PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 397 records · Page 22Linked to original sources

Miniature radio-frequency mobility analyzer as a gas chromatographic detector for oxygen-containing volatile organic compounds, pheromones and other insect attractants.

A high electric field, radio-frequency ion mobility spectrometry (RF-IMS) analyzer was used as a small detector in gas chromatographic separations of mixtures of volatile organic compounds including alcohols, aldehydes, esters, ethers, pheromones, and other chemical attractants for insects. The detector was equipped with a 2 mCi 63Ni ion source and the drift region for ion characterization was 5 mm wide, 15 mm long and 0.5 mm high. The rate of scanning for the compensation voltages was 60 V s(-1) and permitted four to six scans to be obtained across a capillary chromatographic elution profile for each component. The RF-IMS scans were characteristic of a compound and provided a second dimension of chemical identity to chromatographic retention adding specificity in instances of co-elution. Limits of detection were 1.6-55 x 10(-11) g with an average detection limit for all chemicals of 9.4 x 10(-11) g. Response to mass was linear from 2-50 x 10(-10) g with an average sensitivity of 4 pA ng(-1). Separations of pheromones and chemical attractants for insects illustrated the distinct patterns obtained from gas chromatography with RF-IMS scans in real time and suggest an analytical utility of the RF-IMS as a small, advanced detector for on-site gas chromatographs.

Chromatography, Gas↗

[Application of molecular systematics to study of bacterial cultures consuming volatile organic compounds].

A range of species of four mixed bacterial cultures was studied by molecular systematics methods with the use of 16S rRNA genes. The cultures had been developed for application in minireactors, to degrade volatile organic compounds (VOCs): ethyl benzene, m-xylene, styrene, and o-xylene. A sample of 30 plasmid rDNA clones was obtained for each of the mixed cultures. The clones were analyzed by RFLP according to two restriction sites. Major variants of the 16S-rDNA sequences, corresponding to the most abundant species, were determined for each association. Sequencing of four clones of predominant 16S-rDNAs showed that the culture consuming ethyl benzene was dominated by Pseudomonas fluorescens; o-xylene, by Achromobacter xylosoxydans; styrene, by Pseudomonas veronii; and m-xylene, by Delftia acidovorans. Minor components of all four cultures were generally similar. They included species of the genera Sphingobacter, Rhizobium, Mesorhizobium, Pedobacter, and Paenibacillus. Sampling sequencing of genes for 16S rRNA cloned from total genomic DNA allowed quantitative determination of the composition of actual bacterial associations consuming VOCs in minireactors.

Bacteria↗

Modeling the cytochrome P450-mediated metabolism of chlorinated volatile organic compounds.

Comparative molecular field analysis (CoMFA), a three-dimensional quantitative structure-activity relationship (3D-QSAR) paradigm, has been used to analyze the metabolic rates, as intrinsic clearance, of a series of chlorinated volatile organic compounds (VOCs). A comparison between 3D-QSAR and conventional Hansch-type QSAR is provided. To develop predictive 3D-QSARs for metabolism, the standard CoMFA model based on steric and electrostatic potential fields must be supplemented with hydropathic and molecular orbital information also in the form of three-dimensional fields. A mechanistic interpretation of chlorinated VOC metabolism by cytochrome P450 isozymes is provided as a rationalization for the inclusion of multiple fields in the CoMFA 3D-QSAR model. Models of this type have practical utility in the development of generalized physiologically-based pharmacokinetic models, as well as the rational, structure-based, design and/or selection of compounds for use in the in vivo and in vitro metabolic studies.

Cytochrome P-450 Enzyme System↗

Use of partition models to evaluate guidelines for mixtures of volatile organic compounds.

Partition models based on the octanol-air parition coefficients and associated quantitative structure-activity relationships (QSARs) have been developed to describe the triggering of odor response and nasal irritation by common volatile organic compounds (VOCs). This study made use of the QSARs developed by Hau and Connell (1998, Indoor Air 8, 23-33) and Hau et al. (1999, Toxicol. Sci. 47, 93-98) to evaluate risk-based guidelines on the airborne concentrations of common VOCs in the nonindustrial environment. A new concept referred to as the "apparent internal threshold concentration" was developed for evaluating the odor and nasal pungency responses to a typical low-concentration VOC mixture described by Otto et al. (1990, Neurotoxicol. Teratol. 12, 649-652). The assessment indicated that odor can be detected at a total VOC concentration of about 3 mg/m(3), consistent with the findings of Molhave et al. (1991, Atmos. Environ. 25, 1283-1293). Nasal pungency, according to our assessment, should not ocur at a total concentration of 25 mg/m(3), which is apparently in conflict with the findings of Molhave (1986, ASHRAE Trans. 92(1A), 306-316). It can be inferred from this investigation that pure nasal pungency without the influence of odor is unlikely to result from exposure to low-concentration VOC mixtures typically found in the nonindustrial environment.

Air Pollutants↗

Sensory eye irritation in humans exposed to mixtures of volatile organic compounds.

Eight subjects participated in a controlled eyes-only exposure study of human sensory irritation in ocular mucosal tissue. The authors investigated dose-response properties and the additive effects of three mixtures of volatile organic compounds. The dose-response relationships for these mixtures showed increases in response intensity as concentration increased. Replication of exposure did not result in significantly different dose- response relationships. Moreover, the result implied that components of the three mixtures interacted additively to produce ocular irritation, a result referred to as simple agonism. Finally, the authors addressed the comparability of two methods to measure sensory irritation intensity (visual analogue scale and a comparative scale). The results indicated that the two rating methods produced highly comparable results.

Adult↗

Odor and volatile organic compound removal from wastewater treatment plant headworks ventilation air using a biofilter.

Laboratory-scale experiments and field studies were performed to evaluate the feasibility of biofilters for sequential removal of hydrogen sulfide and volatile organic compounds (VOCs) from wastewater treatment plant waste air. The biofilter was designed for spatially separated removal of pollutants to mitigate the effects of acid production resulting from hydrogen sulfide oxidation. The inlet section of the upflow units was designated for hydrogen sulfide removal and the second section was designated for VOC removal. Complete removal of hydrogen sulfide (H2S) and methyl tert-butyl ether (MTBE) was accomplished at loading rates of 8.3 g H2S/(m3 x h) (15-second empty bed retention time [EBRT]) and 33 g MTBE/(m3 x h) (60-second EBRT), respectively. In field studies performed at the Hyperion Treatment Plant in Los Angeles, California, excellent removal of hydrogen sulfide, moderate removal of nonchlorinated VOCs such as toluene and benzene, and poor removal of chlorinated VOCs were observed in treating the headworks waste air. During spiking experiments on the headworks waste air, the percentage removals were similar to the unspiked removals when nonchlorinated VOCs were spiked; however, feeding high concentrations of chlorinated VOCs reduced the removal percentages for all VOCs. Thus, biofilters offer a distinct advantage over chemical scrubbers currently used at publicly owned treatment works in that they not only remove odor and hydrogen sulfide efficiently at low cost, but also reduce overall toxicity by partially removing VOCs and avoiding the use of hazardous chemicals.

Air Pollutants↗

Determination of volatile organic compounds in different microenvironments by multibed adsorption and short-path thermal desorption followed by gas chromatographic-mass spectrometric analysis.

A multiphase assurance approach was developed for the accurate and precise determination of volatile organic compounds (VOCs) in different microenvironments. This approach includes (i) development of a method including adsorption of VOCs onto a multisorbent media followed by short-path thermal desorption (SPTD) pre-concentration and gas chromatography (GC) coupled to a mass spectrometry (MS) quantification, (ii) validation of the sampling and analytical method and (iii) validation of the data using a multidimensional procedure. Tenax TA and Carbopack B sorbent combinations were used to collect 102 individual VOCs ranging from C5 to C12. Method parameters including thermal desorption temperature, desorption time and cryofocusing temperature were optimized. The average recoveries and method detection limits (MDL) for the target analytes were in the range 80-100% and 0.01-0.14 ppbv, respectively. The method also showed good linearity (R2 > 0.99) and precision (<8%) values. Validation of the method was performed under real environmental conditions at a gas station, in an office and a residential household to examine the influence of variation in meteorological conditions such as temperature and relative humidity and a wide range of VOC concentrations. The sampling and analytical method resulted in successful determination of VOC in different microenvironments. Finally, validation of the data was performed by assessing fingerprint and time series plots and correlation matrices together with meteorological parameters such as mixing height, wind speed and temperature. The data validation procedure provided detection of both faulty data and air pollution episodes.

Adsorption↗

Comparison of methods for determination of volatile organic compounds in drinking water.

Comparison of four methods including liquid-liquid extraction (LLE), direct aqueous injection (DAI), purge and trap (PAT) and head space (HS) were carried out in this work for determination of volatile organic compounds (VOCs) including trihalomethanes (THMs) in drinking water. This comparison is made especially to show the advantages and disadvantages and specifically the different detection limits (DL) that can be obtained for a given type of analysis. LLE is applicable only for determination of the THMs concentrations, while DAI, PAT, HS methods with different DL each of them are applicable for all VOCs, with PAT to be the most sensitive. Sampling apparatus and procedure for all these methods except of PAT are very simple and easy, but possible disadvantages for LLE and DAI are the low sensitivity and especially the detection only of THMs with LLE.

Chemistry Techniques, Analytical↗

A combined approach for the evaluation of a volatile organic compound emissions inventory.

Emissions inventories significantly affect photochemical air quality model performance and the development of effective control strategies. However, there have been very few studies to evaluate their accuracy. Here, to evaluate a volatile organic compound (VOC) emissions inventory, we implemented a combined approach: comparing the ratios of carbon bond (CB)-IV VOC groups to nitrogen oxides (NOx) or carbon monoxide (CO) using an emission preprocessing model, comparing the ratios of VOC source contributions from a source apportionment technique to NOx or CO, and comparing ratios of CB-IV VOC groups to NOx or CO and the absolute concentrations of CB-IV VOC groups using an air quality model, with the corresponding ratios and concentrations observed at three sites (Maryland, Washington, DC, and New Jersey). The comparisons of the ethene/NOx ratio, the xylene group (XYL)/NOx ratio, and ethene and XYL concentrations between estimates and measurements showed some differences, depending on the comparison approach, at the Maryland and Washington, DC sites. On the other hand, consistent results at the New Jersey site were observed, implying a possible overestimation of vehicle exhaust. However, in the case of the toluene group (TOL), which is emitted mainly from surface coating and printing sources in the solvent utilization category, the ratios of TOL/ NOx or CO, as well as the absolute concentrations revealed an overestimate of these solvent sources by a factor of 1.5 to 3 at all three sites. In addition, the overestimate of these solvent sources agreed with the comparisons of surface coating and printing source contributions relative to NOx from a source apportionment technique to the corresponding value of estimates at the Maryland site. Other studies have also suggested an overestimate of solvent sources, implying a possibility of inaccurate emission factors in estimating VOC emissions from surface coating and printing sources. We tested the impact of these overestimates with a chemical transport model and found little change in ozone but substantial changes in calculated secondary organic aerosol concentrations.

Air Pollutants↗

Online volatile organic compound measurements using a newly developed proton-transfer ion-trap mass spectrometry instrument during New England Air Quality Study--Intercontinental Transport and Chemical Transformation 2004: performance, intercomparison, and compound identification.

We have used a newly developed proton-transfer ion-trap mass spectrometry (PIT-MS) instrument for online trace gas analysis of volatile organic compounds (VOCs) during the 2004 New England Air Quality Study-Intercontinental Transport and Chemical Transformation study. The PIT-MS instrument uses proton-transfer reactions with H3O+ ions to ionize VOCs, similarto a PTR-MS (proton-transfer reaction mass spectrometry) instrument but uses an ion trap mass spectrometer to analyze the product ions. The advantages of an ion trap are the improved identification of VOCs and a near 100% duty cycle. During the experiment, the PIT-MS instrument had a detection limit between 0.05 and 0.3 pbbv (S/N = 3 (signal-to-noise ratio)) for 2-min integration time for most tested VOCs. PIT-MS was used for ambient air measurements onboard a research ship and agreed well with a gas chromatography mass spectrometer). The comparison included oxygenated VOCs, aromatic compounds, and others such as isoprene, monoterpenes, acetonitrile, and dimethyl sulfide. Automated collision-induced dissociation measurements were used to determine the contributions of acetone and propanal to the measured signal at 59 amu; both species are detected at this mass and are thus indistinguishable in conventional PTR-MS.

Air Movements↗

Evaluation of purge-and-trap-high-resolution gas chromatography-mass spectrometry for the determination of 27 volatile organic compounds in marine water at the ng l(-1) concentration level.

Purge-and-trap combined with high-resolution gas chromatography and detection by mass spectrometry was evaluated for the analysis of 27 volatile organic compounds (VOCs) in marine water samples down to ng l(-1) concentration levels. The target compounds included chlorinated alkanes and alkenes, monocyclic aromatic hydrocarbons and chlorinated monocyclic aromatic hydrocarbons and covered a wide range of VOCs of environmental interest. Limits of detection ranged from 0.15 ng l(-1) to 6.57 ng l(-1) for all VOCs, except for dichloromethane (41.07 ng l(-1)), chloroform (19.74 ng l(-1)), benzene (22.05 ng l(-1)) and 1,4-dichlorobenzene (20.43 ng l(-1)). Precision and accuracy were determined at a concentration level of 25.97 to 66.68 ng l(-1). Besides method validation, emphasis was put on quality control and assessment during routine determination of VOCs in marine water samples. Analytical quality control charts were plotted for all VOCs and a standard addition test was performed, as proposed by the QUASIMEME (Quality Assurance of Information in Marine Environmental Monitoring Programmes in Europe) working group. The analytical charts were incorporated in a working scheme containing guidelines to be applied during routine determinations, ensuring the long time reliability of the analytical method. Results yielded by the QUASIMEME interlaboratory exercise on organohalogen measurements in seawater are presented. The exercise was attended by seven out of eight laboratories who agreed to participate. Samples taken along the Scheldt estuary, from Breskens (The Netherlands) to Temse (Antwerp, Belgium) were analysed according to the developed technique. Concentrations as low as 0.33 ng l(-1) (1,2-dichloropropane) were detected near the mouth of the river Scheldt, while concentrations up to 326 ng l(-1) for tetrachloroethene and 461 ng l(-1) for cyclohexane were found in the vicinity of Antwerp.

Gas Chromatography-Mass Spectrometry↗

Determination of volatile organic compound patterns characteristic of five unifloral honey by solid-phase microextraction-gas chromatography-mass spectrometry coupled to chemometrics.

We report the evaluation of the floral origin of honey by analysis of its volatile organic compounds (VOCs) profile, joined with the use of combined pattern recognition techniques. Honey samples, from five floral origins, were analyzed by headspace solid-phase microextraction-gas chromatography-mass spectrometry, selecting 35 VOCs out of the entire profiles, which were analyzed by hierarchical cluster analysis (HCA), stepwise discriminant analysis (SDA), and K-nearest-neighbor (KNN). Both HCA and SDA were used as exploratory tools to select a group of VOCs representing similitude and differences among studied origins. Thus, six out of 35 VOCs were selected, verifying their discriminating power by KNN, which afforded 93% correct classification. Therefore, we drastically reduced the amount of compounds under consideration but kept a good differentiation between floral origins. Selected compounds were identified as octanal, benzeneacetaldehyde, 1-octanol, 2-methoxyphenol, nonanal, and 2-H-1-benzopyran-2-one. The analysis of VOC profiles, coupled to HCA, SDA, and KNN, provides a feasible alternative to evaluate the botanical source of honey.

1-Octanol↗

Evaluation of multi-walled carbon nanotubes as an adsorbent for trapping volatile organic compounds from environmental samples.

A type of purified multi-walled carbon nanotubes (PMWCNTs) prepared by catalytic decomposition of methane, with a surface area of 98 m2/g, was evaluated as an adsorbent used for tapping volatile organic compounds (VOCs). The performance in evaluation was based on breakthrough volumes (BTVs) and recoveries of selected VOCs. PMWCNTs were also used as a trap packing material to adsorb VOCs purged from spiked water sample. Due to their porous structure, PMWCNTs were found to have much higher BTVs than that of Carbopack B, a graphitized carbon black with the same surface area as PMWCNTs. The recoveries of the tested VOCs trapped on PMWCNTs ranged from 80 to 110%, and not affected by the humidity of purge gas. The results indicate that PMWCNTs are a potential useful adsorbent for direct trapping VOCs from air samples and may be a supplement to VOCARB 3000, a commercially available trap, in purge-and-trap system to preconcentrate VOCs from water samples.

Adsorption↗

Volatile organic compounds in exhaled air from patients with lung cancer.

Using a specially developed breath collection technique and computer-assisted gas chromatography/mass spectrometry (GC/MS), we have identified in the exhaled air of lung cancer patients several volatile organic compounds that appear to be associated with the disease. The GC/MS profiles of 12 samples from lung cancer patients and 17 control samples were analyzed by using general computerized statistical procedures to distinguish lung cancer patients from controls. The selected volatile compounds had sufficient diagnostic power in the GC/MS profiles to allow almost complete differentiation between the two groups in a limited patient population.

Adenocarcinoma↗

Determination of chlorinated volatile organic compounds in water and municipal wastewater using headspace-solid phase microextraction-gas chromatography.

The aim of this work was to develop a fast and simple analytical method for the determination of 14 chlorinated volatile organic compounds (VOCs) in water and wastewater samples. Headspace-solid-phase microextraction (HS-SPME) and gas chromatography (GC) were used for the determination of the VOCs. The extraction parameters were investigated in order to optimize the HS-SPME-GC method. The quality parameters of the method were also investigated.

Chromatography, Gas↗

Wet scrubber analysis of volatile organic compound removal in the rendering industry.

The promulgation of odor control rules, increasing public concerns, and U.S. Environmental Protection Agency (EPA) air regulations in nonattainment zones necessitates the remediation of a wide range of volatile organic compounds (VOCs) generated by the rendering industry. Currently, wet scrubbers with oxidizing chemicals are used to treat VOCs; however, little information is available on scrubber efficiency for many of the VOCs generated within the rendering process. Portable gas chromatography/mass spectrometry (GC/MS) units were used to rapidly identify key VOCs on-site in process streams at two poultry byproduct rendering plants. On-site analysis was found to be important, given the significant reduction in peak areas if samples were held for 24 hr before analysis. Major compounds consistently identified in the emissions from the plant included dimethyl disulfide, methanethiol, octane, hexanal, 2-methylbutanal, and 3-methylbutanal. The two branched aldehydes, 2-methylbutanal and 3-methylbutanal, were by far the most consistent, appearing in every sample and typically the largest fraction of the VOC mixture. A chlorinated hydrocarbon, methanesulfonyl chloride, was identified in the outlet of a high-intensity wet scrubber, and several VOCs and chlorinated compounds were identified in the scrubbing solution, but not on a consistent basis. Total VOC concentrations in noncondensable gas streams ranged from 4 to 91 ppmv. At the two plants, the odor-causing compound methanethiol ranged from 25 to 33% and 9.6% of the total VOCs (v/v). In one plant, wet scrubber analysis using chlorine dioxide (ClO2) as the oxidizing agent indicated that close to 100% of the methanethiol was removed from the gas phase, but removal efficiencies ranged from 20 to 80% for the aldehydes and hydrocarbons and from 23 to 64% for total VOCs. In the second plant, conversion efficiencies were much lower in a packed-bed wet scrubber, with a measurable removal of only dimethyl sulfide (20-100%).

Air Pollutants↗

Stabilities of 58 volatile organic compounds in fused-silica-lined and SUMMA polished canisters under various humidified conditions.

Fused-silica-lined (FSL) canisters and SUMMA polished (SUMMA) canisters were compared for the recoveries and the stabilities of 58 volatile organic compounds (VOCs) at low ppbv (volume/volume) levels under various humidified conditions using a three-stage preconcentration method followed by GC-MS analysis. The target VOCs included non-polar VOCs (e.g. halogenated hydrocarbons and aromatic hydrocarbons) and polar VOCs (e.g. alcohols, ketones, esters, ethers, nitriles and thiols). The three-stage preconcentration method was initially optimized for simultaneous analysis of non-polar and polar VOCs because determination of canister stability is dependent on the accuracy of analytical measurements. The method showed good linearity over the concentration range from 1 to 25 ppbv for all target analytes, and the correlation coefficients were higher than 0.9974. The method detection limits ranged from 0.023 to 0.39 ppbv. The test mixtures loaded in both type of canisters (n = 3) had concentrations of 1.7-2.5 ppbv per compound at ambient pressure under various humidified conditions (%RH = 1.6, 8.0, 27, 39, 53 and >99% with excess water present). All canister samples were initially analyzed on day 0 (after 6-12 h). The effect of competitive adsorption of water vapor and polar VOCs on active sites of interior surface was remarkably observed for SUMMA canisters. Polar VOCs had a greater requirement for water vapor to be present. The RH percentages that ensured good recovery on day 0 were RH > 8% for non-polar VOCs and RH > 27% for polar VOCs (except alcohols under the condition of RH > 99%). All thiols were not recovered from SUMMA canisters under all conditions. FSL canisters showed good recoveries of more than 86% for all VOCs under all conditions on day 0 (except alcohols under the condition of RH > 99%). The recoveries of alcohols in both canisters under the condition of RH > 99% displayed relatively low recoveries in the range 25-76% because of the partitioning effect into condensed water. The canister samples under the conditions of RH 8.0, 27, 53 and > 99% were analyzed for the stability test on days 3, 7, 14 and 28 after loading. All non-polar VOCs were reasonably stable in the FSL canisters under all examined conditions over 28 days. However, several polar VOCs that have relatively lower vapor pressure, e.g. MIBK, butyl acetate and alcohols except ethanol, showed unstable characteristics under relatively dry conditions (RH 8 and 27%) during 28 days. RH > 53% was needed to ensure good stabilities of all analytes except thiols with the recoveries of > 80% over 28 days for both canisters. Although the FSL canister showed good recoveries of more than 86% for thiols on day 0, drastic degradations were observed after day 3 and they were not detected after day 14.

Air Pollutants↗

Demonstration of proton-transfer reaction time-of-flight mass spectrometry for real-time analysis of trace volatile organic compounds.

A proton-transfer reaction mass spectrometer based on time-of-flight mass spectrometry is described. This instrument couples a radioactive ion source and drift tube with a reflectron time-of-flight mass spectrometer. Volatile organic compounds in the gas phase with concentrations at the parts per billion by volume level can be detected in a matter of seconds, and crucially, the multichannel data acquisition in TOF-MS means that this detection sensitivity is available in all mass channels simultaneously. The typical mass resolution (m/Deltam) is in excess of 1000. The performance of the instrument is demonstrated using urban air measurements and a linear response/calibration test.

Air Pollutants↗