PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Digital subtraction angiography for noninvasive imaging of the renal artery.

Digital subtraction angiography (DSA) is a relatively new radiologic technique for noninvasive imaging of arterial anatomy. DSA has been shown to be effective in defining the renal arteries in patients with known or suspected renovascular disease. DSA is an excellent means of screening for renovascular disease and of following patients with serial studies after surgical revascularization or percutaneous dilatation of renal arterial stenosis. It is excellent for monitoring patients with known renovascular disease.

Angiography↗

[Coronary hemodynamics in vasospastic angina: quantitative analysis by digital subtraction angiography].

To evaluate the coronary circulation and myocardial perfusion dynamics, we performed left coronary digital subtraction angiography (DSA) in 35 patients with vasospastic angina. The left coronary circulation time (CCT) measured from the proximal left coronary artery to the coronary sinus was 5.77 +/- 0.86 sec, and the left epicardial conducting artery transmission time (CAT) measured from the proximal left coronary artery to the apical area was 2.65 +/- 0.82 sec in normal controls. The CCT and CAT were significantly prolonged in patients with vasospastic angina, indicating that the coronary peripheral vascular resistance is probably greater after the cessation of nitrates and Ca(++)-antagonists. After the intracoronary injection of ergonovine malate, the CCT was slightly shortened, but the apical T1/2 was significantly prolonged in patients with vasospastic angina. This suggested that coronary vasospasm is present not only in the epicardial arteries but also in coronary arteries with peripheral resistance. These phenomena were not observed in normal controls. We performed left coronary DSA after conventional left coronary cineangiography. When the CCT exceeded 6.7 sec, we considered that the coronary circulation was significantly impaired. We concluded that the coronary DSA is very useful for evaluating abnormal coronary circulation in patients with vasospastic angina during myocardial perfusion.

Angina Pectoris↗

[Cost-effectiveness of and morbidity from digital subtraction angiography. A study of 5,817 cases].

This study was based on 5,817 patients examined by digital subtraction angiography (DSA) between 1984 and 1990. 5,209 patients received an intravenous injection of contrast agent and 608 received an intra-arterial injection. Digital subtraction angiography has become a routine procedure for the diagnosis of vascular disease in the various fields studied, as it provides images of diagnostic quality in 97% of cases: diagnostic quality of 95% after intravenous injection and 99% after intra-arterial injection. The morbidity is 1.65% for the intravenous route and 4.8% for the intra-arterial route. The morbidity of brachial artery catheterization is 5.5% DSA by intravenous injection is a low-risk angiographic technique which represents a major economy in terms of the cost of the examination and the examination time, a reduction of hospital stay and waiting lists; these advantages are very important in the current context of public health.

Adolescent↗

[Quality criteria of digital subtraction angiography of the trunk of the body].

The presently valid quality criteria of digital subtraction angiography in the body trunk area are described. The indications for intravenous and intraarterial examinations are explained; these are closely connected with the respective demands. The problem levels are analysed and update technical and methodical solutions are offered.

Angiography, Digital Subtraction↗

Carbon dioxide digital subtraction angiography: expanding applications and technical evolution.

Although several noninvasive techniques now exist for vascular imaging, including MR imaging, three-dimensional CT, and color-flow and duplex sonography, the gold standard to which these techniques are compared remains catheter angiography. Cut-film and digital subtraction angiography (DSA) using iodinated contrast material are the standard methods by which vascular imaging is performed. However, despite the development of low-osmolar contrast agents, premedication regimens, and careful patient selection, adverse reactions to contrast material, including idiosyncratic reactions and contrast-induced nephropathy, continue to occur in a small number of patients [1-3]. Carbon dioxide (CO2) was developed as an alternative to iodinated contrast material to avoid these problems [4]. Once the behavior of intravascular gas, the methods of safe delivery, and the principles of successful imaging are understood, the use of CO2 as an intravascular contrast agent during DSA allows accurate imaging with little risk. Recent advances in delivery systems, postprocessing capabilities, and its extension to new vascular interventional procedures have greatly expanded the usefulness of CO2 angiography in both diagnostic and interventional vascular radiology.

Angiography, Digital Subtraction↗

Noninvasive detection of steno-occlusive disease of the supra-aortic arteries with three-dimensional contrast-enhanced magnetic resonance angiography: a prospective, intra-individual comparative analysis with digital subtraction angiography.

BACKGROUND AND PURPOSE: Concomitant disease of the supra-aortic arteries can influence the outcome of surgical treatment of carotid artery stenosis. However, sensitivity and specificity data of noninvasive contrast-enhanced 3-dimensional (3D) magnetic resonance angiography (CE MRA) for the detection of steno-occlusive disease of the entire supra-aortic arteries including the circle of Willis remain unclear. We aimed to intra-individually compare high-spatial-resolution CE 3D MRA and digital subtraction angiography (DSA) for the assessment of steno-occlusive vascular disease of the supra-aortic arteries. METHODS: CE MRA and DSA of the supra-aortic arteries were prospectively performed in 50 consecutive patients. Intra-individual comparison of CE MRA and DSA was available in 833 arteries. High-spatial-resolution CE MRA comprised a measured voxel size of 0.81 mm x 0.81 mm x 1 mm (0.66 mm3). Steno-occlusive vascular disease of the 833 arteries was assessed independently by 2 radiologists according to the NASCET criteria. RESULTS: CE MRA had a sensitivity of 100% (73/73), a specificity of 99.3% (760/765), a positive predictive value of 93.6% (73/78), and a negative predictive value of 100% (760/760) by using a 70% to 99% threshold of arterial diameter stenosis. For detection of occlusion, sensitivity, specificity, PPV, and NPV value of CE MRA were 100%, respectively. CONCLUSIONS: Noninvasive high-spatial-resolution CE MRA is suited to replace diagnostic DSA for the detection of steno-occlusive disease of the supra-aortic arteries.

Adult↗

Digital subtraction angiography in the preoperative diagnosis of congenital heart disease.

From December of 1986 through February of 1990, digital subtraction angiography was performed on 156 patients, and specific diagnoses of congenital heart disease were made on the basis of information gathered by this imaging technique, supplemented by the physical examination. No other imaging techniques were used, for this was a prospective study designed to determine the accuracy of digital subtraction angiography alone in the diagnosis of congenital heart disease. When 80 of these 156 patients underwent subsequent operation, 75 were shown to have been diagnosed correctly, for an accuracy rate of 93.75%. Two patients died, for a mortality rate of 2.5%. The diagnostic value of digital subtraction angiography is discussed, as well as the compensative management of its artifacts.

Journal Article↗

The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: clinical results.

This new digital fluorography processing method of matched filtering generates a set of images that have been acquired at continuous video-frame rates (30 per second) over the temporal extent of the bolus (10 seconds), and it combines them to produce the equivalent of a single digital subtraction angiography (DSA) image. Because of the extensive temporal averaging used, the method can provide substantial x-ray exposure reduction per run as compared with conventional techniques for an equivalent signal-to-noise ratio in the final image. The matched filtering technique was compared with conventional pulsed (one per second) DSA images of both extracranial and intracranial arteries, and the results are presented. Matched filtered images provided image quality that was equivalent to that of conventional DSA images at about one-fourth the patient exposure per run for both carotid artery and cerebral vessel studies. Despite long integration times, patient motion irretrievably corrupted image quality in only two of five carotid artery studies and in none of three intracranial studies. Compensation for patient motion is demonstrated, and additional applications and limitations of the technique are discussed.

Angiography↗

[Digital subtraction angiography for the assessment of myocardial perfusion].

Coronary angiography does not only permit to evaluate the severity of coronary disease but also to assess coronary flow reserve in various myocardial perfusion areas by digital processing. Use of colour flow mapping allows the assessment of both, density as well as distribution velocity of contrast-medium (= parametric imaging). The advantage of this technique is given by the possibility to assess coronary flow reserve not only at rest but also under physiologic situations such as bicycle ergometry. Clinical investigations have shown that coronary flow reserve determined after papaverine administration does not correlate with physiologic conditions such as physical exercise.

Angiography, Digital Subtraction↗

Value of color duplex sonography for evaluation of tibioperoneal arteries in patients with femoropopliteal obstruction: a prospective comparison with anterograde intraarterial digital subtraction angiography.

PURPOSE: This study investigated the accuracy of color duplex sonography (CDS) compared with anterograde intraarterial digital subtraction angiography in the evaluation of the tibioperoneal arteries in patients with peripheral arterial occlusive disease. METHODS: Fifty consecutive patients with femoropopliteal obstruction were examined immediately before planned percutaneous transluminal angioplasty. All CDS examinations were performed by one observer; the angiograms were interpreted independently by two readers (A1, A2). We compared agreement concerning judgement of the dominant crural artery (suitable for an eventual femorocrural bypass operation) and judgement of the severity of arterial lesions. RESULTS: Concerning judgement of the dominant artery, the interobserver agreement between the two readers of the angiograms was better (kappa value, 0.76) than the agreement between CDS versus A1 (0.61) and CDS versus A2 (0.56). However, the differences were not statistically significant. The results were independent (no significant differences in the kappa values) of the following criteria: presence of diabetes; clinical stage of peripheral arterial occlusive disease; kind of femoropopliteal obstruction; and status of the popliteal artery. Concerning the evaluation of the severity of arterial lesions, the kappa values were significantly higher (p < 0.05) for A1 versus A2 (posterior tibial, 0.87; anterior tibial, 0.79; peroneal, 0.52) than for CDS versus A1 (0.51; 0.46; 0.07) and CDS versus A2 (0.35; 0.38; -0.05). The sensitivity of CDS (vs A1 as reference) for detecting a hemodynamically relevant arterial lesion (stenosis or occlusion) was 100% in the posterior tibial artery, 78% in the anterior tibial artery, and 92% in the peroneal artery. CONCLUSION: Compared with intraarterial anterograde digital subtraction angiography, the value of CDS-with its currently used technology-for evaluation of the dominant lower leg artery suitable for an eventual femorocrural bypass operation in patients who have femoropopliteal obstruction is limited. It cannot replace an accurate preoperative angiogram for the routine clinical practice, and its use should be restricted to special cases (such as patients with a history of severe allergic reaction to contrast media or of severely impaired kidney function). CDS is also limited in the accurate judgement of the morphologic features of the runoff arteries in their full length in patients with peripheral arterial occlusive disease.

Aged↗

The use of digital subtraction angiography in evaluating pulmonary abnormalities in children.

In nine cases of pulmonary lesions in children, the diagnostic procedure of digital subtraction angiography was used with minimal invasiveness. Vascular anatomy was additionally confirmed by angiocardiography in four cases. One patient had a thoracotomy with removal of a nonvascular mass, whereas the other four patients, based on information provided by the digital subtraction angiogram, continued to be followed clinically. Using a peripheral vein for injection, intravenous subtraction angiography proved to be a satisfactory method of evaluating pulmonary vascular lesions and provided considerable information. Although other imaging modalities, including angiocardiography, computerized axial tomography scanning, or radionuclide studies, may be necessary for confirmation of the diagnosis, digital subtraction angiography should be considered in the work-up of pulmonary abnormalities in the pediatric patient. Five of the nine case studies are presented as appropriate examples.

Journal Article↗

Virtual angioscopy using 3-dimensional rotational digital subtraction angiography for endovascular assessment.

PURPOSE: To investigate the feasibility of 3-dimensional rotational digital subtraction angiography (3D DSA) and the creation of virtual angioscopic images from its data before and after endovascular treatment. TECHNIQUE: Data sets from 3D DSA studies were used to create intraluminal images simulating angioscopy for 36 patients with arterial stenosis, aneurysm, or endoleak after stent-graft deployment. A biplanar DSA unit was used to acquire rotational angiography data, which was then processed with a surface-rendering technique to create maximum intensity projections, shaded surface displays, multiplanar reconstructions, and virtual angioscopy. 3D reconstructions were created in 2 minutes after angiography and provided realistic views adequate for vessel measurement, morphology assessment, and endoleak evaluation. CONCLUSIONS: 3D DSA and virtual angioscopy are novel techniques that have been successful in recreating images of blood vessels immediately after angiography. These techniques could be useful as additional imaging modalities to complement computed tomography or magnetic resonance imaging in the evaluation of vascular diseases after endovascular therapy.

Angiography, Digital Subtraction↗

Multidetector CT angiography of peripheral vascular disease: a prospective comparison with intraarterial digital subtraction angiography.

OBJECTIVE: The purpose of this study was to determine the accuracy of CT angiography using a multidetector scanner in the evaluation of patients with peripheral vascular disease. SUBJECTS AND METHODS: Eighteen patients with peripheral vascular disease who were referred for elective digital subtraction angiography (DSA) also underwent CT angiography. We scanned patients from the level of the superior mesenteric artery to the pedal arteries in a single helical scan. CT angiograms were produced using maximum-intensity-projection reconstructions. Findings were graded according to six categories: 1, normal (0% stenosis); 2, mild (1-49% stenosis); 3, moderate (50-74% stenosis); 4, severe (75-99% stenosis); 5, occluded; and 6, nondiagnostic. CT angiography findings were compared with DSA findings for each arterial segment. RESULTS: We found agreement for the degree of stenosis in 77.7% of the arteries and discrepancy for 22.3% of the arteries when all categories were considered. Grouping the six categories according to the threshold for treatment (categories 1 and 2 as one group and categories 3, 4, and 5 as the second group) resulted in an agreement of 91.95%. Compared with DSA, CT angiography yielded a sensitivity of 90.9% and a specificity of 92.4%. CONCLUSION: Multidetector CT angiography is an accurate, noninvasive technique for the imaging of peripheral vascular disease.

Aged↗

Relationship between the pixel value in digital subtraction angiography and iodine concentration: study in high iodine concentration with original phantom.

Quantitative digital subtraction angiography (DSA) image analysis based on densitometry is widely accepted and used. For the densitometoric DSA image analysis, it is required that there is a linear relationships between the pixel values on DSA images (DSA values) and contrast medium iodine concentration or the thickness of the vessels or the chambers filled with contrast material. We studied on relationship between the DSA value and iodine concentration especially in high iodine concentration. As for the relationship between DSA values and iodine concentration on the DSA images at low concentration, DSA phantom had a good linear relationship. However, the relationship at the high iodine concentration, DSA phantom sometimes lost this linear relationship. Our results suggested that it was necessary to identify relationship between DSA values and iodine concentration in each DSA system, especially in high iodine concentration setting, for densitometoric DSA image analysis.

Angiography↗