PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Bone Malalignment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Relative tibial and femoral varus as a predictor of progression of varus deformities of the lower limbs in young children.

Many young children present to pediatric orthopaedic surgeons with genu varum and mild beaking of the medial metaphysis on x-ray. Predicting whether these deformities will progress is challenging. In addition, there is no consensus as to whether these children should all be classified as having Blount disease. To avoid this latter problem, the authors included in this study all children presenting with bowed legs, regardless of diagnosis. With the aim of improving the ability to predict progression, the authors tested the hypothesis that patients with progression have more tibial than femoral varus. The authors reviewed 173 varus limbs of 98 patients younger than 4 years old. The authors determined the angular deformity in both femur and tibia by measuring the angles between their mechanical axes and the transverse axis of the knee, and determined the contribution of tibial deformity as a percentage of the total (%DT). The metaphyseal-diaphyseal angles of the tibia (MDA) were also measured to compare the value of that test with the %DT. There were 22 limbs with progressive and 141 limbs with resolving varus. Both the MDA and %DT were significantly different between groups. Tibial varus was found to exceed femoral varus in all patients with progression and also in several patients whose deformity resolved spontaneously. Although more specific and more sensitive than the MDA, the %DT is a good, but not perfect, predictor of progression. However, all patients in this series with both a %DT >50% and an MDA of 16 degrees or greater went on to progress. Using both of these tests together may therefore provide the surgeon with a reliable indicator of the children who would benefit from surgical correction.

Bone Malalignment↗

Observations on the cause of bowlegs in achondroplasia.

An analysis of 148 radiographs of the tibia during skeletal maturation in patients with achondroplasia was performed. The fibula was always longer than the tibia. The distance between the proximal tibial and fibular physis was less than normal throughout growth. The distance between the distal tibial and fibular physis was normal in childhood and became increasingly greater during growth. Tibia varus increased during growth, and there was a particular increase in distal tibia varus toward the end of growth. The altered growth characteristics of the bones suggest a formulation of cause of bowlegs in achondroplasia.

Achondroplasia↗

[Use of magnetotherapy for treatment of bone malunion in limb lengthening. Preliminary report].

Two children with bone malunion after lengthening of congenitally shortened lower leg have been presented. The crus has been elongation 8 cm by Ilizarov method in 9 years old boy and 5 cm elongation of the tibia has been achieved with the use of Bastiani method in 8 years old girl. In both cases malunion has occurred. The radiographs revealed pseudoarthrosis (the girl, 6 month after operation) and centrally located bony defect (the boy, 2 months postoperatively). In both cases pulse sinusoidal magnetic field was applied successfully with cortical bone and marrow cavity restored in 2 months.

Bone Lengthening↗

[The value of ultrasonography in monitoring limb lengthening].

The authors attempted to assess the value of ultrasound for monitoring of the new bone formation at the site of distraction in patients undergoing limb lengthening after Bastiani. Twenty patients were assessed; 12 cases of femur lengthening and 8 cases of tibia lengthening. It was found, that ultrasound allowed to detect the new bone formation visible as hyperechogenic foci as soon as 4 to 14 days postoperatively, while regular radiology showed this only 4 to 8 weeks after operation. Detection of the new bone formation at the site of lengthening permits, in authors opinion, to choose an optimal onset of distraction and its pace according to the speed of bone formation. Regular ultrasound monitoring prevents premature bone union or disintegration of the newly generated bone in case of to slow or to fast distraction respectively. In two cases sonography early demonstrated cystic changes at the location of distraction. It also permits detection of an axial displacement of the fragments of bone in every case.

Adolescent↗

Reproducibility and reliability of the anatomic axis of the lower extremity.

Two observers measured the tibiofemoral angle of 60 knees on hip-knee-ankle and anteroposterior (AP) knee radiographs and repeated the measurements 6 months later. Intraobserver reproducibility was moderate. Interobserver reliability was poor. These findings were the same irrespective of which radiograph was used during the measurement. Hence, although an AP knee radiograph was as reliable and reproducible as the hip-knee-ankle view, the radiographic tibiofemoral angle should not be considered a precise measurement.

Bone Malalignment↗

A long-term follow-up study of high tibial osteotomy for medial compartment osteoarthrosis.

OBJECTIVE: To observe the long-term outcome of high tibial osteotomy (HTO) in treating medial compartment osteoarthrosis of knees. METHODS: A retrospective study was carried out on 194 patients (215 knees) treated with HTO for medial compartment osteoarthritis at the Orthopaedic Hospital of Kiel University between 1985 and 1996. RESULTS: One hundred and sixty-one knees (144 patients) were followed up for 1.5-12 years with an average of 7.5 years and their data were reviewed. The proportion of excellent outcome were 97.3%, 93.6% and 78.2% two, five and over five years after HTO, respectively. The revision rate of total knee arthroplasty (TKA) was 11.8% (19 knees retreated with TKA for HTO failure). The survivorship analysis of the 19 knees retreated with TKA showed an expected survival rate of 98.7%, 95.0% and 84.1% 2, 5 and 10 years after HTO, respectively. There were 5.6% complications (12/161), including five superficial wound infections, one deep infection, five delayed bone healing, and one peroneal nerve palsy. Fifty patients (54 knees) missed follow-up, among them 10 patients (11 knees) died. CONCLUSIONS: HTO is an effective method in treating medial compartment osteoarthritis with a varus knee. Appropriate overcorrection of femorotibial alignment is the key for the success of the operation. But as the long-term effect is concerned, there is a trend of deterioration and some of the patients may have a second operation of revision with TKA.

Adult↗

High tibial osteotomy with use of the Taylor Spatial Frame external fixator for osteoarthritis of the knee.

BACKGROUND: High tibial osteotomy (HTO) is used to treat medial compartment osteoarthritis of the knee in active patients with varus alignment. In this study we review the clinical and radiographic outcomes associated with the Taylor Spatial Frame (Smith & Nephew), and its use in HTOs, and we include an illustrative case report. METHODS: In 7 patients with medial compartment osteoarthritis of the knee and varus alignment, the Taylor Spatial Frame was applied to the tibia in the operating room and a proximal tibial osteotomy was performed. Patients followed a computer-generated turning schedule until the desired correction was achieved. The frame was removed when the osteotomy site had healed. The lower extremity measure (LEM) was used to assess physical function. Clinical outcome measures relating to the Taylor Spatial Frame included latency, time to correction, time in the frame, number of residual corrections and complications. Radiographic outcomes included preoperative Resnick grades of osteoarthritis, pre- and post-correction limb alignment and tibial slope measurements. RESULTS: Average (and standard deviation) LEM grade at a mean 41 (14) months follow-up after correction was 94% (5%). Average latency was 8 days, time to correction was 15 days, time in the frame was 23 weeks and number of residual corrections was 1.3. Complications were similar to those for external fixators. Radiographic correction goals were met in all patients. CONCLUSION: The Taylor Spatial Frame is a valuable asset when using HTO to treat medial compartment osteoarthritis of the knee.

Bone Malalignment↗

[Results of the operative treatment in Madelung's deformity].

Nine wrists in eight patients were treated surgically between 1988 and 2003 for symptomatic Madelung's deformity. The pain of involved wrist followed by forearm deformation fulfilled criteria for surgery. Closing wedge osteotomy of the distal radius were carried out eight times accompanied by shortening of the ulna (four patients), excision of the distal ulna (one patient), and no ulnar surgery (three patients). Pain relieved after surgery. The follow up period ranged from 1 to 9.5 years. No pour results were stated in subjective patient's estimation during final check up. Wrist appearance were stated to be satisfactory. Limitation of the range of motion concerning supination and pronation of the forearm were stated invariably. X-ray retrospective assessment of the inclination angle, lunate coverage and presence of arthritic changes were conducted. Time and method of surgical treatment for Madelung's deformity should be considered individually.

Adolescent↗

The effect on supination-pronation of angular malalignment of fractures of both bones of the forearm.

UNLABELLED: Ten fresh human upper-extremity cadaver specimens were tested for the effect of residual angulation from simulated fractures of both bones of the forearm on the potential for range of rotation of the forearm and for limitations of pronation and supination specifically. Ten and 20-degree angulations for the radius and ulna, such as might be encountered in all reasonable clinical situations, were tested. Little significant loss of forearm rotation resulted from angulations of 10 degrees in any direction. With 20 degrees of angulation, there was statistically significant and functionally important loss of forearm rotation. CLINICAL RELEVANCE: A residual angulation of 10 degrees in mid-shaft fractures of the radius, ulna, or both bones of the forearm will not limit forearm rotation anatomically. Loss in the range of rotation can be expected with residual angeles of 20 degrees or more.

Forearm↗

Accuracy of intramedullary versus extramedullary tibial alignment cutting systems in total knee arthroplasty.

The postoperative standing 51-inch radiographs of 352 total knee arthroplasties were reviewed. The angle formed by the tibial tray to the mechanical axis of the tibia in the coronal plane was measured. The mean deviation from a perpendicular cut to the tibial mechanical axis was not significantly different between tibial cuts made with extramedullary alignment and with intramedullary alignment. With extramedullary alignment, 92% of the cuts were +/- 4 degrees of the ideal 90 degrees cut (perpendicular to the mechanical axis), whereas 94% of the cuts with intramedullary alignment were within 4 degrees of ideal. An analysis of the cuts that erred > or = 4 degrees with intramedullary alignment showed that for the majority the intra-medullary guide rod, if passed down the middle of the tibial shaft in the coronal plane, directly led to the less than ideal cut. In these tibias, bowing deformity in the coronal plane made passage of the intramedullary rod parallel to the tibial mechanical axis impossible.

Bone Malalignment↗

The efficacy of intramedullary femoral alignment in total knee replacement.

The angle formed between the femoral anatomic axis and the femoral prosthesis was measured on radiographs of 201 total knee arthroplasties. The radiographs were taken on a 51 inch x 14 inch cassette and had to have satisfactory centering and minimal rotation to be included. All total knee arthroplasties had intramedullary femoral alignment. The mean femoral component angle (relative to the femoral anatomic axis) was 6.1 degrees valgus, with a standard deviation of 2 degrees and a range from 2 degrees to 12 degrees valgus. Seventeen knees (8.5%) had a femoral component angle that was < or = 2 degrees valgus or > or = 10 degrees valgus. In 4 knees, medial femoral bowing of the distal third of the femoral shaft caused an excessive valgus cut. In 7 knees, a capacious femoral canal was present that potentially allowed for divergence of the relatively undersized guide rod in the canal. Overall, 8.5% of cuts were believed to be less than ideal. Preoperative radiographs of the entire femur should identify patients in whom errors are more likely and allow for templating the amount of distal femoral bone to be resected. Extra caution is needed in bowed femora and in capacious femoral canals.

Bone Malalignment↗

The anteroposterior axis for femoral rotational alignment in valgus total knee arthroplasty.

This study evaluated a technique using the anteroposterior axis of the distal femur, rather than the transepicondylar or posterior femoral condylar axis, to establish rotational alignment of the femoral component in valgus knees. The anteroposterior axis of the distal femur was defined by a line through the deepest part of the patellar groove anteriorly and the center of the intercondylar notch posteriorly. Total knee arthroplasty was done in 46 valgus knees between 1980 and 1986 using the posterior femoral condyles as landmarks for rotational alignment. From January 1986 through January 1992 total knee arthroplasty was done in 107 valgus knees using the anteroposterior axis for rotational alignment of the femoral component. In the group of knees using the posterior condylar axis, medial tibial tubercle transfer was needed intra-operatively in 8 knees to prevent lateral dislocation of the patella. In the first 2 postoperative years, 4 knees had recurrent patellar dislocation or subluxation that required surgical correction. In the group of knees using the anteroposterior axis, patellar tracking problems that required realignment were significantly reduced. One knee required medial tibial tubercle transfer to correct a Q angle > 20 degrees. In the remaining knees, the Q angle was < 10 degrees, and patellar tracking was acceptable. Two years after surgery, no knees had patellar instability.

Aged↗

Malrotation associated with implant alignment technique in total knee arthroplasty.

This study documents the malrotation between the femoral and tibial components associated with contemporary alignment techniques that position the tibial component relative to the tubercle, posterior tibial condyles, transtibial axis, and malleoli. The technique that allows the tibial component to float into alignment as the knee is passed through a range of motion and the technique of coupling the tibial component to the femoral component also were assessed. The average external rotation of the tibial component relative to the femoral component associated with each alignment technique is 19 degrees (tibial tubercle), 5 degrees (transtibial axis), 7 degrees (posttibial axis), 3 degrees (malleolar axis), and 14 degrees (range-of-motion technique). The coupled-component technique produced 2 degrees internal rotation. The observed tendency to externally rotate the tibial component relative to the femoral component with most alignment techniques may account for the high incidence of posteromedial polyethylene wear reported in retrieval studies.

Bone Malalignment↗

Radiographic characterization of aseptically loosened cementless total knee replacement.

From January 1980 to December 1992, 655 cementless total knee arthroplasties with the PCA total knee system were done at the authors' institution. Thirty of these knees have been revised for aseptic loosening of either tibial or femoral components or both. Patients in the failed arthroplasty group were matched directly to a control group with well-functioning, stable and painless cementless total knee prostheses (Knee Society objective score, > 90 points). In this study, the authors analyzed any alignment differences between the 2 groups of knees. Special attention was given to the postoperative radiographs to evaluate for potential predictors of success versus failure. Multiple radiographic parameters were measured for each knee and included measures of frontal alignment, sagittal alignment, rotation, percent prosthetic coverage, and cortical thickness (denoted as the cortical-cancellous index). On univariate analysis, no individual radiographic parameter was significantly different in the failure group versus the control group. However, multivariate analysis indicated that certain combinations of abnormal parameters were significantly higher in the failed group than the control group. These parameters included measures of frontal and sagittal plane component alignment. The summated abnormal parameters per patient averaged 3.67 (range, 1-7) for the failure group and 1.80 (range, 0-7) for the control group.

Activities of Daily Living↗

Flat-on-flat, nonconstrained, compression molded polyethylene total knee replacement.

Flat-on-flat, posterior cruciate ligament-sparing total knee prostheses recently have shown problems of wear, loosening, and multiple design changes. Two thousand one Anatomical Graduated Components total knee arthroplasties with compression molded, nonmodular polyethylene tibial components were done between 1983 and 1991 at 3 institutions. All knees were evaluated clinically and radiographically every 2 to 3 years; 71 knees were seen in followup > 10 years. There were 8 failures secondary to revision (5 tibial failures; 2 secondary to metalosis from patellar polyethylene dissociation; and 3 femoral failures) resulting in a 98% survival rate at 10 years. The tibial design was flat-on-flat with a compression molded polyethylene that the authors believe is the primary reason for its success.

Adult↗