PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ATMOSPHERIC PRESSURE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Rapid screening procedures for the hydrolysis products of chemical warfare agents using positive and negative ion liquid chromatography-mass spectrometry with atmospheric pressure chemical ionisation.

Qualitative screening procedures have been developed for the rapid detection and identification of the hydrolysis products of chemical warfare agents in aqueous samples and extracts, using liquid chromatography-mass spectrometry with positive and negative atmospheric pressure chemical ionisation (APCI). Previously reported screening procedures, which used positive APCI or electrospray ionisation (ESI), were modified by using LC conditions that allowed acquisition of positive and negative ion mass spectra. APCI was generally found to be more robust than ESI, probably due to variable adduct ion formation with ESI, depending on the condition of the sample and the system. Negative APCI provided selective detection of acidic analytes and allowed facile differentiation of alkyl alkylphosphonic acids from isomeric dialkyl alkylphosphonates. The combination of positive and negative APCI, using a C18 column and water-methanol mobile phase modified with ammonium formate, provides a rapid screening procedure for chemical warfare agent degradation products, with limits of detectability in the range 10-100 ng/ml. In the case of proficiency test samples, where analyte concentrations are in the range 1-10 ppm, introduction of the sample by infusion may provide an even faster preliminary screening procedure.

Atmospheric Pressure↗

Analysis of acetaminophen glucuronide conjugate accompanied by adduct ion production by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

Liquid chromatography-mass spectrometry (LC-MS) is an effective method for the analysis of polar compounds. A coupling of LC-MS, which is used under conventional conditions, and atmospheric-pressure chemical ionization (APCI), which applies mild ionization for the analysis of water-soluble drug conjugates, would offer a very convenient method. The APCI method is effective for ionizing low- and medium-polarized compounds, but not for highly polarized compounds. In this study, we have tried derivatization of carboxyl group of glucuronic acid, to which direct ionization is difficult to apply under the APCI method, was conducted using glucuronides. Methyl ester derivatives were found to be effectively ionized. Furthermore, acetaminophen glucuronide conjugate was investigated in detail. Methyl ester derivatives of acetaminophen glucuronide conjugate (ACEG) were detected at m/z 373 as O(2) adduct ion [M+O(2)](-) in the negative mode, and p-nitrophenyl beta-D-glucuronide (PNPG) demonstrated ionization behaviors very similar to ACEG. Quantitation of ACEG was examined using PNPG as an internal standard, and satisfactory results were obtained for the recovery test and quantification.

Acetaminophen↗

Determination of fluoroquinolones in chicken tissues by LC-coupled electrospray ionisation and atmospheric pressure chemical ionisation.

The aim of this work was to develop a method for determining seven quinolones (ciprofloxacin, danofloxacin, enrofloxacin, sarafloxacin, difloxacin, oxolinic acid and flumequine) in chicken muscle by LC coupled to MS. Two ionisation techniques, ESI and atmospheric pressure chemical ionisation (APCI) were compared using standard solutions. LOD and LOQwere determined under the optimised conditions for the two sources. The ESI was found the best for the purpose. The optimised method (LC-ESI-MS) was validated for the simultaneous analysis of the quinolones regulated by European Community in spiked chicken tissues, using norfloxacin as internal standard. Recoveries obtained varied in the range 60-109%. This method was compared with LC-UV method established previously.

Animals↗

Determination of polar pesticides with atmospheric pressure chemical ionisation mass spectrometry-mass spectrometry using methanol and/or acetonitrile for solid-phase desorption and gradient liquid chromatography.

Thirty-seven polar pesticides, mainly triazines, phenylurea herbicides and phenoxy acids, were determined by LC-atmospheric pressure chemical ionisation MS-MS with methanol and acetonitrile as the organic modifiers. For most pesticides, detection limits were the same irrespective of the modifier. However, for the phenylurea herbicides, propachlor, carbetamide, triadimefon, triadimenol, triethylcitrate, benzothiazole and metazachlor, the results were much poorer in the presence of acetonitrile; in several cases, no meaningful results were obtained at all. When carrying out trace enrichment of 100 ml water samples on a 10x2 mm I.D. solid-phase extraction precolumn containing a polymeric sorbent, rapid desorption with a small volume of pure organic solvent and the introduction of a T-piece in between the solid-phase extraction precolumn and the analytical column was necessary. Aliquots of 300 microl of acetonitrile were optimal for the complete desorption of all analytes from the sorbent. With methanol as the modifier and when using an identification criterion of three ions, the detection limits for most analytes, in the full-scan mode, were 10-100 ng/l. The linearity of the procedure, which was tested at the 0.1 and 1 microg/l levels, was satisfactory in the positive, but not in the negative ionisation mode. The procedures were used to analyse surface water samples.

Acetonitriles↗

Identification of acylated xanthone glycosides by liquid chromatography-atmospheric pressure chemical ionization mass spectrometry in positive and negative modes from the lichen Umbilicaria proboscidea.

The xanthoside composition of the crude extract of Umbilicaria proboscidea (L.) Schrader was characterized using LC-UV diode array detection and LC-atmospheric pressure chemical ionization (APCI) MS methods. The presence of acylated xanthone-O-glucosides was determined by both positive and negative ion LC-APCI-MS methods. Based on UV and MS spectral data and NMR spectroscopy, a total of 14 compounds (6-O-acylated umbilicaxanthosides A and B) were identified in U. proboscidea for the first time. In order to further develop the applicability of LC-MS techniques in phytochemical characterization, the effect of different ionization energy on fragmentation was studied using APCI. The optimal ionization conditions were achieved in positive ion APCI by using ammonium acetate buffer and in negative ion APCI by using formic acid (pH 4).

Acylation↗

Choosing between atmospheric pressure chemical ionization and electrospray ionization interfaces for the HPLC/MS analysis of pesticides.

An evaluation of over 75 pesticides by high-performance liquid chromatography/mass spectrometry (HPLC/MS) clearly shows that different classes of pesticides are more sensitive using either atmospheric pressure chemical ionization (APCI) or electrospray ionization (ESI). For example, neutral and basic pesticides (phenylureas, triazines) are more sensitive using APCI (especially positive ion). While cationic and anionic herbicides (bipyridylium ions, sulfonic acids) are more sensitive using ESI (especially negative ion). These data are expressed graphically in a figure called an ionization-continuum diagram, which shows that protonation in the gas phase (proton affinity) and polarity in solution, expressed as proton addition or subtraction (pKa), is useful in selecting APCI or ESI. Furthermore, sodium adduct formation commonly occurs using positive ion ESI but not using positive ion APCI, which reflects the different mechanisms of ionization and strengthens the usefulness of the ionization-continuum diagram. The data also show that the concept of "wrong-way around" ESI (the sensitivity of acidic pesticides in an acidic mobile phase) is a useful modification of simple PKa theory for mobile-phase selection. Finally, this finding is used to enhance the chromatographic separation of oxanilic and sulfonic acid herbicides while maintaining good sensitivity in LC/MS using ESI negative.

Atmospheric Pressure↗

Determination of the mycotoxin moniliformin in cultures of Fusarium subglutinans and in naturally contaminated maize by high-performance liquid chromatography-atmospheric pressure chemical ionization mass spectrometry.

A LC-MS method employing triethylamine as ion-pairing reagent for the determination of moniliformin in culture material and naturally contaminated maize samples is described. Mass spectrometric detection of moniliformin was accomplished following atmospheric pressure chemical ionization to yield the deprotonated molecular ion [M-H]- at m/z 97. The moniliformin response was found to be linear over the injected range 10 ng to 700 ng and a detection limit of 10 ng was attainable at a signal-to-noise (S/N) ratio of 4. Five South African strains of Fusarium subglutinans were grown on maize kernels and moniliformin extracted with an acetonitrile-water (95:5) mixture. Following sample clean up with reversed-phase (C18) solid-phase extraction cartridges, the extracts were subjected to LC-MS analysis. Triethylamine was used as an ion-pair reagent and found to improve the retention characteristics of moniliformin without any detrimental effects to the instrument. Moniliformin concentrations ranged between 130 mg/kg and 1460 mg/kg culture. Application of this method to naturally contaminated maize samples from Transkei showed that it was capable of measuring moniliformin levels down to 10 micrograms/kg in selected moldy maize cobs. This is the first report on the application of LC-MS to the analysis of moniliformin in cultures of F. subglutinans and in naturally contaminated maize.

Atmospheric Pressure↗

Development of a simplified method for the simultaneous determination of retinol, alpha-tocopherol, and beta-carotene in serum by liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization.

A new and simple method for the determination of fat-soluble vitamins (retinol, alpha-tocopherol, and beta-carotene) in human serum was developed and validated by using liquid chromatography-tandem mass spectrometry with atmospheric pressure chemical ionization (LC-APCI-MS-MS). Different solvent mixtures were tested to obtain deproteinization and extraction of the analytes from the matrix. As a result, a volume of 240 microL of a 1:1 (v/v) ethanol/ethyl acetate mixture added to 60 microL of serum was found to be suitable for both protein precipitation and antioxidants solubilization, giving the best recovery for all three analytes. Deproteinized samples (20 microL) were injected after dilution, without the need for concentration or evaporation to dryness and reconstruction of the sample. Vitamins were separated on a C-8 column using a 95:5 (v/v) methanol/dichloromethane mixture and ionized in the positive-ion mode; detection was performed in the selected-reaction monitoring mode. Linearity of the LC-APCI-MS-MS method was established over 5 orders of magnitude for retinol and alpha-tocopherol, whereas in the case of beta-carotene it was limited to 4 orders. Lower limits of quantitation were 1.7, 2.3, and 4.1 nM for retinol, alpha-tocopherol, and beta-carotene, respectively. Serum concentrations of retinol, alpha-tocopherol, and alpha+beta-carotene determined in a group of healthy volunteers were 2.48, 38.07, and 0.50 microM, respectively, in samples collected in winter ( n=122) and 2.69, 45.88, and 0.90 microM during summer ( n=66).

Adult↗

Atmospheric pressure ionisation mass spectrometric fragmentation pathways of noscapine and papaverine revealed by multistage mass spectrometry and in-source deuterium labelling.

Two opium alkaloids, noscapine and papaverine, show good response as [M+H]+ ions in positive ion electrospray mass spectrometry and atmospheric pressure chemical ionisation mass spectrometry. The two compounds exhibit markedly different fragmentation pathways and behaviour under multistage mass spectrometry (MSn), with papaverine displaying a wealth of ions in MS2 and noscapine providing a single dominant ion at each stage of MSn prior to MS4. Elucidation of the fragmentation pathways using the MSn capability of the ion trap was aided by spraying the analytes in 2H2O to incorporate an isotopic label. Simplex optimisation allowed optimum trapping and fragmentation parameters to be determined, leading to a six-fold improvement in response for one transition and a seven-fold improvement for one transition sequence.

Atmospheric Pressure↗

Thin organic films by atmospheric-pressure ion deposition.

Interest in thin films of functional organic materials has increased enormously in recent years because of the wide range of possible applications. Here we report an experimental setup for processing various organic materials into thin structured films under atmospheric pressure. The technique is based on an electrospray process. Microdroplets are initially formed and dried, generating ions that are extracted by electrostatic lenses. Thin structured films are then produced by the deposition of the resulting ion beam onto a moveable target. The technique offers several interesting features, including precise control of film thicknesses. We have also made experiments to investigate structured deposition, this being the first step towards the production of thin films where in all three dimensions the chemical composition can be chosen at will. This might provide a simple approach towards creating thin structured films and composites that are currently unattainable.

Atmospheric Pressure↗

Simultaneous quantification of alpha-tocopherol and four major carotenoids in botanical materials by normal phase liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry.

A rapid and sensitive method for the simultaneous quantification of alpha-tocopherol, beta-carotene, beta-cryptoxanthin, lutein and zeaxanthin in botanical materials has been developed using normal phase liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (NP-LC-APCI-MS/MS). A systematic extraction procedure for different botanical materials was described and the extraction solvents were matched with normal-phase LC requirement. Quantification was performed by using the external standards and standard calibration curves were linear between 35 and 8505 ng/mL for alpha-tocopherol, 64-15,552 ng/mL for beta-carotene, 40-9720 ng/mL for beta-cryptoxanthin, 70-17,010 ng/mL for lutein and 64-15,552 ng/mL for zeaxanthin with regression coefficient r2 > 0.9996. The limits of quantification (LOQ) were 35, 64, 40, 70 and 66 ng/mL for alpha-tocopherol, beta-carotene, beta-cryptoxanthin, lutein and zeaxanthin, respectively.

Atmospheric Pressure↗

[Spontaneous pneumothorax and atmospheric pressure].

In order to assess factors associated with spontaneous pneumothorax (SP), mainly climatic changes, a prospective study was undertaken of 62 SP episodes among patients admitted to our hospital during a two-year period, from January 1994 to January 1996. Atmospheric pressure (AP) changes were analyzed, with daily recording of the number of unusual changes in AP (increases above 95th percentile and decreases below 5th percentile) and how many of these changes were followed by some episode of spontaneous pneumothorax during the following five days. To measure the degree of this association between the emergence of pneumothorax and exposure to unusual changes I AP, the relative risk (RR) was calculated. A total of 77 unusual AP changes were observed, 17 of which concurred with the emergence of 8 episodes of SP during the following five days, with a RR of 2.7 (1.6-4.4). Although the etiology of SP is unknown and probably of multifactorial origin, these data suggest that unusual changes in AP may play a relevant role in triggering this condition.

Adolescent↗

Targeted lipidomics using electron capture atmospheric pressure chemical ionization mass spectrometry.

There is an increasing need to be able to conduct quantitative lipidomics analyses as a complement to proteomics studies. The highest specificity for proteomics analysis can be obtained using methodology based on electrospray ionization (ESI) or atmospheric pressure chemical ionization (APCI) coupled with liquid chromatography/tandem mass spectrometry (LC/MS/MS). For lipidomics analysis it is often necessary to be able to separate enantiomers and regioisomers. This can be very challenging when using methodology based on conventional reversed-phase chromatography. Normal-phase chromatography using chiral columns can provide dramatic improvements in the resolution of enantiomers and regioisomers. However, conventional ESI- and APCI-MS/MS has limited sensitivity, which makes it difficult to conduct studies in cell culture systems where only trace amounts of non-esterified bioactive lipids are present. The use of electron capture APCI-MS/MS overcomes this problem. Enantiomers and regioisomers of diverse bioactive lipids can be quantified using stable isotope dilution methodology coupled with normal-phase chiral chromatography and electron capture APCI-MS/MS. This methodology has allowed a lipidomics profile from rat epithelial cells maintained in culture to be delineated and allowed the effect of a non-selective lipoxygenase inhibitor to be assessed.

Animals↗

Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions.

A self-aspirating heated nebulizer probe is described and demonstrated for use in the direct analysis of analytes on surfaces and in liquid samples by atmospheric pressure chemical ionization (APCI) mass spectrometry. Functionality and performance of the probe as a self-aspirating APCI source is demonstrated using reserpine and progesterone as test compounds. The utility of the probe to sample analytes directly from surfaces was demonstrated first by scanning development lanes of a reversed-phase thin-layer chromatography plate in which a three-component dye mixture, viz., Fat Red 7B, Solvent Green 3, and Solvent Blue 35, was spotted and the components were separated. Development lanes were scanned by the sampling probe operated under computer control (x, y plane) while full-scan mass spectra were recorded using a quadrupole ion trap mass spectrometer. In addition, the ability to sample the surface of pharmaceutical tablets (viz., Extra Strength Tylenol and Evista tablets) and to detect the active ingredients (acetaminophen and raloxifene, respectively) selectively was demonstrated using tandem mass spectrometry (MS/MS). Finally, the capability to sample analyte solutions from the wells of a 384-well microtiter plate and to perform quantitative analyses using MS/MS detection was illustrated with cotinine standards spiked with cotinine-d3 as an internal standard.

Atmospheric Pressure↗

Identification of very long chain unsaturated fatty acids from Ximenia oil by atmospheric pressure chemical ionization liquid chromatography-mass spectroscopy.

A method is described for the enrichment of very long chain unsaturated fatty acids from total fatty acids of Ximenia oil and their identification as picolinyl esters by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS/APCI). The method is based on the use of preparative reversed phase HPLC and their subsequent identification by microbore LC-MS/APCI. The combination of these two techniques was used to identify unusual unsaturated VLCFAs up to tetracontenoic acid. All four positional isomers of tetratriacontenoic acid were also synthesized to unambiguously confirm their structure.

Atmospheric Pressure↗

Determination of polycyclic aromatic hydrocarbons and polycylic aromatic sulfur heterocycles by high-performance liquid chromatography with fluorescence and atmospheric pressure chemical ionization mass spectrometry detection in seawater and sediment samples.

Two methods for determining 10 polycyclic aromatic compounds were developed. Both methods were based on high-performance liquid chromatography (HPLC), but one method used fluorescence detection, while the other used atmospheric pressure chemical ionization mass spectrometry (APCI-MS). For water analysis, solid-phase extraction (SPE) was on-line coupled to the separation system. Using a styrene-divinylbenzene copolymer (PLRP-s) as sorbent in the SPE and adding 20% of acetonitrile to the water sample before its preconcentration, recoveries were above 70% for most of the compounds. For the fluorescence method, all compounds were detected and six of them could be quantified at concentrations higher than 0.02 microg 1(-1). For the MS detection method, only seven of the compounds were detected and six were quantified at concentrations higher than 0.06 microg 1(-1). To analyse sediment samples, an extraction with dichloromethane was used and, due to the complexity of the matrix, a standard addition calibration was carried out. Seawater and sediment samples taken from the Tarragona fishing port and marina on the coast of Catalonia (Spain) were analysed, and five compounds (benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, benzo[ghi]perylene and indeno[1,2,3-cd]pyrene) were quantified in the sediment samples.

Atmospheric Pressure↗

Identification of very long chain fatty acids from sugar cane wax by atmospheric pressure chemical ionization liquid chromatography-mass spectroscopy.

A method is described for the enrichment of very long chain fatty acids (VLCFAs) from total fatty acids of sugar cane wax and their identification as picolinyl esters by means of liquid chromatography-mass spectrometry with atmospheric pressure chemical ionization (LC-MS/APCI). The method is based on the use of preparative reversed phase HPLC of 100 mg amounts and their subsequent identification by microbore APCI LC-MS. The combination of these two techniques was used to identify unusual saturated VLCFAs up to C(50).

Atmospheric Pressure↗

Liquid chromatography with atmospheric pressure chemical ionization and electrospray ionization mass spectrometry of flavonoids with triple-quadrupole and ion-trap instruments.

With 15 flavonoids as test compounds, the analytical performance of four modes of LC-MS, multiple MS (MSn) and tandem MS operation (atmospheric pressure chemical ionization (APCI), electrospray ionization, positive and negative ionization) was compared for two mass spectrometers, a triple-quadrupole and an ion-trap instrument. Two organic modifiers, methanol and acetonitrile, and two buffers, ammonium acetate and ammonium formate, were used. In general, the use of APCI in the negative ion mode gave the best response, with the signal intensities and the mass-spectral characteristics not differing significantly between the two instruments. The best results were obtained when methanol-ammonium formate (pH 4.0) was used as LC eluent. Under optimum conditions full-scan limits of detection of 0.1-30 mg/l were achieved in the negative APCI mode. Here it needs to be emphasized that up to 2-order response differences were found both between analytes and between modes of ionization. This implies that one should be very cautious when interpreting data on the screening of real-life samples. The main fragmentations observed in the MSn spectra on the ion-trap, or the tandem MS spectra on the triple-quadrupole were generally the same. The advantage of the former approach is the added possibility to ascertain precursor-->product ion relationships.

Atmospheric Pressure↗