PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Isometric”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Force-velocity shifts with repetitive isometric and isotonic contractions of canine gastrocnemius in situ.

The force-velocity (F-V) relationships of canine gastrocnemius-plantaris muscles at optimal muscle length in situ were studied before and after 10 min of repetitive isometric or isotonic tetanic contractions induced by electrical stimulation of the sciatic nerve (200-ms trains, 50 impulses/s, 1 contraction/s). F-V relationships and maximal velocity of shortening (Vmax) were determined by curve fitting with the Hill equation. Mean Vmax before fatigue was 3.8 +/- 0.2 (SE) average fiber lengths/s; mean maximal isometric tension (Po) was 508 +/- 15 g/g. With a significant decrease of force development during isometric contractions (-27 +/- 4%, P < 0.01, n = 5), Vmax was unchanged. However, with repetitive isotonic contractions at a low load (P/Po = 0.25, n = 5), a significant decrease in Vmax was observed (-21 +/- 2%, P < 0.01), whereas Po was unchanged. Isotonic contractions at an intermediate load (P/Po = 0.5, n = 4) resulted in significant decreases in both Vmax (-26 +/- 6%, P < 0.05) and Po (-12 +/- 2%, P < 0.01). These results show that repeated contractions of canine skeletal muscle produce specific changes in the F-V relationship that are dependent on the type of contractions being performed and indicate that decreases in other contractile properties, such as velocity development and shortening, can occur independently of changes in isometric tension.

Animals↗

Influence of active muscle size on sympathetic nerve discharge during isometric contractions in humans.

We tested the hypothesis that sympathetic nerve discharge to nonactive skeletal muscle (MSNA) is influenced by active muscle size during isometric contractions performed at a constant submaximal force in humans. In six subjects, MSNA (peroneal microneurography), arterial pressure, heart rate, and ratings of perceived effort were recorded before (resting control) and during isometric contractions of either a small hand muscle [1st dorsal interosseus (FDI); 2 trials (FDI1 and FDI2)] or the fore- and upper arm muscles (handgrip; 1 trial) sustained to the point of exhaustion and normalized to endurance time (te). There were no differences in resting control levels. MSNA, heart rate, arterial pressure, and perceived effort all increased similarly during the two FDI contractions. During handgrip, the rates of rise and peak increases MSNA, heart rate, and arterial pressure were much greater than during FDI (all P < 0.05), but peak levels of perceived effort were not different. These findings indicate that during voluntary isometric efforts sustained to the same performance and perceptual end points the rates of increase and final levels of MSNA, heart rate, and arterial pressure are greater during contraction of a larger muscle mass and that these responses appear to be similar during successive trials of a task when normalized to te. Thus, active muscle size can be an important factor in the regulation of sympathetic nervous system discharge and cardiovascular function during isometric muscle activity in the human.

Adult↗

Multivariate genetic analysis of maximal isometric muscle force at different elbow angles.

The maximal isometric moment at five different elbow joint angles was measured in 25 monozygotic and 16 dizygotic male adult twin pairs (22.4 +/- 3.7 yr). Genetic model fitting was used to quantify the genetic and environmental contributions to individual differences in isometric strength. Additive genetic factors explained 66-78% of the variance in maximal torque at 170-140-110 and 80 degrees flexion (extension = 180 degrees). At 50 degrees flexion, common and subject-specific environmental factors contributed equally to the variation. The contribution of unique environmental factors concurs with the level of variability in muscle activation and (dis)-comfort of torque production in the specific angle. The relative contribution of lever arm and force-length relationship in torque varies according to the angle. Because these factors might be genetic, this variability is reflected in the genetic contribution at the extreme angles of 170 and 50 degrees. Multivariate analyses suggested a general set of genes that control muscle area and isometric strength, together with a more specific strength factor. Genetic correlations were high (0.82-0.99). Genes responsible for arm-segment lengths did not contribute to muscle area nor to isometric strength.

Adolescent↗

Effects of isometric training on the elasticity of human tendon structures in vivo.

The present study aimed to investigate the effect of isometric training on the elasticity of human tendon structures. Eight subjects completed 12 wk (4 days/wk) of isometric training that consisted of unilateral knee extension at 70% of maximal voluntary contraction (MVC) for 20 s per set (4 sets/day). Before and after training, the elongation of the tendon structures in the vastus lateralis muscle was directly measured using ultrasonography while the subjects performed ramp isometric knee extension up to MVC. The relationship between the estimated muscle force and tendon elongation (L) was fitted to a linear regression, the slope of which was defined as stiffness of the tendon structures. The training increased significantly the volume (7.6+/-4.3%) and MVC torque (33.9+/-14.4%) of quadriceps femoris muscle. The L values at force production levels beyond 550 N were significantly shorter after training. The stiffness increased significantly from 67.5+/-21.3 to 106.2+/-33.4 N/mm. Furthermore, the training significantly increased the rate of torque development (35.8 +/- 20.4%) and decreased electromechanical delay (-18.4+/-3.8%). Thus the present results indicate that isometric training increases the stiffness and Young's modulus of human tendon structures as well as muscle strength and size. This change in the tendon structures would be assumed to be an advantage for increasing the rate of torque development and shortening the electromechanical delay.

Adult↗

Activation of human quadriceps femoris during isometric, concentric, and eccentric contractions.

Maximal and submaximal activation level of the right knee-extensor muscle group were studied during isometric and slow isokinetic muscular contractions in eight male subjects. The activation level was quantified by means of the twitch interpolation technique. A single electrical impulse was delivered, whatever the contraction mode, on the femoral nerve at a constant 50 degrees knee flexion (0 degrees = full extension). Concentric, eccentric (both at 20 degrees /s velocity), and isometric voluntary activation levels were then calculated. The mean activation levels during maximal eccentric and maximal concentric contractions were 88.3 and 89.7%, respectively, and were significantly lower (P < 0.05) with respect to maximal isometric contractions (95.2%). The relationship between voluntary activation levels and submaximal torques was linearly fitted (P < 0.01): comparison of slopes indicated lower activation levels during submaximal eccentric compared with isometric or concentric contractions. It is concluded that reduced neural drive is present during 20 degrees /s maximal concentric and both maximal and submaximal eccentric contractions. These results indicate a voluntary activation dependency on both tension levels and type of muscular actions in the human knee-extensor muscle group.

Adult↗

Twitch potentiation is greater after a fatiguing submaximal isometric contraction performed at short vs. long quadriceps muscle length.

Endurance time of a submaximal sustained contraction is longer when the muscle is fatigued in a shortened position. The aim of the present study was to compare central and peripheral mechanisms of fatigue after an isometric contraction of the knee extensor muscles performed at 20% maximal voluntary contraction (MVC) at two knee angles (35 degrees , short length vs. 75 degrees , long length; 0 degrees = full extension) until exhaustion. Eleven men (24 +/- 4 yr) attended two experimental randomized sessions. Endurance time was greater at 35 degrees compared with 75 degrees (974 +/- 457 vs. 398 +/- 144 s; P < 0.001) despite a similar reduction in knee extensor MVC (-28.4 +/- 16.0%, P < 0.001 vs. -27.6 +/- 18.8%, P < 0.001, respectively). Voluntary activation level was similarly depressed after the fatiguing contraction performed at the two muscle lengths (-19 +/- 16.7% at 35 degrees , P < 0.01 vs. -13.7 +/- 14.5% at 75 degrees , P < 0.01). After the fatiguing contraction, peak twitch potentiation was observed only at the short length (+31.8 +/- 17.6% at 35 degrees , P < 0.01 vs. +6.4 +/- 21.3% at 75 degrees , P > 0.05), whereas M-wave properties were similarly altered for the two angles. These results suggest that 1) central fatigue at task failure for a sustained isometric contraction was not dependent on the muscle length, and 2) the longer endurance time of a sustained isometric contraction performed at a shortened length is related to potentiation. It is suggested that the greater endurance time of a sustained isometric contraction observed at 35 degrees is related to the occurrence of potentiation at this short length, because central fatigue is similar at task failure for both tasks.

Adaptation, Physiological↗

Older adults are less steady during submaximal isometric contractions with the knee extensor muscles.

This study compared the steadiness of submaximal contractions with the knee extensor muscles in young and old adults. Twenty young and twenty old subjects underwent assessment of isometric maximum voluntary contraction (MVC), one-repetition maximum (1-RM) strength, and steadiness during isometric, concentric, and eccentric contractions with the knee extensor muscles. The old adults displayed 33% lower MVC force and a 41% lower 1-RM load. The coefficient of variation for force was significantly greater for the old adults during isometric contractions at 2, 5, and 10% of MVC but not at 50% MVC. The decline in steadiness at low forces experienced by the men was marginally greater than that experienced by the women. The steadiness of concentric and eccentric contractions was similar in young and old adults at 5, 10, and 50% of 1-RM load. Old subjects exhibited greater coactivation of an antagonist muscle compared with young subjects during the submaximal isometric and anisometric contractions. These results indicate that, whereas the ability to exert steady submaximal forces with the knee extensor muscles was reduced in old adults, fluctuations in knee joint angle during slow movements were similar for young and old adults.

Adult↗

Skeletal muscle hypertrophy in response to isometric, lengthening, and shortening training bouts of equivalent duration.

Movements generated by muscle contraction generally include periods of muscle shortening and lengthening as well as force development in the absence of external length changes (isometric). However, in the specific case of resistance exercise training, exercises are often intentionally designed to emphasize one of these modes. The purpose of the present study was to objectively evaluate the relative effectiveness of each training mode for inducing compensatory hypertrophy. With the use of a rat model with electrically stimulated (sciatic nerve) contractions, groups of rats completed 10 training sessions in 20 days. Within each training session, the duration of the stimulation was equal across the three modes. Although this protocol provided equivalent durations of duty cycle, the torque integral for the individual contractions varied markedly with training mode such that lengthening > isometric > shortening. The results indicate that the hypertrophy response did not track the torque integral with mass increases of isometric by 14%, shortening by 12%, and lengthening by 11%. All three modes of training resulted in similar increases in total muscle DNA and RNA. Isometric and shortening but not lengthening mode training resulted in increased muscle insulin-like growth factor I mRNA levels. These results indicate that relatively pure movement mode exercises result in similar levels of compensatory hypertrophy that do not necessarily track with the total amount of force generated during each contraction.

Animals↗

Parietal area 5 activity does not reflect the differential time-course of motor output kinetics during arm-reaching and isometric-force tasks.

Many single-neuron recording studies have examined the degree to which the activity of primary motor cortex (M1) neurons is related to the kinematics and kinetics of various motor tasks. This has not been explored as extensively for arm movement-related neurons in posterior parietal cortex area 5. We recorded the activity of 78 proximal arm-related neurons in area 5 of two monkeys while they used their whole arm to make reaching movements toward eight targets on a horizontal plane against an inertial load or to generate isometric forces at the hand in the same eight horizontal directions. The overall range of measured output forces was similar in the two tasks. The forces increased monotonically in the desired direction in the isometric task. In the movement task, in contrast, they showed a rapid initial increase in the direction of movement, followed by a transient reversal of forces as the hand approached the target. Many task-related area 5 neurons were tuned for the direction of motor output in the tasks, but most area 5 neurons were more strongly active or exclusively active in the movement task than in the isometric task. Furthermore, their activity at either the single cell or population level did not reflect the transient reversal of output forces during movement. In contrast, M1 neuronal activity was typically strong in both tasks and showed task-related changes that reflected the differences in the time course and directionality of force outputs between both tasks, including the transient reversal of forces in the movement task. These results show that area 5 neurons are less strongly related to the time-course of task kinetics than M1 during isometric and arm-movement tasks.

Action Potentials↗

Motor cortex neural correlates of output kinematics and kinetics during isometric-force and arm-reaching tasks.

We recorded the activity of 132 proximal-arm-related neurons in caudal primary motor cortex (M1) of two monkeys while they generated either isometric forces against a rigid handle or arm movements with a heavy movable handle, in the same eight directions in a horizontal plane. The isometric forces increased in monotonic fashion in the direction of the force target. The forces exerted against the handle in the movement task were more complex, including an initial accelerating force in the direction of movement followed by a transient decelerating force opposite to the direction of movement as the hand approached the target. EMG activity of proximal-arm muscles reflected the difference in task dynamics, showing directional ramplike activity changes in the isometric task and reciprocally tuned "triphasic" patterns in the movement task. The apparent instantaneous directionality of muscle activity, when expressed in hand-centered spatial coordinates, remained relatively stable during the isometric ramps but often showed a large transient shift during deceleration of the arm movements. Single-neuron and population-level activity in M1 showed similar task-dependent changes in temporal pattern and instantaneous directionality. The momentary dissociation of the directionality of neuronal discharge and movement kinematics during deceleration indicated that the activity of many arm-related M1 neurons is not coupled only to the direction and speed of hand motion. These results also demonstrate that population-level signals reflecting the dynamics of motor tasks and of interactions with objects in the environment are available in caudal M1. This task-dynamics signal could greatly enhance the performance capabilities of neuroprosthetic controllers.

Animals↗

Human motor-unit recruitment during isometric contractions and repeated dynamic movements.

Spike-triggered averaging was used to determine the twitch tensions and contraction times of motor units in the abductor pollicis brevis muscle of two human subjects for two directions of isometric contraction: abduction and opposition of the thumb. During isometric contractions in each direction, the threshold force for motor-unit recruitment and the twitch amplitude were correlated linearly. These data suggested that an orderly pattern of recruitment, according to increasing twitch size, describes the function of the human abductor pollicis brevis muscle for each contraction direction. Rank order of motor-unit recruitment in each isometric contraction direction was correlated, but not identical. All units contributed tension in each direction of contraction, so no clear evidence was found for task-dependent motor units. In two subjects, motor-unit recruitment order during isometric contraction of the first dorsal interosseous and abductor pollicis brevis muscles was then compared with that of motor-unit pairs in both muscles during repetitive dynamic movements. Recruitment according to increasing twitch size was largely preserved during the repetitive opening and closing of scissors. The recruitment reversals that were observed were usually between pairs of units with similar thresholds.

Electromyography↗

Muscle afferent responses to isometric contractions and relaxations in humans.

1. One hundred and two single afferents from the finger extensor muscles of humans were studied with the microneurography technique. 2. The afferents were provisionally classified as primary muscle spindle afferents (62/102), secondary spindle afferents (22), and Golgi tendon organ afferents (18) on the basis of their responses to four tests: 1) ramp-and-hold stretch, 2) 20- and 50-Hz small-amplitude sinusoidal stretch superimposed on ramp-and-hold stretch, 3) maximal isometric twitch contraction, and 4) stretch sensitization. 3. The response profiles of the three unit types were analyzed during slowly rising isometric contraction terminating with an abrupt relaxation. About 75% (61/84) of all muscle spindle afferents increased their discharge during isometric contraction, whereas the discharge was reduced for the remaining afferents. All Golgi tendon organs increased their discharge during the contraction. 4. The level of extrafusal contraction at which a spindle afferent increased its discharge rate often varied from trial to trial, speaking against a fixed fusimotor recruitment level of the individual spindle ending. 5. In 70% of the spindle afferents, a distinct burst of impulses appeared when the subject rapidly relaxed after the isometric contraction. The burst was more common and usually much more prominent with primary than secondary afferents, often reaching instantaneous discharge rates well above 100 Hz. 6. Whereas all Golgi tendon organ afferents displayed an increased discharge during the contraction phase, only one of them exhibited a rate acceleration close to the relaxation phase. However, this response could clearly be identified as being of different nature than the spindle bursts.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Changes in the temporal pattern of primary motor cortex activity in a directional isometric force versus limb movement task.

We recorded the activity of 75 proximal-arm-related cells in caudal primary motor cortex (MI) while a monkey generated either isometric forces or limb movements against an inertial load. The forces and movements were in eight directions in a horizontal plane. The isometric force generated at the hand increased monotonically in the direction of the target force level. The force exerted against the load in the movement task was more complex, including a transient decelerative phase during the movement as the hand approached the target. Electromyographic (EMG) activity of proximal-arm muscles reflected the task-dependent changes in dynamics, showing a ramp increase in activity during the isometric task and a reciprocal triphasic burst pattern in the movement task. A sliding 50-ms window analysis showed that the directionality of the EMG, when expressed in hand-centered spatial coordinates, remained stable throughout the isometric ramp but often showed a significant transient shift during the limb movements. Many cells in M1 showed corresponding significant changes in activity pattern and instantaneous directionality between the two tasks. This momentary dissociation of discharge from the directional kinematics of hand displacement is evidence that the activity of many single proximal-arm related M1 cells is not coupled only to the direction and velocity of hand motion.

Animals↗

Isotonic (dynamic) and isometric (static) effort in the assessment and evaluation of diastolic hypertension: correlation and clinical use.

We compared the effect of two exercise stress tests on blood pressure in normal and borderline populations. The aim of the trial was to determine if isometric exercise testing by handgrip can replace the isotonic exercise test in population screening for the detection of mild and latent hypertension. The study involved 150 subjects; 62 were normotensive and 88 were borderline hypertensive. No significant statistical difference was found in diastolic pressure between the tests. In normotensive subjects, the diastolic response after isotonic effort was 79.3 +/- 9.6 mm Hg and 89.0 +/- 9.7 mm Hg after the isometric test (p less than 0.05). However, both results did not pass 100 mm Hg. In borderline hypertensive patients the diastolic response to the isotonic test was 105.6 +/- 8.8 mm Hg and after the isometric test 107.7 +/- 10.6 mm Hg (NS). The results show that the handgrip isometric test can replace the complicated isotonic test for the screening detection and evaluation of hypertensives in the population.

Adult↗

Cardiovascular response to isometric exercise in normal adolescents.

The purpose of this study was to document the cardiovascular response to submaximal isometric handgrip (IHG) exercise in 32 normal adolescents. Left ventricular (LV) dimensions and systolic time intervals were recorded using echocardiography; blood pressure was measured by sphygmomanometry both at rest and during IHG exercise at 25% maximum contraction. This level of isometric exercise produced significant (p less than 0.001) increases in mean heart rate, systolic, diastolic and mean blood pressures. Despite this response LV diastolic and systolic dimensions remained unchanged during exercise; hence, stroke volume remained constant. Cardiac index increased by 22% (p less than 0.001) due to the increase in heart rate. Systemic vascular resistance did not change significantly. LV ejection indices, including shortening fraction, mean Vcf and systolic time intervals also remained unchanged, except for an increase in LV ejection time index (p less than 0.025). These data indicate that the cardiovascular response to submaximal isometric exercise in normal adolescents is similar to that reported in adults. This study demonstrates that sustained isometric stress testing in adolescents is safe and provides normal hemodynamic values.

Adolescent↗

Prolonged isometric exercise. Part 1: Effect on circulation and on renal excretion of sodium and potassium in mild essential hypertension.

The effect of stress, in the form of prolonged isometric exercise, on the circulation and on the renal excretion of sodium and potassium was studied in 18 patients with mild essential hypertension. Thirteen men and five women, aged 20 to 50 years with basal diastolic blood pressure (BP) between 90 and 110 mm Hg were matched by age, sex, and race with 18 controls who had basal diastolic BPs less than 85 mm Hg. After the subjects rested for 90 minutes, basal measurements of pulse rate, BP, and rates of sodium and potassium excretion were made. The subjects then underwent a 1-hour period of isometric exercise involving all four limbs in rotation, followed by 5 hours of rest during which the measurements were repeated at half-hourly intervals for the first 2 hours and at hourly intervals for the last 3 hours. On another day, the subjects were again studied after 1 hour of resting instead of exercise. Responses of each subject were then expressed as ratios of changes from the basal values observed on the exercise and rest days. Changes in systolic and diastolic BP and hart rate were not significantly different in the hypertensive and control groups. In hypertensive subjects, the rate of sodium and potassium excretion was decreased after isometric exercise compared with the rest day, whereas in normal subjects this response was reversed. For the first 3 hours after exercise, the cation excretion rate of the hypertensive group was significantly less than that of the control group. These results indicate that isometric exercise in mild hypertension induces prolonged renal retention of both sodium and potassium.

Adult↗

Prolonged isometric exercise. Part 2: Effect on circulation and on renal excretion of sodium and potassium in young males genetically predisposed to hypertension.

The effect of stress, in the form of prolonged isometric exercise, on the circulation and on the renal excretion of sodium and potassium was studied in 16 male medical students whose parental blood pressure (BP) was less than 140/85 mm Hg, and in 17 male students with one or two parents who had BPs greater than 150/95 mm Hg. After the subjects rested initially for 90 minutes, basal measurements were made of heart rate, BP, and the rates of sodium and potassium excretion. The subjects then underwent a 1-hour period of intermittent isometric exercise involving all four limbs in rotation, during which BP and heart rate were measured. A 5-hour period of rest followed, during which BP, heart rate, and the rate of electrolyte excretion were measured at half-hourly intervals for the first 2 hours and at hourly intervals for the last 3 hours. The precise protocol was repeated on another day in the absence of the period of isometric exercise. The electrolyte excretion responses of each subject were then expressed as the ratio of the changes from basal values observed on exercise and rest days. At no time was there any difference in systolic and diastolic BP, heart rate, and rate of sodium and potassium excretion following exercise when sons of normotensive parents were compared to the sons of hypertensive parent(s). These results indicate that the retention of sodium and potassium following isometric exercise seen in patients with hypertension does not occur in subjects genetically predisposed to hypertension and suggest that the effect is a consequence of, rather than a predisposing factor to, hypertension.

Adult↗

Calcium sensitivity of isometric tension is increased in canine experimental heart failure.

To examine the role of alterations in myofibrillar function in chronic heart failure, we determined isometric tension-pCa relations in permeabilized myocardium from a canine model of dilated cardiomyopathy (DCM) produced by chronic rapid pacing. In the initial series of experiments, seven dogs were paced at 250 beats per minute for 28.9 +/- 7.0 days, resulting in ventricular dilatation and reduced ejection fractions by echocardiography and elevated intracardiac filling pressures. Isometric tension-pCa relations were measured by using mechanically disrupted and permeabilized myocyte-sized preparations obtained from left ventricular biopsies before (n = 11) and after (n = 10) chronic rapid pacing-induced heart failure. Resting sarcomere length (SL) was set at 2.35 microns, and preparations had low end compliance (SL was 2.23 +/- 0.03 microns during maximal activation). Passive tension (2.1 +/- 1.0 versus 2.4 +/- 0.6 mN/mm2) and maximal Ca(2+)-activated tension (25.9 +/- 9.3 versus 27.8 +/- 6.8 mN/mm2) were similar for control and DCM preparations, respectively. However, the calcium sensitivity of isometric tension was increased in failing myocardium (pCa50 5.95 +/- 0.11 [DCM] versus 5.83 +/- 0.10 [control], P = .001). Treatment of myofibrillar preparations with the catalytic subunit of protein kinase A decreased calcium sensitivity of tension to a greater degree in failing preparations (shift of pCa50 from 6.04 +/- 0.06 to 5.75 +/- 0.09, n = 7) than in nonfailing preparations (5.91 +/- 0.08 to 5.74 +/- 0.07, n = 8), and isometric tension-pCa relations in the two groups were not significantly different after protein kinase A treatment.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Agonists↗