The potential for Laplacian maps to solve the inverse problem of electrocardiography.

This paper presents a method to solve the inverse problem of electrocardiography using the Laplacian of the body surface potentials. The method presented is studied first using trade-off curves from a concentric spheres model representing a heart-torso system. Then a more conventional study is undertaken where a limited number of current dipoles are placed within the inner sphere and noise is added to the resulting potentials and Laplacians on the surface of the outer sphere. The result indicate that measurements of the outer surface Laplacian can more accurately reconstruct epicardial potentials than measurements of the outer surface potentials. The reconstructions are more accurate in that extrema are placed very close to their correct positions and multiple extrema and high potential gradients are recovered. Identical conclusions are observed in the presence of noise and even when the Laplacians are subject to greater noise than the potentials.

Artifacts↗

Inverse electrocardiography by simultaneous imposition of multiple constraints.

We describe two new methods for the inverse problem of electrocardiography. Both employ regularization with multiple constraints, rather than the standard single-constraint regularization. In one method, multiple constraints on the spatial behavior of the solution are used simultaneously. In the other, spatial constraints are used simultaneously with constraints on the temporal behavior of the solution. The specific cases of two spatial constraints and one spatial and one temporal constraint are considered in detail. A new method, the L-Surface, is presented to guide the choice of the required pairs of regularization parameters. In the case when both spatial and temporal regularization are used simultaneously, there is an increased computational burden, and two methods are presented to compute solutions efficiently. The methods are verified by simulations using both dipole sources and measured canine epicardial data.

Animals↗

Comparison of doppler ultrasound and direct electrocardiography acquisition techniques for quantification of fetal heart rate variability.

A method for comparison of two acquisition techniques that are applied in clinical practice to provide information on fetal condition is presented. The aim of this work was to evaluate the commonly used Doppler ultrasound technique for monitoring of mechanical activity of fetal heart. Accuracy of beat-to-beat interval determination together with its influence on indices describing the fetal heart rate (FHR) variability calculated automatically using computer-aided fetal monitoring system were examined. We considered the direct fetal electrocardiography as a reference technique because it ensures the highest possible accuracy of heart interval measurement, and additionally all the definitions of popular time domain parameters quantifying FHR variability formerly have been created using the fetal electrocardiogram. We evaluated the reliability of various so called short-term and long-term variability indices, when they are calculated automatically using the signal obtained via the Doppler US from a fetal monitor. The results proved that evaluation of the acquisition technique influence on fetal well-being assessment can not be accomplished basing on direct measurements of heartbeats only. The more relevant is the estimation of accuracy of the variability indices, since analysis of their changes can significantly increase predictability of fetal distress.

Algorithms↗

Wavefront-based models for inverse electrocardiography.

We introduce two wavefront-based methods for the inverse problem of electrocardiography, which we term wavefront-based curve reconstruction (WBCR) and wavefront-based potential reconstruction (WBPR). In the WBCR approach, the epicardial activation wavefront is modeled as a curve evolving on the heart surface, with the evolution governed by factors derived phenomenologically from prior measured data. The body surface potential/wavefront relationship is modeled via an intermediate mapping of wavefront to epicardial potentials, again derived phenomenologically. In the WBPR approach, we iteratively construct an estimate of epicardial potentials from an estimated wavefront curve according to a simplified model and use it as an initial solution in a Tikhonov regularization scheme. Initial simulation results using measured canine epicardial data show considerable improvement in reconstructing activation wavefronts and epicardial potentials with respect to standard Tikhonov solutions. In particular the WBCR method accurately finds the anisotropic propagation early after epicardial pacing, and the WBPR method finds the wavefront (regions of sharp gradient of the potential) both accurately and with minimal smoothing.

Action Potentials↗

Improved performance of bayesian solutions for inverse electrocardiography using multiple information sources.

The usual goal in inverse electrocardiography (ECG) is to reconstruct cardiac electrical sources from body surface potentials and a mathematical model that relates the sources to the measurements. Due to attenuation and smoothing that occurs in the thorax, the inverse ECG problem is ill-posed and imposition of a priori constraints is needed to combat this ill-posedness. When the problem is posed in terms of reconstructing heart surface potentials, solutions have not yet achieved clinical utility; limitations include the limited availability of good a priori information about the solution and the lack of a "good" error metric. We describe an approach that combines body surface measurements and standard forward models with two additional information sources: statistical prior information about epicardial potential distributions and sparse simultaneous measurements of epicardial potentials made with multielectrode coronary venous catheters. We employ a Bayesian methodology which offers a general way to incorporate these information sources and additionally provides statistical performance analysis tools. In a simulation study, we first compare solutions using one or more of these information sources. Then, we study the effects of varying the number of sparse epicardial potential measurements on reconstruction accuracy. To evaluate accuracy, we used the Bayesian error covariance as well as traditional error metrics such as relative error. Our results show that including even sparsely sampled information from coronary venous catheters can substantially improve the reconstruction of epicardial potential distributions and that a Bayesian framework provides a feasible approach to using this information. Moreover, computing the Bayesian error standard deviations offers a means to indicate confidence in the results even in the absence of validation data.

Action Potentials↗

Role of electrophysiologic studies, signal-averaged electrocardiography, heart rate variability, T-wave alternans, and loop recorders for risk stratification of ventricular arrhythmias.

Ventricular tachycardia and fibrillation are major causes of morbidity and mortality after myocardial infarction. Frequently, sudden cardiac death is the first manifestation of such malignant rhythms. Optimal risk stratification strategies in this population are of utmost importance. In this review the authors discuss the background and clinical use of invasive tests, such as electrophysiologic study and implantable loop recorders, and noninvasive tests, such as signal-averaged electrocardiography, heart rate variability, and T-wave alternans. The utility, indications, and limitations of each test in clinical practice are discussed, especially for the purpose of postmyocardial infarction risk stratification in the elderly population.

Action Potentials↗

CVP catheter electrocardiography: an alternative to radiographic control after cannulation of central veins?

We evaluated 160 electrocardiograms taken after placement of central venous catheters (CVC) to determine their locations. Usable recordings were obtained in 154 patients. Subsequent radiographs revealed 30 misplaced catheters. Twenty-five of those were detected by CVC electrocardiograms. There were five false positive and five false negative traces. The sensitivity of CVC electrocardiography was 96%, the specificity 83.3%, and the total predictive power 93.5%. Electrocardiograms obtained from guide-wires were of significantly better quality than those from 0.9% NaCl filled catheters. The technique is accurate, safe and easy to learn. It may reduce the need for routine radiographic control to less than 10% of patients.

Adolescent↗

The value of exercise electrocardiography and exercise thallium-201 myocardial perfusion scanning in determining the presence of single vessel coronary artery obstruction.

In 39 patients with single vessel coronary artery disease and no previous myocardial infarction, exercise thallium-201 myocardial perfusion scanning and 12 lead exercise electrocardiography (ECG) were compared to see how reliably each method identified the site of coronary artery obstruction. Significant (greater than or equal to 70% diameter) stenosis was present in the left anterior descending (LAD) coronary artery in 21 patients, in the right coronary artery (RCA) in 14 patients and in the left circumflex (LCX) in four patients. Thallium defects on the scan in the septal (SEPT), anteroseptal (ANT SEPT) and anterior (ANT) segments correlated (P less than 0 . 0005) with LAD disease and defects in the inferior (INF), posteroinferior (POST INF), and posterior (POST) segments correlated (P less than 0 . 0005) with RCA or LCX disease. Exercise induced ST segment elevation in VI and/or AVL correlated with LAD disease. The site of ischaemic ST depression did not correlate with disease in any vessel. ST segment depression in leads L2, 3, AVF (67%) and in leads V4--6 (67%) was most sensitive for detecting patients with LAD disease and ST depression in leads V4--6 was most sensitive (56%) for detecting patients with RCA or LCX disease but neither differentiated LAD from RCA/LCX disease.

Adult↗

The prevalence of arrhythmias in hypertrophic cardiomyopathy: role of ambulatory monitoring and signal-averaged electrocardiography.

Hypertrophic cardiomyopathy (HCM) is associated with a high incidence of supraventricular and ventricular arrhythmias. The presence of ventricular tachycardia (VT) in patients with HCM has been associated with a high risk of sudden death. Forty-seven patients with HCM (31 male, 16 female, mean age 47 years) underwent continuous 24-hour ambulatory electrocardiographic (ECG) monitoring. High grade ventricular arrhythmias (modified Lown class 3, 4a, 4b) were found in 20 patients (43%) with VT in 11 (24%). In each case the arrhythmia was asymptomatic. Supraventricular arrhythmias were detected in 16 patients (34%). Signal-averaged electrocardiography in 27 patients showed late potentials in three of 11 patients with repetitive ventricular arrhythmias and was negative in 15 of 16 patients without these arrhythmias. In conclusion, asymptomatic high grade ventricular and supraventricular arrhythmias are common in HCM and are readily detected with continuous electrocardiographic monitoring. Signal-averaged ECG has low sensitivity for the detection of subclinical VT in patients with HCM.

Adolescent↗

Pacemaker electrocardiography of rate smoothing during DDD pacing.

A rate smoothing option is available in a new bipolar AV universal (DDD) pacemaker. In three patients, two with intact retrograde conduction and one with retrograde block, rate smoothing values of 3% and 6% were programmed. Irregular pacemaker-mediated tachycardia occurred in one patient and AV synchrony was temporarily lost in the other two patients. In this report, we describe the pacemaker electrocardiography of rate smoothing during DDD pacing.

Aged↗

High frequency electrocardiography of three orthogonal leads in dogs during a coronary artery occlusion.

The ability to detect cardiac ischemia in dogs was studied using high frequency electrocardiography and signal averaging technique. Ischemia was induced via a balloon occluding cuff placed around the left anterior descending coronary artery. Three surface orthogonal bipolar leads (X, Y, and Z) were recorded prior to inflation of the occluding cuff. The cuff was then inflated, causing a complete occlusion of the coronary artery. The surface electrocardiogram was recorded before and during ligation and during reperfusion. The recorded waveforms were divided into sequential 10-15 second segments representing different stages of the ischemic state and were aligned using cross-correlation scheme, averaged and band pass filtered between 150-250 Hz. Analysis of the filtered high frequency QRS complexes revealed that coronary ligation was accompanied by changes in waveform morphology including the appearance of zones of reduced amplitude. In seven out of ten experiments reduced amplitude zones were absent before the ligation, present during the occlusion and absent following reperfusion. In two experiments, reduced amplitude zones that were present prior to ligation became wider during occlusion. In one experiment no reduced amplitude zone was present during any stage of the experiment. Such zones may represent slow conduction in regions of the heart rendered ischemia during coronary ligation. Therefore, the morphology of the high frequency QRS complex, as determined by analysis of the signal averaged electrocardiogram, may provide useful information regarding the presence of myocardial ischemia.

Animals↗

Value of time- and frequency-domain analysis of signal-averaged electrocardiography for arrhythmia risk prediction in idiopathic dilated cardiomyopathy.

Signal-averaged electrocardiography (SAECG) was performed in 120 consecutive patients with idiopathic dilated cardiomyopathy (IDC), and in 60 healthy controls. Time-domain analysis of SAECGs revealed ventricular late potentials in 27 of 120 patients with IDC (23%) compared to 2 of 60 controls (3%; P < 0.05). Frequency-domain analysis of SAECGs showed ventricular late potentials in 9 of 120 patients with IDC (8%) compared to none of the 60 controls (0%, P < 0.05). During a prospective follow-up of 15 +/- 7 months, serious arrhythmic events, defined as sustained ventricular tachyarrhythmias or sudden death, occurred in 17 of 120 patients with IDC (14%). The sensitivity, specificity, and positive and negative predictive values of ventricular late potentials for serious arrhythmic events were 35%, 80%, 22%, and 88% for the time-domain analysis, and 18%, 94%, 33%, and 87% for the frequency-domain analysis of SAECG, respectively. Thus, neither the time-nor the frequency-domain analysis of SAECG appears to be useful for risk stratification in the setting of IDC in view of their low sensitivity and low positive predictive value for serious arrhythmic events during follow-up.

Action Potentials↗

Autonomic effects on noise recorded during signal-averaged electrocardiography.

The purpose of this study was to assess the effects of autonomic stimulation and blockade on noise levels and to compare the noise measurements in the ST and TP segments of the signal-averaged ECG. Five-minute electrocardiographic data were recorded in 14 normal volunteers (8 males and 6 females; mean age 28.5 +/- 5.0 years) on two separate days (day 1-baseline, epinephrine infusion, isoproterenol infusion, beta-blockade, and combined adrenergic and parasympathetic blockade; day 2-baseline, phenylephrine infusion, parasympathetic blockade, and during phenylephrine infusion following atropine). Signal averaging was done off-line on 100 beats and noise was measured in both the ST and TP segments as the standard deviation of voltage in the segment of interest. For all conditions tested, the mean noise level measured in the ST segment (0.46 +/- 0.16 microV) was significantly less than that measured in the TP segment (0.52 +/- 0.24 microV; P = 0.0003), but there was good correlation between the noise measured in the ST and the TP segment (R2 = 0.62, P < 0.0001). Noise increased with isoproterenol infusion and decreased following adrenergic blockade. In addition, day 2 baseline noise was less than baseline noise on day 1. Finally, neither parasympathetic stimulation or blockade nor alpha-adrenergic stimulation significantly affected signal-averaged electrocardiography (SAECG) noise levels. Thus, the data support the notion that enhanced sympathetic tone increases noise levels and beta-adrenergic blockade may decrease noise levels, likely due to effects from muscle sympathetic nerve activity. These findings are important since the target population for the SAECG are patients with myocardial infarction and congestive heart failure, conditions associated with increased sympathetic tone, which may in turn impact on the reproducibility or technical aspects of the SAECG. In addition, because noise in the ST and TP segments are highly correlated and the noise measured in the ST segment is less than that in the TP segment, uniform adoption of noise measurement in the ST segment seems most appropriate.

Adrenergic Antagonists↗

Ambulatory electrocardiography for the detection of pacemaker lead failure.

The suboptimal performance of some polyurethane bipolar pacing leads has highlighted concern about the optimal method of monitoring pacemaker lead performance. Since the manifestations of premature lead failure may be initially intermittent, we hypothesized that ambulatory electrocardiography (AECG) would be a more sensitive tool for the detection of pacing lead failure compared to increased pacemaker clinic surveillance. Since the Medtronic safety alerts on the 4012, 4082, and 4004 leads, we have followed 261 patients by serial AECG and 165 patients by increased pacemaker clinic surveillance. Lead failures were identified in 75 patients: 68 in the AECG group (31%) and 7 in the clinic group (4%, P < 0.001). Repeat AECG confirmed the lead failure in 38 (97%) of 39 patients in which it could be done. Pacing lead failure documented by AECG could be confirmed by a subsequent clinic assessment in only 15 (25%) of 60 patients evaluated (P < 0.001). The actuarial survival of the 4012 lead was significantly lower in the AECG group compared to the clinic group (56% vs 87% survival at 8 years, P < 0.002). Similar trends were observed for the 4082 and 4004 leads. AECG is a more sensitive method of surveillance for pacemaker lead function compared to pacemaker clinic assessment. AECG should be incorporated into the routine follow-up of pacemaker patients.

Aged↗

Noninvasive assessment of acute changes in atrial electrophysiology after cardioversion by signal-averaged P-wave electrocardiography.

BACKGROUND: Atrial remodeling secondary to atrial fibrillation (AF) may be important in the arrhythmogenic process. Unfortunately, the study of electrophysiologic remodeling in humans has been limited by the invasive nature of most tests of electrophysiologic characteristics. We sought to determine whether changes in atrial electrophysiology occur acutely (within the first hour) after cardioversion and whether these changes could be detected noninvasively by measuring the signal-averaged P-wave. METHODS: The filtered P-wave duration (FPD) was measured by signal-averaged electrocardiography (ECG) at 20 and 60 minutes after cardioversion in 46 patients with AF, and the difference between the two values was calculated. The root-mean-square voltage of the terminal 40 ms of the signal-averaged P-wave at 20 and 60 minutes and the difference between them were also determined. RESULTS: The FPD at 20 minutes was significantly different from that at 60 minutes (153.0 +/- 19.1 vs 159.7 +/- 24.8 ms; P = 0.02). In a univariate linear regression model, none of the clinical variables studied was significantly associated with the change in FPD. The root-mean-square voltage at 20 minutes was not significantly different from that at 60 minutes (5.8 +/- 3.0 vs 5.5 +/- 2.7; P = 0.14). CONCLUSIONS: We conclude that significant changes in atrial electrophysiology occur within the first hour after cardioversion of AF. These changes can be detected by measuring the FPD.

Aged↗

Efficiency and cost saving of 7 day per week exercise testing utilizing all electrocardiography technologists.

BACKGROUND: In most centers, exercise testing (ET) is performed by one or two trained technologists during the weekdays (0800 hours-1600 hours), leaving a void during evenings and weekends. This leads to unnecessary increased costs due to delays in management of patients. Electrocardiography technologists (ECGT) are often available for extended hours. This project was undertaken to improve the efficiency of the ET laboratory by using ECGT to perform ET during these extended hours. METHODS: Clinical utility and cost saving of a 7 day per week ET for management of patients with suspected and/or known coronary artery disease utilizing ECGT was assessed after adequate training. Of 4099 patients undergoing ET between January 1995 and December 1997, 810 tests performed by ECGT were reviewed retrospectively. RESULTS: Of the 810 patients (age mean 58.4 +/- 0.44 yrs; range 16-88; males: 508, females: 302), 806 (99.5%) underwent the Bruce protocol. The indications were: diagnostic, 61.3%, predischarge acute myocardial infarction (AMI), 17.7%, evaluation of angina, 19.6%, other, 1.4%. Only 8 (0.1%) patients had complications (prolonged chest pain, 6; nonsustained ventricular tachycardia, 2) with no AMIs or deaths. This strategy resulted in a savings of 158 bed days (Can189,600 dollars) on inpatients and 15 bed days (Can18,000 dollars) on those presenting to the emergency department. CONCLUSIONS: This study demonstrates the feasibility and safety of utilizing ECGT for ET thus extending the hours of service. This resulted in efficient patient management, with a considerable cost-saving to the hospital.

Adolescent↗

An admissible solution approach to inverse electrocardiography.

The goal of the inverse problem of electrocardiography is noninvasive discrimination and characterization of normal/abnormal cardiac electrical activity from measurements of body surface potentials. Smoothing and attenuation in the torso volume conductor cause the problem to be ill posed. Standard regularized solutions employ an a priori constraint to achieve reliability and may be biased by the constraint chosen as well as the regularization parameter used to weight it. In this paper, we describe an approach that reformulates this inverse problem as the search for a solution that is a member of an admissible solution set; admissibility is defined in terms of the available constraints. In principle, this approach can utilize as many constraints as may be available, unlike standard techniques which do not easily permit the use of multiple constraints. No regularization parameter is required; instead, we need to choose the nature and size of the constraint sets. Constraints described include several spatial constraints, weighted constraints, and temporal constraints. We describe a solution approach based on iterative convex optimization, and the algorithm--the ellipsoid algorithm--which we have used. Accuracy and feasibility of the method are illustrated with simulation results using dipole sources and measured epicardial potentials.

Algorithms↗

Transient abnormal Q waves during exercise electrocardiography.

Myocardial ischaemia during exercise electrocardiography is usually manifested by ST segment depression or elevation. Transient abnormal Q waves are rare, as Q waves indicate an old myocardial infarction. The case of a patient with exercise induced transient abnormal Q waves is reported. The potential mechanisms involved in the development of such an abnormality and its clinical implications are discussed.

Aged↗