At least 379 records · Page 21Linked to original sources

Visualizing T cell migration in vivo.

Ever since the realization that T lymphocytes are key players in the defense against pathogens and tumors, a major aim of immunologists has been to understand the relationship between the functional and migratory properties of antigen-specific T cells. The current paradigm proposes that T cells follow organ-specific trafficking pathways to exit from blood into the extravascular compartment. T cell homing is regulated at the level of adhesion molecules and chemokine receptors, whose expression is linked tightly to the differentiation state of the cell. Naïve T lymphocytes follow relatively uniform recirculation routes through secondary lymphoid organs, the molecular cues of which are fairly well understood. As effector and memory T cells must be capable of reaching virtually any site in the body, their migratory behavior is considerably more heterogeneous. During the past few years, innovative approaches for tracking T cells in vivo have emerged. Here, we review recent technical developments in experimental methods for the visualization of T cells both at the population and single cell level in vivo, and discuss what these methods have taught us about T cell trafficking.

Animals↗

Two-photon microscopy for imaging of the (atherosclerotic) vascular wall: a proof of concept study.

BACKGROUND: Understanding atherogenesis will benefit significantly from simultaneous imaging, both ex vivo and in vivo, of structural and functional information at the (sub)cellular level within intact arteries. Due to limited penetration depth and loss of resolution with depth, intravital and confocal fluorescence microscopy are not suitable to study (sub)cellular details in arteries with wall thicknesses above 50 microm. METHODS: Using two-photon laser scanning microscopy (TPLSM), which combines 3D resolution and large penetration depth, we imaged mouse carotid arteries. RESULTS: In thin slices, (sub)cellular structures identified using histochemical techniques could also be identified using TPLSM. Ex vivo, structural experiments on intact atherosclerotic arteries of Apo-E(-/-) mice demonstrated that in contrast to confocal or wide-field microscopy, TPLSM can be used to visualize (sub) cellular structural details of atherosclerotic plaques. In vivo, pilot experiments were carried out on healthy arteries of wild-type C57BL6 and atherosclerotic arteries of Apo-E(-/-) mice. As an example of functional measurements, we visualized fluorescently labeled leukocytes in vivo in the lumen. Additionally, detailed morphological information of vessel wall and atherosclerotic plaque was obtained after topical staining. CONCLUSIONS: Thus, TPLSM potentially allows combined functional and structural studies and can therefore be eminently suitable for investigating structure-function relationships at the cellular level in atherogenesis in the mouse.

Animals↗

Imaging glomeruli in renal biopsy specimens.

Glomerular capillary loops are complex vascular filters composed of interdigitating podocytes and fenestrated endothelial cells with an intervening proteoglycan-rich extracellular matrix. This arrangement is crucial to maintaining the filtration barrier but renders the glomerulus difficult to analyze by conventional two-dimensional histochemical techniques. When pathologic lesions distort glomerular architecture, its complex morphology is even more challenging to interpret. Fortunately, recent advances in microscopes and computer software now enable glomerular enthusiasts to dissect this complex structure with finer detail. In this review we explore the application of new methodologies such as two-photon microscopy that optimize three-dimensional, multicolor imaging and single-cell segmentation of glomerular components.

Animals↗

Two-photon microscopy of vital murine elastic and muscular arteries. Combined structural and functional imaging with subcellular resolution.

Understanding vascular pathologies requires insight in the structure and function, and, hence, an imaging technique combining subcellular resolution, large penetration depth, and optical sectioning. We evaluated the applicability of two-photon laser-scanning microscopy (TPLSM) in large elastic and small muscular arteries under physiological conditions. Elastic (carotid) and muscular (uterine, mesenteric) arteries of C57BL/6 mice were mounted in a perfusion chamber. TPLSM was used to assess the viability of arteries and to visualize the structural components elastin, collagen, nuclei, and endothelial glycocalyx (EG). Functionality was determined using diameter changes in response to noradrenaline and acetylcholine. Viability and functionality were maintained up to 4 h, enabling the assessment of structure-function relationships. Structural vessel wall components differed between elastic and muscular arteries: size (1.3 vs. 2.1 microm) and density (0.045 vs. 0.57 microm(-2)) of internal elastic lamina fenestrae, smooth muscle cell density (3.50 vs. 1.53 microm(-3)), number of elastic laminae (3 vs. 2), and adventitial collagen structure (tortuous vs. straight). EG in elastic arteries was 4.5 microm thick, covering 66% of the endothelial surface. TPLSM enables visualization and quantification of subcellular structures in vital and functional elastic and muscular murine arteries, allowing unraveling of structure-function relationships in healthy and diseased arteries.

Acetylcholine↗

Two-photon microscopy of cells and tissue.

Two-photon excitation fluorescence imaging provides thin optical sections from deep within thick, scattering specimens by way of restricting fluorophore excitation (and thus emission) to the focal plane of the microscope. Spatial confinement of two-photon excitation gives rise to several advantages over single-photon confocal microscopy. First, penetration depth of the excitation beam is increased. Second, because out-of-focus fluorescence is never generated, no pinhole is necessary in the detection path of the microscope, resulting in increased fluorescence collection efficiency. Third, two-photon excitation markedly reduces overall photobleaching and photodamage, resulting in extended viability of biological specimens during long-term imaging. Finally, localized excitation can be used for photolysis of caged compounds in femtoliter volumes and for diffusion measurements by two-photon fluorescence photobleaching recovery. This review aims to provide an overview of the use of two-photon excitation microscopy. Selected applications of this technique will illustrate its excellent suitability to assess cellular and subcellular events in intact, strongly scattering tissue. In particular, its capability to resolve differences in calcium dynamics between individual cardiomyocytes deep within intact, buffer-perfused hearts is demonstrated. Potential applications of two-photon laser scanning microscopy as applied to integrative cardiac physiology are pointed out.

Animals↗

A review of potential new diagnostic modalities for caries lesions.

This paper aims to present a simple overview of potential new diagnostic methods for dental caries. There are several novel methods of caries detection (with potential application to diagnosis) which have been proposed in the last few years, in addition to those that are gaining some commercial exposure and clinical acceptance. For the most part, these methods have been demonstrated in laboratories and are generally many years away from routine clinical application. They include multi-photon imaging, infrared thermography and infrared fluorescence, optical coherence tomography, ultrasound, and terahertz imaging.

Dental Caries↗

An algorithm for automatic evaluation of the spot quality in two-color DNA microarray experiments.

BACKGROUND: Although DNA microarray technologies are very powerful for the simultaneous quantitative characterization of thousands of genes, the quality of the obtained experimental data is often far from ideal. The measured microarrays images represent a regular collection of spots, and the intensity of light at each spot is proportional to the DNA copy number or to the expression level of the gene whose DNA clone is spotted. Spot quality control is an essential part of microarray image analysis, which must be carried out at the level of individual spot identification. The problem is difficult to formalize due to the diversity of instrumental and biological factors that can influence the result. RESULTS: For each spot we estimate the ratio of measured fluorescence intensities revealing differential gene expression or change in DNA copy numbers between the test and control samples. We also define a set of quality characteristics and a model for combining these characteristics into an overall spot quality value. We have developed a training procedure to evaluate the contribution of each individual characteristic in the overall quality. This procedure uses information available from replicated spots, located in the same array or over a set of replicated arrays. It is assumed that unspoiled replicated spots must have very close ratios, whereas poor spots yield greater diversity in the obtained ratio estimates. CONCLUSION: The developed procedure provides an automatic tool to quantify spot quality and to identify different types of spot deficiency occurring in DNA microarray technology. Quality values assigned to each spot can be used either to eliminate spots or to weight contribution of each ratio estimate in follow-up analysis procedures.

Algorithms↗

Goulphar: rapid access and expertise for standard two-color microarray normalization methods.

BACKGROUND: Raw data normalization is a critical step in microarray data analysis because it directly affects data interpretation. Most of the normalization methods currently used are included in the R/BioConductor packages but it is often difficult to identify the most appropriate method. Furthermore, the use of R commands for functions and graphics can introduce mistakes that are difficult to trace. We present here a script written in R that provides a flexible means of access to and monitoring of data normalization for two-color microarrays. This script combines the power of BioConductor and R analysis functions and reduces the amount of R programming required. RESULTS: Goulphar was developed in and runs using the R language and environment. It combines and extends functions found in BioConductor packages (limma and marray) to correct for dye biases and spatial artifacts. Goulphar provides a wide range of optional and customizable filters for excluding incorrect signals during the pre-processing step. It displays informative output plots, enabling the user to monitor the normalization process, and helps adapt the normalization method appropriately to the data. All these analyses and graphical outputs are presented in a single PDF report. CONCLUSION: Goulphar provides simple, rapid access to the power of the R/BioConductor statistical analysis packages, with precise control and visualization of the results obtained. Complete documentation, examples and online forms for setting script parameters are available from http://transcriptome.ens.fr/goulphar/.

Algorithms↗

Multi-photon excitation microscopy.

Multi-photon excitation (MPE) microscopy plays a growing role among microscopical techniques utilized for studying biological matter. In conjunction with confocal microscopy it can be considered the imaging workhorse of life science laboratories. Its roots can be found in a fundamental work written by Maria Goeppert Mayer more than 70 years ago. Nowadays, 2PE and MPE microscopes are expected to increase their impact in areas such biotechnology, neurobiology, embryology, tissue engineering, materials science where imaging can be coupled to the possibility of using the microscopes in an active way, too. As well, 2PE implementations in noninvasive optical bioscopy or laser-based treatments point out to the relevance in clinical applications. Here we report about some basic aspects related to the phenomenon, implications in three-dimensional imaging microscopy, practical aspects related to design and realization of MPE microscopes, and we only give a list of potential applications and variations on the theme in order to offer a starting point for advancing new applications and developments.

Animals↗

[Real-time imaging of local Ca2+ signaling in single neurons].

In addition to the multiple mechanisms of the intracellular calcium mobilizing pathways, neurons possess multiple functional compartments such as the soma, the axon, the dendrites, and the spines. In this article, technical procedures and tips are described to measure local calcium signaling in response to neuronal excitation in single neurons.

Animals↗

Optical bioimaging: from living tissue to a single molecule: calcium imaging in blood vessel in situ employing two-photon excitation fluorescence microscopy.

Recent developments in optoelectronics permit real-time Ca(2+) imaging of thin planes within cells utilizing laser scanning confocal microscopy (LSCM). However, a major complication associated with this imaging system involves increased phototoxicity with improved spatiotemporal resolution. Two-photon excitation microscopy (TPEM) helps to minimize phototoxicity due to the restriction of this technique to the volume proximal to the geometric focus of the light. In this study, the capability of Ca(2+) imaging was investigated employing recently developed real-time TPEM, RTS2000MP (Bio-Rad, Tokyo) with a mode-locked Ti-sapphire laser. Z-axis resolution of RTS2000MP with high NA objectives defined as full-width at half maximum (FWHM) with a 0.5-microm fluorescent bead provided values nearly identical to those obtained with LSCM at a small pinhole (0.2 mm) (approximately 0.6 microm). When serial sectioning of 21 sequential images at 0.3-microm intervals in cultured endothelial cells loaded with calcein and tetramethyl-rhodamine methylester were performed with TPEM, the z-axis resolution was higher than that observed with LSCM; moreover, the photobleaching rate was significantly lower than that obtained with LSCM. Maximum fluorescence intensities were detected at 780 nm in excitation spectra of fluo-3 and fluo-4 Ca(2+)-sensitive probes with TPEM. Fluorescence images in mouse arterial endothelial cells loaded with fluo-4 could be clearly visualized by TPEM in situ. Application of acetylcholine caused oscillatory increase in [Ca(2+)](i) of endothelial cells; subsequently, relaxation along the major axis of smooth muscle cells was evident. Furthermore, consecutive long-lasting experiments could be repeated with identical response in the same microscopic field. In conclusion, fluorescence imaging employing TPEM is useful for Ca(2+) imaging in blood vessels in situ.

Animals↗

Simultaneous two-photon spectral and lifetime fluorescence microscopy.

When a fluorescence photon is emitted from a molecule within a living cell it carries a signature that can potentially identify the molecule and provide information on the microenvironment in which it resides, thereby providing insights into the physiology of the cell. To unambiguously identify fluorescent probes and monitor their physiological environment within living specimens by their fluorescent signatures, one must exploit as much of this information as possible. We describe the development and implementation of a combined two-photon spectral and lifetime microscope. Fluorescence lifetime images from 16 individual wavelength components of the emission spectrum can be acquired with 10-nm resolution on a pixel-by-pixel basis. The instrument provides a unique visualization of cellular structures and processes through spectrally and temporally resolved information and may ultimately find applications in live cell and tissue imaging.

Animals↗

Geometric determination of saturation in fluorescence spectroscopy.

In laser spectroscopy, saturation of atomic or molecular transitions cannot be ignored, even at modest laser intensities. The saturation status is customarily diagnosed from measurements of saturation curves describing the dependence of spectroscopic signals on laser intensity. I propose an alternative method that relies on a geometric comparison of the spatial laser profile with images of the spectroscopic quantity under investigation. A single image can be used to determine the saturation status and its associated saturation laser intensity.

Algorithms↗

Excited-state absorption and anisotropy properties of two-photon absorbing fluorene derivatives.

The electronic structure of fluorene derivatives N-(7-benzothiazol-2-yl-9,9-bis-decyl-9H-fluoren-2-yl)-acetamide (1); 9,9-didecyl-2,7-bis-(N,N-benzothiazoyl)fluorene (2); 4,4'-{[9,9-bis(ethyl)-9H-fluorene-2,7-diyl]di-2,1-ethenediyl}bis(N,N-diphenyl)benzeneamine (3); and 4,4',4"{[9,9-bis(ethyl)-9H-fluorene-2,4,7-triyl]tri-2,1-ethenediyl}tris(N,N-diphenyl)benzeneamine (4) were investigated by a steady-state spectral technique, quantum-chemical calculations, and a picosecond pump-probe method. These derivatives are of interest for their relatively high two-photon absorption. The steady-state excitation anisotropy spectra reveal the nature of the ground-state absorption bands. Semiempirical quantum-chemical calculations of the fluorene derivatives (AM1, ZINDO/S) show good agreement with experimental data. The spectral positions and alignment of various electronic transitions of derivatives 1-4 were estimated from their excited-state absorption and anisotropy spectra.

Absorption↗

Subnanosecond-resolution phase-resolved fluorescence imaging technique for biomedical applications.

Characterization of fluorescence emissions from cells often leads to conclusive results in the early detection of cellular abnormalities. Cellular abnormalities can be characterized by their difference in the fluorescence lifetime, which may be less than nanoseconds. A sensitive frequency domain technique, also called a phase-resolved fluorescence imaging technique, is proposed in which fluorescence emissions at the same wavelengths can more effectively be separated with subnanosecond resolution in their lifetime difference. The system configuration is optimized by incorporating even-step phase shifting in the homodyne-assisted signal-processing concept along with the phase-resolved fluorescence technique to eliminate the dc offsets of emission. Experiments are carried out with simulated samples composed of two fluorescence emissions of the same wavelength but with different lifetime values. Suppression of either of the fluorescence emissions by selective imaging of the other validates the superiority of the proposed technique. Hence, this technique can potentially be applied in the early detection of cellular abnormalities.

Biomedical Engineering↗

Two-photon excitation fluorescence microscopy with a high depth of field using an axicon.

In conventional two-photon excitation fluorescence microscopy, the numerical aperture of the objective determines the lateral resolution and the depth of field. In some situations, as with functional imaging of dynamic events distributed in live biological tissue, an improved temporal resolution is needed; as a consequence, it is imperative to use optics with a high depth of field to simultaneously image objects at different axial positions. With a conventional microscope objective, increasing the depth of field is achieved at the expense of lateral resolution. To overcome this limitation, we have incorporated an axicon in a two-photon excitation fluorescence microscopy system; measurements have shown that an axicon provides a depth of field in excess of a millimeter, while the lateral resolution is maintained at the micrometer scale. Thus axicon-based two-photon microscopy has been shown to yield a high-resolution projection image of a sample with a single 2D scan of the laser beam while maintaining the improved tissue penetration typical of two-photon microscopy.

Equipment Design↗

On the fundamental imaging-depth limit in two-photon microscopy.

We have analyzed how the maximal imaging depth of two-photon microscopy in scattering samples depends on properties of the sample and the imaging system. We find that the imaging depth increases with increasing numerical aperture and staining inhomogeneity and with decreasing excitation-pulse duration and scattering anisotropy factor, but is ultimately limited by near-surface fluorescence with slight improvements possible using special detection strategies.

Algorithms↗

Two-color two-photon 4Pi fluorescence microscopy.

In 4Pi fluorescence microscopy the point-spread function is composed of a strong central lobe accompanied by interference sidelobes that produce artifacts in the image. We propose to combine two-color two-photon fluorescence microscopy and 4Pi fluorescence microscopy to overcome this sidelobe problem. Simulation results show that a single sharp fluorescence spot can be produced by use of two excitation wavelengths of 400 and 800 nm and detected at 350-nm emission wavelength.

Equipment Design↗