PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Fixed”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD/CAM system.

Clinical long-term success of all-ceramic dental restorations can be significantly influenced by marginal discrepancies. As a result, this in vitro study evaluated the marginal fit of alumina- and zirconia-based fixed partial dentures (FPDs) machined by the Precident DCS system. Different master steel models of three-, four- and five-unit posterior FPDs with an 0.8 mm chamfer preparation were produced. FPDs made of DC-Zirkon and In-Ceram Zirconia core ceramics were machined by the Precident DCS system. The marginal fit of the milled frameworks placed on the master steel models was determined by a replica technique using a light-body silicone to fill the discrepancies between crown and tooth and a heavy-body material to stabilize the light-body impression material. The impressions were poured into an epoxy resin material and each model was cross-sectioned with a low speed diamond saw to better visualize marginal discrepancies. The marginal fit of the FPDs was evaluated by scanning electron microscopy. The measurements of the marginal fit exhibited mean marginal discrepancies in a range between 60.5 and 74.0 microm, mean marginal gaps in a range from 42.9 to 46.3 microm, mean vertical discrepancies in a range from 20.9 to 48.0 microm and mean horizontal discrepancies in the range of 42.0 to 58.8 microm. Statistical data analysis was performed using the non-parametric test of Kruskal-Wallis and Mann-Whitney. The analysis revealed no significant differences (p>0.05) between the mean marginal gaps and vertical and horizontal discrepancies. However, for some FPDs the mean values of the marginal discrepancies were significantly different (p < or =0.05). The wide range of the measured values may be attributed to the complex geometrical design of long span FPDs and difficulties regarding the milling process of brittle ceramic materials. Based on the selection of 100 microm as the limit of clinical acceptability, the results of this study can conclude that the level of marginal fit for alumina- and zirconia-based FPDs achieved with the Precident DCS system meet the clinical requirements.

Aluminum Oxide↗

[Prosthetic rehabilitation of cleft palate patients with fixed partial dentures].

Treatment of cleft palate patients demands a well coordinated work of medical and dental specialists. In spite of the surgical and orthodontic therapy a prosthetic rehabilitation is often necessary because of missing teeth, maxillary hypoplasia, malocclusion and palatal defects. The prosthetic phase begins immediately after the orthodontic treatment. In this way the fixed partial denture replaces the retention appliance and stabilizes the achieved status. The aim of the prosthetic treatment is to improve the function of the masticatory apparatus, speech and aesthetic appearance of the patient. An important task of the prostheses is to support and lift up the upper lip and the base of the nose. There are several factors, which make the treatment difficult, like underdeveloped and collapsed maxillary arch, retrognath position of the maxilla, missing alveolar ridge, defects of the bone and mucosa, scars and stiffness of the upper lip. The maintenance of the oral hygiene with the fixed restorations is often difficult because of the stiffness of the upper lip, therefore the design of the pontic is very important especially in the cases, when the missing processus alveolaris has to be replaced in order to improve the harmony of the face.

Adolescent↗

In vivo wear of enamel by a lithia disilicate-based core ceramic used for posterior fixed partial dentures: first-year results.

PURPOSE: This study aimed (1) to test the hypothesis that no significant relationship exists between the magnitude of occlusal clenching force and wear rates of enamel opposing a new core ceramic (e.max Press, Ivoclar Vivadent) used in posterior fixed partial dentures (FPDs); and (2) to test the hypothesis that mean annual enamel wear by an experimental core ceramic is comparable to the mean annual enamel wear by enamel of 38 microm. MATERIALS AND METHODS: Baseline data were obtained for patients in addition to preliminary impressions of maxillary and mandibular teeth. Thirty ceramic FPDs were processed from a new core ceramic (e.max Press) that was hot pressed and glazed. Patients were recalled 1 year after cementation and evaluated using clinical criteria that included wear assessment of opposing teeth. Impressions were made of the opposing teeth with polyvinylsiloxane impression material and photographs were taken of intraoral occlusal contacts marked with articulating ribbon. Baseline casts and casts made at each recall exam of opposing dentitions were scanned using a 3-dimensional laser scanner (Laserscan 3D, Willytec) and evaluated for wear. A total of 21 occlusal surfaces were analyzed for the presence of wear. RESULTS: Statistical analysis using a linear and quadratic model revealed no significant relationship between occlusal forces and wear rate assuming either a linear model (R2 = 0.018) or a quadratic model (R2 = 0.023). The maximum annual wear of enamel by the glazed core ceramic (e.max Press) was 88.3 microm, which is significantly greater than the annual enamel-by-enamel wear of 38 microm (P < .0001). CONCLUSION: Further analysis with a larger sample size is needed to determine the relationship between occlusal clenching force and wear rate and the influence of other factors that cause increased wear of enamel by opposing ceramic restorations.

Adult↗

Damage mechanics and load failure of fiber-reinforced composite fixed partial dentures.

OBJECTIVES: Damage mechanics has been defined as the study of the initiation (initial failure) and accumulation of damage to and including rupture (final failure). This study was designed to evaluate the effect of increasing fiber-reinforced composite (FRC) substructure within a standardized fixed partial denture (FPD) model on the failure performance, in terms of damage mechanics. METHODS: The two FRC restorative systems, Targis/Vectris (TV) (Ivoclar Vivadent) and EverStick (ES) (Stick Tech with Gradia, GC Corp.), were used to restore the molar FPD model (1.5 mm axial and 2.0 mm occlusal reduction). Templates were used to standardize substructure designs with 0, 18, 43, and 66% cross-sectional FRC volume fraction (V(FRC)) of fiber substructure. Specimens (n = 5) were homogenized at 29 points and stored for 1 week at 37 degrees C in distilled water. Specimens were luted with calcium hydroxide, then statically loaded until failure. Initial failure (IF), final failure (FF) and the mode of failure were recorded. RESULTS: The lowest mean load to initial failure was 530 N (TV 18%) and the highest was 1208 N (ES 66%). Linear regression analysis calculated the Pearson's correlation coefficient (r) for the interactions between V(FRC) and IF (ES: r = 0.7879, TV: r = 0.6184), V(FRC) and FF (ES: r = 0.912, TV: r = 0.8152), and between IF and FF (ES: r = 0.892, TV: r = 0.7237). Unreinforced specimens universally fractured instantaneously. SIGNIFICANCE: The highest loads to initial and final failure were yielded by specimens with the highest cross-sectional V(FRC).

Calcium Hydroxide↗

Replacement of two mandibular central incisors using a zirconium resin-bonded fixed partial denture: a clinical report.

Maxillary and mandibular anterior tooth loss may cause esthetic and functional problems. Successful treatment for these situations may necessitate a minimally invasive technique to preserve sound remaining abutment tooth structure. This article describes the use of zirconium resin-bonded fixed partial denture as a conservative treatment option for the replacement of 2 mandibular central incisors.

Adult↗

All-ceramic fixed partial dentures designed according to the DC-Zirkon technique. A 2-year clinical study.

The aim of the study was to investigate whether the properties of a pre-sintered, hot isostatic post-compacted (HIP) ZrO2 are adequate for use in three-five-unit fixed partial dentures (FPDs) and to evaluate the clinical results. Twenty three-five-unit FPDs were fabricated for 18 patients on a total of 56 abutments. They were all made on abutments cut with a shoulder preparation and cemented with a zinc phosphate cement. They were clinically followed for 24 months. After 24 months all FPDs were still in use without any fractures or clinical wear but in three cases (15%) minor chip-of fractures were observed. Marginal integrity was rated excellent at 45 abutments and acceptable at 11. Within the limitations of this 2-year clinical follow-up study, FPDs made of pre-sintered HIP ZrO2 core material veneered with a compatible ceramic is an acceptable alternative in the fabrication of FPDs with the extensions investigated in this study. Special attention, however, must be paid to designing the core for an occlusal shape that provides sufficient support for the veneer.

Adult↗

Management of the isolated deformed dentinoalveolar complex by subepithelial graft and resin-bonded fixed partial denture.

Two cases in which subepithelial connective tissue grafts were used as adjuncts to definitive prosthetic reconstruction have been presented. The method for managing the deformed dentinoalveolar complex in the anterior portion of the mouth was discussed. The improved appearance coupled with the resin-bonded fixed partial denture warrant the consideration of the subepithelial graft in selected cases.

Adult↗

Ceramic implant abutments used for short-span fixed partial dentures: a prospective 2-year multicenter study.

PURPOSE: This is a 2-year report from an ongoing prospective 5-year multicenter study. The aim of the study was to evaluate the short- and long-term clinical function of CerAdapt ceramic abutments supporting short-span fixed partial dentures (FPD). MATERIALS AND METHODS: Initially, 105 Brånemark System implants were placed in a total of 32 patients at 3 different clinics. After initial healing 103 implants remained. For the support of 36 FPDs, 53 ceramic and 50 titanium abutments were connected, 19 on ceramic and 17 on titanium abutments. RESULTS: All patients remained in the study after 2 years. There was a cumulative survival rate of 97.1% for implants and a cumulative success rate of 97.2% for FPDs (94.7% for ceramic and 100% for titanium abutment-supported FPDs). One of 53 ceramic but none of 50 titanium abutments failed, giving a cumulative success rate of 98.1% and 100%, respectively, for the abutments. Soft tissue around abutments and adjacent teeth appeared healthy. More crown margins were placed submucosally at titanium (31%) than at ceramic (14%) abutments, and the level of the periimplant mucosa was relatively stable in relation to the abutment/crown. No differences were seen between ceramic and titanium abutments regarding bleeding of the periimplant mucosa. There was a minimal marginal bone loss recorded after 1 year, which was slightly more at titanium (0.4 mm) than at ceramic (0.2 mm) abutments. All patients and dentists were satisfied with the achieved esthetic result and no FPD was remade because of compromised esthetics. CONCLUSION: So far the ceramic abutments have worked very well and the 2-year results have been very encouraging for CerAdapt abutments supporting short-span FPDs. However, ceramic materials tend to undergo static fatigue, and it is therefore important to wait for the 5-year results before making any more definite statement about the long-term prognosis for CerAdapt abutments.

Alveolar Bone Loss↗

The in-vitro clinical failure of all-ceramic crowns and the connector area of fixed partial dentures: the influence of interfacial surface roughness.

OBJECTIVES: To assess the effect of interfacial surface roughness on the flexure strength and fracture mode and origin utilizing an in-vitro assessment of the clinical failure conditions expected for all-ceramic crowns and the connector area of fixed partial dentures (FPDs) using bilayered ceramic specimens tested in bi-axial flexure. METHODS: Sets of 20 bilayered composite discs, with core:dentine thickness ratio of 2:1 and interfacial surface roughnesses determined by alumina abrasion with different alumina particle sizes, were tested in bi-axial flexure with both the reinforcing core and veneering dentine loaded in tension. Mean flexure strengths, standard deviations and associated Weibull Moduli (m) were determined. Optical microscopy was employed for identification of the fracture mode and origin for the failure all-ceramic crowns and the connector area of FPDs. RESULTS: The interfacial surface roughness influenced the bi-axial flexure strength and reliability of the flexure strength data when both the reinforcing core and veneering dentine porcelain were tested in tension. The number of fracture fragments, frequency of occurrence of specimen delaminations, Hertzian cone formations and sub-critical radial cracking in the bilayered dental ceramic composite disc-shaped specimens was also dependent on the interfacial surface roughness and the surface loaded in tension. CONCLUSIONS: The fracture resistance, failure mode and failure origin in bilayered ceramics tested to represent the clinical failure mode of all-ceramic crowns and FPDs are dependent upon the interfacial surface roughness and the modulus of the material in tension.

Analysis of Variance↗

A double casting technique to minimize distortion when constructing fixed partial dentures on implants.

The casting of extensive implant superstructures that have a good passive fit may be technically demanding. A simple, 2-stage casting technique is presented that avoids common problems associated with the casting of large superstructures. The fabrication of a 7-unit metal-ceramic screw-retained fixed partial denture supported by 5 implants is used to illustrate this technique.

Dental Abutments↗

A dental laboratory study of the dimensions of metal frameworks for fixed partial dentures.

The purpose of this study was to record the dimensions of the metal substructure of metal ceramic restorations under fabrication in dental laboratories. The dimensions of the joints as well as the metal thickness of the occlusal, buccal and lingual/palatal surfaces of the abutment crowns were measured on 115 fixed partial dentures. The results showed that the greatest dimensions in a vertical direction were found in the anterior region, and in a horizontal direction in the posterior region. The occlusal, buccal and lingual/palatal surfaces of the abutment crowns often showed sub-optimal dimensions.

Denture Design↗

Interfacial strengths of various alloy surface treatments for resin-bonded fixed partial dentures.

A practical method for bonding or rebonding the resin-bonded retainer is eagerly being sought by general practitioners. This research introduces a new test apparatus for evaluating bond strength of base metal alloys after various alloy surface treatments. Five commercial base metal alloys and a resin luting cement for resin-bonded fixed partial dentures were examined. Sandblasting, oxidation, or etching treatment were determined to be effective in increasing the adhesive strength for the tested alloys. No statistical differences between various surface treatments were found for bonding of Unitbond metal. Inexpensive sandblasting, along with ultrasonic washing, provided superior bonding strengths for Biobond II and Litecast B materials. Electrochemical treatment was suitable for Wiron 77 and Lab metals.

Acid Etching, Dental↗

The in vitro failure of all-ceramic crowns and the connector area of fixed partial dentures using bilayered ceramic specimens: the influence of core to dentin thickness ratio.

AIMS: To assess the effect of core to dentine thickness ratio on the bi-axial flexure strength and fracture mode and failure origin using bilayered ceramic specimens as an in vitro assessment for all-ceramic crowns and the connector area of fixed partial dentures (FPDs). METHODS: Sets of 30 bilayered composite discs, with a core layer thickness of 1mm and with core to dentine thickness ratios of 2:1, 1:1 and 1:2, were tested in bi-axial flexure with both the reinforcing core and veneering dentine loaded in tension. Mean flexure strengths, standard deviations and associated Weibull moduli (m) were determined. Optical microscopy was employed for identification of the fracture mode and failure origin for the failure all-ceramic crowns and the connector area of FPDs. RESULTS: For a core thickness of 1mm the core to dentine thickness ratio failed to influence the bi-axial flexure strength data when both the reinforcing core and veneering dentine porcelain were tested in tension. The number of fracture fragments, frequency of occurrence of specimen delaminations, Hertzian cone formations and sub-critical radial cracking in the bilayered dental ceramic composite disc-shaped specimens were dependent on the core to dentine thickness ratio and the surface loaded in tension. SIGNIFICANCE: The fracture mode and failure origin in bilayered ceramics tested to represent the failure mode of all-ceramic crowns and FPDs was dependent upon the core to dentine thickness ratio employed. However, the conventional wisdom regarding bilayered ceramic specimens with core thicknesses greater than 1mm are not followed when the core thickness was reduced to 1mm since the fracture resistance was not dependent on the core to dentine thickness ratio.

Aluminum↗

Thermal cycling distortion of porcelain fused to metal fixed partial dentures.

STATEMENT OF PROBLEM: The initial fit of porcelain fused to metal restorations deteriorates during the firing cycle of porcelain. PURPOSE: This study evaluated thermal cycling distortion of 3-unit porcelain fused to metal frameworks at different firing stages. MATERIAL AND METHODS: A master model was designed to represent the 2 abutments of a 3-unit fixed partial denture replacing a missing mandibular molar. Standard techniques were used to fabricate 10 castings. Half of the copings were cast in a Ni-Cr alloy and the other half in a Pd-Cu alloy. Framework distortion was measured by means of inner fit changes, horizontal linear measurements of the framework length, and vertical fit changes of each retainer. Measurements were made (1) initially, (2) after degassing firing, and (3) after glaze firing. Differences between the firing cycles created distortion values of the retainers in 3 dimensions. Repeated measures ANOVA was used to analyze data statistically. RESULTS: Measured differences between the 2 firing stages ranged from -47 to 81.7 micrometer. For both alloy groups, retainers showed increase in vertical gap that implied poorer vertical fit after porcelain application. Mean values of inner fit change recorded for porcelain application firing were higher in magnitude than the values of metal-conditioning firing. In addition, no statistically significant differences were found among alloy types. CONCLUSIONS: A 3-dimensional distortion was observed both in Pd-Cu and Ni-Cr frameworks during porcelain firing cycle. The distortion seen after porcelain application firing was significantly greater than that seen after metal-conditioning firing. This result can be attributed to these factors, contamination of porcelain to the inner surface of metal coping and reduction in resilience of metal.

Analysis of Variance↗

[Clinical study of tooth-to-implant supported fixed partial dentures].

The lack of the periodontal ligaments around the implants results an ankylotic fixation. The mobility of the osseointegrated implants is only one tenth of the mobility of the natural teeth. To connect a natural tooth and an implant as abutments in a fixed restoration is a special problem in the dentistry. The aim of this study was to examine whether connecting of implants and natural teeth has any disadvantages for the abutment either implant or natural tooth. Furthermore we wanted to know if an overloading of the opposing tooth could occur because of the stiffness of the implant-bone connection. 21 partially edentulous patients, who were treated with implant supported bridges using the DenTi implant system which includes screw-shaped, commercially pure titanium implants, were examined. Plaque, calculus, gingival index, probing depth and bleeding on probing were recorded around the implants and the teeth. Mobility, sound on percussion were examined as well. In this study no disadvantageous effect of connecting teeth to implants as abutments by fixed partial dentures was found. There was no sign of a harmful effect of the implant to the opposing teeth either. The tooth-to-implant bridges function in their biological environment without affecting it adversely.

Adult↗

The effects of HEMA-monomer and air atmosphere treatment of glass fibre on the transverse strength of a provisional fixed partial denture resin.

This study focused on some mechanical properties such as the transverse strength, the maximal deflection, and the modulus of elasticity of resin reinforced with two different types of agents-treated and with untreated glass fibre, and without fibre. A Teflon mould was used to prepare six groups of specimens. Two different types of chemical modification agents, hydroxyethyl-methacrylate (HEMA)-monomer and air atmosphere were applied to create hydrophilic surfaces on the glass fibres. The flow rate was kept at two different levels, 25 and 60 mL min-1. The discharge powers of the surface treatment process were 15 or 20 W. The fibres were exposed to glow discharge conditions for the periods of 10 or 15 min. Without fibre specimens were the control group. The provisional resin was same in all groups. All the specimens were subjected to transverse testing with a cross-head speed of 5 mm min-1. The three-point load test was used to record the load of the fracture for each specimens. The Kruskal-Wallis analysis of variance was used to compare the transverse strength, the maximal deflection and the modulus of elasticity. The differences in the transverse strength and the maximal deflection between the six groups were found statistically significant but the modulus of elasticity was not statistically significant. The transverse strength of HEMA-monomer (group A) was shown the highest value (66.3 MPa). For without-fibre group, the value was 52.9 MPa. This difference was statistically significant when the Mann-Whitney U-test was used for comparing. Repairing or remaking provisional restorations can be a time-consuming endeavour. The added strength of the polymethyl methacrylate with the fibre can reduce clinical failures of provisional fixed partial dentures. The surface treatment process was increased the transverse strength and the maximal deflection. The clinical implication of chemical modification agents-coated fibres is reduced incidence of fixed provisional restoration failure.

Acrylic Resins↗

A clinical evaluation of fixed partial denture impressions.

STATEMENT OF PROBLEM: Providing the dental laboratory with an accurate replication of the hard and soft tissue of a patient is important. Therefore, it is essential to examine whether clinicians critically evaluate impressions routinely before sending them to the laboratory. PURPOSE: This study evaluated the quality of impressions sent to commercial laboratories for the fabrication of fixed partial dentures (FPD) by describing the frequency of clinically detectable errors and by analyzing correlations between the various factors involved. MATERIAL AND METHODS: A total of 193 FPD impressions were evaluated, immediately after arrival at 11 dental laboratories, by 3 calibrated examiners. The impression technique and material used, tray type, and number of prepared units were recorded for each impression. Data relating to errors and faults, including defects in material polymerization, retention to tray, tissue contact by tray, crucial areas beyond tray borders, heavy-bodied material exposure through the wash material (for double-step impressions), inadequate union of materials, retraction cords embedded in impressions, and air bubbles, voids, or tears along the margin were also documented. The data were analyzed with the Pearson chi-square test (alpha = .05). RESULTS: Of the impressions, 89.1% had 1 or more observable errors. Significant correlations were found between material type and voids or tears at the finish line (Rv = 0.17, P < .025) and between material type and polymerization problems (Rv = 0.223, P < .004). CONCLUSIONS: Within the limitations of this study, impressions made with polyethers had the most detectable errors, followed by condensation-type silicones. The high frequency of detectable errors found in impressions sent for FPD fabrication is of concern.

Chi-Square Distribution↗

A multilevel analysis of factors affecting the longevity of fixed partial dentures, retainers and abutments.

There is a methodological problem in analysis of data belonging to different hierarchical levels, e.g. patient, arch, and tooth. A method for multilevel modelling (MLM) that resolves this problem is available. This method which is presented in this article, was used to reanalyse previously published long-term treatment results concerning the longevity of fixed partial dentures, retainers and abutments. The main results were consistent, indicating that no great faults were committed when using the conventional logistic regression method. There were, however, differences when calculating the combined risks for various situations. The conventional method was found to over- and underestimate probabilities of survival in different cases, compared to the MLM method. Especially when the most negative factors were combined, the conventional method had a tendency to underestimate the risk. For example, if an abutment had the combination 'endodontically treated'; 'FPD placed by 'another dentist''; 'distal abutment'; and 'marginal bone loss > 50%'; the probability of the tooth remaining after 18-23 years was only 20% according to the MLM method but 35% according to the conventional method. It was concluded that MLM is the method of choice for many situations in dental research where data belonging to different levels are to be analysed.

Dental Abutments↗