PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tooth Cervix”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

Alveolar bone levels in adults as assessed on panoramic radiographs. (I) Prevalence, extent, and severity of even and angular bone loss.

There is limited information regarding the prevalence and intraoral distribution of infrabony lesions potentially suitable for regenerative procedures in common patients seeking regular dental care in a dental practice. The aim of the present study was to investigate the prevalence and extent of alveolar bone loss and infrabony defects in randomly selected orthopantomograms of adult patients in different age groups seeking treatment at the dental service of the German Armed Forces. A total of 240 panoramic exposures were available for analysis, 60 in each of the age groups <30, 30-39, 40-49, and >or=50 years of age. At each tooth, distances between the cementoenamel junction or margin of restoration and the alveolar crest as well as the bone level were measured with a calliper to the next 0.1 mm. Whereas virtually no bone loss was present in the youngest age group, a major change in bone level frequency distributions occurred after age 30 years. At age 50 years, about 50% of subjects had considerable bone loss of more than 4 mm at 10% or more sites, and 6 mm or more at about 5% sites. Deep infrabony defects were infrequently found before age 40 years. About 20% of patients at least 50 years of age had radiographic evidence of infrabony pockets of 4 mm or more at not more than 5% of sites. Bone loss was more pronounced in the maxilla, especially at molars. In this predominantly male population, periodontal bone loss gradually increased with age. However, prevalence of infrabony defects was very low.

Adult↗

In vivo interfacial adaptation of class II resin composite restorations with and without a flowable resin composite liner.

The aim of this study was to evaluate in vivo the interfacial adaptation of class II resin composite restorations with and without a flowable liner. In 24 premolars scheduled to be extracted after 1 month, 48 box-shaped, enamel-bordered class II cavities were prepared and restored with a flowable liner (FRC, Tetric Flow/Tetric Ceram/Syntac Single-Component) or without (TRC), cured with three different curing modes: soft start and 500- or 700-mW/cm2 continuous irradiation. Interfacial adaptation was evaluated by quantitative scanning electron microscopic analysis using replica method. Gap-free adaptation in the cervical enamel (CE) was observed for FRC and TRC in 96.2 and 90.2%, for the dentin (D) in 63.6 and 64.9%, and for occlusal enamel (OE) in 99.7 and 99.5%, respectively. The difference between the two restorations was not statistically significant (ns). Significant better adaptation was observed for OE than CE and D (p<0.01), and for CE than D (p<0.01). Gap-free adaptation with the soft-start and 500- and 700-mW/cm2 continuous-curing modes was observed for CE: 88.7%, 92.7%, 97.9% (ns); OE: 99.8%, 98.7%, 100% (ns); and D: 64.0%, 63.9%, and 64.6% (ns), respectively. It can be concluded that neither the use of flowable resin composite liner nor the curing mode used influenced the interfacial adaptation.

Adolescent↗

Three-dimensional finite element analysis of the retention of fixed partial dentures.

Four three-dimensional mathematical models were generated, each representing a three-unit fixed partial denture. The second premolar and second molar were used as abutments. Different associations of dental support preparation were tested. A 500-N axial load was applied to the pontic. Strains were analysed for each dental support by means of a three-dimensional finite element analysis technique. The results showed that the greatest strains were observed on the weaker abutment, the premolar. The cervical margin facing the edentulous area is affected most, regardless of the model or the dental support. The greater the dento-prosthetic differential surface between the two dental supports (thus the greater the retention differential) the higher the risk of unsealing.

Bicuspid↗

Relations in color among maxillary incisors and canines.

OBJECTIVES: To establish the strength of color relation among the maxillary central incisor, lateral incisor and canine teeth by using digital photography. This relation might be useful for the color reconstruction of the missing part of a tooth from the color obtained from neighboring teeth. METHODS: The L*a*b* values of the maxillary incisors and canines were determined in 100 subjects. Paired t-tests, Pearson correlations and linear regression analyses were used to describe the relation of the L*a*b* values between the three teeth for each segment (cervical, middle and incisal). RESULTS: The mean L*a*b* values of the canines differed statistically significantly from the values of the central incisors (p<0.001) except for L* and a* values in the cervical segment between the lateral incisor and canine. The color differences between the incisors were statistically significant in fewer cases. The relation in color was the highest between the cervical segments of the three teeth, with respect to L* (r = 0.45-0.65; p < 0.001), b* (r = 0.49-0.55; p < 0.001), and a* (r = 0.38-0.61; p < 0.001), and no relation was found between the incisal segments of central incisor and canine. SIGNIFICANCE: There is a relation in color between the maxillary incisors and canines, which is stronger between the cervical than between the middle and incisal segments. Therefore, the color prediction is most reliable when the cervical parts of the teeth are used.

Adult↗

A randomized controlled study evaluating the effectiveness of a two-step self-etch adhesive with and without selective phosphoric-acid etching of enamel.

OBJECTIVES: The purpose of this randomized controlled clinical trial was to test the hypothesis that a two-step self-etch approach is equally effective to restore cervical class-V lesions as a self-etch approach with beforehand selective etching of enamel using phosphoric acid. METHODS: Twenty-nine patients received two or four restorations randomly following two experimental protocols ('paired-tooth' study design): (1) A 'mild' self-etch adhesive (Clearfil SE, Kuraray) was applied following a self-etch approach on both enamel and dentin (C-SE non-etch); (2) Similar application of Clearfil SE, but including beforehand selective acid-etching of the enamel cavity margins with 40% phosphoric acid (C-SE etch). Clearfil AP-X (Kuraray) was used as restorative composite for all 100 restorations. The clinical effectiveness was recorded in terms of retention, marginal integrity and clinical micro-leakage after 2 years of clinical service. RESULTS: No restoration losses were recorded. Clinical micro-leakage was slight and only rarely observed. No significant differences were found between both groups for the diverse parameters evaluated except for the number of small incisal marginal defects, which was significantly higher in the C-SE non-etch group (McNemar: p = 0.0391). SIGNIFICANCE: The clinical effectiveness of the mild two-step self-etch adhesive Clearfil SE was excellent after 2 years of clinical service. Although in general no difference in clinical performance was recorded when Clearfil SE was applied following either of the experimental protocols, more marginal defects at the enamel side were noticed when enamel was not beforehand etched with phosphoric acid. However, these defects were small and of clinically negligible relevance.

Acid Etching, Dental↗

Effect of fracture strength of primer-adhesive mixture on bonding effectiveness.

OBJECTIVE: The purpose of this study was to measure the micro-tensile bond strength (microTBS) of two adhesives to dentin and to correlate this microTBS with the micro-tensile fracture strength (microTFS) of primer-adhesive mixtures of the two adhesives. METHODS: The three-step etch&rinse adhesive OptiBond FL (Kerr) and the two-step self-etch adhesive Clearfil SE Bond (Kuraray) were used to bond Filtek Z100 (3M ESPE) to twenty mid-coronal dentin surfaces. The microTBS was determined at 1 and 24 h after light-curing. In addition, the microTFS of primer-adhesive mixtures (primer:adhesive=1:3 by weight) and of the pure adhesives (controls) were measured after the same time intervals. RESULTS: The microTBS to dentin of OptiBond FL at 24 h was significantly higher than at 1 h and than the microTBS of Clearfil SE Bond at 24 h. The mean microTFS of the primer-adhesive mixtures was always lower than the microTFS of the respective adhesives. The highest reduction in microTFS due to mixing primer with the adhesive resin was measured for Clearfil SE Bond. Both the microTFS of the primer-adhesive mixtures and the pure adhesives of OptiBond FL and Clearfil SE Bond increased with time. SIGNIFICANCE: The early 1 h microTBS to dentin was lower than the 24 h microTBS for OptiBond FL, but not for Clearfil SE Bond. Differences in polymerization efficiency as well as in the resulting interfacial strength may explain such varying early bond strengths to dentin.

Composite Resins↗

Immediate versus water-storage performance of Class V flowable composite restoratives.

OBJECTIVES: The aims of this investigation were to clarify the effects of 24h water-storage and finishing time on mechanical properties and marginal adaptation to a Class V cavity of eight modern flowable resin-composites. METHODS: Eight flowable composites, plus two controls (one microfilled and one hybrid composite), were investigated with specimen sub-groups (n = 10) for each property measured. The principal series of experiments was conducted in model Class V cavities with interfacial polishing either immediately (3 min) after setting or after 24 h water-storage. After the finishing procedure, each tooth was sectioned in a buccolingual direction through the center of the restoration, and the presence or absence of marginal-gaps was measured (and then summed for each cavity) at 14 points (each 0.5 mm apart) along the cavity restoration interface (n = 10 per group; total points measured = 140). The shear bond-strengths to enamel and to dentin, and flexural strengths and moduli data were also measured at 3 min and after 24 h water-storage. RESULTS: For all flowable composites, polished immediately after setting, 14-30 summed gaps were observed (controls: 64 and 42). For specimens polished after 24 h, a significantly (p < 0.05) reduced number of 8-17 summed gaps occurred for only 3 flowable composites; whereas for 5 flowable composites there were non-significantly-different (p > 0.05) numbers (11-17) of summed gaps (controls: 28 and 22). After 24h storage, shear bond-strengths to enamel and to dentin, flexural strengths and moduli increased highly significantly (p < 0.001) for all materials, except Silux Plus. SIGNIFICANCE: A post-cure interval of 24 h resulted in enhanced mechanical and adhesive properties of flowable dental composites. In a minority of cases there was also a reduced incidence of marginal-gap formation. However the latter effect may be partly attributed to 24 h delayed polishing, even though such a delay is not usual clinical practice.

Bicuspid↗

Resin bonding to cervical sclerotic dentin: a review.

Several reports have indicated that resin bond strengths to noncarious sclerotic cervical dentine are lower than bonds made to normal dentine. This is thought to be due to tubule occlusion by mineral salts, preventing resin tag formation. The purpose of this review was to critically examine what is known about the structure of this type of dentine. Recent transmission electron microscopy revealed that in addition to occlusion of the tubules by mineral crystals, many parts of wedge-shaped cervical lesions contain a hypermineralised surface that resists the etching action of both self-etching primers and phosphoric acid. This layer prevents hybridisation of the underlying sclerotic dentine. In addition, bacteria are often detected on top of the hypermineralised layer. Sometimes the bacteria were embedded in a partially mineralised matrix. Acidic conditioners and resins penetrate variable distances into these multilayered structures. Examination of both sides of the failed bonds revealed a wide variation in fracture patterns that involved all of these structures. Microtensile bond strengths to the occlusal, gingival and deepest portions of these wedge-shaped lesions were significantly lower than similar areas artificially prepared in normal teeth. When resin bonds to sclerotic dentine are extended to include peripheral sound dentine, their bond strengths are probably high enough to permit retention of class V restorations by adhesion, without additional retention.

Acid Etching, Dental↗

The effect of light-curing modes on the microleakage of cervical resin composite restorations.

OBJECTIVE: This study investigated the effect of light-curing modes on the microleakage of cervical resin composite restorations. METHODS: Eighty wedge-shaped cervical cavities, C-factor approximately 1.3, were prepared on the labial surface of bovine incisors. The cavities were treated with a two-step experimental self-etching primer adhesive system containing an antibacterial monomer (ABF), according to the manufacturer's instructions, and filled with a single increment of a hybrid resin composite. The restorations were allocated randomly into four groups of 20: Group 1-the restorations were light-cured for 40 s with a conventional light-curing unit (New Light VL-II); Group 2-the restorations were cured with Candelux using a two-step mode; Group 3-the restorations were cured with Astralis 7 using a ramping mode; Group 4-the restorations were light-cured for 3 s with a plasma arc light-curing unit (Wave Light). Half of the specimens from each group were subjected to thermocycling (5-60 degrees C, 15 s dwell time, 5000 cycles) prior to immersion in 0.5% basic fuchsin. The teeth were sectioned and the degrees of dye penetration were scored. The data were analyzed with either the Kruskal-Wallis test or the Mann-Whitney U-test (p < 0.05) RESULTS: No significant differences were found in the microleakage scores among the light-curing modes used. The restorations tended to display more microleakage when they were subjected to thermocycling, but the differences were not statistically significant. CONCLUSIONS: These findings suggest that light-curing modes may have no effect on the microleakage of cervical cavities with a small C-factor, as is the case in this study.

Animals↗

Three-dimensional evaluation of gap formation of cervical restorations.

OBJECTIVES: In some studies gap formation has been evaluated in just one section of the restorative. This in vitro study aimed to design a quantitative three-dimensional method for evaluation of the contraction gap in restoratives. METHODS: Cervical cavities were prepared on buccal, palatal or lingual surfaces in human extracted molars and were then filled with resin composites. Specimens were reduced every 100 microm in a direction parallel to the tooth axis, and perpendicular to the cavity floor from one proximal side to the other. The sequence of reducing the sections by 100 microm, image taking (250x) and observation of these images (maximal 2500x) were repeated. Three-dimensional images of the contraction gap were made using analytical software and the proportions of the interface with gap formation calculated. RESULTS: The mean proportions of the interface with gap formation of the self-etching system (Clearfil Liner Bond II Sigma) was 41.7+/-6.3% and that of the self-priming system (Single Bond) was 38.2+/-3.9%; there was no significant difference. CONCLUSIONS: Approximate three-dimensional images of the in vitro contraction gap could be drawn and the mean proportions of the interface with gap formation could be more precisely calculated than by previous methods.

Bisphenol A-Glycidyl Methacrylate↗

Class II composite resin restorations with two polymerization techniques: relationship between microtensile bond strength and marginal leakage.

OBJECTIVE: To determine the relationship between leakage and microtensile bond strength in the same specimen of direct Class II composite restorations performed with two polymerization techniques. METHODS: Class II slot preparations were made in 40 non-carious human third molars and restored using Single Bond and P-60 (3M ESPE) according to the manufacturer's indications. Half of the preparations had the cervical margin in enamel and half in dentin. Teeth were incrementally restored either with direct polymerization from occlusal surface or with indirect polymerization through translucent matrices and reflective wedges. Teeth were isolated with nail varnish and immersed in fucsin for 24h. Subsequently, they were sectioned into slabs that were measured for leakage (mm), and trimmed to obtain hour-glass shaped specimens for microtensile bond test. Fractured specimens were examined under magnification (40 x) to evaluate the fracture mode. Data were analyzed with Mann-Whitney and Kruskal-Wallis (microleakage), two-way ANOVA and Student-Newman-Keuls tests (bond strength). The relationship between microleakage and microtensile bond strength were analyzed with Spearman's correlation test. RESULTS: There were no significant effects of polymerization technique and margin location on both leakage and bond strength (p>0.05). Bond strengths were higher in preparations with enamel margins than in preparations with dentin margins, when restored with indirect polymerization technique (p<0.05). No significant correlation was found between leakage and bond strength (p>0.05). CONCLUSIONS: Polymerization techniques had no influence on microleakage and bond strength of Class II composite restorations, and there was no relationship between these variables when evaluated in the same specimen.

Analysis of Variance↗

Digital moiré interferometric investigations on the deformation gradients of enamel and dentine: an insight into non-carious cervical lesions.

OBJECTIVES: The objective of this study was to evaluate the biomechanical basis of non-carious cervical lesions by examining the patterns of deformation (strain) in the enamel and dentine. METHODS: The digital moiré interferometry is optics based non-destructive, whole-field experimental technique that provides whole-field strain information. Diffraction gratings (with a frequency of 1200 lines/mm) were transferred onto sagittal sections of human teeth, which were subsequently loaded compressively for loads ranging from 10 to 200 N at the incisal edge of the tooth. The acquired digital moiré fringe patterns were used to determine the in-plane deformation pattern in the enamel and the dentine in the direction parallel to the long axis (axial direction) and in the direction perpendicular to the long axis (lateral direction) of the tooth. RESULTS: It is observed that the enamel displayed marked strain gradients in the lateral direction, while the coronal dentine experienced marked strain gradients in the axial directions during compression. With the increase in applied loads, the strains in the enamel increased at the cervical edge (above the cemento-enamel junction) on the facial side, while the strains in the dentine increased below the cemento-enamel junction on the facial side. CONCLUSION: The enamel and dentine displayed unique in-plane deformation patterns in the axial and the lateral directions of the tooth. These experiments support the hypothesis that occlusal loading will contribute to cervical loss of dental hard tissues.

Compressive Strength↗

Comparison of interfacial characteristics of adhesive bonding to superficial versus deep dentine using SEM and staining techniques.

OBJECTIVES: A primary reason for premature failure of Class II composite restorations is recurrent decay at the gingival margin. The integrity of the gingival margin depends on the bond formed with dentine. Using scanning electron microscopy (SEM) and histomorphologic technique, the purpose of this study was to characterise the adhesive/dentine (a/d) bond in dentine sections from the dentinoenamel junction (DEJ) and the cementoenamel junction (CEJ) with commercial adhesives of varying hydrophobic/hydrophilic composition. MATERIALS AND METHODS: The occlusal 1/3 of the crown was removed from 20 human third molars, this exposed the surface used for the DEJ sections. The teeth were sectioned occluso-gingivally into equal halves: one-half representing the DEJ; the remaining half was sectioned 4mm deep to the exposed surface (CEJ). Each half was treated with the same adhesive. The teeth were randomly selected for treatment with Single Bond (SB, 3M) or Dentastic UNO (UNO, Pulpdent) using wet bonding technique as per manufacturers' instructions. Thin (3-5mum) sections of native a/d interfaces were cut and stained with Goldner's trichrome for light microscopic (LM) examination. Companion slabs were polished and acid-bleach treated, then analysed with SEM. RESULTS: DEJ sections: SB/dentine specimens had approximately 4mum exposed protein at the interface, UNO infiltrated the depth of the demineralised dentine and encapsulated exposed protein. CEJ sections: SB/dentine specimens had highly variable interface structure with localized exposed protein, UNO/dentine exhibited 3-5mum exposed protein at the interface. The quality of the interface was exaggerated and the above differences were not revealed based on SEM characterisation. CONCLUSIONS: As a result of adhesive phase separation, SB does not form structurally integrated a/d bonds at the DEJ or CEJ. The increased hydrophilic composition of UNO contributes to the formation of an integrated a/d bond at the DEJ, but structural differences and increased moisture leads to unprotected protein at the a/d interface in the CEJ sections. The inability of the SEM technique to reveal the complexity of the interface could be related to the modifications of the a/d interface caused by polishing and acid-bleach treatment.

Adhesives↗

Five-year clinical evaluation of two adhesive systems in non-carious cervical lesions.

OBJECTIVE: This controlled clinical trial evaluated the 5-year clinical performance of a self-etching primer system including selective enamel-etching with phosphoric acid and a one-bottle adhesive system. METHODS: Seventy-two non-carious cervical lesions in 8 patients (4 male and 4 female) with a mean age of 61.3 years (range 45-78) participated in the study. An enamel bevel was placed and dentin lightly ground, and cavities restored with clearfil liner bond II (LB) or single bond (SB) in conjunction with a hybrid resin composite (Clearfil AP-X). In the case of 27 cavities for LB, the enamel was pretreated with 37% phosphoric acid for 10 s. Each patient received both types of restoration, which were distributed on a random basis. All restorations (37 restorations for LB and 35 restorations for SB) were placed by one dentist. The restorations were evaluated blind after 5 years using modified USPHS criteria. The data were statistically analyzed using the Fisher's exact test. RESULTS: All but one restoration (which was replaced by a crown after the 2-year recall) were evaluated after 5 years. 100% retention rates were recorded for both restorative groups. No caries was detected in association with any restorations. The only minor problem was marginal discoloration; superficial and localized marginal discoloration occurred around 18% of the restorations, and mainly at the dentin margin. There were no significant differences in the marginal integrity between the LB and SB groups. CONCLUSIONS: Restorative materials used in this study demonstrated a good clinical effectiveness in the restoration of non-carious cervical lesions for 5 years.

Aged↗

Tooth morphology and characteristics of non-carious cervical lesions.

OBJECTIVES: Two 3-dimensional models, one of a lower second premolar and one of a lower central incisor were used to investigate effects of load on the location and magnitude of cervical strains. METHODS: Point loads of 100 N were applied to the model premolar (at the cusp tip, parallel and 45 degrees to the long axis of the tooth) and incisor (at the mid-buccal point on incisal edge, parallel and 45 degrees to the long axis of the tooth). Outputs were presented in the form of tensile-strain contours and vector plots. RESULTS: Strains were concentrated near the cementoenamel junction (CEJ) regardless of load direction, and oblique loading showed higher tensile strains, opposite to the point of loading, than vertical loading for both models. For the premolar model, regardless of loading direction, strains were concentrated at the mid- buccal CEJ. In contrast, under vertical loading on the incisor model, tensile strains were concentrated at the line-angle of CEJ. From oblique loads, vector plots of both models showed tensile vectors in vertical directions while vertical loads showed tensile vectors in horizontal directions. CONCLUSION: Mechanisms of non-carious cervical lesions (NCCLs) may in part be due the changing orientation of tensile strains as well as their magnitude. Stress concentration at the CEJ related well to the common location of clinical NCCLs. The crown-root morphology may have an influence on the initial location of non-carious cervical lesions.

Bicuspid↗

Fiber-reinforced packable resin composites in Class II cavities.

OBJECTIVE: To evaluate the 6-year performance of two glass fiber-reinforced packable resin composites in Class II cavities. METHODS: Sixty-three participants received 87 medium to large, cervically dentin bordered, Class II restorations of two fiber-reinforced resin composites, 42 Nulite F (N) and 45 Alert (A). The restorations were evaluated clinically, according to slightly modified USPHS criteria at baseline, after 6 months, and yearly during 6 years. RESULTS: At 2 years the cumulative failure frequencies for N and A were 4.8% and 2.2%, respectively, which increased at 6 years to 25.0% and 12.8%. Reasons for failure were secondary caries, material and cusp fracture. The majority of the failures occurred after 3 years. Secondary caries occurred between 4 and 6 years. The incorporation of fibers resulted in very rough surface characteristics. CONCLUSIONS: A rather high failure rate was observed for one of the fiber-reinforced resin composites, while the other fulfilled the ADA criteria. The occurrence of most failures after 3 years indicated the necessity of long-term evaluations of new materials.

Adult↗

Mechanical evaluation of cervical glass-ionomer restorations: 3D finite element study.

OBJECTIVES: The aim of this paper was to investigate the influence of lesion shape and depth as well as the direction of occlusal loading on the mechanical response of cervical GIC restorations. METHODS: A finite element model of a lower first premolar was created. Both wedged and rounded lesions were then modelled with incremental depth after which the tooth was loaded at different angles. First principal stress (tension) was employed as an indicator of material failure, by contrasting our calculated stresses with the ultimate tensile strength of the GIC and known values of bond strength between material and tooth substrate. RESULTS: Obliquely loaded teeth exhibited significantly higher tensile stress in the cervical region of the restoration. For forces inclined at angles of 30 degrees and higher to the vertical tooth axis, the tensile stresses in the cervical margin of the restoration exceeded the ultimate material and bond strength. In contrast, lesion shape and depth have only a minor influence on tensile stress development. CONCLUSIONS: Lesion depth and shape are not of primary concern from a mechanical perspective for a restorative treatment decision. By contrast, occlusal diagnosis and subsequent re-adjustments of tooth contacts do form a critical part of the treatment of non-carious cervical lesions (NCCLs).

Dental Materials↗

Effects of various irrigation solutions on microleakage of Class V composite restorations.

STATEMENT OF THE PROBLEM: Irrigation solutions used in the preparation of composite restorations have been reported to contain potential contaminants that may interfere with, and compromise, composite bonding. PURPOSE: The purpose of this in vitro study was to evaluate microleakage of Class V composite restorations after irrigation of acid conditioner with various solutions. MATERIAL AND MENTODS: Standardized Class V preparations (5 mm wide, 4 mm high and 2 mm deep) were made at the cemento-enamel junction on available buccal, lingual, mesial, and distal surfaces of extracted human posterior teeth. The prepared teeth, separated into 7 groups (n=10), were etched for 10 seconds with a 37% phosphoric acid gel. Each group was irrigated with 1 of the following solutions: (1) tap water, (2) sterile water, (3) sodium chloride solution, (4) filtered water, (5) chlorhexidine, (6) sodium hypochlorite, and (7) distilled water. Each preparation was treated with a bonding agent (Opti-Bond Solo) and then restored with a hybrid composite (Herculite XRV). The restorations were polished with Soflex polishing disks and then thermal cycled for 1000 cycles between 5 degrees C and 55 degrees C with a 20-second dwell time. Assessment of microleakage was performed by application of a dye penetrant, sectioning of the teeth, and examination at original magnification x 20. The nonparametric Kruskal-Wallis test (alpha=.05) was used for statistical analysis. RESULTS: Microleakage ranging from 10% to 30% was observed in all groups tested. Tap water exhibited the highest incidence of leakage, sterile water the least, with the other irrigation solutions leading to intermediate leakage. However, there was no significant difference in microleakage resulting from any of the irrigation solutions tested. CONCLUSION: The effect of irrigation solutions used in this in vitro study was not significant.

Acid Etching, Dental↗