PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Bone Malalignment”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Medial physeal stapling for primary and secondary genu valgum in late childhood and adolescence.

We report the results of medial physeal stapling in 16 knees with primary genu valgum and 27 with secondary genu valgum. In the primary group, stapling was undertaken at a mean chronological age of 12 years in girls and 13 years in boys. The medial femoral physis was stapled in ten knees and the medial femoral and tibial physes in six knees. At skeletal maturity, all patients had excellent or good leg alignment. Secondary genu valgum is due to skeletal dysplasia, haematological or endocrine disorders, or to juvenile chronic arthritis. Stapling was at a mean chronological age of 11 years in girls and 14 years in boys. The medial femoral physis was stapled in 13 knees, the medial tibial physis in three and both in 11 knees. At skeletal maturity, 85% had excellent or good leg alignment, and correction had occurred within one year. Two of the poor results were due to staple extrusion from osteoporotic bone, and two to overcorrection. Rebound growth was minimal and unpredictable after the removal of staples. Medial physeal stapling is a suitable method of treatment for both primary and secondary genu valgum in late childhood and in adolescence. At least one year of knee growth is required to achieve correction, and care is needed to avoid overcorrection of the secondary genu valgum.

Adolescent↗

Varus derotation osteotomy for persistent dysplasia in congenital dislocation of the hip. Proximal femoral growth and alignment changes in the leg.

We studied the morphological changes in the proximal femur in 42 patients (42 hips) who had had varus derotation osteotomy of the upper femur for residual acetabular dysplasia and congenital subluxation of the hip and who did not show deformity of the head of the femur. In 19 patients the alignment of the whole leg was examined. The femoral neck-shaft angle (FNSA) at the final examination was unrelated to that immediately after operation or to the state of the acetabulum at that time. The postoperative FNSA was not related to the final result but the CE angle obtained at surgery influenced the outcome. The femoral length did not differ significantly between the unaffected and affected sides. Significant differences were found in the femorotibial angle (176.6 degrees v 174.5 degrees) and in the point of intersection between the mechanical axis and knee (65.0% v 57.2%).

Acetabulum↗

Treatment of failed Hauser procedures via modified Maquet osteotomy. Case report.

Four cases of failed Hauser procedures were treated with an osteotomy of the patellar tendon insertion and distal realignment. The patellar tendon insertion site was moved as a large bond block and positioned in neutral alignment as well as anterior to its previous position, effectively creating a "modified Maquet effect." Proximal realignment was performed in one patient. Intraoperative assessment of patellar tracking enabled accurate determination of optimal position. The clinical findings and the operative approach are described. All four patients experienced significant improvement from ther preoperative status.

Adult↗

Patellar tracking after total knee arthroplasty. The effect of tibial tray malrotation and articular surface configuration.

The effect of total knee arthroplasty (TKA) with neutrally aligned and malrotated tibial trays was studied in five fresh anatomic specimen knees. Patellar shift, tilt, and rotation, and the rotational position of the tibia were measured in normal knees and after TKA with the Ortholoc Modular knee system. Both semiconstrained and unconstrained articular surfaces were assessed in the neutral position and at anatomic, 15 degrees internal, and 15 degrees external rotation of the tibial tray. After TKA, the patellae shifted slightly medially in the early phase of knee flexion because the anterior lateral flange of the femoral component was longer than the lateral trochlea of the femur and because the tibia rotated internally. The raised lateral flange on the femoral component tilted the patella medially at full extension after TKA. The semiconstrained tray allowed minimal tibial rotation because of its articular configuration. As much as 15 degrees malrotation of the unconstrained tibial tray did not affect patellar tracking. The semiconstrained tibial tray in the neutral position had almost the same patellar tracking as the unconstrained tray, but at 15 degrees external rotation, the semiconstrained tray internally rotated the tibia, leading to medial shift of the patella. Although 15 degrees internal rotation caused external rotation of the tibia, the patella did not shift as much laterally, despite the increase in the Q angle.

Biomechanical Phenomena↗

Radiographic assessment of bony contributions to knee deformity.

Our recommendations for standing radiography of the lower limb are that assessments be standardized with respect to limb rotation and fixed relative positions of the hip, knee, and ankle. Specifically, a neutral knee rotation position should be set up, defined as alignment of the flexion plane straight ahead. For a complete appraisal, there should be both AP and lateral views in which the positioning of the patient is the same in all respects. The QPR frame greatly assists in achieving these objectives. Furthermore, the presence of a calibration system adds to the reliability and reproducibility of data by compensating for errors of position or alignment arising from the placement of the source and the film. Standardization of positioning also improves the detectability of axial-rotational deformities on comparison of AP and lateral views, providing more reliable indications of the need for CT than possible with nonstandardized short views. When a skyline patellar radiograph is added to the QPR routine, the end result is an excellent appraisal of lower limb alignment, providing a solid basis for diagnosis and planning of appropriate surgical remedies.

Adolescent↗

Deformity planning for frontal and sagittal plane corrective osteotomies.

The authors have developed a universal system of geometric deformity planning based on the mechanical or anatomic axes. The place where the axes intersect is the center of rotation angulation (CORA) of a deformity. Osteotomy level and type should be considered relative to the CORA to avoid creating secondary deformities. This type of planning is applicable to both frontal and sagittal plane deformities.

Bone Malalignment↗

New concepts in high tibial osteotomy for medial compartment osteoarthritis.

Medial compartment osteoarthritis remains a clinical challenge for the orthopedic surgeon. Accurate preoperative planning is an integral part of management. MCOA with genu varum is not a single condition but a family of related deformities. One single technique may not be appropriate for all the permutations. An individualized approach is necessary to address the many facets of this complex disorder. Treatment must begin with recognition of all of these facets through careful history and physical examination and radiographic evaluation and through preoperative planning of the location of the deformity (femur, tibia, or knee joint), level of angulation, magnitude of the deformity, and plane of the angulation. One can then formulate a treatment plan to address the problems identified. Surgeons should not become rigid in their choice of method or device, but also consider its appropriateness to address the problems to be corrected. Because the patient seeks to prolong the life of the knee before joint replacement, a comprehensive approach achieving as accurate a correction as possible should be associated with the best possible outcome. In total knee replacement, the important emphasis has been on achieving correct bony alignment and soft-tissue balance. With osteotomy, the emphasis has been on bony alignment. However, soft-tissue balance should also be considered an important element in preserving the knee in osteotomy surgery.

Bone Malalignment↗

Management of medial collateral ligament laxity.

Assessment of axial alignment with 3-foot radiographs and valgus-varus stress radiographs is important when managing symptomatic MCL instability. Realignment of the anatomical axis to 0 degrees to reduce the stress on the MCL reduces the symptomatic laxity. The assessment of MCL laxity is important when considering valgus HTO for medial compartment arthritis. A combined opening and closing wedge osteotomy reduces the size of the fragment needed and tensions the MCL at the same time. Interposition proximal tibial allografts may be used to retention combined MCL/LCL laxity as well as to correct associated deformities. As one would expect, defunctioning of the MCL in patients with valgus is best achieved using a varus distal femoral osteotomy.

Bone Malalignment↗

Accuracy of correction of complex lower-extremity deformities by the Ilizarov method.

Gradual mechanical distraction with the Ilizarov external fixator was used on 28 limbs in 23 patients to correct complex lower-extremity deformities of diverse causes. To determine the accuracy of realignment and deformity correction, the charts and radiographs were reviewed retrospectively. Preoperative long-standing anteroposterior radiographs of the entire lower extremity were compared with those obtained at the most recent follow-up visit. The parameters used to assess accuracy of correction were joint alignment and joint orientation. Alignment was determined by mechanical axis deviation (MAD) and mechanical tibiofemoral angle (mTFA). The preoperative MAD averaged 48 mm and the postoperative MAD 8.6 mm. The preoperative mTFA averaged 16 degrees and the postoperative mTFA 3 degrees. The result of deformity correction from early cases was compared with the result obtained from recent cases. Residual MAD averaged 13.2 mm in the early group and 6.4 mm in the recent group. Residual mTFA averaged 4.7 degrees in the early group and 2.2 degrees in the recent group. Gradual correction by dynamic external fixation can restore alignment and correct complex deformities with great accuracy. These results suggest the accuracy of correction increases with surgical experience.

Adolescent↗

Normal and abnormal torsional development in children.

This study presents findings in a series of 123 children with intoeing gait. The intoeing was caused by increased femoral anteversion (IFA) in 70% of the cases, and internal tibial torsion (ITT) in 30%. Rotation of the hips, thigh-foot angle, Q-angle, and computed tomography measured anteversion and tibial torsion divided the two groups very clearly. In the IFA group, 40.3% of the patients presented with an externally rotated tibia and 59.7% had an internally rotated tibia. In the ITT group, the anteversion was normal for age and the tibial torsion was significantly decreased. Eighty children who corrected their intoeing gait, and of whom 83.4% had IFA, were also reviewed: a decrease in anteversion was observed in 20.5% of the patients; 62.9% showed no decrease in anteversion.

Adolescent↗

[Lengthening, axial correction and segmental reconstruction of the extremities using the distraction method].

Between 1988 and 1992 lengthenings axial, corrections and reconstructions have been performed by distraction on lower arms, upper and lower legs in 25 patients because of deviations in length due to either congenital or acquired (multiple cartilaginous exostoses, posttraumatic conditions, congenital pseudarthrosis deformations or defects (fibula-defect, amnion-band-complex, amputation). On the average elongation amounted to 4 cm for an average installation time of the fixator system of 22 weeks and a mean duration of 25 weeks for the adaptation to full strength. Problems arose in the form of soft tissue infections at the rod perforation sites, the necessity for secondary interventions because of early fractures and for corrections of the fixator respectively. Complications compromising the expected goal of treatment did not occur. Consideration of the biological principle of distraction is essential whereas the type of fixator-system is of only minor importance.

Adolescent↗

Classification of femoral abnormalities in total hip arthroplasty.

Bony abnormalities of the femur can significantly complicate total hip arthroplasty both for the primary and revision operations. No standard nomenclature exists for the description of these femoral abnormalities. A classification system is presented to standardize nomenclature, assist in preoperative planning, and to assist in the reporting of these defects.

Bone Malalignment↗

Effect of femoral component rotation and patellar design on patellar forces.

A force transducer attached to the patella was used to measure patellar contact forces after total knee arthroplasty for neutral femoral component position and for 10 degrees internal and external femoral component rotations. Knees were cycled continuously under load from 10 degrees to 110 degrees flexion. Two designs of knee replacement with differing degrees of intrinsic tibiofemoral constraint were studied. Additionally, contact forces for a dome shaped patella and a modified dome shaped patella (a patellar component with a central projection surrounded by a peripheral flat region) were compared. When using the design with relatively high intrinsic tibiofemoral constraint, there were no significant changes in patellar contact forces after axial rotation of the femoral component. When using the design with relatively low intrinsic tibiofemoral constraint and averaging over the range of flexion angles tested, the mediolateral component of the patellar contact force increased approximately 17% after 10 degrees internal rotation compared with neutral rotation, and the normal component of the patellar contact force decreased approximately 8% after a 10 degrees external rotation compared with 10 degrees internal rotation of the femoral component. The inferosuperior component of the patellar shear force, when using the modified dome shaped patellar component, was significantly lower than for the dome shaped patella.

Aged↗