PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polymers”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Polymers of sodium-N-undec-10-ene-1-oyl taurate and sodium-N-undec-10-ene-1-oyl aminoethyl-2-phosphonate as pseudostationary phases for electrokinetic chromatography.

The use of micelle polymers, a class of polysoaps with a polymerized hydrophobic interior and a charged hydrophillic exterior, as pseudostationary phases in electrokinetic chromatography has generated significant interest. Their stable structure has been shown to provide significant advantages over conventional micelles when used as pseudostationary phases. In previous studies, micelle polymers have had carboxylate and sulfate head groups. These chemistries have limitations: carboxylate micelle polymers precipitate out of solution at pH less than seven or eight and sulfate head groups are not stable to hydrolysis and are hydrolyzed during polymerization. Additionally, while the chemical selectivity of conventional micelles varies with head group chemistry, no significant differences in chemical selectivity were observed between analogous polymers with sulfate and carboxylate groups. To overcome the limitations of carboxylate and sulfate head groups, and to further investigate the chemical selectivity of micelle polymers, poly(sodium-N-undec-10-ene-1-oyl-taurate) and poly(sodium-N-undec-10-ene-1-oyl-ethyl-2-phosphonate) micellar polymers have been synthesized and characterized as pseudostationary phases. These polymers have amide functionality and stable, strongly acidic sulfonate and phosphonate head groups. These polymers did provide improved solubility at low pH, and are stable under the conditions studied. The chromatographic performance and chemical selectivity of the polymers has been studied by several methods, including linear solvation energy relationships. Poly(sodiumN-undec-10-ene-1-oyl-taurate) has greater electrophoretic mobility than other polymers of this type, and can be used for the separation of hydrophobic compounds. The polymers do exhibit unique selectivity, but the differences in selectivity are not significant for the majority of compounds studied.

Aminoethylphosphonic Acid↗

The kinetics of baboon fibrinogen adsorption to polymers: in vitro and in vivo studies.

Fibrinogen adsorption on polymers from blood may mediate or potentiate thrombosis because of its involvement in both the intrinsic clotting system and the formation of platelet aggregates. While the kinetics of fibrinogen adsorption from plasma in vitro have previously been found to be very different on polar and nonpolar surfaces [T. A Horbett, "The kinetics of adsorption of plasma proteins to a series of hydrophilic-hydrophobic copolymers," ACS Org. Coat. Plas. Chem. 40, 642-646 (1979)] the significance of this difference with respect to thrombogenesis in vivo has not been clarified. In this study, the kinetics of deposition of baboon 125I fibrinogen from plasma in vitro or from blood in vivo on a series of polymers was measured. The polymers chosen for this study had previously been found to have a large range in surface polarity and reactivity in the in vivo baboon shunt model. The kinetics of fibrinogen adsorption in vitro were observed to be of three types, depending on the polymer: high initial adsorption decreasing to a lower steady state value; constant throughout the time course; low initial adsorption rising steadily to a plateau value. In vivo, fibrinogen deposition kinetics were of two types: low, constant deposition throughout the time course, independent of heparinization; low deposition initially followed by a second phase of greatly increased deposition (probably as fibrin) which was prevented or greatly decreased by heparinizing the animals. Polymers for which fibrinogen adsorption increased to a plateau in vitro were found to have a heparin inhibitable second phase of enhanced in vivo fibrinogen deposition. These polymers also have been found in previous studies to enhance the rate of platelet destruction when used as in vivo shunts on baboons. Conversely, most polymers with high initial in vitro fibrinogen adsorption followed by a decrease had low fibrinogen deposition behavior in vivo and were also minimally destructive of platelets. The adsorption kinetics of fibrinogen to polymers from blood in vivo and in vitro and the consumption of platelets in vivo induced by the polymers all vary with polymer polarity. More polar polymers had in vitro fibrinogen kinetics characterized by a rise to a plateau, in vivo fibrinogen deposition characterized by a second stage of great increase inhibitable by heparin, and enhanced platelet consumption. The correlation of three separate indicators of surface thrombogenicity with surface polarity suggests that more polar materials may be more thrombogenic because of an influence on the way in which fibrinogen interacts with these surfaces.

Adsorption↗

Enhanced gene expression through temperature profile-induced variations in molecular architecture of thermoresponsive polymer vectors.

BACKGROUND: Successful non-viral gene targeting requires vectors to meet two conflicting needs-strong binding to protect the genetic material during transit and weak binding at the target site to enable release. Responsive polymers could fulfil such requirements through the switching of states, e.g. the chain-extended coil to chain-collapsed globule phase transition that occurs at a lower critical solution temperature (LCST), in order to transport nucleic acid in one polymer state and release it in another. METHODS: The ability of new synthetic polycations based on poly(ethyleneimine) (PEI) with grafted neutral responsive poly(N-isopropylacrylamide) (PNIPAm) chains to condense DNA into particles with architectures varying according to graft polymer LCST was assessed using a combination of fluorescence spectroscopy, dynamic light scattering (DLS), zeta sizing, gel retardation and atomic force microscopy studies. Transfection assays were conducted under experimental conditions wherein the polymer components were able to cycle across their LCST. RESULTS: Two PEI-PNIPAm conjugate polymers with different LCSTs displayed coil-globule transitions when complexed to plasmid DNA, leading to variations in molecular architecture as shown by changes in emission maxima of an environment-sensitive fluorophore attached to the PNIPAm chains. Gel retardation assays demonstrated differences in electrophoretic mobilities of polymer-DNA complexes with temperatures below and above polymer LCSTs. Atomic force micrographs showed changes in the structures of polymer-DNA complexes for a polymer undergoing a phase transition around body temperature but not for the polymer with LCST outside this range. Transfection experiments in C2C12 and COS-7 cells demonstrated that the highest expression of transgene occurred in an assay that involved a 'cold-shock' below polymer LCST during transfection. CONCLUSIONS: Designed changes in thermoresponsive polycation vector configuration via temperature-induced phase transitions enhanced transgene expression. The results indicate that changes in molecular architecture induced by a carefully chosen stimulus during intracellular trafficking can be used to enhance gene delivery.

Acrylic Resins↗

Fourier transform Raman spectroscopic study of the interaction of water vapor with amorphous polymers.

Water associated with amorphous polymers is known to affect their chemical and physical properties. The purpose of this study was to investigate the nature of water-polymer interactions for some polymers of pharmaceutical interest. Using Raman spectroscopy, polymer-water hydrogen bond interactions were probed for two molecular weight grades of poly(vinylpyrrolidone), namely PVP K90 and PVP K12, and also for poly(vinylacetate) and poly(vinyl pyrrolidone-co-vinyl acetate). Water vapor absorption isotherms were obtained for the polymers, and the effect of the absorbed water on the glass transition temperature was determined. A knowledge of the water content and physical state of the polymer was used to aid interpretation of Raman spectral changes. The strength of the hydrogen bond formed with water was found to depend on the chemistry of the polymer, with the pyrrolidone group interacting more strongly than the acetate group. However, minor differences were also observed between the degree of interaction of water and polymer for PVP K12 and PVP K90 at some water contents. This result is attributed to differences in the structural relaxation changes accompanying plasticization by water for the two molecular weight grades. Using principal components analysis of the spectral data, it was also possible to differentiate between samples in the rubbery state and samples in the glassy state. In conclusion, water sorbed into polymers causes changes in the polymer Raman spectra not only because of hydrogen bonding, but also as a result of the plasticizing effect of water on polymer mobility.

Hydrogen Bonding↗

Complement activation by polymer binding IgG.

It was found that immobilized IgG on polymer carriers activates complement on contact with the serum. As polymers were microspherical in this study, complement fragments bound to polymers were detected by the agglutination of the polymer microspheres with the corresponding antisera or rosette formation with cells having complement receptors. Without the immobilization of IgG, polymers having amino, carboxyl, cyano or phenyl groups activated complement in the serum, while the presence of hydroxyl and carbamoyl groups in polymers did not cause complement activation. When intact IgG was bound to poly(glyceryl methacrylate) by the use of glutaraldehyde, the IgG-polymer conjugate activated complement in spite of the inertness of the polymer itself. The polymers immobilizing F(ab')2 activated complement less than the polymers immobilizing intact IgG. When dextran aldehyde prepared by periodate oxidation of dextran was used as a binder instead of glutaraldehyde, complement activation by F(ab')2-polymer conjugate was remarkably reduced, though antibody activity for binding the antigen remained. These results should be taken into consideration in the design of an immunosorption therapy.

Animals↗

Use of surfactants as plasticizers in preparing solid dispersions of poorly soluble API: selection of polymer-surfactant combinations using solubility parameters and testing the processability.

Formation of solid dispersions as a means to enhance the dissolution rate of poorly soluble Active pharmaceutical ingredients (APIs) typically employs hydrophilic polymer systems and surfactants. While the utility of the surfactant systems in solubilization is well known, the secondary effects of the same on processing and subsequent physical stability of the solid dispersions needs to be studied further. Physical blends of the poorly soluble API and hydrophilic polymers such as PVP-K30, Plasdone-S630, HPMC-E5, HPMCAS, and Eudragit L100 with mass ratio 1:1 were prepared. The surfactants tested in this study included Tween-80, Docusate sodium, Myrj-52, Pluronic-F68 and SLS. Thermal analysis of the API-polymer-surfactant blends suggested that the surfactants caused solvation/plasticization, manifesting in reduction of (i) the melting (T(m)) of API (ii) T(g) of the polymers and (iii) the combined T(g) of the solid dispersion formed from quench cooling. Explanation of these effects of surfactants is attempted based on their physical state (at the temperature of interest), HLB values and similarity of their solubility parameter values with respect to drug-polymer systems. Furthermore, extruded matrices containing different API-polymer (PVP-K30, Plasdone-S630, and HPMC-E5) mixtures prepared with and without surfactants, were produced by feeding the powder blend through a hot-melt extruder. The melt viscosity of the polymer blends was assessed by torque rheometry using a Haake Rheomix. The physicochemical properties of the extruded API-polymer-surfactant were characterized by differential scanning calorimetry, X-ray diffraction, Raman spectroscopy, and polarized microscopy. The results demonstrated that the glass transition temperature of the carrier polymers decreased as direct result of the surfactants in the extrudate, due to an increase in the chain mobility of polymers. A decrease in the melt viscosity was seen due to a plasticization of the polymer. The drug release profiles of the extruded solid dispersions containing intra granular surfactants were found to fit the dispersions with extra granularly added surfactants.

Calorimetry, Differential Scanning↗

Protein adsorption on surfaces with grafted polymers: a theoretical approach.

A general theoretical framework for studying the adsorption of protein molecules on surfaces with grafted polymers is presented. The approach is a generalization of the single-chain mean-field theory, in which the grafted polymer-protein-solvent layer is assumed to be inhomogeneous in the direction perpendicular to the grafting surface. The theory enables the calculation of the adsorption isotherms of the protein as a function of the surface coverage of grafted polymers, concentration of protein in bulk, and type of solvent molecules. The potentials of mean force of the protein with the surface are calculated as a function of polymer surface coverage and amount of protein adsorbed. The theory is applied to model lysozyme on surfaces with grafted polyethylene oxide. The protein is modeled as spherical in solution, and it is assumed that the protein-polymer, protein-solvent, and polymer-solvent attractive interactions are all equal. Therefore, the interactions determining the structure of the layer (beyond the bare polymer-surface and protein-surface interactions) are purely repulsive. The bare surface-protein interaction is taken from atomistic calculations by Lee and Park. For surfaces that do not have preferential attractions with the grafted polymer segments, the adsorption isotherms of lysozyme are independent of the polymer length for chains with more than 50 ethylene oxide units. However, the potentials of mean force show strong variations with grafted polymer molecular weight. The competition between different conformations of the adsorbed protein is studied in detail. The adsorption isotherms change qualitatively for surfaces with attractive interactions with ethylene oxide monomers. The protein adsorption is a function of chain length--the longer the polymer the more effective it is in preventing protein adsorption. The structure of the layer and its deformation upon protein adsorption are very important in determining the adsorption isotherms and the potentials of mean force.

Adsorption↗

Influence of mobile phase composition and cross-linking density on the enantiomeric recognition properties of molecularly imprinted polymers.

A series of experiments were conducted to investigate elements which affect the enantiomeric recognition properties of molecularly imprinted polymers (MIPs) in the HPLC mode. Our results show that the recognition properties of MIPs are greatly influenced by the mobile phase used. For a polymer prepared in acetonitrile, a good enantiomeric separation was observed when acetonitrile-based mobile phase was used, when the mobile phase was changed to chloroform-based, no enantiomeric recognition was observed although the sample molecule was retarded. This indicates that the specific co-operative binding interactions between the functional groups at the imprinted polymer's recognition sites and the sample molecule were considerably disrupted and only non-specific interactions remained. When the mobile phase was changed back to acetonitrile-based, the recognition was regained. In contrast, for polymers prepared in chloroform, chloroform-based mobile phase gave much better separation than acetonitrile-based mobile phase. When other solvents were tested, significant solvent effects were generally observed. Based on these observations, the recognition properties of the methacrylic acid (MAA)-co-ethylene glycol dimethacrylate (EGDMA) polymers were reinvestigated, and the results show that by simply using an optimised mobile phase system, significantly improved recognition over previously reported results was observed. For a polymer made against Cbz-L-Trp, 100 microg of Cbz-D,L-Trp was separated with a separation factor (alpha) of 4.23 and a resolution (Rs) of 3.87, whereas in the previous report, 10 microg of Cbz-D,L-Trp was only separated with alpha = 1.67 and Rs = 0.1. It is generally realised that the imprinted polymer's recognition property is also very much influenced by the nature of the polymer network. It was shown that the recognition decreased with a decrease in the apparent degree of cross-linking (molar percentage of cross-linker in the polymerisation mixture). Nonetheless, our results show that in our optimised assay system a significant separation could still be obtained on a polymer which was only 22% cross-linked. We consider this to be of importance, since it may suggest a way of imprinting larger molecules because of the possibly improved mass transfer in low cross-linking density polymers. It was reported that when trifunctional cross-linkers [for example: trimethylolpropane trimethacrylate (TRIM)] were used as the cross-linker instead of EGDMA, considerably improved enantiomeric separation and resolving capability were observed. Our results show that the improved performance of the MAA-co-EGDMA MIPs is actually comparable to the performance of the MIPs prepared with those trifunctional cross-linkers. The combination of a hydrogen bonding functional monomer (acrylamide) with TRIM also did not give improved recognition. The results suggest that although the three-dimensional network of these two kinds of polymer may be quite different, the observed recognition improvements were probably largely due to solvent effect.

Chromatography, High Pressure Liquid↗

Development of multicomponent DNA delivery systems based upon poly(amidoamine)-PEG co-polymers.

PEGylated polyamidoamine (PAA) polymers were investigated for the production of sterically stabilised DNA delivery systems. Comparison of a PEGylated polymer (NG47) with a non-PEGylated polymer (NG49) showed similar binding of co-polymer to DNA by displacement of ethidium bromide (EB) and DNA melting studies. Gel electrophoresis, turbidimetric analysis and PCS demonstrated differences in the colloidal properties of the complexes, which were attributable to the formation of soluble complexes by the PEGylated co-polymer. However, transmission electron microscopy (TEM) showed that the resulting complexes containing poly(ethylene glycol) (PEG) were not well condensed, susceptible to degradation by nucleases, and thus not suited for in vivo delivery. The poor properties of the PEGylated co-polymer were attributed to an excess of PEG. However, polymer blends of NG47 and NG49 at defined ratios of polymer to co-polymer and total repeating units (RUs) to nucleotide, spontaneously formed complexes with a range of desirable properties. These included small size and polydispersity, high particle density, low surface charge and resistance to nuclease degradation. Complexes made with PEGylated polymer alone, and the polymer blends both suffered from a reduced polyfection activity. This was attributed to a low surface charge on the complex, which reduced interactions with the cell membrane and consequent uptake of the particles into the cell.

Animals↗

The intracerebral administration of phenytoin using controlled-release polymers reduces experimental seizures in rats.

PURPOSE: An alternative strategy for the treatment of intractable seizures may be to administer anticonvulsants directly into the brain near the site of a seizure focus using controlled-release polymers. We describe the pharmacokinetics of a phenytoin-ethylene-vinyl acetate (EVAc) controlled-release polymer and report the reduction of seizures in a cobalt-induced rat model of epilepsy with the intracerebral delivery of phenytoin using surgically implanted polymers. METHODS: In the pharmacokinetics study, the drug release rate of 50%-loaded phenytoin-EVAc polymers (n=3) was determined in vitro over 15 weeks initially and then several months later (over a 2-week period after 1 year of in vivo release). In the efficacy study, 85 rats underwent implantation of skull-mounted cortical electrodes for electrocorticography (ECoG) and then underwent application of cobalt chloride to the cerebral cortex for the induction of seizures. Rats in the treatment group (n=9) underwent surgical implantation of phenytoin-EVAc polymers and rats in the control group (n=10) underwent implantation of empty EVAc polymers. In the morbidity study, the potential histologic pathology of the intracerebral delivery of increasing doses of phenytoin from the polymer (10, 20, 30, and 50% loading) was assessed. RESULTS: Phenytoin was released in vitro from EVAc polymers in a controlled fashion with an initial release of 0.20% of the total loaded dose per week and a continued release of 0.70% of the total loaded dose per week after 365 days of implantation in the brain. The intracerebral controlled-release of phenytoin resulted in a statistically significant reduction in seizure activity in the treatment group as evidenced by lower Racine scores. The four groups of rats (n=5 per group) that underwent intracerebral implantation of 10, 20, 30, or 50%-loaded phenytoin-EVAc polymers displayed expected average weight gain and normal behavior over 365 days. One rat in the 50% group, however, died 354 days after polymer implantation for undetermined reasons. CONCLUSIONS: The intracerebral delivery of phenytoin using an EVAc polymer, which will release this drug for a calculated period of 3.5 years, resulted in a significant reduction in seizures in a rat model of cobalt-induced epilepsy by both behavioral and ECoG criteria. In rats, the long-term interstitial delivery of phenytoin in the brain was not associated with any deleterious effects.

Animals↗

Enhanced conjugated polymer fluorescence quenching by dipyridinium-based quenchers in the presence of surfactant.

Poly[(2-methoxy-5-propyloxysulfonate)phenylene vinylene] (MPS-PPV) was synthesized directly from its bischloromethylated monomer, considerably reducing the total number of steps involved in the polymer preparation. For the first time, a simple technique of ultracentrifugation was employed for final purification of the polymer. The interactions among the polymer, surfactant, and quencher molecules, as well as amplified fluorescence quenching and fluorescence enhancement associated with the interactions, were investigated and discussed. When compared with methyl viologen [MV]2+, higher values of Stern-Volmer constant K(SV) values on the order of > or =10(7) M(-1) were observed for the newly synthesized N-(2-carboxyhexadecanoyl)-N'-methyl-4,4'-bipyridinium iodide bromide ([CHMB]2+) quencher in the presence of 1,2-dioleoyl-3- trimethylammonium propane (DOTAP) surfactant. Comparisons of surfactants demonstrated that the K(SV) of [CHMB]2+ was 10-fold higher in the presence of dodecyltrimethylammonium bromide (DTAB) surfactant than with DOTAP. Polymer fluorescence was totally recovered upon addition of DOTAP surfactant to a MV-quenched polymer system, whereas only 50% of fluorescence was recovered upon addition of DOTAP surfactant to the CHMB-quenched polymer solution. In contrast, no fluorescence was recovered when DTAB was added to either the MV- or CHMB-quenched polymer systems. Thus, fluorescence enhancement was observed for the polymer complex with DOTAP, whereas fluorescence quenching was predominant in the polymer complex with DTAB. Such studies will not only help to better understand the intrinsic properties of the ionic conjugated polymer and amplified fluorescence quenching and enhancement but also provide guidelines to develop the next generation of ionic conjugated-polymer-based biosensors.

Fluorescence↗

Molecular engineering of silk-elastinlike polymers for matrix-mediated gene delivery: biosynthesis and characterization.

The unique advantage of genetic engineering techniques for the design and development of polymers for controlled gene delivery lies in exquisite control over polymer structure. In this article we report the biosynthesis and characterization of a series of new silk-elastinlike protein polymers (SELPs), namely, SELP415K, with larger elastin blocks per monomer unit than SELP47K previously studied for matrix-mediated gene delivery. A new cloning strategy was used, where a block of eight elastin units (8E) was integrated into the existing DNA sequence of SELP47K monomer genes using appropriate restriction endonuclease recognition sites. Following random multimerization, multimer gene segments of desired size were selected, expressed, and purified on Ni-agarose columns. The molecular weight and sequence composition of the purified SELPs were determined by MALDI-TOF and amino acid analysis, respectively. The influence of structural changes on the rheological properties of the polymers was investigated. In addition, hydrogel disks were prepared from 47K and 415K-8mer polymer solutions, and the effects of cure time and environmental conditions on the hydrogel equilibrium swelling ratio as a function of polymer composition were studied. DNA sequencing and agarose gel electrophoresis confirmed the successful cloning of the monomer gene segment of SELP415K consisting of 312 bp. Random concatemerization of SELP415K monomer gene segments resulted in a library of SELP415K multimer sequences of 6, 8, and 10 repeats respectively, each yielding a polymer with exact molecular weight and sequence. Rheometric measurements showed that both complex shear modulus (G*) and gelation point were influenced by polymer composition. Equilibrium swelling studies on hydrogel disks prepared from 47K and 415K-8mer polymer solutions showed that changes in polymer composition resulted in different gelation patterns and increased sensitivity toward changes in temperature and ionic strength but not pH. Together these results demonstrate the potential of recombinant techniques in engineering polymers with defined structures which allows the study of the structural parameters affecting matrix-mediated delivery of genes and bioactive agents.

Amino Acid Sequence↗

Prolongation of corneal allograft survival using cyclosporine in a polylactide-co-glycolide polymer.

PURPOSE: To test for prolongation of corneal transplant survival with cyclosporine in a polymer placed in the anterior chamber of corneal allograft recipients. METHODS: Wistar inbred rats with vascularized corneas were recipients of corneal allografts from Sprague-Dawley donor rats. Grafted rats were randomized into six groups: untreated control animals, cyclosporine-polymer anterior chamber recipients, cyclosporine-polymer subconjunctival recipients, cyclosporine-olive oil drop recipients, polymer-only anterior chamber recipients, and autografted Wistar rats. Grafts were examined by slit lamp every 3 days and the clinical condition scored. The cyclosporine concentration in the aqueous humor was assayed at 1, 2, and 4 weeks. At 2 and 4 weeks after transplantation, the eyes were collected for histopathologic evaluation of the grafts. RESULTS: The median survival time of untreated corneal allografts was 8.2 +/- 1.48 days for grafts treated with topical cyclosporine, 8.5 +/- 1.50 days for polymer-only anterior chamber implants, 10.6 +/- 1.90 days for 1% cyclosporine drops, 11.4 +/- 2.50 days for grafts given subconjunctival cyclosporine-polymer, 17 +/- 3.05 days for grafts given cyclosporine-polymer implants in the anterior chamber, and more than 3 months in autografted rats. There was a statistically significant difference ( p < 0.05) between the survival time of the allografts in the animals treated with the cyclosporine-polymer in the anterior chamber compared with the other groups of graft recipients. Significantly higher concentrations of cyclosporine were found in the eyes given an anterior chamber implant of cyclosporine-polymer than in the other treatment groups or the untreated rats. The cyclosporine-polymer implants placed in the anterior chamber induced a transient inflammatory response in transplanted eyes. CONCLUSIONS: Cyclosporine-polymer placed in the anterior chamber significantly prolongs corneal allograft survival in a high-risk corneal graft rejection. This intraocular delivery system may be a valuable adjunct for the suppression of immune graft rejection in high-risk recipients of corneal transplants.

Animals↗

An interfacial tension model of the interaction of water-soluble polymers with phospholipid composite monolayers.

The axi-symmetric drop-shape analysis-pendant drop technique has been used to measure interfacial tension at the chlorobenzene-water interface in the presence of adsorbed films of dimyristoylphosphatidylcholine (DMPC), dipalmitoylphosphatidylcholine (DPPC), DMPC-cholesterol, DPPC-cholesterol, DMPC-cholesterol-dicetyl phosphate (DCP) and DPPC-cholesterol-DCP. A surface-pressure function, pi * = pi lipid-polymer -pi lipid (where pi lipid is the surface pressure of the mono-layer without polymer and pi lipid-polymer is the surface pressure of the lipid mono-layer and adsorbed polymer at equilibrium at the chlorobenzene-water interface) was used to characterize the interaction of eight water-soluble polymers with the lipid films. The equation, delta pi * = pi II*-pi I* (where the subscripts II and I denote the higher and lower lipid composites, respectively) was used to determine the differential effect of cholesterol and DCP on mono-layer characteristics in the presence of 1% w/v polymer. Cholesterol or polymer individually condensed DMPC films and expanded DPPC films. However, composite films of DMPC-cholesterol-DCP and carboxymethylchitin (CM-chitin), poly(acrylic acid) (PAA) or poly(vinyl alcohol) (PVA) were more expanded than DMPC films whereas composite films of DPPC were neither more condensed nor expanded than DPPC films. A polymer impact ratio, P* = pi lipid-polymer/pi lpolymer was calculated and the polymers were ranked in order of their impact on the lipid film. PVA and polysaccharides gave low and high P* values, respectively, corresponding to high and low levels of film interaction, whereas PAA and hydrophobized polysaccharides gave intermediate values, indicating their affinity for and penetration of interfacial films with little disruption of the mono-layer. The results show that measurement of interfacial pressures at the chlorobenzene-water interface might be advantageous for evaluating the action of polymers on biological membranes.

1,2-Dipalmitoylphosphatidylcholine↗

Dose escalation of carmustine in surgically implanted polymers in patients with recurrent malignant glioma: a New Approaches to Brain Tumor Therapy CNS Consortium trial.

PURPOSE: This New Approaches to Brain Tumor Therapy CNS Consortium study sought to determine the maximum-tolerated dose (MTD) of carmustine (BCNU) that can be implanted in biodegradable polymers following resection of recurrent high-grade gliomas and the systemic BCNU exposure with increasing doses of interstitial BCNU. PATIENTS AND METHODS: Forty-four adults underwent tumor debulking and polymer placement. Six patients per dose level were studied using polymers with 6.5%, 10%, 14.5%, 20%, and 28% BCNU by weight. Toxicities were assessed 1 month after implantation by a safety monitoring committee to determine whether subsequent escalations should occur. Nine additional patients were studied at the MTD to confirm safety. BCNU blood levels were obtained before and after polymer implantation. RESULTS: No dose-limiting toxicities were identified at the 6.5%, 10%, or 14.5% dose levels, although difficulties with wound healing, seizures, and brain edema were noted. At the 20% dose, these effects seemed more prominent, and six additional patients were treated at this dose and tolerated treatment well. Three of four patients receiving the 28% polymers developed severe brain edema and seizures, and accrual to this cohort was stopped. Nine additional patients received 20% polymer, confirming this as the MTD. Maximum BCNU plasma concentrations with the 20% loaded polymers were 27 ng/mL. Overall median survival was 251 days. CONCLUSION: The MTD of BCNU delivered in polymer to the surgical cavity is 20%. This polymer provides five times more BCNU than standard commercially available BCNU polymers and results in minimal systemic BCNU exposure. Additional studies are needed to establish the efficacy of high-dose BCNU polymers.

Absorbable Implants↗

Kinetics of protein adsorption and desorption on surfaces with grafted polymers.

The kinetics of protein adsorption are studied using a generalized diffusion approach which shows that the time-determining step in the adsorption is the crossing of the kinetic barrier presented by the polymers and already adsorbed proteins. The potential of mean-force between the adsorbing protein and the polymer-protein surface changes as a function of time due to the deformation of the polymer layers as the proteins adsorb. Furthermore, the range and strength of the repulsive interaction felt by the approaching proteins increases with grafted polymer molecular weight and surface coverage. The effect of molecular weight on the kinetics is very complex and different than its role on the equilibrium adsorption isotherms. The very large kinetic barriers make the timescale for the adsorption process very long and the computational effort increases with time, thus, an approximate kinetic approach is developed. The kinetic theory is based on the knowledge that the time-determining step is crossing the potential-of-mean-force barrier. Kinetic equations for two states (adsorbed and bulk) are written where the kinetic coefficients are the product of the Boltzmann factor for the free energy of adsorption (desorption) multiplied by a preexponential factor determined from a Kramers-like theory. The predictions from the kinetic approach are in excellent quantitative agreement with the full diffusion equation solutions demonstrating that the two most important physical processes are the crossing of the barrier and the changes in the barrier with time due to the deformation of the polymer layer as the proteins adsorb/desorb. The kinetic coefficients can be calculated a priori allowing for systematic calculations over very long timescales. It is found that, in many cases where the equilibrium adsorption shows a finite value, the kinetics of the process is so slow that the experimental system will show no adsorption. This effect is particularly important at high grafted polymer surface coverage. The construction of guidelines for molecular weight/surface coverage necessary for kinetic prevention of protein adsorption in a desired timescale is shown. The time-dependent desorption is also studied by modeling how adsorbed proteins leave the surface when in contact with a pure water solution. It is found that the kinetics of desorption are very slow and depend in a nonmonotonic way in the polymer chain length. When the polymer layer thickness is shorter than the size of the protein, increasing polymer chain length, at fixed surface coverage, makes the desorption process faster. For polymer layers with thickness larger than the protein size, increases in molecular weight results in a longer time for desorption. This is due to the grafted polymers trapping the adsorbed proteins and slowing down the desorption process. These results offer a possible explanation to some experimental data on adsorption. Limitations and extension of the developed approaches for practical applications are discussed.

Adsorption↗

Picloram and napropamide sorption as affected by polymer addition and salt concentration.

Polymer application to soil is a growing practice to improve soil physical properties and reduce soil erosion. Polymer addition can potentially influence herbicide and pesticide sorption in soil. The one-point distribution coefficient Kd values of two herbicides in the absence and presence of each of 10 polymers (7 polyacrylamides and 3 polysaccharides) were determined by the batch equilibrium method. The results showed that nonionic napropamide [2-(alpha-naphthoxy)-N,N-diethyl propionamide] sorption was essentially unaffected by the presence of any of the polymers. The influence of polymers on anionic picloram (4-amino-3,5,6-trichloropicolinic acid) sorption depends on the charge characteristics of polymers and salt concentrations in the solution. Electrostatic interaction and competition for sorption sites are two primary underlying mechanisms for the polymer influence. At low salt concentration, the increased picloram sorption in the presence of both cationic and anionic polymers was attributed to different electrostatic interactions and polymer partitioning between soil and solution phases. At high salt levels, the presence of polymers had either no influence or a slightly negative influence on the picloram sorption, which was attributed to competition for sorption sites. In field conditions, it is more likely that polymers have no or a slightly negative influence on herbicide sorption due to the presence of salts.

Adsorption↗

Biodegradable polymers for controlled delivery of chemotherapy with and without radiation therapy in the monkey brain.

Sustained drug delivery by biodegradable polymer devices can increase the therapeutic efficacy of drugs by producing high local tissue concentrations over extended periods of time. It has been shown previously that implantation of controlled-release polymers impregnated with the nitrosourea carmustine (BCNU) extended the period of survival in rats bearing the 9L glioma compared with similar rats treated with systemically administered BCNU. This study evaluated the effect on the monkey brain of interstitial delivery of BCNU by the biodegradable polyanhydride copolymer poly[bis(p-carboxyphenoxy)propane]anhydride (PCPP) and sebacic acid (SA) in a 20:80 formulation (PCPP:SA). The effect of combining interstitial BCNU with radiation therapy was also evaluated. Eighteen male cynomolgus monkeys were randomly assigned to one of four groups: a control group; a group with implantation of empty polymer; a group with implantation of BCNU-loaded polymer; and a group with implantation of empty polymer in the right hemisphere and BCNU-loaded polymer in the left hemisphere, followed by irradiation. The effects were evaluated radiologically and histologically at specified times. A local reaction by the brain to the polymer was found, which was greater when the polymer contained BCNU. Local cerebral edema was observed radiographically on postoperative Day 14 and had resolved by Day 72. Histologically, a subacute cellular inflammatory response was seen on postoperative Day 16, which had changed to a chronic inflammatory response by Day 72. In the group with radiation therapy administered to the hemisphere bearing BCNU-loaded polymer, only localized pathological changes were detected. In all animals, brain distant from the polymer implantation site was normal. No neurological or general deleterious effects were seen in any of the animals. It is concluded that the interstitial delivery of BCNU by the polyanhydride polymer PCPP:SA is safe in the primate brain and that concomitant radiation therapy did not lead to any adverse effects. These experimental findings are important to an understanding of the clinical effects of PCPP:SA implants in treating brain diseases.

Animals↗