PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Library Automation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Application of robotic technology to automated sequence fingerprint analysis by oligonucleotide hybridisation.

We describe our production line for the rapid analysis of large cDNA libraries applying robotic techniques to automatically pick, amplify, array, hybridise and analyse the clones. We also outline the current state of the hybridisation techniques and describe anticipated future developments of the system. Our approach faces the large-scale analysis of cDNA clones with partial sequence analysis by oligonucleotide fingerprinting in the following way: after picking of individual colonies and arraying them automatically in quadruple density (384-well) microtitre plates, the cDNA clones are amplified by an automated waterbath polymerase chain reaction (PCR), which allows us to run about 46,000 reactions in parallel. The PCR products are automatically transferred to nylon membranes in a high density pattern using a robotic device. We routinely produce twelve 22 cm x 22 cm membranes in 90 min. Each membrane contains 20,736 clones, although much higher densities might be feasible using both miniaturized glass matrices and fluorescence based hybridisation techniques. Theoretical analysis and preliminary computer simulations indicate that about 100-200 sequence specific hybridisations of octanucleotides to about 100,000 PCR products of 1000-1500 base-pairs length will generate sufficient information for classifying the clones into groups of identical or related genes and to identify a large number of previously uncharacterized cDNA clones.

Biotechnology↗

Detection of small-molecule enzyme inhibitors with peptides isolated from phage-displayed combinatorial peptide libraries.

BACKGROUND: The rapidly expanding list of pharmacologically important targets has highlighted the need for ways to discover new inhibitors that are independent of functional assays. We have utilized peptides to detect inhibitors of protein function. We hypothesized that most peptide ligands identified by phage display would bind to regions of biological interaction in target proteins and that these peptides could be used as sensitive probes for detecting low molecular weight inhibitors that bind to these sites. RESULTS: We selected a broad range of enzymes as targets for phage display and isolated a series of peptides that bound specifically to each target. Peptide ligands for each target contained similar amino acid sequences and competition analysis indicated that they bound one or two sites per target. Of 17 peptides tested, 13 were found to be specific inhibitors of enzyme function. Finally, we used two peptides specific for Haemophilus influenzae tyrosyl-tRNA synthetase to show that a simple binding assay can be used to detect small-molecule inhibitors with potencies in the micromolar to nanomolar range. CONCLUSIONS: Peptidic surrogate ligands identified using phage display are preferentially targeted to a limited number of sites that inhibit enzyme function. These peptides can be utilized in a binding assay as a rapid and sensitive method to detect small-molecule inhibitors of target protein function. The binding assay can be used with a variety of detection systems and is readily adaptable to automation, making this platform ideal for high-throughput screening of compound libraries for drug discovery.

Alcohol Dehydrogenase↗

The effect of DOCLINE on interlibrary loan volume and patterns among health sciences libraries in Michigan: preliminary analysis.

Six years of statistics on interlibrary lending and borrowing among basic unit health sciences libraries in Michigan are examined to determine the effect of the availability of an automated interlibrary loan system, DOCLINE, on interlibrary lending volume and patterns within Michigan. A trend analysis projection of expected volume is made and the predicted value compared with the actual value following the adoption of the DOCLINE system. Interlibrary loan (ILL) volume is tested to see if yearly volume increases are statistically significant. The number of libraries changing from net lender to net borrower or the reverse after the adoption of DOCLINE is tracked. Results fail to support the expectation that DOCLINE would produce major change in ILL volume or pattern.

Data Interpretation, Statistical↗

Using Prime Editing Guide Generator (PEGG) for high-throughput generation of prime editing sensor libraries.

Prime editing enables the generation of nearly any small genetic variant. However, the process of prime editing guide RNA (pegRNA) design is challenging and requires automated computational design tools. We developed Prime Editing Guide Generator (PEGG), a fast, flexible, and user-friendly Python package that enables the rapid generation of pegRNA and pegRNA-sensor libraries. Here, we describe the installation and use of PEGG (https://pegg.readthedocs.io) to rapidly generate custom pegRNA-sensor libraries for use in high-throughput prime editing screens.

Gene Editing↗

Optimization of the synthesis of peptide combinatorial libraries using a one-pot method.

Conditions for the synthesis of synthetic peptide combinatorial libraries (SPCLs) from mixtures of amino acids were explored. In a one-pot synthesis, the effect of the starting concentrations of amino acids on the resulting library composition was studied, and the optimum balance of amino acids was determined. Protein sequencing, MALDI-TOF, and amino acid analysis were used for the evaluation of the libraries, and their relative merits-are discussed. The effects of continuous-flow automated synthesis instrumentation in conjunction with polyethylene glycol-polystyrene (PEG-PS) graft supports and various cleavage cocktails on the successful synthesis of SPCLs were examined.

Amino Acids↗

HTPS flow cytometry: a novel platform for automated high throughput drug discovery and characterization.

The flow cytometer is unique among biomedical analysis instruments because it makes simultaneous and multiple optical measurements on individual cells or particles at high rates. High throughput flow cytometry represents a potentially important multifactorial approach for screening large combinatorial libraries of compounds. Limiting this approach has been the availability of instrumentation and methods in flow cytometry for automated sample handling on the scale required for drug discovery applications. Here, we describe an automated system in which a novel patented fluidics-based pharmacology platform, the HTPS (High Throughput Pharmacological System), is coupled to a flow cytometer using a recently described plug flow-coupling valve technology. Individual samples are aspirated sequentially from microplate wells and delivered to a flow cytometer for rapid multiparametric analysis. For primary screening to detect and quantify cell fluorescence in endpoint assays, a high-speed no-wash protocol enabled processing of 9-10 cell samples/min from 96-well microplates. In an alternate primary screening format, soluble receptor ligands were sampled from microplate wells at rates of 3-4 samples/minute and successfully assessed for the ability to elicit intracellular calcium responses. Experiments with fluorescent beads validated the accurate automated production by the HTPS of exponential and linear gradients of soluble compounds. This feature enabled rapid (2- to 3-min) characterization of the intracellular calcium dose response of myeloid cells to formyl peptide as well as the quantitative relationship between formyl peptide receptor occupancy and cell response. HTPS flow cytometry thus represents a powerful high throughput multifactorial approach to increase the efficiency with which novel bioresponse-modifying drugs may be identified and characterized.

Automation↗

Streamlined system for purifying and quantifying a diverse library of compounds and the effect of compound concentration measurements on the accurate interpretation of biological assay results.

As part of an overall systems approach to generating highly accurate screening data across large numbers of compounds and biological targets, we have developed and implemented streamlined methods for purifying and quantitating compounds at various stages of the screening process, coupled with automated "traditional" storage methods (DMSO, -20 degrees C). Specifically, all of the compounds in our druglike library are purified by LC/MS/UV and are then controlled for identity and concentration in their respective DMSO stock solutions by chemiluminescent nitrogen detection (CLND)/evaporative light scattering detection (ELSD) and MS/UV. In addition, the compound-buffer solutions used in the various biological assays are quantitated by LC/UV/CLND to determine the concentration of compound actually present during screening. Our results show that LC/UV/CLND/ELSD/MS is a widely applicable method that can be used to purify, quantitate, and identify most small organic molecules from compound libraries. The LC/UV/CLND technique is a simple and sensitive method that can be easily and cost-effectively employed to rapidly determine the concentrations of even small amounts of any N-containing compound in aqueous solution. We present data to establish error limits for concentration determination that are well within the overall variability of the screening process. This study demonstrates that there is a significant difference between the predicted amount of soluble compound from stock DMSO solutions following dilution into assay buffer and the actual amount present in assay buffer solutions, even at the low concentrations employed for the assays. We also demonstrate that knowledge of the concentrations of compounds to which the biological target is exposed is critical for accurate potency determinations. Accurate potency values are in turn particularly important for drug discovery, for understanding structure-activity relationships, and for building useful empirical models of protein-ligand interactions. Our new understanding of relative solubility demonstrates that most, if not all, decisions that are made in early discovery are based upon missing or inaccurate information. Finally, we demonstrate that careful control of compound handling and concentration, coupled with accurate assay methods, allows the use of both positive and negative data in analyzing screening data sets for structure-activity relationships that determine potency and selectivity.

Biological Assay↗

Tagging gene and protein names in biomedical text.

MOTIVATION: The MEDLINE database of biomedical abstracts contains scientific knowledge about thousands of interacting genes and proteins. Automated text processing can aid in the comprehension and synthesis of this valuable information. The fundamental task of identifying gene and protein names is a necessary first step towards making full use of the information encoded in biomedical text. This remains a challenging task due to the irregularities and ambiguities in gene and protein nomenclature. We propose to approach the detection of gene and protein names in scientific abstracts as part-of-speech tagging, the most basic form of linguistic corpus annotation. RESULTS: We present a method for tagging gene and protein names in biomedical text using a combination of statistical and knowledge-based strategies. This method incorporates automatically generated rules from a transformation-based part-of-speech tagger, and manually generated rules from morphological clues, low frequency trigrams, indicator terms, suffixes and part-of-speech information. Results of an experiment on a test corpus of 56K MEDLINE documents demonstrate that our method to extract gene and protein names can be applied to large sets of MEDLINE abstracts, without the need for special conditions or human experts to predetermine relevant subsets. AVAILABILITY: The programs are available on request from the authors.

Abbreviations as Topic↗

Setup for high-throughput impedance screening of gas-sensing materials.

This paper reports on the setup for a high-throughput impedance measurement system that allows rapid screening of the electrical and dielectrical properties of solid-state sample libraries in variable atmospheres and temperatures. Using multielectrode arrays, most time-consuming steps in the workflow are parallelized. In addition, an approach for automated data evaluation of impedance spectra is presented. For reasons of verification of robust measuring results and reproducibility, screening results of a sample library composed of doped indium(III) oxide as a resistive-type gas-sensing material are discussed on the basis of the determined sensitivities focusing temperature and testing gas gradients.

Journal Article↗

Octamer-primed cycle sequencing: design of an optimized primer library.

This paper describes a novel method of primer walking using octamer oligonucleotides to prime DNA sequencing reactions. Octamer sequencing is compatible with isotopic and fluorescent sequencing chemistry, reaction conditions are optimized such that the samples can be processed in parallel, and the procedure has the potential to be automated. This strategy is faster than the traditional primer walking sequencing strategy, as the existence of a primer library allows immediate access to a primer for the next sequencing reaction, eliminating delays associated with designing and synthesizing gene-specific primers. The octamer library is comprised of optimized sequencing primers, such that octamer sequencing yields results equivalent to or better than traditional primer walking. This technology is more economical because gene-specific sequencing primers, the major cost in the reaction, are replaced by an optimized subset of frequently occurring octamers that are able to prime multiple reactions.

Anabaena↗

The evolution of research library buildings.

The principles of research library building planning established in the late 1940s emphasized flexibility of design; interspersal of books and readers; collaboration between librarians and architects; and an increased role for the library in education. Planning a medical research library in today's electronic environment requires attention to these principles as well as dealing with new and emerging technologies; economic constrains; new modes of scholarly research and communication; and the convergence of library science and information services on the campus. The social role of the library and the celebration of the book are factors common to both generations.

Architecture↗

Automated Synthesis and Purification at Bayer CropScience Chemistry Frankfurt.

The Automated Synthesis and Purification team at Bayer CropScience in Frankfurt provides services and support in the areas of synthesis and post synthesis activities for chemists. This article describes our workflow and the special robotic systems used. We produce small to medium sized compound libraries using liquid phase techniques. An example of a compound library taken from the herbicide area is given.

Agrochemicals↗

Single cell assay with an automated capillary microinjection system.

An automated capillary microinjection system with computer controlled positioning of the cells and of the capillary, and its applications and advantages are described. About 1500 injections are possible in one hour, with high reproducibility. In cytoplasmic and nuclear injections more than 90% and 85% of the cells are successfully injected. Using FITC-Dextran at a concentration of 0.5% as a fluorescently labelled coinjection marker, 99% of the cells can be retrieved in culture medium even 48 hours after injection. The coordinates of the cells are stored in the computer and accuracy in statistical evaluation of experiments is improved in comparison to the manual techniques. Methods for preparation and handling of glass capillaries were developed resulting in reproducible form and significantly reduced clogging rate. The improved characteristics offered by this system are demonstrated in studies leading to the confirmation of existence of mRNA(s) inhibiting cell proliferation. Functional screening by cell injections of cDNA libraries and of size fractionated mRNA molecules can be performed efficiently with the automated microinjection system.

Animals↗

Development of combinatorial chemistry methods for coatings: high-throughput screening of abrasion resistance of coatings libraries.

Design, validation, and implementation of an optical spectroscopic system for high-throughput analysis of combinatorially developed protective organic coatings are reported. Our approach replaces labor-intensive coating evaluation steps with an automated system that rapidly analyzes 8 x 6 arrays of coating elements that are discretely deposited on a single plastic substrate. Each coating element of the library is 10 mm in diameter and 2-5 microm thick. Performance of coatings is evaluated with respect to their resistance to wear abrasion because this parameter is one of the primary considerations in end-use applications. Upon testing, the coating materials undergo changes that are impossible to quantitatively predict using existing knowledge. Coatings are abraded using industry-accepted abrasion test methods at a single or multiple abrasion conditions followed by the high-throughput analysis of abrasion-induced light scatter. The developed automated system is optimized for the analysis of diffusively scattered light that corresponds to 0-30% haze. System precision of 0.1-2.5% relative standard deviation provides capability for the reliable ranking of coatings performance. Although the system was implemented for high-throughput screening of combinatorially developed organic protective coatings for automotive applications, it can be applied for a variety of other applications for which materials ranking can be achieved using optical spectroscopic tools.

Journal Article↗

Occurrence and characterization of actinobacteria and thermoactinomycetes isolated from pulp and board samples containing recycled fibres.

The aim of this study was to characterize the actinobacterial population present in pulps and boards containing recycled fibres. A total of 107 isolates was identified on the basis of their pigmentation, morphological properties, fatty acid profiles and growth temperature. Of the wet pulp and water sample isolates (n=87), 74.7% belonged to the genus Streptomyces, 17.2% to Nocardiopsis and 8.0% to thermoactinomycetes, whereas all the board sample isolates (n=20) were thermoactinomycetes. The identification of 53 isolates was continued by molecular methods. Partial 16S rDNA sequencing and automated ribotyping divided the Streptomyces isolates (n=31) into 14 different taxa. The most common streptomycetes were the mesophilic S. albidoflavus and moderately thermophilic S. thermocarboxydus. The Nocardiopsis isolates (n=11) belonged to six different taxa, whereas the thermoactinomycetes were mainly members of the species Laceyella sacchari (formerly Thermoactinomyces sacchari). The results indicated the probable presence of one or more new species within each of these genera. Obviously, the drying stage used in the board making processes had eliminated all members of the species Streptomyces and Nocardiopsis present in the wet recycled fibre pulp samples. Only the thermotolerant endospores of L. sacchari were still present in the final products. The potential of automated ribotyping for identifying actinobacteria was indicated, as soon as comprehensive identification libraries became available.

Actinobacteria↗

In vivo drug target discovery: identifying the best targets from the genome.

A vast number of genes of unknown function threaten to clog drug discovery pipelines. To develop therapeutic products from novel genomic targets, it will be necessary to correlate biology with gene sequence information. Industrialized mouse reverse genetics is being used to determine gene function in the context of mammalian physiology and to identify the best targets for drug development.

Animals↗

Mass spectrometry innovations in drug discovery and development.

This review highlights the many roles mass spectrometry plays in the discovery and development of new therapeutics by both the pharmaceutical and the biotechnology industries. Innovations in mass spectrometer source design, improvements to mass accuracy, and implementation of computer-controlled automation have accelerated the purification and characterization of compounds derived from combinatorial libraries, as well as the throughput of pharmacokinetics studies. The use of accelerator mass spectrometry, chemical reaction interface-mass spectrometry and continuous flow-isotope ratio mass spectrometry are promising alternatives for conducting mass balance studies in man. To meet the technical challenges of proteomics, discovery groups in biotechnology companies have led the way to development of instruments with greater sensitivity and mass accuracy (e.g., MALDI-TOF, ESI-Q-TOF, Ion Trap), the miniaturization of separation techniques and ion sources (e.g., capillary HPLC and nanospray), and the utilization of bioinformatics. Affinity-based methods coupled to mass spectrometry are allowing rapid and selective identification of both synthetic and biological molecules. With decreasing instrument cost and size and increasing reliability, mass spectrometers are penetrating both the manufacturing and the quality control arenas. The next generation of technologies to simplify the investigation of the complex fate of novel pharmaceutical entities in vitro and in vivo will be chip-based approaches coupled with mass spectrometry.

Drug Design↗