Animals↗

Development of a biosensor based on gilo peroxidase immobilized on chitosan chemically crosslinked with epichlorohydrin for determination of rutin.

A new reagentless biosensor for the square-wave voltammetric determination of rutin in pharmaceutical formulations was developed by immobilization of gilo (Solanum gilo) crude extract in chitosan matrix. The gilo tissue acts as a source of peroxidase. The highest biosensor performance was obtained after immobilization of the peroxidase in chemically crosslinked chitosan with epichlorohydrin and glutaraldehyde that was incorporated in a carbon paste electrode. In the presence of hydrogen peroxide this enzyme catalyses the oxidation of rutin to quinone and the electrochemical reduction of the product was obtained at a fixed potential of +124 mV versus Ag/AgCl (3.0 M KCl). The performance and factors influencing the resulting biosensor were studied in detail. The bioelectrode exhibited a linear response for rutin concentrations from 3.4x10(-7) to 7.2x10(-6) M (r=0.9998) and the recovery of rutin from the samples ranged from 96.2 to 102.4%. The detection and quantification limits were 2.0x10(-8) and 6.3x10(-8) M, respectively. The relative standard deviation was less than 1.0% for solutions containing 3.4x10(-7) to 7.2x10(-6) M rutin in 0.1 M phosphate buffer solution at pH 7.0 (n=10). The lifetime of this biosensor was 8 months (at least 500 determinations).

Benzoquinones↗

Novel biosensors for the detection of estrogen receptor ligands.

There exists a significant need for the detection of novel estrogen receptor (ER) ligands for pharmaceutical uses, especially for treating complications associated with menopause. We have developed fluorescence resonance energy transfer (FRET)-based biosensors that permit the direct in vitro detection of ER ligands. These biosensors contain an ER ligand-binding domain (LBD) flanked by the FRET donor fluorophore, cyan fluorescent protein (CFP), and the acceptor fluorophore, yellow fluorescent protein (YFP). The ER-LBD has been modified so that Ala 430 has been changed to Asp, which increases the magnitude of the FRET signal in response to ligand-binding by more than four-fold compared to the wild-type LBD. The binding of agonists can be distinguished from that of antagonists on the basis of the distinct ligand-induced conformations in the ER-LBD. The approach to binding equilibrium occurs within 30min, and the FRET signal is stable over 24h. The biosensor demonstrates a high signal-to-noise, with a Z' value (a statistical determinant of assay quality) of 0.72. The affinity of the ER for different ligands can be determined using a modified version of the biosensor in which a truncated YFP and an enhanced CFP are used. Thus, we have developed platforms for high-throughput screens for the identification of novel estrogen receptor ligands. Moreover, we have demonstrated that this FRET technology can be applied to other nuclear receptors, such as the androgen receptor.

Androgens↗

Capture and reconstitution of G protein-coupled receptors on a biosensor surface.

Surface plasmon resonance (SPR) biosensors offer a unique opportunity to study the binding activity of G protein-coupled receptors (GPCRs) in real time with minimal sample preparation. Using two chemokine receptors (CXCR4 and CCR5) as model systems, we captured the proteins from crude cell preparations onto the biosensor surface and reconstituted a lipid environment to maintain receptor activity. The conformational states of the receptors were probed using conformationally dependent antibodies, and by characterizing the binding properties of a native chemokine ligand (stromal cell-derived factor 1alpha). The results suggest that the detergent-solubilized receptors are active for ligand binding in the presence and absence of a reconstituted bilayer. There are three advantages to using this receptor-capturing approach: (1) there is no need to purify the receptor prior to immobilization on the biosensor surface, (2) the receptors are homogeneously immobilized through the capturing step, and (3) the receptors can be captured at high enough densities to allow the study of relatively low-molecular-mass ligands (2000-4000Da). We also demonstrated that the receptors are sensitive to the solubilizing conditions, which illustrates the potential for using SPR biosensors to rapidly screen solublization conditions for GPCRs.

Antibodies, Monoclonal↗

Biosensors in clinical chemistry.

Biosensors are analytical devices composed of a recognition element of biological origin and a physico-chemical transducer. The biological element is capable of sensing the presence, activity or concentration of a chemical analyte in solution. The sensing takes place either as a binding event or a biocatalytical event. These interactions produce a measurable change in a solution property, which the transducer converts into a quantifiable electrical signal. Present-day applications of biosensors to clinical chemistry are reviewed, including basic and applied research, commercial applications and fabrication techniques. Recognition elements include enzymes as biocatalytic recognition elements and immunoagents and DNA segments as affinity ligand recognition elements, coupled to electrochemical and optical modes of transduction. The future will include biosensors based on synthetic recognition elements to allow broad applicability to different classes of analytes and modes of transduction extending lower limits of sensitivity. Microfabrication will permit biosensors to be constructed as arrays and incorporated into lab-on-a-chip devices.

Biosensing Techniques↗

Capillary electrophoresis coupled to biosensor detection.

The present review highlights some modern aspects of biosensor revelation, a detection method which has already found a large number of applications in healthcare, food industry and environmental analysis. First, the concept of bio-recognition, which is at the heart of biosensor technology, is discussed, with emphasis on host-guest-like recognition mechanisms. This detection device has been successfully coupled, in its first applications, to chromatographic columns, which allow a high resolution of complex mixtures of analytes prior to interaction with the biosensing unit. The properties of the transducing elements, which should generate a signal (e.g., electrochemical, thermal, acoustic, optical) of proper intensity and of relative fast rise, are additionally evaluated and discussed. The review then focuses on potential applications of biosensing units in capillary electrophoresis (CE) devices. CE appears to be an excellent separation methodology to be coupled to biosensor detection, since it is based on miniaturized electrophoretic chambers, fast analysis times, complete automation in sample handling and data treatment and requires extremely small sample volumes. Although only a few applications of CE-based biosensors have been described up to the present, it is anticipated that this hyphenated technique could have a considerable expansion in the coming years.

Biosensing Techniques↗

Use of bacterial biosensors to interpret the toxicity and mixture toxicity of herbicides in freshwater.

The dose response relationship between seven commonly used herbicides and four luminescence-based bacterial biosensors was characterised. As herbicide concentration increased the light emitted by the test organism declined in a concentration dependent manner. These dose responses were used to compare the predicted vs. observed response of a biosensor in the presence of multiple contaminants. For the majority of herbicide interactions, the relationship was not additive but primarily antagonistic and sometimes synergistic. These biosensors provide a sensitive test and are able to screen a large volume and wide range of samples with relative rapidity and ease of interpretation. In this study biosensor technology has been successfully applied to interpret the interactive effects of herbicides in freshwater environments.

Bacteria↗

Monitoring of dihydroxyacetone production during oxidation of glycerol by immobilized Gluconobacter oxydans cells with an enzyme biosensor.

A bi-enzymatic biosensor for monitoring of dihydroxyacetone production during oxidation of glycerol by bacterial cells of Gluconobacter oxydans is presented. Galactose oxidase oxidizes dihydroxyacetone efficiently producing hydrogen peroxide, which reacts with co-immobilized peroxidase and ferrocene pre-adsorbed on graphite electrode. This mediator-based bi-enzymatic biosensor possesses very high sensitivity (4.7 µA/mM in phosphate buffer), low detection limit (0.8 µM, signal/noise = 3), short response time (22 s, 95% of steady-state) and broad linear range (0.002-0.55 mM in phosphate buffer). The effect of pH, temperature, type of buffer, as well as different stabilizers (combinations of a polyelectrolyte and a polyol) on the sensor performance were carefully optimized and discussed. Dihydroxyacetone produced during a batch conversion of glycerol by the pectate-immobilized bacteria in an air-lift reactor was determined by the biosensor and by reference spectrophotometric method. Both methods were compared and were in a very good correlation. The main advantage of the biosensor is a very short time needed for sample analysis (less than 1 min).

Journal Article↗

An amperometric glucose-oxidase/poly(o-phenylenediamine) biosensor for monitoring brain extracellular glucose: in vivo characterisation in the striatum of freely-moving rats.

Amperometric glucose biosensors based on the immobilization of glucose oxidase (GOx) on Pt electrodes with electropolymerized o-phenylenediamine (PPD) were implanted in the right striatum of freely-moving rats. Carbon paste electrodes for the simultaneous monitoring of ascorbic acid (AA) and/or tissue O2 were implanted in the left striatum. A detailed in vivo characterization of the Pt/PPD/GOx signal was carried out using various pharmacological manipulations. Confirmation that the biosensor responded to changing glucose levels in brain extracellular fluid (ECF) was obtained by intraperitoneal (i.p.) injection of insulin that caused a decrease in the Pt/PPD/GOx current, and local administration of glucose (1 mM) via an adjacent microdialysis probe that resulted in an increase in the biosensor current. An insulin induced increase in tissue O2 in the brain was also observed. Interference studies involved administering AA and subanaesthetic doses of ketamine i.p. Both resulted in increased extracellular AA levels with ketamine also causing an increase in O2. No significant change in the Pt/PPD/GOx current was observed in either case indicating that changes in O2 and AA, the principal endogenous interferents, have minimal effect on the response of these first generation biosensors. Stability tests over a successive 5-day period revealed no significant change in sensitivity. These in vivo results suggest reliable glucose monitoring in brain ECF.

Animals↗

Biosensors in the livestock industry: an automated ovulation prediction system for dairy cows.

Biosensor technology can offer the livestock industry new types of monitoring and measuring devices of which the specificity, sensitivity, reproducibility, speed and ease of use exceed the current technology. Biosensors can be applied to the detection and identification of infectious diseases in livestock, contaminants and toxins in feed, therapeutic drug residues in animal husbandry and oestrus detection. Our team is applying biosensor technology to the livestock industry by developing a fully automated ovulation prediction system for dairy cows. The results from field-tests show that the progesterone biosensor can characterize the ovulation cycles of cows and detect pregnancy.

Animals↗

Real time biosensor analysis of staphylococcal enterotoxin A in food.

Currently there is no 'real-time' detection system to identify food borne toxins. In order to develop such a system, we have used a evanescent wave biosensor for real time detection of staphylococcal enterotoxin A (SEA) in foods. The approach used here is sandwich biosensor, a method utilizing two antibodies. The toxin binds initially to a capturing antibody which is bound covalently on the surface of the biosensor detector. The second antibody binds to the captured toxin. We were able to measure SEA in foods with little or no background interference, demonstrating that biosensor-based measurement of SEA was possible not only with purified SEA but also in complex food matrices such as hot dogs, potato salad, milk and mushrooms. Autoclaved samples of SEA did not evoke a positive response. With both purified SEA and SEA-spiked foods, the assay sensitivity is 10-100 ng/g depending on the material tested and the assay is rapid ( <4 min) when a single antibody is used.

Animals↗

A single-fractal analysis of cellular analyte-receptor binding kinetics utilizing biosensors.

A fractal analysis of a confirmative nature only is presented for cellular analyte-receptor binding kinetics utilizing biosensors. Data taken from the literature can be modeled by using a single-fractal analysis. Relationships are presented for the binding rate coefficient as a function of the fractal dimension and for the analyte concentration in solution. In general, the binding rate coefficient is rather sensitive to the degree of heterogeneity that exists on the biosensor surface. It is of interest to note that examples are presented where the binding coefficient, k exhibits an increase as the fractal dimension (D(f)) or the degree of heterogeneity increases on the surface. The predictive relationships presented provide further physical insights into the binding reactions occurring on the surface. These should assist in understanding the cellular binding reaction occurring on surfaces, even though the analysis presented is for the cases where the cellular "receptor" is actually immobilized on a biosensor or other surface. The analysis suggests possible modulations of cell surfaces in desired directions to help manipulate the binding rate coefficient (or affinity). In general, the technique presented is applicable for the most part to other reactions occurring on different types of biosensor or other surfaces.

Animals↗

Potential of biosensor technology for the characterization of interactions by quantitative affinity chromatography.

This review places the characterization of interactions by biosensor technology in the broader context of their study by quantitative affinity chromatography. The general reluctance to consider biosensor-based characterization as a form of quantitative affinity chromatography on the grounds of a difference in aims of the two techniques reflects a mistaken belief that BIAcore and IAsys studies characterize the kinetics of the chemical reaction responsible for biospecific adsorption of a soluble reactant to an immobilized form of its affinity partner. It now transpires that the association and dissociation rate constants thereby determined refer to thermodynamic characterization of biospecific adsorption in terms of a single-phase model in which affinity sites are distributed uniformly throughout the liquid-phase volume accessible to the partitioning reactant--the model used for characterization of biospecific adsorption by quantitative affinity chromatography. In that light the most important attribute of biosensor technology is its potential for thermodynamic characterization of biospecific adsorption by virtue of its ability to monitor complex formation directly; and hence its potential for the characterization of interactions with affinities that are too strong for study by forms of quantitative affinity chromatography that monitor complex formation on the basis of reactant depletion from the liquid phase. Kinetic as well as thermodynamic analyses of biosensor data are described for attainment of that potential.

Biosensing Techniques↗

Rapid screening of small ligand affinity to human serum albumin by an optical biosensor.

Here we report the use of IAsys biosensor technology for determining the binding parameters of low molecular weight compounds, such as warfarin and bilirubin, to surface immobilized human serum albumin. The protein was covalently immobilized on the surface of the biosensor cuvette, bearing a carboxymethyl dextran layer, through a condensing reaction between the carboxyl groups of the biosensor surface and epsilon-amine groups of protein lysine residues. This system detects and quantifies the changes in refractive index in the vicinity of the surface of the sensor chip to which the protein is immobilized. The changes in the refractive index are proportional to the change in the absorbed mass, thus the analysis allows the monitoring of the interaction process and the determination of the binding parameters. Optical biosensor analysis, most suited for studying protein/protein or protein/nucleic acid interactions, was sensitive enough to monitor the binding of low molecular weight compounds to human serum albumin and then suitable for a rapid screening of libraries of potential drugs when bioavailability is the research target.

Bilirubin↗

Determination of hydrogen peroxide in disinfectant solutions using a biosensor with two antagonist enzymes.

The development and characterisation of a new biosensor for hydroperoxides is described, which is obtained by combining an oxygen gas diffusion amperometric electrode and two immobilized enzymes (peroxidase and tyrosinase) working in parallel and competing for the same substrate (catechol). The response of the biosensor to several hydroperoxides was investigated (LOD=0.5.10(-4) M for hydrogen peroxide). It was experimentally found that the biosensor is able to respond also to aqueous solutions of ionic peroxides (LOD=0.2.10(-4) M for potassium peroxidisulphate). The biosensor was applied to the determination of the hydrogen peroxide content of pharmaceutical products, i.e. aqueous disinfectant solutions (RSD% < or =0.5; recoveries by standard addition method between 96.0 and 98.5%).

Biosensing Techniques↗

Materials and techniques for electrochemical biosensor design and construction.

New developments in biosensor design are appearing at a high rate as these devices play increasingly important roles in daily life. This review aims to highlight recent developments in materials and techniques for electrochemical biosensor design and construction. Rapid growth in biomaterials, especially the availability and application of a vast range of polymers and copolymers associated with new sensing techniques have led to remarkable innovation in the design and construction of biosensors, significant improvements in sensor function and the emergence of new types of biosensor. Nevertheless, in vivo applications remain limited by functional deterioration due to surface fouling by biological components. However, new copolymers based upon biomembrane mimicry have been extensively investigated during the last two decades, raising hopes that the problems related to interactions between foreign surfaces and biological fluids and tissues may soon be solved.

Biocompatible Materials↗

Simultaneous monitoring of glucose and lactate by an interference and cross-talk free dual electrode amperometric biosensor based on electropolymerized thin films.

An interference and cross-talk free dual electrode amperometric biosensor integrated with a microdialysis sampling system is described, for simultaneous monitoring of glucose and lactate by flow injection analysis. The biosensor is based on a conventional thin layer flow-through cell equipped with a Pt dual electrode (parallel configuration). Each Pt disk was modified by a composite bilayer consisting of an electrosynthesised overoxidized polypyrrole (PPYox) anti-interference membrane covered by an enzyme entrapping gel, obtained by glutaraldehyde co-crosslinking of glucose oxidase or lactate oxidase with bovine serum albumin. The advantages of covalent immobilization techniques were coupled with the excellent interference-rejection capabilities of PPYox. Ascorbate, cysteine, urate and paracetamol produced lactate or glucose bias in the low micromolar range; their responses were, however, completely suppressed when the sample was injected through the microdialysis unit. Under these operational conditions the flow injection responses for glucose and lactate were linear up to 100 and 20 mM with typical sensitivities of 9.9 (+/- 0.1) and 7.2 (+/- 0.1) nA/mM. respectively. The shelf-lifetime of the biosensor was at least 2 months. The potential of the described biosensor was demonstrated by the simultaneous determination of lactate and glucose in untreated tomato juice samples; results were in good agreement with those of a reference method.

Animals↗