Prospective 3-year study of cross-arch fixed partial dentures in patients with advanced periodontal disease.

STATEMENT OF PROBLEM: Several choices exist for the treatment of advanced periodontal disease. One is a combined periodontal and prosthetic treatment that includes cross-arch fixed partial dentures (FPDs). However, the outcomes of such therapy have been reported mainly from studies in Scandinavian countries. PURPOSE: The aims of this study were: (1) to longitudinally evaluate, after periodontal and prosthodontic treatment that included cross-arch FPDs, treatment outcomes in Korean patients who suffered from severe periodontitis; and (2) to evaluate the patients' treatment assessments and the FPDs after 3 years. MATERIAL AND METHODS: This survey included 39 Korean patients provided with 50 FPDs. Clinical and radiographic examinations were performed at the time of delivery of the FPDs and at the 3-year follow-up examinations. The prostheses were divided into 3 groups according to design (end abutments, unilateral cantilever, and bilateral cantilevers) and the amount of supporting tissues at the time of insertion. On average, only 26% of the total original periodontal tissue remained at the time of insertion. The FPDs consisted of 11 to 14 units, with a mean of 5 to 7 abutments in the 3 groups. The mean periodontal ligament area of the abutments was 79% of the total ligament area of the replaced teeth. RESULTS: At the 3-year follow-up examination, the FPDs were stable in all patients, who in general displayed good oral hygiene and had healthy periodontal conditions. The change in periodontal ligament area over the 3-year observation period was negligible (1 mm(2) per dental unit) and showed no statistically significant difference in relation to FPD design. Most patients were satisfied with the function of their FPDs with respect to mastication, phonetics, hygiene, esthetics, and chewing comfort. A few patients stated that they were careful with the FPDs and avoided certain foods (for example, raw peanuts and grilled squid) because they felt insecure with the cantilever segments. Most patients reported that they would choose the same treatment again. CONCLUSION: Patients with advanced periodontal disease demonstrated successful outcomes over a 3-year period and reported satisfaction with combined periodontal and restorative treatment that included cross-arch FPDs.

Adult↗

In vitro study on passive fit in implant-supported 5-unit fixed partial dentures.

PURPOSE: Fabrication and retention methods have an influence on the passivity of superstructure fit. The objective of the study was to quantify the strain development of various cemented and screw-retained fixed partial dentures (FPDs). MATERIALS AND METHODS: Forty samples of 4 different types of FPDs (10 of each type) were investigated. Each sample had 3 ITI implant abutments and 2 pontics. The 3 implants were anchored in a straight-line configuration in a measurement model simulating a real-life patient situation. Strain gauges were mounted close to the implants and on the pontics. The developing strains were recorded during cement setting and screw fixation. For statistical analysis, multivariate 2-sample tests were performed, with the level of significance set at P = .1. RESULTS: All FPDs investigated revealed a considerable amount of strain, with no significant difference between cement and screw retention. Furthermore, no significant difference was found between the conventional fabrication modes for screw-retained FPDs. The lowest strains were found in prostheses that were intraorally bonded onto gold cylinders. DISCUSSION: Because bonding of the superstructure in the oral cavity may compensate for impression and laboratory variables, restorations with the best possible passive fit can result from this retention technique. Before this technique can be recommended, the long-term stability of the adhesive layer should be investigated. CONCLUSIONS: As an absolute passive fit of superstructures is not possible using conventional clinical and laboratory procedures, and as clinical fit-evaluation methods often do not detect "hidden" inaccuracies, the more sensitive strain-gauge technique should be utilized for an objective accuracy test. Reference strain values from implant-supported prostheses that have served without complications could help define a "biologically acceptable fit.

Aged↗

Overdenture abutments for fixed partial dentures.

Despite universal acceptance for retaining endodontically treated and filled roots for vertical support of removable prostheses, there is little evidence for the use of overdenture abutments with fixed prostheses. This article presents a review of clinical situations for using these teeth to support fixed partial dentures. These teeth provide vertical support during function and preserve alveolar bone levels.

Dental Abutments↗

Pontic design and localized ridge augmentation in fixed partial denture design.

The endpoint of fixed prosthesis design is an esthetic and functional pontic that is compatible with soft-tissue health. In the posterior segment, where esthetics is not as critical, a sanitary pontic form is most compatible with function and hygiene. In the maxillary anterior region, a properly contoured modified ridge-lap pontic design constructed of glazed porcelain most readily fulfills both the esthetic and physiologic requirements. Although the ovate pontic form may satisfy esthetic demands to a greater degree, this is often at the expense of underlying soft-tissue health. In maxillary edentulous regions, ridge deformities may preclude a good pontic fit and esthetic result and dictate the need for surgical augmentation of the collapsed ridge. Selection of the appropriate surgical procedure and graft material depends on the nature and extent of the defect and availability of donor tissue. The subepithelial graft employing the tunnel approach is appropriate when augmentation in only a labial dimension is necessary. When the employing the trapdoor approach or full thickness gingival onlay graft may be employed. In large defects, sequential grafting procedures may be necessary to achieve the desired result. An esthetic and functional result can be attained through proper execution of an appropriate surgical technique and adherence to the principles of proper pontic design.

Alveolar Ridge Augmentation↗

Adhesive-fixed partial dentures in anterior and posterior areas. Results of an on-going prospective study begun in 1985.

Within the framework of an on-going prospective clinical study begun in 1985, 120 adhesive-fixed partial dentures (AFPD) continued to be examined. The manufacture and the fitting of the AFPDs were carried out following a standard procedure. The preparation technique and the metal framework conditioning (silica-coating, sand-blasting and electrochemical etching) has varied throughout the duration of the study. Using Kaplan-Meier analysis, the survival rate was determined and an analysis of risk with regard to location factors (anterior, posterior; maxilla, mandible), conditioning and preparation techniques (retentive/non-retentive) was determined using the Cox regression model. The location of the AFPD had no influence on the survival rate. The survival time was determined mainly by the preparation technique. Strict preparation of seating grooves and pin holes made a 95% survival rate possible after 10 years (Kaplan-Meier estimation). Without retention, the risk of failure increased by a factor of 3.7.

Adolescent↗

Composite veneering of metal based fixed partial dentures.

The aim of this in vitro study was to determine the thermal mechanical properties of veneering composites after polymerization with the appropriate polymerization device. Fracture tests were performed to investigate the effect on fixed partial dentures (FPDs). Dynamic mechanical thermal analysis was used to determine the temperature-dependent mechanical properties. To approximate the clinical situation, the fracture resistance of three-unit metal-based FPDs with different composite veneering was investigated after a simulated 5-year oral wearing period. The restorations were made of a high gold alloy and veneered with three different composites. To determine the influence of fabrication, one composite was used in a light-polymerizing and a heat/pressure-curing version and, in addition, a newly developed heat protection paste was used. After a 5-year simulation period, the fracture resistance was determined. The storage modulus varied between 14268 N mm(-2) (Belleglass) and 6616 N mm(-2) (Sinfony). Adoro showed no significant differences between light curing (9155 N mm(-2)) and heat curing (8184 N mm(-2)) variations. The Adoro-veneering with the heat protection paste showed the highest median fracture strength (1700 N), followed by Adoro LC (1555 N), Belleglass (1051 N), Adoro HP (1150 N) and Sinfony (909 N). The most common failure type occurring in all FPDs was a cracking of the composite, exposing the metal framework. All FPDs showed stress cracking of the composite. The heat protection paste seemed to reduce the crack formation after fabrication and increased the fracture resistance of the composite veneering. Stress cracking after thermal cycling and mechanical loading affected all composites, but all veneered three-unit alloy FPDs showed a fracture resistance sufficient for posterior application.

Composite Resins↗

Fracture resistance of fiber-reinforced PMMA interim fixed partial dentures.

PURPOSE: To compare different fiber reinforcements on fracture toughness of interim polymethyl methacrylate materials and then use the best combination to determine the optimal position for fiber placement in an interim 3-unit fixed partial denture (FPD). MATERIALS AND METHODS: In the first stage of the study, five groups of notched fracture toughness specimens were fabricated and loaded to failure (Instron): (1) unreinforced (control); (2) reinforced with pre-impregnated silanized E-glass fibers (Fibrestick); (3) cold plasma-treated woven polyethylene fibers (Ribbond triaxial); (4) pre-impregnated silanized plasma-treated woven polyethylene fibers (Construct); and (5) 1.0-mm-diameter stainless steel wire. In the second stage, the optimal position (occlusal, middle, or cervical third of pontic) for reinforcement with glass fibers (regimen 2) was tested by loading a 3-unit FPD to failure. All groups were compared with analysis of variance (alpha < 0.05). RESULTS: The fracture toughness (in MPam(1/2)) for each reinforced group (Fibrestick 2.74 +/- 0.12, Construct fibers 2.59 +/- 0.28, Ribbond triaxial 2.13 +/- 0.20, and orthodontic wire 1.66 +/- 0.09) was statistically greater (p< 0.05) than for the unreinforced group (control = 1.25 +/- 0.006). Fracture loads for FPDs were greatest when the fiber reinforcements were placed in the cervical third (cervical = 1165 N). CONCLUSIONS: The use of fiber and, to a lesser extent, orthodontic wire is an effective method to reinforce interim restoration resins.

Analysis of Variance↗

Survival rates of IPS empress 2 all-ceramic crowns and fixed partial dentures: results of a 5-year prospective clinical study.

OBJECTIVE: The aim of this prospective clinical study was to evaluate the survival rates of IPS Empress 2 (Ivoclar Vivadent) all-ceramic crowns and fixed partial dentures (FPDs) after an observation period of up to 5 years. METHOD AND MATERIALS: Forty-three patients (19 women and 24 men) were included in this study. The patients were treated with a total of 58 adhesive bonded IPS Empress 2 restorations. A total of 27 single crowns were placed on molars and premolars, and 31 three-unit FPDs were placed in the anterior and premolar regions. Clinical follow-up examinations took place at 6, 12, 24, 36, 48, and 60 months after insertion. Statistical analysis of the data was calculated using the Kaplan-Meier method. RESULTS: Results of the 50-month analysis (interquartile range, 33 to 61 months) showed that the survival rate was 100% for crowns and 70% for FPDs. Six failures that occurred exclusively in the three-unit FPDs were observed. Framework fractures were recorded in three FPD units where the connector dimensions did not meet the manufacturer specifications. Only one FPD exhibited an irreparable partial veneer fracture, and 2 FPDs showed evidence of biologic failures. The accuracy of fit and esthetic parameters were clinically satisfactory for crowns and FPDs. CONCLUSION: The results of this 5-year clinical evaluation suggest that IPS Empress 2 ceramic is an appropriate material for the fabrication of single crowns. Because of the reduced survival rates, strict conditions should be considered before the use of IPS Empress 2 material for the fabrication of three-unit FPDs.

Adult↗

Fracture strength of artificially aged 3-unit adhesive fixed partial dentures made of fiber-reinforced composites and ceramics: an in vitro study.

OBJECTIVE: The aim of this in vitro study was to examine the fracture strength of metal-free 3-unit adhesive fixed partial dentures (AFPDs) bonded to mandibular incisors. METHOD AND MATERIALS: Extracted human incisors were positioned in pairs in polymethyl methacrylate resin simulating a clinical anterior situation. Their lingual sides were prepared for adhesive retainers with surfaces and finishing lines in enamel. Eight 3-unit AFPDs were made on master casts per material system: Connect/belleGlass (Girrbach), StickNet (StickTech)/Sinfony (3M Espe), and Empress 2 (Ivoclar Vivadent). The dentures were bonded adhesively using the dual-curing system ED Primer/ Panavia F (Kuraray Europe) and aged by thermocycling (6,000 x 5 degrees C/55 degrees C H2O; 2 minutes each cycle) and mechanical loading (1.2 x 10(6) x 20 N with 1.66 Hz) in an artificial oral environment representing a wearing period of 5 years. The fracture strength was determined in a universal testing machine (UTM 1446, Zwick) at a speed of 1 mm/min, applying the load buccoincisally on the pontics. The different forms of failure were described optically. Medians (25th/75th percentiles) of the fracture results were calculated. Statistical analysis was performed using Mann-Whitney U and Kruskal-Wallis tests (P < or = .05). RESULTS: Five StickNet/Sinfony AFPDs and 7 Empress 2 restorations failed in the artificial oral environment. The remaining Empress 2 dentures showed the highest medians of fracture forces (339 [200/506] N) compared to Connect/belleGlass (257 [242/310] N) and StickNet/Sinfony (256 [204/347] N). Statistical comparisons showed no significant differences. CONCLUSION: Only Connect/belleGlass and Empress 2 showed sufficient resistance against mastication

Composite Resins↗

Comparison of failure rates of adhesive-fixed partial dentures for in vivo and in vitro studies.

The objective was to investigate associations between the results of an in vitro and an in vivo study using an artificial mouth and a study of adhesive fixed partial dentures (AFPD) begun in 1985 [1]. Twenty extracted human molars and 20 human upper incisors were inserted into PMMA resin, 6 mm apart to represent a gap. Two preparation methods (identical to those in in vivo conditions) were used: a retentive preparation technique (posterior) and a non-retentive preparation technique (anterior). The frameworks of the bridges consisted of CoCr-alloy with a ceramic veneered pontic to replace the missing tooth. The bonding surfaces of the posterior AFPDs were conditioned with a tribochemical system, while the anterior AFPDs were sandblasted. All AFPDs were inserted using a dual curing composite cement. During thermal-cycling and mechanical loading (TCML: 6000 x 5 degrees C, 1.2 x 10(6) x 50 N, 1.66 Hz) in an artificial environment, the frequency and type of failures were observed. The above mentioned loading parameters were hypothesized to represent a period of 5 years under oral conditions. The results were compared to those of similar bridge-types in the in vivo study. The Kaplan-Meier estimations showed similar graphs for in vivo and in vitro with both types of AFPDs. In vivo and in vitro, the retentively prepared AFPDs were markedly more successful. With regard to the failure types, the simulation-parameters seemed to represent a loading stress that was comparable to in vivo conditions.

Acid Etching, Dental↗

Marginal adaptation of three-unit fixed partial dentures constructed from pressed ceramic systems.

PURPOSE: This study compares the marginal accuracy of posterior metal ceramic (MC), all-ceramic IPS Empress 2 and experimental pressed ceramic (EPC-VP 1989/4) three-unit fixed partial dentures (FPD), before and after luting and after thermo-mechanical fatigue in a dual-axis chewing simulator. MATERIALS AND METHODS: Caries-free human teeth (n=160) were used as abutments for the fabrication of eighty posterior three-unit FPD, divided into two test-groups, IPS Empress 2 and EPC, of 32 samples each and one control group of 16 samples metal ceramic FPD. All FPD were cemented with Variolink II dual-curing resin cement. Half of the samples in each group were exposed to a dual-axis chewing simulator. RESULTS: The geometric mean marginal gap values (microm, before cementation, after cementation and after thermo-mechanical fatigue) amounted to 53, 63 and 62 for the ceramic metal FPD, 57, 71 and 68 for the Empress 2 FPD and 55, 67 and 68 for the EPC FPD. In all groups a statistically significant increase in marginal gap width was observed after cementation. The effect of functional loading in the chewing simulator on marginal gap was not significant. Marginal gap was lowest in the control group but differences with all-ceramic materials were small in all evaluation stages. CONCLUSION: Within the limits of this investigation, it can be concluded that marginal gap values of these all-ceramic materials and conventional MC techniques are on a similar level. In particular, almost all marginal gap values observed in this study were within the limits of clinical acceptance.

Bicuspid↗

Passivity of fit and marginal opening in screw- or cement-retained implant fixed partial denture designs.

The relationship of stress generation upon placement of cement-retained or screw-retained implant restorations has not been thoroughly investigated. Passivity of fit and marginal discrepancies of screw- and cement-retained implant fixed partial denture (FPD) designs were determined using a photoelastic model of a partially edentulous posterior mandibular arch with 3 screw-type implants. Buccal and lingual marginal openings, measured with a traveling microscope before cementation or screw tightening, revealed no statistical difference in adaptation between designs. Screw tightening caused a reduction in marginal opening (changes significant, P < .05). The opening with the cemented FPDs was similar before and after cementation. Photoelastic evaluation of the FPDs showed that cement-retained FPDs exhibited a more equitable stress distribution than did their screw-retained counterparts.

Cementation↗

The mandibular posterior fixed partial denture.

Absence of a mandibular posterior tooth, particularly the first molar, is the basic common denominator in a wide range of dental disorders. Despite their awareness of this fact, many dentists are deterred from the routine construction of mandibular posterior fixed partial dentures because of several technical difficulties. An attempt has been made to show how these difficulties may be overcome to give a predictable and satisfactory result.

Bicuspid↗

A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5 years. II. Combined tooth--implant-supported FPDs.

OBJECTIVES: The objective of this systematic review was to assess the 5- and 10-year survival of combined tooth-implant-supported fixed partial dentures (FPDs) and the incidence of biological and technical complications. METHODS: An electronic MEDLINE search supplemented by manual searching was conducted to identify prospective and retrospective cohort studies on FPDs with a mean follow-up time of at least 5 years. Patients had to have been examined clinically at the follow-up visit. Assessment of the identified studies and data abstraction was performed independently by two reviewers. Failure and complication rates were analyzed using random-effects Poisson regression models to obtain summary estimates of 5- and 10-year survival proportions. RESULTS: From a total of 3844 titles and 560 abstracts, 176 articles were selected for full-text analysis, and 13 studies met the inclusion criteria. Meta-analysis of these studies indicated an estimated survival of implants in combined tooth-implant-supported FPDs of 90.1% (95 percent confidence interval (95% CI): 82.4-94.5%) after 5 and 82.1% (95% CI: 55.8-93.6%) after 10 years. The survival rate of FPDs was 94.1% (95% CI: 90.2-96.5%) after 5 and 77.8% (95% CI: 66.4-85.7%) after 10 years of function. There was no significant difference in survival of tooth and implant abutments in combined tooth-implant FPDs. After an observation period of 5 years, 3.2% (95% CI: 1.5-7.2%) of the abutment teeth and 3.4% (95% CI: 2.2-5.3%) of the functionally loaded implants were lost. After 10 years, the corresponding proportions were 10.6% (95% CI: 3.5-23.1%) for the abutment teeth and 15.6% (95% CI: 6.5-29.5%) for the implants. After a 5 year observation period, intrusion was detected in 5.2% (95% CI: 2-13.3%) of the abutment teeth. Intrusion of abutment teeth were almost exclusively detected among non-rigid connections. CONCLUSION: Survival rates of both implants and reconstructions in combined tooth-implant-supported FPDs were lower than those reported for solely implant-supported FPDs (Pjetursson et al. 2004). Hence, planning of prosthetic rehabilitation may preferentially include solely implant-supported FPDs. However, anatomical aspects, patient centered issues and risk assessments of the residual dentition may still justify combined tooth-implant-supported reconstructions. It was evident from the present search that tooth-implant-supported FPDs have not been studied to any great extent and hence, there is a definitive need for more longitudinal studies examining these reconstructions.

Algorithms↗

Viscoelastic finite element analysis of an all-ceramic fixed partial denture.

In recent years metal-free ceramic systems have become increasingly popular in dental practice because of their superior aesthetics, chemical durability and biocompatibility. Recently, manufacturers have proposed new dental ceramic systems that are advertised as being suitable for posterior fixed partial dentures (FPDs). Reports indicate that some of these systems have exhibited poor clinical performance. The objective of this study was to use the viscoelastic option of the ANSYS finite element program to calculate residual stresses in an all-ceramic FPD for four ceramic-ceramic combinations. A three-dimensional finite element model of the FPD was constructed from digitized scanning data and calculations were performed for four systems: (1) IPS Empress 2, a glass-veneering material, and Empress 2 core ceramic; (2) IPS Eris a low fusing fluorapatite-containing glass-veneering ceramic, and Empress 2 core ceramic; (3) IPS Empress 2 veneer and an experimental lithium-disilicate-based core ceramic; and (4) IPS Eris and an experimental lithium-disilicate-based core ceramic. The maximum residual tensile stresses in the veneer layer for these combinations are as follows: (1) 77 MPa, (2) 108 MPa, (3) 79 MPa, and (4) 100 MPa. These stresses are relatively high compared to the flexural strengths of these materials. In all cases, the maximum residual tensile stresses in the core frameworks were well below the flexural strengths of these materials. We conclude that the high residual tensile stresses in all-ceramic FPDs with a layering ceramic may place these systems in jeopardy of failure under occlusal loading in the oral cavity.

Ceramics↗

Bone level change at implant-supported fixed partial dentures with and without cantilever extension after 5 years in function.

OBJECTIVE: The aim of this study was to retrospectively analyze whether the inclusion of cantilever extensions increased the amount of marginal bone loss at free-standing, implant-supported, fixed partial dentures (FPDs) over a 5-year period of functional loading. MATERIAL AND METHODS: The patient material comprised 45 periodontally treated, partially dentate patients with a total of 50 free-standing FPDs supported by implants of the Astra Tech System. Following FPD placement (baseline) the patients were enrolled in an individually designed supportive care program. A set of criteria was collected at baseline to characterize the FPDs. The primary outcome variable was change in peri-implant bone level from the time of FPD placement to the 5-year follow-up examination. The comparison between FPDs with and without cantilevers was performed at three levels: FPD level, implant level, and surface level. Bivariate analysis was performed by the use of the Mann-Whitney U-test and stepwise regression analysis was utilized to evaluate the potential influence of confounding factors on the change in peri-implant bone level. RESULTS: The overall mean marginal bone loss for the implant-supported FPDs after 5 years in function was 0.4 mm (SD, 0.76). The bone level change at FPDs placed in the maxilla was significantly greater than that for FPDs in the mandible (0.6 versus 0.2 mm; p<0.05). No statistically significant differences were found with regard to peri-implant bone level change over the 5 years between FPDs with and without cantilevers at any of the levels of comparisons. The multivariate analysis revealed that the variables jaw of treatment and smoking had a significant influence on peri-implant bone level change on the FPD level, but not on the implant or surface levels. The model explained only 10% of the observed variance in the bone level change. CONCLUSION: The study failed to demonstrate that the presence of cantilever extensions in an FPD had an effect on peri-implant bone loss.

Alveolar Bone Loss↗

Long-term follow-up of cross-arch fixed partial dentures in patients with advanced periodontal destruction. Evaluation of the supporting tissues.

The aim of the study was to evaluate the periodontal conditions in patients treated more than 10 years ago for advanced periodontal disease and rehabilitated with cross-arch fixed partial dentures (FPDs). Of 50 randomly selected patients, 34 subjects carrying 43 FPDs agreed to participate in a clinical and radiographic follow-up examination. The FPDs were divided into three groups on the basis of prosthesis design (end abutments, unilateral cantilever, and bilateral cantilevers) and amount of supporting tissues at the time of bridge installation. Seventy per cent of the FPDs were found to be unchanged, whereas the rest had been modified due to various complications leading to extraction of one or more of the abutment teeth. Six FPDs (14%) had been partially replaced by FPDs anchored to osseointegrated dental implants. A total of 21 (8%) of the original 274 abutment teeth had been extracted. Longitudinal changes in the amount of periodontal support were minimal over the average of 15 years of follow-up. FPD design or initial amount of supporting tissues was found not to have significant influence on longitudinal changes in periodontal conditions. It was concluded that combined periodontal and prosthodontic treatment of patients with advanced loss of periodontal support may provide a high rate of long-term successful outcome, provided proper adequate periodontal and prosthetic treatment and maintenance care are given.

Aged↗

Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system.

Clinical long-term success of all-ceramic dental restorations can be significantly influenced by marginal discrepancies. As a result, this in vitro study evaluated the marginal fit of alumina- and zirconia-based fixed partial dentures (FPDs) machined by the Precident DCS system. Different master steel models of three-, four- and five-unit posterior FPDs with an 0.8 mm chamfer preparation were produced. FPDs made of DC-Zirkon and In-Ceram Zirconia core ceramics were machined by the Precident DCS system. The marginal fit of the milled frameworks placed on the master steel models was determined by a replica technique using a light-body silicone to fill the discrepancies between crown and tooth and a heavy-body material to stabilize the light-body impression material. The impressions were poured into an epoxy resin material and each model was cross-sectioned with a low speed diamond saw to better visualize marginal discrepancies. The marginal fit of the FPDs was evaluated by scanning electron microscopy. The measurements of the marginal fit exhibited mean marginal discrepancies in a range between 60.5 and 74.0 microm, mean marginal gaps in a range from 42.9 to 46.3 microm, mean vertical discrepancies in a range from 20.9 to 48.0 microm and mean horizontal discrepancies in the range of 42.0 to 58.8 microm. Statistical data analysis was performed using the non-parametric test of Kruskal-Wallis and Mann-Whitney. The analysis revealed no significant differences (p>0.05) between the mean marginal gaps and vertical and horizontal discrepancies. However, for some FPDs the mean values of the marginal discrepancies were significantly different (p < or =0.05). The wide range of the measured values may be attributed to the complex geometrical design of long span FPDs and difficulties regarding the milling process of brittle ceramic materials. Based on the selection of 100 microm as the limit of clinical acceptability, the results of this study can conclude that the level of marginal fit for alumina- and zirconia-based FPDs achieved with the Precident DCS system meet the clinical requirements.

Aluminum Oxide↗