PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Cost analysis of ELISA, solid-phase extraction, and solid-phase microextraction for the monitoring of pesticides in water.

The implementation of a pesticide water monitoring program in South Africa is limited by a lack of financial and analytical resources. A cost analysis of three analytical methods, enzyme-linked immunosorbent assays (ELISA), solid-phase microextraction (SPME), and traditional solid-phase extraction methods (SPE), was conducted. The cost analysis assumed a hypothetical scenario in terms of the sampling area (a grape farming rural region in the Western Cape province of South Africa), sample collection (weekly grab samples collected from eight sites by an environmental health officer in a nearby town), transport of samples (via courier), and analysis (endosulfan and chlorpyrifos analysis conducted by a local higher educational institution laboratory in Cape Town). The cost per sample for the three analytical methods was determined by estimating the annual capital costs, including building and equipment, and recurrent costs, including transport, personnel, supplies, and building operating costs. At the optimal utility of resources, SPME had the lowest cost per sample (US $37), followed by SPE (US $48.50) and ELISA (US $60). Recurrent costs formed the bulk of the costs of all three methods (91-97%). The cost of supplies was particularly high for ELISA (US $34 per sample). The cost per sample estimated for all three methods is substantially lower than those quoted by other laboratories in South Africa. The low cost of SPME is particularly important because of the sensitivity and reliability of this method and the faster output compared to SPE, and SPME is recommended for the long-term monitoring of pesticide pollution.

Chlorpyrifos↗

Combined effects of humic acids and salinity on solid-phase microextraction of DDT and chlorpyrifos, an estimator of their bioavailability.

The unbound portion of dissolved hydrophobic environmental contaminants generally is presumed to be the most bioavailable to aquatic organisms. The effects of differing concentrations of Aldrich humic acid (HA) and salinity on the freely dissolved fraction of chlorpyrifos (CPF) and 4,4'-dichlorodiphenyltrichloroethane (DDT) in water were assessed through their relative uptake by solid-phase microextraction (SPME). This extraction method has been recently suggested as a valuable biomimetic tool. Increasing salinity (0-20 parts per thousand [parts per thousand]) alone had no effect on the uptake of DDT by the SPME fiber, but generally enhanced the SPME uptake of the more water soluble CPE Solid-phase microextraction uptake of DDT was decreased at an HA concentration of 10 mg/L, but 100 mg/L was required to decrease CPF uptake. Binding of CPF and DDT by HA was greatly reduced by the presence of salt at 5 to 20 parts per thousand. The extent of the HA and salinity effects appeared to be pesticide-dependent. These factors may ultimately impact the contaminant's environmental fate, transport, and bioavailability, for example, in estuarine situations.

Absorption↗

Determination of triazines in soil leachates by solid-phase microextraction coupled to gas chromatography-mass spectrometry.

A solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method was developed for the evaluation of the leachability order of selected triazines (propazine, terbuthylazine, sebuthylazine, ametryn, prometryn and terbutryn) in soil/sediment samples (organic carbon content ranging from 0.19 to 0.42%), analysing fractions collected from a soil packed microcolumn elution experiments. The procedure is fast, simple, highly sensitive and solvent free. SPME-GC-MS was also employed for the quantitative determination of triazines in the soil leachate, since the method showed good recovery yield. Detection limits were always better than 1 ng ml(-1). The method was tested on a contaminated landfill top soil. Prometryn and ametryn were identified through their MS spectra and then quantified. Terbuthylazine was used to assess recovery. Results compared well with those obtained by solvent extraction followed by HPLC-UV detection.

Gas Chromatography-Mass Spectrometry↗

High-temperature solid-phase microextraction procedure for the detection of drugs by gas chromatography-mass spectrometry.

High-temperature headspace solid-phase microextraction (SPME) with simultaneous ("in situ") derivatisation (acetylation or silylation) is a new sample preparation technique for the screening of illicit drugs in urine and for the confirmation analysis in serum by GC-MS. After extraction of urine with a small portion of an organic solvent mixture (e.g., 2 ml of hexane-ethyl acetate) at pH 9, the organic layer is separated and evaporated to dryness in a small headspace vial. A SPME-fiber (e.g., polyacrylate) doped with acetic anhydride-pyridine (for acetylation) is exposed to the vapour phase for 10 min at 200 degrees C in a blockheater. The SPME fiber is then injected into the GC-MS for thermal desorption and analysis. After addition of perchloric acid and extraction with n-hexane to remove lipids, the serum can be analysed after adjusting to pH 9 as described for urine. Very clean extracts are obtained. The various drugs investigated could be detected and identified in urine by the total ion current technique at the following concentrations: amphetamines (200 microg/l), barbiturates (500 microg/l), benzodiazepines (100 microg/l), benzoylecgonine (150 microg/l), methadone (100 microg/l) and opiates (200 microg/l). In serum all drugs could be detected by the selected ion monitoring technique within their therapeutic range. As compared to liquid-liquid extraction only small amounts of organic solvent are needed and larger amounts of the pertinent analytes could be transferred to the GC column. In contrast to solid-phase extraction (SPE), the SPME-fiber is reusable several times (as there is no contamination by endogenous compounds). The method is time-saving and can be mechanised by the use of a dedicated autosampler.

Gas Chromatography-Mass Spectrometry↗

Quantification of chloroanisoles in cork using headspace solid-phase microextraction and gas chromatography with electron capture detection.

Chloroanisoles can migrate from the cork stopper in wine bottles to the wine and give it a musty taint so it is important to find a method by which they can be determined. The aim of this paper is to develop a method for quantifying 2,4-dichloroanisole, 2,6-dichloroanisole, 2,4,6-trichloroanisole, 2,3,4,6-tetrachloroanisole and 2,3,4,5,6-pentachloroanisole in cork using headspace solid-phase microextraction and gas chromatography with electron capture detection. After we had prepared the cork standards that were so essential to the work we optimised the parameters that most influence headspace solid-phase microextraction: fibre coating, vial volume, cork, kind and volume of solvent to help the extraction, extraction temperature and time, ionic strength and stirring. The method quantifies the total amount of chloroanisoles in cork stoppers (natural, agglomerated, agglomerated with disks and sparkling wine stoppers), at suitable concentrations so that the capacity of these compounds to give wine a musty taint can be evaluated. The quantification limits are: 2,6-dichloroanisole (8.6 ng/g), 2,4,6-trichloroanisole (0.8 ng/g), 2,4-dichloroanisole (3.5 ng/g), 2,3,4,6-tetrachloroanisole (0.6 ng/g), 2,3,4,5,6-pentachloroanisole (0.8 ng/g). The other quality parameters are: recoveries (90.3-105.8%), repeatability (4-13% (RSD expressed)) and intermediate precision (5-14% (RSD expressed)).

Anisoles↗

Biotransformation of (R)-(+)- and (S)-(-)-citronellol by Aspergillus sp. and Penicillium sp., and the use of solid-phase microextraction for screening.

The biotransformation of (R)-(+)- and (S)-(-)-citronellol by fungi was studied. For screening experiments, solid-phase microextraction (SPME) was used as analytical sampling technique. It was found that sporulated surface cultures of Aspergillus niger were able to convert the substrate into cis- and trans-rose oxides and nerol oxide. The relative contents in the headspace SPME extract of the three bioconversion products cis- and trans-rose oxide and nerol oxide were up to 54, 21 and 12%, respectively. Rose oxide is found in minor amounts in some essential oils, such as Bulgarian rose oil and geranium oil and contributes to its unique odor. It is one of the most important fragrance materials in perfumery in creating rosy notes. Other bioconversion products were 6-methyl-5-hepten-2-one, 6-methyl-5-hepten-2-ol, limonene, terpinolene, linalool and alpha-terpineol. These bioconversion reactions were confirmed by sporulated surface cultures on larger scale and sampling by dynamic headspace sweep and steam distillation solvent extraction. The same conversions were noticed with A. tubingensis and Penicillium roqueforti. This bioconversion was enantioselective since more of the chiral cis- than trans-rose oxide was obtained (cisitrans ratio up to 95/5). Submerged liquid cultures of P. roqueforti yielded two unidentified metabolites after conversion of citronellol (yield up to 5%). The stability and acid-catalyzed conversion of citronellol was also investigated. No chemical oxidation or auto-oxidation products were detected in acidified liquid control broths up to pH 3.5. However, when control tests were run with solid media, acid-catalyzed conversion of the substrate to small amounts of cis- and trans-rose oxides, nerol oxide, linalool and alpha-terpineol was observed at pH 3.5 and when heat treatment (steam distillation solvent extraction) was applied.

Acyclic Monoterpenes↗

Analysis of methoxypyrazines in wine using headspace solid phase microextraction with isotope dilution and comprehensive two-dimensional gas chromatography.

This study reports an optimized headspace-solid phase microextraction (HS-SPME) method for the determination of methoxypyrazines in wine. Analysis was performed by using comprehensive two-dimensional gas chromatography with novel detection capabilities, including nitrogen phosphorus detection (GC x GC-NPD) and time-of-flight mass spectrometry (GC x GC-TOFMS). In the latter, stable isotope dilution was performed for the quantitation of 2-methoxy-3-(2-methylpropyl) pyrazine (IBMP), using labelled 2-(2H3)methoxy-3-(2-methylpropyl)pyrazine (d3-IBMP) as the internal standard, and resolution of the two analogues was facilitated using the deconvolution capabilities of the TOFMS. This research represents the first report of HS-SPME with isotope dilution and GC x GC-TOFMS (GC x GC-IDTOFMS). Analysis by GC x GC-NPD enabled detection limits of 0.5 ng/L for the quantitation of IBMP, which was superior to that obtained using GC x GC-IDTOFMS (1.95 ng/L). Nevertheless, both methods were adequately sensitive for real wine analysis, yielding highly comparable IBMP concentrations of 26.1 and 27.8 ng/L, respectively, from a Sauvignon blanc wine. The complexity of the real wine headspace was simplified as a result of selective detection using GC x GC-NPD and, in the case of GC x GC-IDTOFMS, the use of extracted ion chromatograms (EICs).

Chromatography, Gas↗

Solid-phase microextraction and gas chromatography-mass spectrometry for rapid characterisation of semi-hard cheeses.

A headspace solid-phase microextraction (HS-SPME) method in combination with gas chromatography-mass spectrometry (GC-MS) has been used for extraction and identification of components of the volatile fraction of "Provola dei Nebrodi", a typical semi-hard Sicilian cheese. Cheese samples from different producers and at different ripening stages have been examined. The effects of various conditions (e.g. sample volume, sample headspace volume, sample heating temperature, extraction time, etc.) on extraction efficiency were studied in order to optimise the technique. The technique used made it possible to identify 61 components: fatty acids from C(2) to C(14) and their esters, aldehydes, alcohols, methyl ketones, delta-lactones, aromatic compounds, hydrocarbons and terpenes. The main components were butanoic, hexanoic and octanoic acids. The linear free fatty acids (FFA) from C(2) to C(10) were quantified by using the standard addition method. Calibration curves constructed for the FFA spiked into cheese were highly linear with a correlation coefficient R(2) > 0.998. Significant statistical differences (P> or =0.05) were evident for the even-carbon-number fatty acids during ripening.

Animals↗

Air sampling of aromatic hydrocarbons in the presence of ozone by solid-phase microextraction.

Effects of ozone on air sampling of standard gas mixtures of aromatic hydrocarbons were tested using solid-phase microextraction (SPME). Standard concentrations of ozone ranging from 10 ppb (v/v) to 6400 ppm (v/v) were generated using an in-house built ozone generator based on corona discharge. Effects of temperature, discharge voltage, and oxygen flow on the ozone generation were tested. The working dc voltage had the greatest effect on generated ozone concentration and was proportional to the ozone concentration. Generation temperature and oxygen flow rate were inversely proportional to ozone concentrations. Produced ozone was mixed with standard benzene, toluene, ethylbenzene, and xylenes (BTEX) gas at less than 100 ppb (v/v). Air samples were collected with poly(dimethylsiloxane) (PDMS) 100 microm SPME fibers and analyzed by gas chromatography (GC)-flame ionization detection (FID) and GC-MS. Significant reductions of BTEX concentrations were observed. In addition, some products of BTEX-ozone-oxygen reactions were identified. SPME worked well as a rapid sampler for BTEX and BTEX-ozone-oxygen reaction products. No significant deterioration of the PDMS coating and no significant reduction of absorption capacity were observed after repeated exposure to ozone.

Air↗

Laboratory and field validations of a solid-phase microextraction device for the determination of ethylene oxide.

Laboratory and field evaluations were performed to validate a solid-phase microextraction (SPME) device that was used as a diffusive sampler. Hydrogen bromide (HBr) was loaded onto the carboxen-polydimethylsiloxane (CAR-PDMS) fiber for the determination of ethylene oxide (EtO) with on-fiber derivatization. For laboratory evaluations, known concentrations of ethylene oxide around the threshold limit values (TLV)/time-weighted average and specific relative humidities (RHs) were generated by syringe pumps in a dynamic generation system. The SPME diffusive samplers and the commercially available 3M 3551 passive monitors were placed side-by-side in an exposure chamber which was designed to allow measurement of face velocities, temperatures, exposing vapor concentrations, and RHs. Field validations with both SPME diffusive sampler and 3M 3551 passive monitors were also performed. The correlations between the results from both SPME device and 3M 3551 passive monitor were found to be linear (r > 0.9699) and consistent (slope approximately equal to 1.12 +/- 0.07). However, the variations of diffusion coefficients at different temperatures needs to be considered and the adjustment of sampling constant was a must when sampling at temperatures different from 25 degrees C.

Chemistry Techniques, Analytical↗

Air/polymer distribution coefficients for polycyclic aromatic hydrocarbons by solid-phase microextraction sampling.

Two methods to estimate distribution coefficients (K) between air and poly(dimethylsiloxane) (PDMS) coating of solid-phase microextraction (SPME) fibers for eight low molecular polycyclic aromatic hydrocarbons (PAHs) there are presented. The PDMS phases were used for determination of the coefficients according to equilibrium theory with help of a developed static calibration system (SCS). Another way to estimate the coefficients is based on the use of a linear relationship between the logarithm of the coefficients (log K) and linear temperature-programmed retention indexes (LTPRI) of the compounds without necessity to calibrate. The log K values for both of methods ranged from 5.2 (naphthalene) to 8.9 (pyrene) at 22 degrees C. Relative standard deviation (R.S.D.) of log K for each compound determined by static calibration was no more than 5.3%. R.S.D. of retention times for LTPRI indices did not exceed 0.28% for repeated injection. All experiments were implemented on a GC-MS system.

Air↗

Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in paints followed by gas chromatography-flame ionization detection.

Solid-phase microextraction (SPME) with a disposable ionic liquid (IL) coating was developed for headspace extraction of benzene, toluene, ethylbenzene, and xylenes (BTEX) in paints. The SPME fiber was coated with IL prior to every extraction, then the analytes were extracted and desorbed on the injection port of gas chromatography, and finally the IL coating on the fiber was washed out with solvents. The coating and washing out of IL from the fiber can be finished in a few minutes. This disposable IL-coated fiber was applied to determine BTEX in water-soluble paints with results in good agreement with that obtained by using commercially available SPME fibers. For all the four studied paints samples, the benzene contents were under the detection limits, but relatively high contents of toluene, ethylbenzene and xylenes (56-271 microg g(-1)) were detected with spiked recoveries in the range of 70-114%. Compared to the widely used commercially available SPME fibers, this proposed disposable IL-coated fiber has much lower cost per determination, comparable reproducibility (RSD < 11%), and no carryover between each determination. Considering that IL possess good extractability for various organic compounds and metals ions, and that task-specific IL can be designed and synthesized for selective extraction of target analytes, this disposable IL coating SPME might has great potential in sample preparation.

Benzene↗

Poly(methacrylic acid-ethylene glycol dimethacrylate) monolith in-tube solid phase microextraction coupled to high performance liquid chromatography and analysis of amphetamines in urine samples.

In-tube solid-phase microextraction (SPME) based on a poly(methacrylic acid-ethylene glycol dimethacrylate) monolithic capillary column was investigated for the extraction of amphetamine, methamphetamine and their methylenedioxy derivatives. The monolithic capillary column showed high extraction efficiency towards target analytes, which could be attributed to its larger loading amount of extraction phase than conventional open-tubular extraction capillaries and the convective mass transfer procedure provided by its monolithic structure. The extraction mechanism was studied, and the results indicated that the extraction process of the target analytes was involved with hydrophobic interaction and ion-exchange interaction. The polymer monolith in-tube SPME-HPLC system with UV detection was successfully applied to the determination of amphetamine, methamphetamine and their methylenedioxy derivatives in urine samples, yielding the detection limits of 1.4 - 4.0 ng/mL. Excellent method reproducibility (RSD < 2.9%) was found over a linear range of 0.05-5 microg/mL, and the time for the whole analysis was only approximately 25 min. The monolithic capillary column was reusable in coping with the complicated urine samples.

Adsorption↗

Sol-gel-based solid-phase microextraction and gas chromatography-mass spectrometry determination of dextromethorphan and dextrorphan in human plasma.

A novel solid-phase microextraction (SPME) method was developed for isolation of dextromethorphan (DM) and its main metabolite dextrorphan (DP) from human plasma followed by GC-MS determination. Three different polymers, poly(dimethylsiloxane) (PDMS), poly(ethylenepropyleneglycol) monobutyl ether (Ucon) and polyethylene glycol (PEG) were synthesized as coated fibers using sol-gel methodologies. DP was converted to its acetyl-derivative prior to extraction and subsequent determination. The porosity of coated fibers was examined by SEM technique. Effects of different parameters such as fiber coating type, extraction mode, agitation method, sample volume, extraction time, and desorption condition, were investigated and optimized. The method is rapid, simple, easy and inexpensive and offers high sensitivity and reproducibility. The limits of detection are 0.010 and 0.015 ng/ml for DM and DP, respectively. The precisions for both analytes are below 5% (n=5). The correlation coefficient was satisfactory (r(2)>0.99) for both DM and DP. Linear ranges were obtained from 0.03 ng/ml to 2 microg/ml for DM and from 0.05 ng/ml to 2 microg/ml for DP.

Dextromethorphan↗

Application of solid-phase microextraction combined with derivatization to the enantiomeric determination of amphetamines.

The utility of combining chiral derivatization and solid-phase microextraction (SPME) for the enantiomeric analysis of primary amphetamines by liquid chromatography has been investigated. Different derivatization/extraction strategies have been evaluated and compared using the chiral reagent o-phthaldialdehyde (OPA)-N-acetyl-l-cysteine (NAC) and fibres with a Carbowax-templated resin coating. Amphetamine, norephedrine and 3,4-methylenedioxyamphetamine (MDA) were used as model compounds. On the basis of the results obtained, a new method is presented based on the derivatization of the analytes in solution followed by SPME of the OPA-NAC derivatives formed. The proposed conditions have been applied to determine the compounds of interest at low ppm levels (<or=10 microg/ml) in aqueous and urine samples. Data on the linearity, reproducibility, sensitivity and selectivity are given. The utility of the described procedure for the quantification of amphetamine, norephedrine and MDA enantiomers in different kind of samples is also discussed.

Amphetamines↗

Assessment of polycrystalline graphites as sorbents for solid-phase microextraction of nonionic surfactants.

Two polycrystalline graphites (pencil lead and glassy carbon) were used as sorbents for solid-phase microextraction of a nonionic alkylphenol ethoxylate surfactant (Triton X-100). Analyses were performed by reversed-phase HPLC-fluorescence detection. The presence of the benzene ring in the congeners of Triton X-100 also allowed their direct detection at lambda(ex) = 230 nm and lambda(em) = 310 nm. Variables such as time of adsorption, time of desorption and concentration of surfactant in water were evaluated. The method limit of detection was found to be 0.5 microg/l for Triton X-100, with a linear dynamic range of 0.5-150 microg/l. Results were compared to those obtained using polymeric fibers such as PDMS/DVB and Carbowax/TPR. The chemical resistance and low cost of the polycrystalline graphites are advantageous over commercially available SPME fibers.

Graphite↗

Solid-phase microextraction from small volumes of sample in a glass capillary.

A new sampling method is proposed for solid-phase microextraction (SPME), in which the extraction is carried out in a glass capillary containing a few microliters of sample. When an adsorption-type fiber is used for SPME, the equilibrium between aqueous sample and coating can be described by a Langmuir isotherm. Since the total amount of analytes and coexisting substances stays at a low level in a small volume of sample, the linear concentration range of analytes will be extended for SPME to be applied in quantification and the interference caused by sample matrix will be reduced. In addition, sampling in a capillary has a short diffusion distance and extraction equilibrium is established in 5-10 min. It is important in clinical analysis and therapeutic drug monitoring to be able to analyse sample volumes of samples. The feasibility of the new sampling method is demonstrated by the extractions of p-hydroxybenzaldehyde and a synthetic solution containing 1-naphthol, paeonol and 1-naphthylamine.

Chromatography, Gas↗

Novel benzo-15-crown-5 sol-gel coating for solid-phase microextraction.

A novel dihydroxy-terminated benzo-15-crown-5 was synthesized and applied to prepare a solid-phase microextraction (SPME) fiber coating with sol-gel technology. The optimization of the sol-gel process was studied. The coating method with sol-gel was improved and completed in one run, which economized materials and allowed easier control of the fiber thickness. The repeatability of coating fiber to fiber was better than 4.94% (RSD). The surface of the fiber coating was well-distributed and an electron microscopy experiment suggested a porous structure for crown ether coating, providing high surface areas and allowing for high extraction efficiency. The coating has a high thermal stability (350 degrees C), long lifetime and can stand solvent (organic and inorganic) rinsing due to the chemical binding between the coating and the fiber surface. Non-polar benzene, toluene, ethylbenzene, xylenes, chlorobenzenes, polar phenolic compounds and arylamines were used to evaluate the character of the fiber coating by headspace SPME-gas chromatography technology. For phenols, the linear concentrations ranged from 5 to 1000 microg/l, the detection limits were between 0.05 and 1 microg/l, and the RSD was less than 5%. The addition of benzo-crown ether not only increases the thermal stability of the fiber coating, but also enhances the selectivity of the fiber coating. Compared with commercially available SPME fibers poly(dimethylsiloxane) and polyacrylate, the few phases showed better selectivity and sensitivity towards non-polar and polar aromatic compounds.

Amines↗