PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Effects of refractive error on detection acuity and resolution acuity in peripheral vision.

PURPOSE: To evaluate the effect of refractive error on detection acuity and resolution acuity in peripheral vision. METHODS: Detection acuity, defined as the highest spatial frequency for which luminance gratings can be discriminated from a uniform field, and resolution acuity, defined as the highest spatial frequency for which spatial patterns are perceived veridically, was determined for vertical and horizontal gratings located at 20 degrees, 30 degrees, and 40 degrees of eccentricity. Resolution was also measured for tumbling-E discrimination at these locations. Refractive state of the eye for test targets was manipulated by introducing an ophthalmic trial lens into the line of sight for the stimulus while holding accommodative state fixed. RESULTS: Detection acuity in the periphery varied significantly with the amount of optical defocus, whereas acuity for grating resolution or letter discrimination was unaffected by defocus over a large range (up to 6 D). These results are consistent with the working hypothesis that detection acuity in the periphery is limited by contrast insufficiency under normal viewing conditions, but resolution is limited by ambiguity because of neural undersampling. CONCLUSIONS: The large depth of focus for resolution acuity measured for peripheral vision indicates that spatial resolution is likely to remain sampling-limited even when peripheral refractive errors are not fully corrected, thus relaxing the methodologic requirements for obtaining noninvasive estimates of neural sampling density of the living eye in a clinical setting.

Contrast Sensitivity↗

Influence of human model resolution on computed currents induced in organs by 60-Hz magnetic fields.

The effects of human body model resolution on computed electric fields induced by 60 Hz uniform magnetic fields are investigated. A recently-developed scalar potential finite difference code for low-frequency electromagnetic computations is used to model induction in two anatomically realistic human body models. The first model consists of 204290 cubic voxels with 7.2-mm edges, while the second comprises 1639146 cubic voxels with 3.6-mm edges. Calculations on the lower-resolution model using, for example, the finite difference time domain or impedance methods, push the capabilities of workstations. The scalar method, in contrast, can handle the higher-resolution model using comparable resources. The results are given in terms of average and maximum electric field intensities and current density magnitudes in selected tissues and organs. Although the lower-resolution model provides generally acceptable results, there are important differences that make the added computational burden of the higher-resolution calculations worthwhile. In particular, the higher-resolution modelling generally predicts peak electric fields intensities and current density magnitudes that are slightly higher than those computed using the lower-resolution modelling. The differences can be quite large for small organs such as glands.

Data Interpretation, Statistical↗

[Spiral CT. Better resolution by increased pitch?].

The longitudinal resolution of spiral CT has been investigated in dependence on table increment and beam collimation by use of a phantom. The results show clearly that the pitch (ratio of table increment per tube rotation to beam collimation) alone does not allow one to draw any conclusions about the resolution. Thus, a large pitch can yield a better resolution than the pitch of 1. The individual parameters table increment and beam collimation are more relevant with regard to the resolution than the rate of pitch. An alteration of the pitch can be achieved in two different ways. An increase of the pitch by a decreased beam collimation improves the resolution. In contrast, an increase of the pitch by an increased table increment decreases the resolution. A good spatial resolution of objects with high contrast (bone, lung, enhanced vessels) needs a narrow beam collimation, even if a pitch as high as 2 is necessary for a given scanning coverage. A large pitch does not cause gaps in the data set. Moreover, the patient's radiation dose decreases.

Humans↗

Image processing based on the combination of high-resolution electron microscopy and electron diffraction.

A method of crystal structure determination by electron crystallographic image processing based on the combination of high-resolution electron microscopy (HREM) and electron diffraction is introduced. It consists of two stages: image deconvolution and resolution enhancement. In the first stage an image taken at an arbitrary defocus condition is transformed into the structure image with the resolution depending on the resolution of the electron microscope. In the second stage the image resolution is enhanced to the diffraction resolution limit by combining the electron diffraction data and using the phase extension technique so that in the final image most unoverlapped atoms can be resolved individually. The experimental diffraction intensities are corrected for approximating to square structure factors. The principle of the image processing and the procedure of diffraction intensity correction are briefly described and the results of applications are illustrated. Since the method is based on the weak phase object approximation (WPOA), the validity of WPOA is discussed by introducing an approximate image contrast theory named pseudo weak phase object approximation (PWPOA) to demonstrate the image contrast change with the crystal thickness for very thin crystals.

Copper↗

Kinetic modeling of omega-transamination for enzymatic kinetic resolution of alpha-methylbenzylamine.

A kinetic model for omega-transaminase from Bacillus thuringiensis JS64 was developed by using the King-Altman method to simulate the kinetic resolution of alpha-methylbenzylamine (alpha-MBA). Starting from a ping-pong bi-bi mechanism, a complete kinetic model including substrate inhibition only in the reverse reaction (i.e., transamination between acetophenone and L-alanine) was developed. The asymmetric synthesis of (S)-alpha-MBA proved to be difficult due to a much lower maximum reverse reaction rate than the maximum forward reaction rate, thermodynamically exergonic forward reaction (i.e., transamination between (S)-alpha-MBA and pyruvate), and the severe product and substrate inhibition of the reverse reaction. Experimental values for kinetic parameters show that the product inhibition constant of (S)-alpha-MBA is the most important parameter on determining the resolution reaction rate, suggesting that the resolution reaction rate will be very low unless (S)-alpha-MBA strongly inhibits the reverse reaction. Using the kinetic model, the kinetic resolution of alpha-MBA in aqueous buffer was simulated, and the simulation results showed a high degree of consistency with experimental data over a range of reaction conditions. Various simulation results suggest that the crucial bottleneck in the kinetic resolution of alpha-MBA lies mainly in the accumulation of acetophenone in reaction media as the reaction proceeds, whereas L-alanine exerts a little inhibitory effect on the reaction. The model predicts that removing acetophenone produced during the reaction can enhance the reaction rate dramatically. Indeed, the biphasic reaction system is capable of extracting acetophenone from the aqueous phase, showing a much higher reaction rate compared to a monophasic reaction system. The kinetic model was also useful in predicting the properties of other, better enzymes as well as the optimal concentrations of amino acceptor and enzyme in the resolution reaction.

Acetophenones↗

The influence of the resolution of reciprocal ST segment changes on in-hospital complications of acute myocardial infarction after percutaneous coronary angioplasty.

We studied 120 patients (M:F 105:15, mean age 57.5 +/- 10.1 years) with acute myocardial infarction (MI) successfully treated with percutaneous coronary angioplasty (PTCA) to analyze the influence of the resolution of the ST segment elevation and depression after intervention to 1 month composite endpoints of reinfarction or reocclusion, development of congestive heart failure (CF) and death. Sum of preintervention and postintervention ST segment elevation and depression and the rate of resolution of these ST segment elevations and depressions were recorded for every patient. A total of 17 (14.2%) composite endpoint events (events group) were recorded (7 reocclusion or recurrent MI, 9 CF, and 1 death). On univariate analysis, events group patients were older (53.3 +/- 9.9 vs. 58.8 +/- 9.1 years, P = 0.032), had lesser resolution of ST segment elevations (85 +/- 24% vs. 44 +/- 55%, P = 0.017) and depression (72 +/- 26% vs. 52 +/- 30%, P = 0.009), had greater preintervention ST segment elevation (17.49 +/- 12.95 mm vs. 28.38 +/- 20.41 mm, P = 0.045), had lower ejection fraction (59.3 +/- 10.2% vs. 43.6 +/- 9.4%, P < 0.001), and had more frequent multivessel disease (71% vs. 47%, P = 0.048) compared to the nonevents group. Time from angina to reperfusion, residual stenosis, sex, infarct location and infarct-related vessel distribution were similar. On multivariate analysis (logistic regression with backward likelihood ratio) only older age (P = 0.0752), lesser rate of resolution of ST segment depression (P = 0.0262) and lower ejection fractions (P = 0.0014) were retained as predictors of the composite endpoints. Relative risk conferred by less than 50% resolution of ST segment depressions for composite endpoints were 3.78 (95% CI 1.63-8.73). We conclude that the lack of resolution of the sum of reciprocal ST segment depressions identifies a subgroup of acute MI patients with greater morbidity after primary PTCA.

Angioplasty, Balloon, Coronary↗

High-resolution echo-planar fMRI of human visual cortex at 3.0 tesla.

Known specialized properties of the human visual cortex have been used to investigate the role of spatial resolution on fMRI using blood oxygenation level dependent (BOLD) echo-planar MRI at 3.0 tesla. The magnitude of BOLD signal changes has been examined at low (3.1 x 3.1 x 3.0 mm3) and high (0.8 x 1.6 x 3.0 mm3) resolution using both gradient-echo and spin-echo EPI. Paradigms were designed to activate primary visual cortex (V1/V2) and more specialized areas associated with detection of color (V4) and motion (V5). Sensitivity of activation maps increased at higher resolution despite the decreased total signal intensity at the smaller voxel size, presumably from reduced partial volume averaging. The greater microvascular selectivity of high-resolution spin-echo imaging enabled distinct activation patterns sensitive to motion to be detected in V1/V2 that were not apparent with gradient-echo imaging. The spatial resolution at 3.0 tesla was constrained by the size of physiological head motion relative to the voxel dimensions rather than SNR or the hemodynamic response of BOLD contrast. The higher spatial resolution at 3.0 tesla with more selective spin-echo EPI can further refine functional mapping within the cerebral cortex.

Brain Mapping↗

Correlation of high-resolution breast MR imaging with histopathology; validation of a technique.

A high-resolution three-dimensional surface gradient coil set was used to obtain magnetic resonance (MR) images of breast specimens, using a gradient-echo pulse sequence (TR/TE 1000/8 msec, flip angle 75 degrees), with 117 micrometer in-plane resolution and 1 mm slice thickness. Breast tissues were obtained from one autopsy and three surgical specimens. High-resolution breast MR images and histopathology sections (7 micrometer thickness) were acquired in the same anatomical plane. Radiographs were acquired of the sliced specimens (approximately 5 mm thick) so that images from all three methods could be correlated. It was found that in vitro high-resolution breast MRI correlated well with low-resolution microscopic histology, demonstrating normal anatomy (lobules, ducts, connective tissue strands, blood vessels) and pathology (tumor content, margins, and presence of microcalcifications) of the breast more clearly than conventional pre-gadolinium breast MRI. High-resolution breast MRI may improve specificity, when added to a conventional breast MRI protocol.

Biopsy↗

Liquid chromatographic resolution of N-acyl-alpha-amino acids as their anilide derivatives on a chiral stationary phase based on (S)-leucine.

A chiral stationary phase (CSP 1) derived from N-(3,5-dinitrobenzoyl)leucine N-phenyl N-alkylamide was used for the liquid chromatographic resolution of anilide derivatives of N-acyl-alpha-amino acids and the chromatographic resolution results were compared with those from four other commercial CSPs. The chromatographic resolution results showed that CSP 1 was most effective among five CSPs used in this study. The chiral recognition mechanism exerted by CSP 1 for the resolution of anilide derivatives of N-acyl-alpha-amino acids is proposed to involve a face-to-face pi-pi interaction and two hydrogen bonding interactions between the CSP and the analytes from the chromatographic resolution behaviors of slightly modified anilide derivatives of N-acyl-alpha-amino acids. The chiral recognition mechanism proposed is quite similar to that advanced previously for the resolution of N-(3,5-methoxybenzoyl)-alpha-amino acids on CSP 1, even though the interaction sites of the two types of analytes were totally different from each other. The apparent similarity of the two chiral recognition mechanisms was assumed to stem from the identical interaction modes of the two types of analytes with the CSP. In addition, the dependence of the enantioselectivity of anilide derivatives of N-acyl-alpha-amino acids on the length of the alkyl tail of the N-acyl group of analytes was rationalized to stem from the intercalation of the N-acyl group of the (R)-enantiomer of analytes between the tethers of the CSP.

Journal Article↗

Solvent-free optical resolution of N-methylamphetamine by distillation after partial diastereoisomeric salt formation.

Solvent-free optical resolution of N-methylamphetamine was developed by distillation after partial diastereoisomeric salt formation. From the 18 chiral acids tested by this method, five provide by this method resolution: O,O'-dibenzoyltartaric acid, O,O'-di-p-toluoyltartaric acid, 6-methoxy-alpha-methyl-2-naphthaleneacetic acid (Naproxen), the cis-permetrinic acid, and the 2-phenoxypropionic acid. Among them the O,O'-dibenzoyltartaric acid in water-free form provided the more effective resolution. The efficiency of this resolution S = 0.74 is in the range of the industrial-scale resolutions and not worse than the efficiency achieved by optical resolution via fractional crystallization.

Journal Article↗

Factors affecting flow karyotype resolution.

BACKGROUND: One of the major factors which influences the chromosome purity achievable particularly during high speed sorting is the analytical resolution of individual chromosome peaks in the flow karyotype, as well as the amount of debris and fragmented chromosomes. We have investigated the factors involved in the preparation of chromosome suspensions that influence karyotype resolution. METHODS: Chromosomes were isolated from various human and animal cell types using a series of polyamine buffer isolation protocols modified with respect to pH, salt concentration, and chromosome staining time. Each preparation was analyzed on a MoFlo sorter (DAKO) configured for high speed sorting and the resolution of the flow karyotypes compared. RESULTS: High resolution flow cytometric data was obtained with chromosomes optimally isolated using hypotonic solution buffered at pH 8.0 and polyamine isolation buffer (with NaCl excluded) between pH 7.50 and 8.0. Extending staining time to more than 8 h with chromosome suspensions isolated from cell lines subjected to sufficient metaphase arrest times gave the best result with the lowest percentage of debris generated, tighter chromosome peaks with overall lower coefficients of variation, and a 1- to 5-fold increase in the yield of isolated chromosomes. CONCLUSIONS: Optimization of buffer pH and the length of staining improved karyotype resolution particularly for larger chromosomes and reduced the presence of chromosome fragments (debris). However, the most interesting and surprising finding was that the exclusion of NaCl in PAB buffer improved the yield and resolution of larger chromosomes.

Animals↗

Theoretical versus experimental resolution in optical microscopy.

The aim of this article is to compare experimental resolution under different conditions with theoretical resolution predicted using electromagnetic diffraction theory. Imaging properties of fluorescent beads of three different diameters (0.1 microm, 0.2 microm, and 0.5 microm) as well as imaging properties of four different fluorescence-stained DNA targets (ABL gene, BCR gene, centromere 6, and centromere 17) are studied. It is shown how the dependence of the resolution on object size varies with wavelength (520 nm versus 580 nm), type of microscopy (wide-field, confocal using Nipkow disk, confocal laser scanning) and basic image processing steps (median and gaussian filters). Furthermore, specimen influence on the resolution was studied (the influence of embedding medium, coverglass thickness, and depth below the coverglass). Both lateral and axial resolutions are presented. The results clearly show that real objects are far from being points and that experimental resolution is often much worse than the theoretical one. Although the article concentrates on fluorescence imaging using high NA objectives, similar dependence can also be expected for other optical arrangements.

DNA↗

The impact of spatial resolution and respiratory motion on MR imaging of atherosclerotic plaque.

PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.

Arteriosclerosis↗

Critical role of spatial resolution in dynamic contrast-enhanced breast MRI.

The spatial resolution of three-dimensional (3D) gradient-echo T1-weighted images, from 40 women with 25 malignant and 23 benign lesions, was purposely degraded to determine the role of spatial resolution in recording, analysis, and diagnosis of dynamic contrast-enhanced breast MRI. Images were recorded and analyzed at pixel resolution according to the 3TP method (Degani et al., Nat Med 1997;3:780-782). Reduction in spatial resolution degraded the appearance of foci with fast wash-in and fast washout dynamics. This resulted in an increase in false-negative diagnoses. The sensitivity for differentiating between malignant and benign lesions, using threshold criteria defined by the 3TP analysis, of 76% decreased to 60% and 24% for a 2- and 4-fold reduction in spatial resolution, respectively, without affecting significantly the high specificity (96-100%). In order to minimize false-negative diagnoses of contrast-enhanced breast MRI and maintain high specificity, it is essential to record and analyze the dynamic behavior at high spatial resolution. J. Magn. Reson. Imaging 2001;13:862-867.

Biopsy↗

Effects of spatial and temporal resolution for MR image-guided thermal ablation of prostate with transurethral ultrasound.

PURPOSE: To describe approaches for determining optimal spatial and temporal resolutions for the proton resonance frequency shift method of quantitative magnetic resonance temperature imaging (MRTI) guidance of transurethral ultrasonic prostate ablation. MATERIALS AND METHODS: Temperature distributions of two transurethral ultrasound applicators (90 degrees sectored tubular and planar arrays) for canine prostate ablation were measured via MRTI during in vivo sonication, and agree well with two-dimensional finite difference model simulations at various spatial resolutions. Measured temperature distributions establish the relevant signal-to-noise ratio (SNR) range for thermometry in an interventional MR scanner, and are reconstructed at different resolutions to compare resultant temperature measurements. Various temporal resolutions are calculated by averaging MRTI frames. RESULTS: When noise is added to simulated temperature distributions for tubular and planar applicators, the minimum root mean squared (RMS) error is achieved by reconstructing to pixel sizes of 1.9 and 1.7 mm, respectively. In in vivo measurements, low spatial resolution MRTI data are shown to reduce the noise without significantly affecting thermal dose calculations. Temporal resolution of 0.66 frames/minute leads to measurement errors of more than 12 degrees C during rapid heating. CONCLUSION: Optimizing MRTI pixel size entails balancing large pixel SNR gain with accuracy in representing underlying temperature distributions.

Animals↗

High-resolution 3D proton spectroscopic imaging of the human brain at 3 T: SNR issues and application for anatomy-matched voxel sizes.

In a systematic study on the interdependence of linewidth, signal-to-noise ratio (SNR), and spatial resolution in 3D proton spectroscopic imaging ((1)H-SI) at 3 T, we demonstrate reduced linewidths with increased spatial resolution due to reduced magnetic inhomogeneity within the brain. High-precision quantitative data (0.75-0.094 cm(3)) were obtained for all resolutions, enabling the creation of metabolic maps that display details such as the ventricles, sulci, and gyri. High-resolution (1)H-SI allows differences in metabolic ratios to be estimated for anatomically defined regions in gray (GM) and white matter (WM). Seven distinct regions in a healthy brain were anatomically segmented and their metabolic ratios were compared quantitatively. Data from a tumor patient are also presented to demonstrate potential clinical applications. Because of the high resolution, the metabolite ratios could be determined for distinct pathologic regions within the tumor and its surroundings. The method was additionally applied to a patient with patchy Pelizaeus Merzbacher disease (PMD), and compared to single-voxel spectroscopy performed in the same session. High-resolution SI data were demonstrated in our study to allow the direct matching of anatomic and metabolic images. This may enhance the clinical value of (1)H-SI.

Adult↗

SNR improvement for multiinjection time-resolved high-resolution CE-MRA of the peripheral vasculature.

Peripheral MR angiography (MRA) should ideally provide images over a large field of view with high spatial resolution and adequate temporal resolution to accommodate differences in regional filling times. Image subtraction is usually used to remove background signals. In examination protocols involving multiple injections at multiple sites, previously injected contrast present in the mask image provides a substantial decrease in the subtraction image signal. Bolus chase methods avoid this problem but provide limited time for acquisition of high-resolution images at each station. We present here a technique applied to peripheral angiography that provides high spatial and temporal resolution while maintaining high SNR in multiple injection examinations. Undersampled projection imaging was used to increase spatial resolution relative to a previously reported technique using a Cartesian acquisition technique. Late acquisition of high spatial frequencies and temporal matched-filtering were used to increase spatial resolution and SNR, respectively. Temporal correlation analysis was applied to permit multistation examinations without mask subtraction, thus providing an additional gain in SNR relative to multistation subtraction methods. Quantitative analysis is provided to evaluate the signal and noise behavior in the matched-filtering process due to multiinjection and mask subtraction.

Computer Simulation↗

High-resolution FMRI at 1.5T using balanced SSFP.

The resolution in conventional BOLD FMRI is considerably lower than can be achieved with other MRI methods, and is insufficient for many important applications. One major difficulty in robustly improving spatial resolution is the poor image quality in BOLD FMRI, which suffers from distortions, blurring, and signal dropout. This work considers the potential for increased resolution with a new FMRI method based on balanced SSFP. This method establishes a blood oxygenation sensitive steady-state (BOSS) signal, in which the frequency sensitivity of balanced SSFP is used to detect the frequency shift of deoxyhemoglobin. BOSS FMRI is highly SNR efficient and does not suffer from image distortions or signal dropout, making this method an excellent candidate for high-resolution FMRI. This study presents the first demonstration of high-resolution BOSS FMRI, using an efficient 3D stack-of-segmented EPI readout and combined acquisition at multiple center frequencies. BOSS FMRI is shown to enable high-resolution FMRI data (1 x 1 x 2 mm(3)) in both visual and motor systems using standard hardware at 1.5 T. Currently, the major limitation of BOSS FMRI is its sensitivity to temporal and spatial field drift.

Brain Mapping↗