PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Complement C3b”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Expression of complement receptor CR2 (CD21) on human subcorneal keratinocytes in normal and diseased skin.

Human keratinocytes are able to synthesize and express cell surface moieties characteristic of effector and/or accessory cells of the immune system (CD16, CD36, HLA-DR, intercellular adhesion molecule-1). In the present study, skin biopsies from healthy volunteers, from patients with psoriasis vulgaris (PV), mycosis fungoides (MF), purpura pigmentosa chronica (PPC), acute urticaria (AU) and from positive tuberculin skin tests were investigated with regard to the reactivity with the monoclonal antibodies to complement receptors CR1 CR2 and CR3 by means of a multistep immunoperoxidase method. In the clinically involved skin of all patients with PV, MF or PPC, and in biopsies obtained from positive tuberculin tests, specific epidermal intercellular staining with OKB7 and Leu anti-CR2 was seen on subcorneal keratinocytes. This finding suggests a differentiation-linked expression of CR2 on human keratinocytes in cytokine-mediated skin diseases whereas CR1 and CR3 are apparently not expressed.

Antigens, CD↗

Activation of the alternative pathway of complement in psoriatic lesional skin.

The complement system may play an important role in the inflammatory reaction of psoriasis. While the classical pathway of the complement has been shown to be activated in psoriasis, there have been few reports on the involvement of the alternative pathway in the inflammatory reactions in psoriasis. Complement fragments, C4d and Bb, are released at the time of the classical and alternative pathway activation, respectively. The presence of the C4d or Bb fragment, therefore, denotes a preceding complement activation through the classical and/or alternative pathway. In the present study, we have measured the levels of C4d and Bb in psoriatic scale extracts using enzyme immunoassay techniques. The scales of these dermatoses contained higher levels of C4d and Bb detectable by enzyme immunoassay than those in the stratum corneum of noninflammatory skin. These results suggest that the alternative as well as the classical pathway of complement are activated in psoriatic lesional skin.

Complement Activation↗

Cell surface proteins reacting with activated complement components.

The biologic activities mediated by the products of complement activation include cellular, bacterial, and viral lysis, inflammation, phagocytosis, and immunoregulation. These responses are achieved through the interaction of the activated forms of several of the complement proteins with cell membrane proteins. This report reviews aspects of the structure, ligand specificity, and function of the various complement receptors with particular emphasis on those receptors which bind to the activated fragments of C3. In addition, we briefly summarize the surface proteins on foreign particles that bind C3 and their possible role in the pathogenesis of these organisms.

Animals↗

Ba and Bb fragments of factor B activation: fragment production, biological activities, neoepitope expression and quantitation in clinical samples.

Factor B is a centrally important component of the alternative complement pathway. Alternative pathway activation results in factor B cleavage and production of the amino-terminal Ba and the carboxyl-terminal Bb fragments which have molecular weights of approximately 30,000 and 63,000 daltons, respectively. Both Ba and Bb fragments have been reported to express a variety of biological activities in vitro. Thus, binding of Ba and Bb fragments to specific B lymphocyte surface receptors modulates proliferation of prestimulated B cells. In addition, the enzymatically active Bb fragment induces activation and spreading of human and murine macrophages and monocytes as well as regulates C5a des Arg chemotactic activity. The fractional catabolic rate and metabolism of factor B in vivo is similar to that of C3, C4 and C5 complement proteins, which are among the most metabolically active plasma proteins in the circulatory system. Factor B hyperconsumption and increased catabolism, concomitant with factor B fragment production, occurs in a wide variety of diseases, including gram-negative sepsis, autoimmune diseases and burns. Measurement of alternative pathway activation in vivo has been attempted utilized a number of different techniques to quantitate factor B fragments in biological fluids. However, the recent development of enzyme immunoassays (EIA) employing monoclonal antibodies (MoAbs) reactive with factor B fragment neoepitopes provides the best approach currently available for the quantitation of factor B activation fragments. Results obtained using these new MoAb-based EIAs have indicated that factor B fragment concentrations were elevated, as compared with normal donor levels, in EDTA plasma samples obtained from patients with rheumatoid arthritis and systemic lupus erythematosus (SLE). Plasma concentrations of factor B fragments, especially Ba fragment levels, in these patients showed a positive correlation with disease activity scores. One of the highest disease activity correlations was obtained with Ba fragment measurements in SLE plasma samples. In fact, the results strongly suggested that quantitation of Ba fragment levels in SLE plasma samples more accurately reflected disease activity and was a more sensitive predictor of impending flare in these patients than any other test(s) currently available.

Antibodies, Monoclonal↗

Early- and late-phase activation of complement evaluated by plasma levels of C3d,g and the terminal complement complex.

Activation of the initial part (early phase) and terminal part (late phase) of the complement cascade was examined. C3d,g and the fluid-phase terminal complement complex were quantified and compared after spontaneous in vitro activation and after acute in vivo activation caused by extracorporeal circulation during coronary artery surgery. The results suggest that there is a close but not complete correlation between early- and late-phase activation of complement, that C3d,g and the terminal complement complex have different elimination rates in vivo, and that these two indicators are valuable for evaluation of early- and late-phase activation, respectively.

Complement Activation↗

Generation of C3d,g and C3d by urokinase-treated plasma in association with fibrinolysis.

In the breakdown of fluid phase C3 in plasma, the process of conversion of iC3b to C3c and 'C3d' has not been elucidated. Using fluorescent labeled iC3b as a substrate, urokinase (UK) treated but not normal plasma was found to exhibit effective 'C3d' production. To address the relationship between the fibrinolytic activity specific for UK-activated plasma and this 'C3d' production, an assay system was developed that permitted the simultaneous determination of both activities. This method indicated that 'C3d' generation paralleled that of plasmin-dependent fibrinogen degradation. A Km of iC3b for plasmin was 3.0 X 10(-6) mol/l which is similar to the Km of fibrinogen. Plasmin cleavage of iC3b gave rise to C3d1 (Mr 42,000) and C3d2 (Mr 28,000). Purified plasmin C3d1 showed the same Mr and pI as C3d,g prepared from iC3b, by H and I. C3d2 was derived from C3d1. From these in vitro experiments with urokinase-treated plasma, we conclude that in parallel with fibrinolysis efficient cleavage of fluid phase iC3b to C3c + C3d,g and C3d occurs and we hypothesize that this is one mechanism for the generation of C3d in vivo.

Complement C3↗

The association of circulating endotoxin with the development of the adult respiratory distress syndrome.

Despite extensive investigation, the pathogenesis of the adult respiratory distress syndrome (ARDS) remains uncertain. As yet, there is no clear explanation of why some patients at risk for ARDS develop the syndrome, whereas others do not. Neutrophils and complement fragments have been implicated in the acute lung injury, but it is clear from published data that evidence of complement activation alone predicts neither the development nor the severity of ARDS. We investigated whether the combination of endotoxin, a leukocyte-priming agent, and complement fragments, leukocyte-stimulating agents, was associated with the development of ARDS. Ninety-eight patients were identified as being either at risk for the development of ARDS or having ARDS, and serial blood samples were obtained. There was no correlation between C5 fragments and the development of ARDS. C3 fragment levels were increased in 89% of the patients with ARDS, but they were also increased in 62% of patients at risk. Endotoxin was detected in 74% of the plasma samples obtained from patients at risk who subsequent developed ARDS and in 64% of the plasma samples obtained from the patients with ARDS. In contrast, only 22% of the plasma samples obtained from the patients at risk who did not develop ARDS had measurable endotoxin. We suggest that the combination of endotoxin and complement fragments may be one mechanism involved in the development of ARDS.

Adult↗

Bronchoalveolar lavage fluid and serum complement activity in pulmonary sarcoidosis.

In this work, using bronchoalveolar lavage fluids (BALF), we demonstrated the presence of complement within airways by assaying hemolytic activity of the whole classical pathway (CH50) and by measuring the complement component C2 (C2H50). Patients with sarcoidosis, patients with idiopathic pulmonary fibrosis (IPF), and healthy control subjects were compared. No CH50 activity was found in BALF from healthy control subjects (n = 9), but some activity (mean, 20 CH50) was associated with IPF (n = 7). Complement activities ranged from 40 to 554 CH50 in patients with sarcoidosis (n = 27). During the treatment, complement activity decreased in BALF from the few patients in our series who received corticotherapy. C2 hemolytic activity was detected in BALF from the normal control group (in the absence of CH50 activity). In the sarcoidosis and IPF groups when CH50 was present, the variations in the C2/CH50 ratio were studied. The high ratio observed in BALF from patients with sarcoidosis and a chronic derangement of alveolar structure suggests either an increased C2 production or an alternative complement pathway (C2-independent) activation within their lungs.

Adult↗

The complement system plays a critical role in the development of experimental autoimmune anterior uveitis.

PURPOSE: The role of complement in ocular autoimmunity was explored in a experimental autoimmune anterior uveitis (EAAU) animal model. METHODS: EAAU was induced in Lewis rats by immunization with bovine melanin-associated antigen. Complement activation in the eye was monitored by Western blot for iC3b. The importance of complement to the development of EAAU was studied by comparing the course of intraocular inflammation in normal Lewis rats (complement-sufficient) with cobra venom factor-treated rats (complement-depleted). Eyes were harvested from both complement-sufficient and complement-depleted rats for mRNA and protein analysis for IFN-gamma, IL-10, and interferon-inducible protein (IP)-10. Intracellular adhesion molecule (ICAM)-1 and leukocyte-endothelial cell adhesion molecule (LECAM)-1 were detected by immunofluorescent staining. OX-42 was used to investigate the importance of iC3b and CR3 interaction in EAAU. RESULTS: There was a correlation between ocular complement activation and disease progression in EAAU. The incidence, duration, and severity of disease were dramatically reduced after active immunization in complement-depleted rats. Complement depletion also completely suppressed adoptive transfer EAAU. The presence of complement was critical for local production of cytokines (IFN-gamma and IL-10), chemokines (IP-10), and adhesion molecules (ICAM-1 and LECAM-1) during EAAU. Furthermore, intraocular complement activation, specifically iC3b production and engagement of complement receptor 3 (CR3), had a significant impact on disease activity in EAAU. CONCLUSIONS: The study provided the novel finding that complement activation plays a central role in the pathogenesis of ocular autoimmunity and may serve as a potential target for therapeutic intervention.

Adoptive Transfer↗

Human lymphocyte complement receptors. Quantitative requirements for C3 of normal and chronic lymphocyte leukemia lymphocytes.

Erythrocytes coated with varying amounts of human complement were used to detect lymphocytes with complement receptors from normal subjects and patients with chronic lymphocytic leukemia. The relationship between the percentage of lymphocytes rosetting and the quantity of C3 present on complement-coated erythrocytes were studied. Small quantities of C3 (less than 5 fg/erythrocyte) caused maximal rosetting of normal lymphocytes. Maximal rosetting with chronic lymphocytic leukemia lymphocytes was not reached until much greater amounts of C3 were used to coat the erythrocytes. This difference in sensitivity to erythrocyte-bound complement was not due to an increased fraction of complement receptor-bearing cells in the leukemic patients. This loss of sensitivity of the chronic lymphocytic leukemia lymphocyte for complement may play a role in the immune deficiency present in this disease.

Cell Membrane↗

Guinea pigs with inherited deficiencies of complement components C2 or C4 have characteristics of immune complex disease.

Guinea pigs genetically deficient in the second (C2) or fourth component of complement (C4) generally appear healthy in contrast to humans with a C2 or C4 deficiency. However, upon investigation of these genetic deficiencies in guinea pigs for signs of dysregulation in the humoral immune system and especially autoantibodies, many complement-deficient guinea pigs (greater than 50%) had elevated levels of serum IgM and higher concentrations of anti-hapten (dinitrophenyl) antibodies as signs of polyclonally stimulated antibody synthesis. In addition, a significant number of the complement-deficient animals, on average 30%, had IgM rheumatoid factors in their sera compared with less than 1% of the normal animals. These observations, therefore, indicate that guinea pigs, genetically deficient in C2 or C4, show characteristics of immune complex disease in general.

Aging↗

Veno-venous bypass in liver transplantation: heparin-coated perfusion circuits reduce the activation of humoral defense systems in an in vitro model.

We studied the effects of bypass circuit surface heparinization on kallikrein-kinin, coagulation, fibrinolytic and complement activation in a closed model system for simulating veno-venous bypass (WBP) in orthotopic liver transplantation (OLT). The circuits were identical to those in routine use during clinical OLT in our institution. Fresh whole human blood diluted 1:2 with Ringer's acetate was circulated at a non-pulsatile flow (2 l/min) and at a constant temperature (37.5 degrees C) for 12 h. In 10 experiments, the entire inner surface of the circuits was coated with end-point attached heparin (HC). In the remaining 10, non-treated PVC tubing was used (NC). Components of the plasma kallikrein-kinin, coagulation, fibrinolytic and complement systems were analyzed using functional techniques (chromogenic peptide substrate assays) and enzyme immunoassays at baseline, 3 and 12 h. Significant activation of the initial (C3bc) and terminal (TCC) components of the complement system were found in both the NC and HC groups after 3 and 12 h: C3bc: NC: baseline = 4 (3.5-7.7), 3 h = 17.3* (12.5-27), 12h = 31* (17.7-63.6), HC: baseline = 4.9 (3.2-6.8), 3h = 9* (6-14.4), 12h = 13.7* (7.4-18.1). TCC: NC: baseline = 0.4 (0.2-0.6), 3h = 5*(0.8-11.9), 12 h: 13.1* (4.2-25.7). HC: baseline = 0.5 (0.1-0.6), 3 h = 0.6* (0.1-0.8), 12 h = 1.2* (0.3-2) AU/ml; median and range (*: p < 0.05). The C3bc and TCC concentrations were significantly higher in the NC group at 3 and 12 h, compared to the HC group: C3bc (NC vs. HC group): 3 h, p < 0.001; 12 h, p < 0.001. TCC (NC vs. HC group): 3h, p < 0.001; 12 h, p < 0.001. Significant increases in the values of thrombin-antithrombin complexes (p = 0.003), prothrombin fragment 1 + 2 (p = 0.006) and plasmin-alpha2-antiplasmin complexes (p = 0.016) were found in the non-coated group, but not in the heparin-coated group during the observation period, showing that the coagulation and fibrinolytic systems were activated in the non-coated circuits. We conclude that heparin-coating of the internal surface of the extracorporeal perfusion circuit used for WBP reduces activation of the plasma cascade systems in a closed venous system in vitro.

Blood Coagulation Factors↗

Leucocyte filtration during cardiopulmonary reperfusion in coronary artery bypass surgery.

Postoperative organ dysfunction after cardiac operations has been related to the damaging effects of cardiopulmonary bypass (CPB). These complications are considered to be mediated partly by complement activation and subsequent activation of leucocytes due to the contact between blood and the large nonendothelial surfaces in the bypass circuit. Removal of leucocytes by filtration during the reperfusion period may potentially reduce the postoperative morbidity after CPB. Forty patients undergoing elective, primary coronary artery bypass grafting were randomized to initial identical bypass circuits until the aortic crossclamp was released. Then, the ordinary arterial line filter was closed and either a leucocyte depletion filter (n = 20), or a control filter (n = 20) was incorporated in the circuits during the reperfusion period of CPB. Blood samples were drawn at fixed intervals and analysed for white blood cell and platelet counts, plasma concentration of myeloperoxidase, C3-complement activation products, the terminal complement complex, and interleukins (IL)-6 and -8. The numbers of circulating white blood cells in the leucocyte-depleted group decreased during the reperfusion period from 5.5 (4.8-6.8) to 5.3 (4.4-6.2) x 10(9)/l, and increased in the control group from 6.5 (5.1-8.0) to 7.4 (5.7-9.0) x 10(9)/l. Two hours postoperatively the total white blood cell count in the leucocyte-depleted group was 14.7 (12.1-17.2) x 10(9)/l, and in the control group 17.6 (14.5-20.7) x 10(9)/l. The differences between the groups were statistical significant (p = 0.05). There were no statistically significant differences between the groups with regard to other test parameters or clinical data. We conclude that the use of leucocyte filters during the reperfusion period in elective coronary artery bypass surgery significantly reduced the number of circulating leucocytes, whereas no effects were seen for granulocyte activation measured as myeloperoxidase release, platelet counts, complement activation, or IL-6 and -8 release. The clinical benefit of leucocyte filters in routine or high risk patients remains to be demonstrated and is suggested to be dependent on both the efficacy and the biocompatibility of the filters.

Aged↗

Comparison of three oxygenator-coated and one total-circuit-coated extracorporeal devices.

The present study was designed to compare the biocompatibility of three cardiopulmonary bypass setups with different surface coatings, and to determine if coating of the whole circuit with one of the coatings was more beneficial than coating of the oxygenator only. Extracorporeal devices entirely coated with synthetic polymers (Avecor, n = 6) were compared to oxygenators coated with synthetic polymers (Avecor, n = 6), end-point, covalently attached heparin (CBAS, n = 6) or absorbed heparin (Duraflo 2, n = 6) in an in vitro model of a heart lung machine. The circuits were primed with fresh human whole blood and Ringer's acetate and recirculated at 4 l/min at 30 degrees C for 2 h. Test samples were obtained at regular intervals and analysed for myeloperoxidase (MPO), platelet counts, beta-thromboglobulin, heparin, prothrombin fragment 1+2, plasmin anti-plasmin complexes, and complement activation products. The mean MPO concentrations increased in the Avecor-coated oxygenator group (AV) from 247 at the start to 671 microg/l at the termination of the experiments, in the Avecor-coated total circuit group (AV-T) from 116 to 288 microg/l, in the Duraflo 2 coated oxygenator group (DU) from 160 to 332 microg/l, and in the CBAS-coated oxygenator (CA) group from 172 to 311 microg/l. The MPO concentrations increased significantly in all groups (p < 0.03). The increase in group A was significantly higher than in the other three groups (p = 0.007). The mean platelet counts decreased in the Avecor-coated total circuit group from 117 at start to 99 x 10(9)/l at termination of the experiments, in the Avecor-coated oxygenator group from 119 to 103 x 10(9)/l, in the Duraflo 2 group from 96 to 86 x 10(9)/l, and in the CBAS group from 132 to 123 x 10(9)/l. The platelet counts decreased significantly in all groups (p < 0.01), but the intergroup differences were not significant (p = 0.15). The mean beta-thromboglobulin concentrations increased in the Avecor-coated total circuit group from 193 at the start to 754 ng/ml at the termination of the experiments, in the Avecor-coated oxygenator group from 474 to 1654 ng/l, in the Duraflo 2 group from 496 to 1280 ng/l, and in the CBAS group from 418 to 747 ng/l. The beta-thromboglobulin increase was significant in each group (p < 0.01), but not between the groups (p = 0.49). The mean heparin concentrations in the Duraflo 2 group increased from 2460 at the start to 2897 IU/l at termination of the experiments, in the CBAS group from 2468 to 2518 IU/l. In the Avecor-coated oxygenator group heparin concentrations decreased from 2010 to 1968 IU/l, and in the Avecor-coated total circuit group from 2002 to 1927 IU/l. The differences in heparin concentrations were significant between the Duraflo 2 group and the other groups (p < 0.05). The mean prothrombin fragment 1+2 concentrations increased in the CBAS group from 0.4 at the start to 2.1 nmol/l at the end of the experiments, in the Avecor-coated oxygenator group from 0.4 to 0.6 nmol/l, in the Avecor-coated total circuit group from 0.3 to 0.4 nmol/l, and in the Duraflo 2 group from 1.2 to 1.3 nmol/l. The prothrombin fragment 1+2 increase was significant in all groups (p < 0.05), but there were no significant intergroup differences (p = 0.54). There were no significant differences at the termination of the experiments among the four groups regarding complement activation as measured by C3 activation products and the terminal complement complex. In the present in vitro model of a heart-lung machine, none of the three specific setups with different coatings was superior with regard to all test parameters. The CBAS group generated the highest levels of prothrombin fragment 1+2 formation, but least complement activation. The increasing plasma heparin concentrations in the Duraflo 2 group indicated more unstable heparin bonding. The Avecor-coated total circuit group were superior to the Avecor-coated oxygenator group regarding plasma concentrations of MPO, but not compa

Antifibrinolytic Agents↗

Evaluation of a new condensed extra-corporeal circuit for cardiac surgery: a prospective randomized clinical pilot study.

This prospective randomized clinical pilot study was conducted to evaluate a recently introduced reduced volume CPB system that is coated with the biopassive Xcoating. Twenty-two patients undergoing coronary artery bypass grafting (CABG) with cardiopulmonary bypass (CPB), either with a fully heparin-coated CPB circuit (control, n=11) or with an Xcoating coated condensed extra-corporeal circuit (CondECC, n=11), were included. We examined activation of the complement system (C3bc and C4bc), activation of neutrophils (BPI), the acute phase response (interleukin (IL)-6, and acute phase proteins (LBP, AGP, and CRP)), myocardial tissue injury (troponin T), hemolysis (free hemoglobin (FHb)), and clinical outcome parameters. Preoperative risk profiles were identical for both patient groups. All patients went through the procedure without major complications and were discharged from the hospital. FHb and BPI levels at the end of pump support (p < 0.01) and at 15 min after the administration of protamine (p < 0.05) were significantly higher in the control group. In addition, FHb levels were still significantly elevated upon arrival on the cardiothoracic intensive care unit (CICU) in the control group (p < 0.05). C3bc and C4bc, acute phase proteins, IL-6, and troponin T concentrations, and clinical outcome variables were identical in both patient groups. In conclusion, the evaluated condensed extracorporeal circuit is a flexible and multifunctional CPB sytem that offers safe procedures. Furthermore, the results indicate improved biocompatibility of this option for extracorporeal circulation.

Acute-Phase Proteins↗

Pleural SC5b-9 in differential diagnosis of tuberculous, malignant, and other effusions.

A monoclonal antibody against soluble phase-terminal complement complex (SC5b-9) was used to try to differentiate pleural effusions of tuberculous vs malignant and other origin. Effusions of tuberculous origin showed a significantly higher SC5b-9 level than did plasma, suggesting activation of complement in the pleural space. All 26 patients with tuberculous effusions showed SC5b-9 levels in pleural fluid exceeding 2.0 mg/L, while 20 with malignant effusions had levels less than 2.0 mg/L. However, rheumatoid, some parapneumonic, and treated malignant effusions showed SC5b-9 levels above 2.0 mg/L. Considering a value exceeding 2.0 mg/L, the specificity and sensitivity of the SC5b-9 estimation in tuberculosis were 0.74 and 1.0, respectively. The mean values for C4d and Bb fragments of complement were significantly (p < 0.05) higher in the tuberculous than in the malignant effusions. However, the values for Bb in 16 (62 percent) of the 26 patients with tuberculous or malignant effusions were in the same range. The activity of adenosine deaminase (ADA) was higher in the tuberculous than in the malignant effusions. While 18 of 26 patients with tuberculous effusions showed an ADA value exceeding 50 mU/ml, the estimated cutoff point (sensitivity = 0.69), 35 of the 36 nontuberculous effusions showed a true negative value (specificity = 0.97). A correlation between ADA and SC5b-9 values was observed in pleural effusions. These observations suggest that the estimation of SC5b-9 in pleural fluid presents a new approach to differentiating tuberculous vs malignant effusions.

Adenosine Deaminase↗

Attachment of the soluble complement regulator factor H to cell and tissue surfaces: relevance for pathology.

Complement is a central element of innate immunity and this vital defense system initiates and coordinates immediate immune reactions which attack and eliminate microbes, foreign particles and altered self cells. Newly generated activation products are extremely toxic and consequently, activation is highly restricted in terms of time and space. The initial activation of the alternative complement pathway occurs continuously and the early phase acts indiscriminatoryl and forms on any surface. However, the system discriminates between self and foreign, and therefore allows activation on foreign surfaces e.g. microbes, and restricts activation on host cells. Consequently, self cells and tissues are protected from the harmful activation products. This protection is mediated by specific regulators or inhibitors, which exist in the fluid phase and/or in membrane-bound forms. Here we review a novel mechanism, i.e. the attachment of the soluble complement regulator factor H to the surface of self cells. This attachment, which is demonstrated experimentally by means of immunofluorescense microscopy and by flow cytometry, increases the inhibitory potential at the cell surface and mediates protection by reducing the local formation of toxic inflammatory products. This attachment is highly relevant and has pathophysiological consequences in several human diseases, including Factor H-associated hemolytic uremic syndrome (FH-HUS), membrano-proliferative glomerulonephritis type II, recurrent microbial infections and chronic inflammation, e.g. rheumatoid arthritis and immune evasion of tumor cells. Defects of this safeguard activity have been recently understood in patients with FH-HUS. Point mutations in the Factor H gene occurring in the C-terminus of the protein result in impaired cell binding capacity of Factor H and, consequently, during an inflammatory insult endothelial cells are not properly protected and are damaged.

Animals↗

Protection of baculovirus-vectors against complement-mediated inactivation by recombinant soluble complement receptor type 1.

Baculovirus-based vectors are efficient means for gene transfer into hepatocytes in vitro. However, gene transfer in vivo is hampered by inactivation of baculovirus by the complement system. In this study, we demonstrate protection of baculovirus vectors against complement-mediated inactivation through recombinant soluble complement receptor type 1 (sCR1). Blocking of only the alternative complement pathway by a mutant of sCR1 did not result in baculovirus survival in human serum. The data suggest the use of sCR1 as a potent drug to facilitate baculovirus-mediated gene transfer into hepatocytes in vivo.

Animals↗