PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21Linked to original sources

New surface modification for Ti-6Al-7Nb alloy: oxygen diffusion hardening (ODH).

PVD-TiN coating and N+ implantation of Ti-6Al-7Nb alloy resulted in surface hardening to a depth of less 3 microns. The new oxygen diffusion hardening (ODH) treatment increased the hardness gradually to 50 microns. PUD-TiN showed an improvement in the tribological properties, while N+ implantation increased the PE wear rate. The wear rate of the ultrahigh-molecular-weight as well as the friction coefficient were reduced to one-half of the values achieved with the combination of CoCrMo-alloy when paired against the ODH-treated surface. In pairing with ZrO2-containing bone cement the ODH-treated surface showed only a minimal reaction.

Corrosion↗

Surface modification of retinal pigment epithelial cells: effects on phagocytosis and glycoprotein composition.

Proteases have been used as a tool to investigate the role of cell-surface molecules of cultured retinal pigment epithelial cells (RPE) in the phagocytosis of rod outer segments (ROS). Proteolytic digestion of RPE cells by pronase, thermolysin and Staphylococcus aureus V8 protease (V8 protease) inhibited the phagocytosis of ROS without affecting the viability of the RPE cells. A particular feature of RPE cell proteolysis was that those macromolecules responsible for ROS ingestion were susceptible, while those macromolecules that mediated ROS binding were resistant to cleavage by all three proteases. By taking advantage of this phenomenon, ROS were used as affinity particles to obtain a plasma membrane-enriched fraction of RPE cells before and after proteolytic digestion. All three proteases partially or completely removed several glycoproteins from the cell surfaces. Removal of these glycoproteins was correlated with a loss in phagocytic ability by RPE cells. Two high-molecular-weight (MW) glycoproteins of MWs 160,000 and 214,000 were consistently removed by all proteases tested. Protease-treated RPE cells restored their phagocytic capabilities and normal glycoprotein composition within 24 hr after proteolytic treatment. These data suggest that glycoproteins located on the surfaces of RPE cells may be involved in mediating the phagocytosis of ROS by these cells.

Animals↗

Surface modification of natural rubber latex films via grafting of poly(ethylene glycol) for reduction in protein adsorption and platelet adhesion.

Natural rubber (NR) latex films with surface grafted poly(ethylene glycol) (PEG) chains were prepared by UV-induced graft copolymerization of methoxy poly(ethylene glycol) monomethacrylate (PEGMA) onto the plasma-pretreated NR latex films. PEGMA macromononers of different molecular weights were used. The UV-induced graft copolymerization of PEGMA onto the plasma-pretreated NR latex films was also explored with PEGMA of different macromonomer concentrations and with different UV graft copolymerization time. The surface microstructures and compositions of the PEG-modified NR latex films were characterized by contact angle, X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM) measurements. In general, higher macromonomer concentration and longer UV graft copolymerization time led to a higher graft yield. Water contact angle measurements revealed that the hydrophilicity of the NR latex film surface was greatly enhanced by the grafting of the PEG chains. The NR surface with a high density of grafted PEG was very effective in reducing protein adsorption and platelet adhesion. A lower graft concentration of the high-molecular-weight PEG was more effective than a high graft concentration of the low-molecular-weight PEG in reducing protein adsorption and platelet adhesion.

Journal Article↗

Effect of surface modification of an engineered activated carbon on the sorption of 2,4-dichlorophenoxy acetic acid and benazolin from water.

The performance of a conventional (F400) and a surface modified activated carbon (F400AN) has been investigated for the sorption of benazolin and 2,4-dichlorophenoxy acetic acid (2,4-D) from water. It was observed that the modified carbon, F400AN, which was obtained by annealing the conventional sample had a higher BET surface area (960 m2 g(-1) compared to 790 m2 g(-1)) and it had a higher proportion of micropores. This was attributed to the loss of oxygen containing functional groups during the thermal treatment. Zeta potential and pH titration measurements also showed that acidic functionality had been lost on the F400AN sample. The adsorption data were analysed and were fitted well using the Langmuir isotherm. The modified carbon marginally out-performed the conventional activated carbon for sorption of these two herbicides. Thermodynamic parameters (DeltaG0, DeltaH0, and DeltaS0) were determined and their values indicated that the sorption process was spontaneous and endothermic for both herbicides. A pseudo-second-order kinetic model was employed for analysing the kinetic data. It was concluded that the herbicide sorption process was controlled by a film diffusion mechanism.

2,4-Dichlorophenoxyacetic Acid↗

Sensitivity enhancement of DNA sensors by nanogold surface modification.

A novel amplified microgravimetric gene sensing system was developed using quartz crystal microbalance modified by gold nanoparticles anchored on its 1,6-hexanedithiol modified gold electrode surface, and ultrasensitive detection of DNA hybridization was accomplished at the level of at least 2 x 10(-16) M.

Biosensing Techniques↗

Surface modification for controlled studies of cell-ligand interactions.

This work describes a method for coupling cell adhesion peptides to hydrophobic materials for the purpose of controlling surface peptide density while simultaneously preventing nonspecific protein adsorption. PEO/PPO/PEO triblock copolymers (Pluronic F108) were equipped with terminal pyridyl disulfide functionalities and used to tether RGD containing peptides to polystyrene (PS). The density of F108 on PS was 1.4 E5 +/- 2.12 E1 molecules/microm2. XPS and ToF SIMS indicated that the F108 coating was homogeneous and that the unmodified and activated F108 distributed evenly on PS. By mixing unmodified F108 with PDS-activated F108 prior to adsorption, it was possible to vary peptide density between 0 and 8.7 E4 +/- 2.66 E3 peptides/microm2, while otherwise, maintaining consistent surface properties. GRGDSY grafted PS supported cell attachment, spreading, and development of cytoskeletal structure, all of which were found to increase with increasing peptide density. Cell proliferation followed this same trend, however, maximal growth occurred at a submaximal peptide density. Cell aspect ratio varied in a biphasic manner with GRGDSY density. F108 coated PS and GRGESY grafted PS were inert to cell adhesion. Cells released from GRGDSY grafted PS upon addition of either a reducing agent or free GRGDSY, which indicates that cell-substrate interactions were mediated solely by the tethered peptides.

3T3 Cells↗

Electroanalysis using macro-, micro-, and nanochemical architectures on electrode surfaces. Bulk surface modification of glassy carbon microspheres with gold nanoparticles and their electrical wiring using carbon nanotubes.

Gold nanoparticles (approximately 30-60 nm in diameter) were deposited onto the surface of glassy carbon microspheres (10-20 microm) through electroless plating to produce bulk (i.e., gram) quantities of nanoparticle surface-modified microspheres. The gold nanoparticle-modified powder was then characterized by means of scanning electron microscopy and cyclic voltammetry. The voltammetric response of a macroelectrode consisting of a film of gold nanoparticle-modified glassy carbon microspheres, bound together and "wired-up" using multiwalled carbon nanotubes (MWCNTs), was investigated. We demonstrate that by intelligently exploiting both nano- and microchemical architectures and wiring up the electroactive centers using MWCNTs in this way, we can obtain macroelectrode voltammetric behavior while only using approximately 1% by mass of the expensive gold material that would be required to construct the equivalent gold film macrodisk electrode. The potential utility of electrodes constructed using chemical architectures such as this was demonstrated by applying them to the analytical determination of arsenic(III) concentration. An optimized limit of detection of 2.5 ppb was obtained.

Electrochemistry↗

Superparamagnetism of magnetite nanoparticles: dependence on surface modification.

Superparamagnetic iron oxide nanoparticles (SPION) with an average particle diameter of 6 nm are prepared by controlled chemical coprecipitations. Colloidal suspensions of noninteracting SPION, where the surface has been modified with three different types of biocompatible substances, namely, starch, gold (Au), and methoxypoly(ethylene glycol) (MPEG) have been fabricated via three different techniques. Starch-coated SPION are prepared by coprecipitation in a polymeric matrix, Au-coated SPION are fabricated by the microemulsion method, and MPEG-coated SPION are prepared using the self-assembly approach. The magnetic nanoparticles form a core-shell structure, and the magnetic dipole-dipole interactions are screened by a layer of coating agents. The amounts of coating agents and SPION are indirectly calculated from the thermogravimetric analysis and superconducting quantum interference device measurements by assuming passive oxidation on the surface of the SPION, and the other conditions do not influence the measurements. The dependency of the spectral characteristics of Mössbauer spectroscopy as a function of an external magnetic field Hext is measured to investigate the effect of dipole-dipole screening of the different coating layers on the SPION. Uncoated SPION show a stable magnetic moment under Hext, and the superparamagnetic (SPM) fraction transforms to a ferrimagnetic state. Starch and Au-coated SPION retain the SPM fraction according to Mössbauer spectroscopy and magnetization measurements. MPEG-coated SPION show hyperfine magnetic structure without the quadrupole effect with increasing the value of the blocking temperature.

Journal Article↗

Surface modification of silicone for percutaneous implantation.

In order to prevent epidermal down growth when a silicone percutaneous device was implanted, immobilization of collagen was performed onto the surface of a silicone device. The immobilization of collagen was achieved through covalent bonds between the amino groups in the collagen molecules and the carboxyl groups in poly (acrylic acid) chains grafted onto the silicone device surface. When the collagen-immobilized silicone device model was percutaneously implanted in rabbits, no sign of epidermal down growth was observed even 7 weeks after implantation, while the epidermis reached down to the deep part of the dermis as early as 3 weeks after implantation when collagen was not immobilized onto the device model surface. To have tighter fixation of the device models to the surrounding dermal tissue, the silicone device model was covered with a polyethylene sponge having an average interconnecting pore size of 150 microns. Collagen immobilization was also performed onto the sponge surface. Both the collagen-immobilized silicone device models as well as the non-treated models with polyethylene sponge were percutaneously implanted in rabbits and epidermal down growth as well as the occurrence of bacterial infection was examined. Without collagen immobilization onto the sponge surface of the device model, bacterial infection was noticed as early as 2 weeks after the implantation. The number of infected device models increased as the implantation time became longer and bacterial infection was observed in six out of seven device models at the 10th week post implantation. When the sponge surface was immobilized with collagen, bacterial infection was noticed in only one model at the 5th week after implantation. Six out of seven implanted device models with collagen immobilization were free of bacterial infection until the animals were sacrificed 30 weeks after implantation.

Animals↗

Surface modification with PEO-containing triblock copolymer for improved biocompatibility: in vitro and ex vivo studies.

Poly(ethylene oxide) (PEO) has been frequently used to modify biomaterial surfaces for improved biocompatibility. We have used PEO-polybutadiene-PEO triblock copolymer to graft PEO to biomaterials by gamma-irradiation for a total radiation dose of 1 Mrad. The molecular weight of PEO in the block copolymer was 5000. In vitro study showed that fibrinogen adsorption to Silastic, polyethylene, and glass was reduced by 70 to approximately 95% by PEO grafting. On the other hand, the reduction of fibrinogen adsorption was only 30% on expanded polytetrafluoroethylene (e-PTFE). In vitro platelet adhesion study showed that almost no platelets could adhere to PEO-coated Silastic, polyethylene, and glass, while numerous platelet aggregates were found on the ePTFE. The platelet adhesion in vitro corresponded to the fibrinogen adsorption. When the PEO-grafted surfaces were tested ex vivo using a series shunt in a canine model, the effect of the grafted PEO was not noticeable. Platelet deposition on ePTFE was reduced by PEO grafting from 8170 +/- 1030 to 5100 +/- 460 platelets 10(-3) microm2, but numerous thrombi were still present on the PEO-grafted surface. The numbers of platelets cumulated on Silastic, polyethylene, and glass were 100 +/- 80, 169 +/- 35, and 24 +/- 22 platelets 10(-3) microm2, respectively. This is about 35% reduction in platelet deposition by PEO grafting. While the numbers of deposited platelets were small, the decreases were not as large as those expected from the in vitro study. This may be due to a number of reasons which have to be clarified in future studies, but it appears that in vitro platelet adhesion and fibrinogen adsorption studies may not be a valuable predictor for the in vivo or ex vivo behavior of the PEO-grafted surfaces.

Adsorption↗

Simple surface modification of poly(epsilon-caprolactone) for apatite deposition from simulated body fluid.

Poly(epsilon-caprolactone) (PCL) with a bone-like apatite layer bound to its surface could be useful as a scaffold for tissue engineering applications. In the present study, the surface of PCL was treated with aqueous NaOH to introduce carboxylate groups onto the surface. The NaOH-treated material was subsequently dipped in aqueous CaCl(2) and K(2)HPO(4).3H(2)O alternately three times to deposit apatite nuclei on the surface. The surface-modified material successfully formed a dense and uniform bone-like surface apatite layer after incubation for 24 h in simulated body fluid with ion concentrations approximately equal to those of human blood plasma.

Absorbable Implants↗

Vascular PET prostheses surface modification with cyclodextrin coating: development of a new drug delivery system.

PURPOSE: Cyclodextrins (CDs) are torus shaped cyclic oligosaccharides with a hydrophobic internal cavity and a hydrophilic external surface. We performed and analysed an antibiotic binding on Dacron (polyethyleneterephtalate, PET) vascular grafts, previously coated with CDs based polymers. METHODS: The CDs coating process was based on the pad-dry-cure method patented in our laboratory. The Dacron prostheses were immersed into a solution containing a polycarboxylic acid, a cyclodextrin and a catalyst, and placed into a thermofixation oven before impregnation with an antibiotic solution (Vancomycin). Biocompatibility tests were performed with L132 human epithelial cells. The antibiotic release in an aqueous medium was assessed by batch type experiments using UV spectroscopy. RESULTS: Viability tests confirmed that the CDs polymers coating the Dacron fibers were not toxic towards L132 cell. Cell proliferation was similar on coated and uncoated grafts. A linear release of Vancomycin was observed over 50 days. CONCLUSION: Our results demonstrate the feasibility of coating CDs onto vascular Dacron grafts. Biological tests show no toxicity of the different cyclodextrins coated. A linear release of antibiotics was depicted over 50 days, demonstrating that cyclodextrin grafting was an efficient drug delivery system.

Anti-Bacterial Agents↗

TiO2 surface modification and characterization with nanosized PbS in dye-sensitized solar cells.

The nanoporous TiO2 films utilized in dye-sensitized solar cells (DSSCs) possess a large surface-to-volume ratio, which facilitates the adsorption of sensitizing dye and the recombination due to the high density of surface traps. In this paper, nanosized PbS was fabricated on the TiO2 films. The components of the modified TiO2 film were studied by X-ray diffraction (XRD) and electron probe microanalysis (EPMA), while the structure of the film was characterized with BET physisorption and high-resolution scanning electron microscopy (HRSEM). The results showed that the PbS particles were 2-3 nm and discrete on the surface of TiO2. Diffusion photovoltage (PV) spectroscopy was employed to study the charge separation and diffusion processes inside modified and unmodified TiO2 films. The diffusion PV signals revealed that the traps on the surface of TiO2 were extremely reduced due to the presence of PbS. The results of transient photovoltage and back I-V characteristics showed that the back reaction, that is, the recombination due to the reaction between an electron on TiO2 and the hole-transporting media, was retarded significantly.

Journal Article↗

Surface modification with protein A for uniform binding of monoclonal antibodies.

We describe optimal conditions for immobilization of two monoclonal antibodies to progesterone for solid-phase assays. Polystyrene surfaces are refined with Protein A to achieve uniform, reproducible, stable, and sterically accessible immobilization of immunoglobulins (IgG). To this end, we optimized the amount of immobilized Protein A, the pH of the medium for immobilization, the concentration of antibody, and the polystyrene surface. We also investigated three carriers for solid-phase assays: 12 X 75 mm polystyrene test tubes, Macrowells (Skatron, Inc.; suitable for processing with multiple pipettors), and microwell strips (Immulon II, Dynatech Inc.). Immunoglobulin does not appreciably dissociate from any of these solid matrices, even if the assay procedure takes several hours. Therefore, we postulate that more than one molecule of immobilized Protein A binds to IgG, or that there is an additional interaction between the antibody and the polymer surface.

Animals↗

Surface modification of diaspirin cross-linked hemoglobin (DCLHb) with chondroitin-4-sulfate derivatives. Part 1.

Synthetic methodology was developed for the preparation of chondrotin-4-sulfate reagents that could be specifically attached to the surface of diaspirin cross-linked hemoglobin (DCLHb), a chemically stabilized human hemoglobin. The surface-modified hemoglobin solutions had a significantly higher colloidal osmotic pressures (COP) than DCLHb. The P(50) of the modified DCLHb was dependent upon the reactive end group of the chondrotin-4-sulfate reagents that was used for the protein modification. Modification of DCLHb with the chondroitin-4-sulfate derivatives containing the maleimide end group 23 provided a hemoglobin with a P(50) value of 23 mmHg, while the P(50) of hemoglobins prepared from chondroitin-4-sulfate derivatives containing the aldehyde end group 13 and 18 remained unchanged from that of DCLHb.

Aspirin↗

Titanium surface modification and its effect on the adherence of Porphyromonas gingivalis: an in vitro study.

AIM: Titanium dental implants are an important treatment option in the replacement of missing teeth. Implant failures can, however, occur and may be promoted by the loss of tissue as a result of local bacterial infection (peri-implantitis). OBJECTIVES: Bacterial adherence to implant surfaces is believed to be influenced by material surface roughness and surface-free energy parameters. Consequently, the aim of this study was to modify these properties of titanium and identify what effect these modifications had on subsequent bacterial adherence. MATERIALS AND METHODS: In this study, 16 titanium samples of different roughness (R(a) 34.57-449.42 nm) were prepared using specific polishing procedures. A further six samples were chemically altered by argon plasma discharge treatment and immersion in silane solutions to produce different surface hydrophobicities. An in vitro adhesion assay using Porphyromonas gingivalis was used to assess the effect of modification on bacterial adherence. RESULTS: A significant reduction in adhesion to materials categorised as being 'very smooth' (R(a) 34.57+/-5.79 nm) was evident. This reduction did not occur with 'smooth' (R(a) 155.00+/-33.36 nm), 'rough' (R(a) 223.24+/-9.86 nm) or 'very rough' (R(a) 449.42+/-32.97 nm) surfaces. Changing material surface hydrophobicity was also not found to effect bacterial adhesion. CONCLUSIONS: Adhesion of P. gingivalis to titanium was inhibited at surface roughness levels below those generally encountered for implant collars/abutments (R(a) 350 nm). Considerations of these findings may be beneficial in the production of titanium implants in order to reduce bacterial colonisation.

Bacterial Adhesion↗

Surface modification of an ethylene-acrylic acid copolymer film: grafting amine-terminated linear and branched architectures.

Polymer films can be tailored for a specific application by modifying their surface properties. In this study, linear and branched architectures were grafted to ethylene-acrylic acid (EAA) copolymer films using the so-called grafting from approach. Dicyclohexylcarbodiimide was used to activate the carboxylic acid functionality on the surface of the EAA copolymer film before reacting it with selected di- and tri-amine compounds. The carboxylic acid functionality was subsequently regenerated by reacting the amine-grafted film with succinic anhydride. These reaction steps were then repeated to create the linear and branched architectures on the EAA film surface. The film surface resulting from each reaction step was analyzed using attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy and contact angle measurements. A systematic analysis of the ATR-FTIR results was performed to estimate the average conversion of the reaction schemes and to explain the observed contact angle results. A significant reduction in water contact angle for the EAA film grafted with a branched architecture was observed. The EAA film grafted with a linear architecture showed a marginal reduction in water contact angle when ethanol was used as a solvent for ethylenediamine. When the solvent for ethylenediamine was changed to water, the contact angle decreased noticeably. However, analysis of control films showed that the reduction in the contact angles was due to the solvent treatment. In the case of branched architectures, such reduction in contact angle due to the solvent treatment was not observed. Several control experiments were performed to ensure that the reduction in the contact angles was in fact due to the grafted species and not due to exposure to various solvents used in the reaction scheme.

Journal Article↗

Surface modification of polystyrene and poly(ethylene terephtalate) by grafting poly(N-isopropylacrylamide).

In this work, poly(N-isopropylacrylamide) (PNIPAAm) was incorporated into previously oxidized PS and PET surfaces by grafting using two photo-initiation pathways. The incorporation of PNIPAAm was observed by drop water contact angle measurements, dyeing with Methylene Blue and AFM images analysis of the virgin and modified polymers. It was verified that the grafting process depends on the chemical surface environment. The grafted surfaces are hydrophilic below 32 degrees C and hydrophobic above this temperature. The transition is due to the incorporated PNIPAAm. This characteristic gives to the grafted materials potential to be applied as biomaterials.

Journal Article↗