PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Biocompatibility”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Characterization and biocompatibility of organogels based on L-alanine for parenteral drug delivery implants.

The development of simple and efficient drug delivery systems for the sustained release of peptides/proteins and low molecular weight hydrophilic molecules is an ongoing challenge. The purpose of this work was to prepare and characterize novel biodegradable in situ-forming implants obtained via the self-assembly of L-alanine derivatives in pharmaceutical oils. Six different amphiphilic organogelators based on L-alanine were synthesized. These derivatives could successfully gel various vegetable and synthetic oils approved for parenteral administration. Gelation was thermoreversible, and phase transition temperatures depended on gelator structure, concentration and solvent. Hydrogen bonds and van der Waals interactions were shown to be the main forces implicated in network formation. Selected formulations were then injected subcutaneously in rats for preliminary assessment of biocompatibility. Histopathological analysis of the surrounding tissues revealed mild, chronic inflammation and an overall good biocompatibility profile of the implants over the 8 wk evaluation period. This study demonstrates that in situ-forming organogels represent a potentially promising platform for sustained drug delivery.

Alanine↗

Biocompatibility of cluster-assembled nanostructured TiO2 with primary and cancer cells.

We have characterized the biocompatibility of nanostructured TiO2 films produced by the deposition of a supersonic beam of TiOx clusters. Physical analysis shows that these films possess, at the nanoscale, a granularity and porosity mimicking those of typical extracellular matrix structures and adsorption properties that could allow surface functionalization with different macromolecules such as DNA, proteins, and peptides. To explore the biocompatibility of this novel nanostructured surface, different cancer and primary cells were analyzed in terms of morphological appearance (by bright field microscopy and immunofluorescence) and growth properties, with the aim to evaluate cluster-assembled TiO2 films as substrates for cell-based and tissue-based applications. Our results strongly suggest that this new biomaterial supports normal growth and adhesion of primary and cancer cells with no need for coating with ECM proteins; we thus propose this new material as an optimal substrate for different applications in cell-based assays, biosensors or microfabricated medical devices.

Adsorption↗

Biocompatibility evaluation of silk fibroin with peripheral nerve tissues and cells in vitro.

Silk-based materials have been used in the field of bone or ligament tissue engineering. In order to explore the feasibility of using purified silk fibroin to construct artificial nerve grafts, it is necessary to evaluate the biocompatibility of silk fibroin material with peripheral nerve tissues and cells. We cultured rat dorsal root ganglia (DRG) on the substrate made up of silk fibroin fibers and observed the cell outgrowth from DRG during culture by using light and electron microscopy coupled with immunocytochemistry. On the other hand, we cultured Schwann cells from rat sciatic nerves in the silk fibroin extract fluid and examined the changes of Schwann cells after different times of culture. The results of light microscopy, MTT test and cell cycle analysis showed that Schwann cells cultured in the silk fibroin extract fluid showed no significant difference in their morphology, cell viability and proliferation as compared to that in plain L15 medium. Furthermore, no significant difference was found in expression of the factors secreted by Schwann cells, such as nerve growth factor (NGF), brain-derived neurotrophic factor (BDNF) and S-100, between Schwann cells cultured in the silk fibroin extraction fluid and in plain L15 medium by the aid of immunocytochemistry, RT-PCR and Western analysis. Collectively, these data indicate that silk fibroin has good biocompatibility with DRG and is also beneficial to the survival of Schwann cells without exerting any significant cytotoxic effects on their phenotype or functions, thus providing an experimental foundation for the development of silk fibroin as a candidate material for nerve tissue engineering applications.

Animals↗

Biocompatible, nanogold-particle fluorescence enhancer for fluorophore mediated, optical immunosensor.

Fluorophores have been used as effective signal mediators for detecting biomarkers in biosamples. The enhancement of the fluorescence can, therefore, improve the sensitivity of fluorophore-mediated biosensors. A nanogold particle (NGP), when placed at an appropriate distance from a fluorophore, can effectively enhance the fluorescence by transferring the free electrons of the fluorophore, normally used for self-quenching, to the strong surface plasmon polariton field (SPPF) of the NGP. We found that some organic solvents can also enhance the fluorescence significantly. To maximize the fluorescence enhancement, novel, biocompatible nanogold particle reagents (NGPRs) were developed by combining NGPs and biocompatible solvents and tested. The level of enhancement by NGPRs was found to be additively contributed by two enhancers. These NGPRs were able to increase the signal of a fiber-optic biosensor as much as 10 times and accurately quantify some of the important cardiac markers at a tens of picomolar level. These novel enhancers are expected to be effective for fluorophore-mediated bioimaging as well as biosensing.

Biocompatible Materials↗

Investigation into potential mechanisms promoting biocompatibility of polymeric biomaterials containing the phosphorylcholine moiety. A physicochemical and biological study.

Phosphorylcholine (PC) moieties were chemically attached to surfaces of polymer microparticles by addition of 2-methylacryloyloxyethyl phosphorylcholine monomer to the seeded, semi-continuous polymerisations of methyl methacrylate (MMA) and butyl acrylate (BA). The surface of the bio-functionalised polymer microparticles was principally characterised using X-ray photoelectron spectroscopy (XPS), dynamic nuclear magnetic resonance (NMR) spectroscopy, scanning electron microscopy (SEM), photon correlation spectroscopy (PCS), acoustophoresis and enzyme-linked immunosorbent assays (ELISA). It was found that the persulphate initiating species are concealed behind the phosphorylcholine containing monomer sequence located on the surface of the microparticles. The combination of analytical techniques showed that the surfaces of the polymer microparticles are extremely mobile above the glass transition temperature of the co-polymer and able to rearrange depending on the environment in which they are placed. This allows the phosphorylcholine moiety to be preferentially expressed at the surface in aqueous media, but not so in the dry state or conditions of ultra-high vacuum. In terms of the nature of the biocompatibility of phosphorylcholine containing polymers, no evidence was found for the irreversible structuring of water molecules around the phosphorylcholine moiety in the wet state. The results of this work suggest that a more likely contributory reason for the protein-resistant nature of phosphorylcholine containing polymers is the mobility of the phosphorylcholine moiety. Increases in biocompatibility correspond with increases in the hydrophilicity of a polymer surface when phosphorylcholine is preferentially expressed. A large free water fraction may be present in the phosphorylcholine containing monomer sequence, as part of a hydrogel structure located at the surface of the polymer microparticles. This, coupled with concomitant modification of the local electrical double-layer very close to the surface may also play a critical role in reducing protein-surface interactions.

Biocompatible Materials↗

Synthesis of biocompatible hydrophobic silica-gelatin nano-hybrid by sol-gel process.

Silica-biopolymer hybrid has been synthesised using colloidal silica as the precursor for silica and gelatin as the biopolymer counterpart. The surface modification of the hybrid material has been done with methyltrimethoxysilane leading to the formation of biocompatible hydrophobic silica-gelatin hybrid. Here we are reporting hydrophobic silica-gelatin hybrid and coating precursor for the first time. The hybrid gel has been evaluated for chemical modification, thermal degradation, hydrophobicity, particle size, transparency under the UV-visible region and morphology. FTIR spectroscopy has been used to verify the presence of CH(3) groups which introduce hydrophobicity to the SiO2-MTMS-gelatin hybrids. The hydrophobic property has also been tailored by varying the concentration of methyltrimethoxysilane. Contact angle by Wilhelmy plate method of transparent hydrophobic silica-gelatin coatings has been found to be as high as approximately 95 degrees . Oxidation of the organic group which induces the hydrophobic character occurs at 530 degrees C which indicates that the surface hydrophobicity is retained up to that temperature. Optical transmittance of SiO2-MTMS-gelatin hybrid coatings on glass substrates has been found to be close to 100% which will enable the hybrid for possible optical applications and also for preparation of transparent biocompatible hydrophobic coatings on biological substrates such as leather.

Coated Materials, Biocompatible↗

Biodegradation and biocompatibility of contraceptive-steroid-loaded poly (DL-lactide-co-glycolide) injectable microspheres: in vitro and in vivo study.

PURPOSE: A controlled-release drug delivery of contraceptive steroids levonorgestrel (LNG) and ethinyl estradiol (EE) has been developed by successful encapsulation of LNG and EE in poly (lactide-co-glycolide) (PLG) microspheres. MATERIALS AND METHODS: Smooth, spherical, steroid-loaded PLG microspheres with a mean size of 10-25 microm were prepared by using the water/oil/water double-emulsion solvent evaporation method. RESULTS: In vitro release profiles showed an increased burst release of LNG/EE on Week 1; thereafter, the release was sustained. At the end of Week 7, the release of LNG/EE from 1:5 and 1:10 PLG microspheres was 75.64% and 62.55%. respectively. In vitro degradation studies showed that the PLG microspheres maintained surface integrity up to Week 8 and then eroded completely by Week 20. In an in vivo study, the serum concentration of LNG/EE in rats showed a triphasic release response, with an initial burst release of 8 ng/mL LNG and 14 pg/mL EE on Day 1; thereafter, a controlled release of the drugs to the systemic circulation was maintained until Week 15, maintaining constant drug levels of 2 ng/mL LNG and 3-4 pg/mL EE in the blood. Histological examination of steroid-loaded PLG microspheres injected intramuscularly into the thigh muscle of Wistar rats showed minimal inflammatory reaction, demonstrating that contraceptive-steroid-loaded microspheres were biocompatible. CONCLUSION: This controlled-release and biocompatible nature of the PLG microspheres may have potential application in contraceptive therapy.

Absorbable Implants↗

Improving the initial biocompatibility of a titanium surface using an Er,Cr:YSGG laser-powered hydrokinetic system.

OBJECTIVES: This study was designed to improve the initial biocompatibility of titanium (Ti) using an Er,Cr:YSGG-powered hydrokinetic system. METHODS: The Er,Cr:YSGG-powered hydrokinetic system with different laser energy densities, 125 and 190 J/cm(2), were applied to the Ti substrate. Human osteosarcoma U2-OS cells were used. The difference in the attached cell number between 3- and 1-days cell culture was calculated and defined as the initial cell proliferation index (CPI). The initial CPI was statistically analyzed using one-way analysis of variance with the factor of applied laser energy density. The surface spreading morphology of the attached cells after 1 day incubation was observed using a field-emission scanning electron microscope. RESULTS: The Er,Cr:YSGG laser-treated Ti had a higher (1.2-1.3 times) initial CPI (P<0.001) and better cell spreading morphology than the untreated Ti. Treating the Ti with higher Er,Cr:YSGG laser energy did not significantly improve the CPI and cell spreading morphology. SIGNIFICANCE: The initial biocompatibility of the Ti surface could be improved using an Er,Cr:YSGG laser-powered hydrokinetic system.

Analysis of Variance↗

In vitro release of insulin and biocompatibility of in situ forming gel systems.

The purpose of this study was to develop single-dose insulin delivery system based on in situ forming gel to provide basal insulin level for a prolonged period. The in situ forming gel formulation was prepared by dissolving poly(d,l-lactic acid) (PLA) in hydrophobic (benzyl benzoate) and hydrophilic (benzyl alcohol) solvent mixtures. In vitro release was carried out in phosphate buffered saline (PBS) (pH 7.4) and the amount of released insulin was quantified by MicroBCA assay. In vivo biocompatibility study of in situ forming gel system was based on the histological evaluation of the tissue samples retrieved from injection sites at different time points. The tissue reaction was evaluated over 12 weeks. Throughout this period, all formulations showed normal inflammatory and foreign body reactions characterized by the presence of macrophages, fibroblasts and foreign body giant cells. Neither necrosis nor tissue damage could be identified. At the end of 12 weeks, no distinct histological differences were observed in comparison to the control tissue samples. The comparable results between blank and insulin-loaded in situ forming gel system indicated that the insulin itself did not induce additional inflammatory reactions. The results suggested that in situ forming gel system was biocompatible.

Absorbable Implants↗

Biocompatibility and erosion behavior of implants made of triglycerides and blends with cholesterol and phospholipids.

Triglycerides are a promising class of material for the parenteral delivery of drugs and have become the focus of tremendous research efforts in recent years. The aim of this study was to investigate the biocompatibility of glyceroltripalmitate as well as the influence of cholesterol and distearoyl-phosphatidyl-choline (DSPC) on the erosion behavior of the lipid. For these investigations, two in vivo studies were carried out, in which cylindrical matrices of 2 mm diameter were manufactured and subcutaneously implanted in immunocompetent NMRI-mice. After excision of the implants, tissue reactions of the animals as well as changes in the weight, shape and microstructure of the implants were investigated. The triglyceride and cholesterol showed good biocompatibility, as indicated by their minimal encapsulation in connective tissue and the absence of inflammatory reactions. Increasing the levels of phospholipid in the implants, however, led to an increased inflammatory reaction. In contrast to cholesterol, which did not affect erosion, the incorporation of DSPC into the triglyceride matrices led to clearly visible signs of degradation.

Animals↗

Synthesis and characterization of biocompatible poly(organophosphazenes) aiming for local delivery of protein drugs.

Biocompatible and thermosensitive poly(organophosphazenes) with a lower critical solution temperature (LCST) below body temperature have been designed with the aim for the local delivery of peptide and protein drugs. These polymers could be synthesized by introducing short chain tri- or tetraethylene glycol as a hydrophilic group and a dipeptide, GlyGluEt2 as a hydrophobic group into the polyphosphazene backbone. The local tolerance tests using rabbits have shown that our polymers are biocompatible. Using the amphiphilic properties of these polymers, in vitro studies were performed for loading and releasing of a human growth hormone (hGH) as a model drug. The entrapment efficiency (%) of hGH by the polymer decreased as its polymer concentration increased, but exhibited high efficiency of more than 95% even at 20% hGH concentration in the polymer. The entrapped hGH has shown to be controlled releasing for 3-4 days.

Animals↗

In vivo biocompatibility and biodegradation of poly(ethylene carbonate).

Biodegradation and biocompatibility of poly(ethylene carbonate) (PEC) was examined using an in vivo cage implant system. Exudate analysis showed that PEC and PEC degradation products were biocompatible and induced minimal inflammatory and wound healing responses. Adherent foreign body giant cells (FBGCs) caused pitting on the PEC surface, which led to extensive degradation over time. Data obtained from molecular weight and examination of film cross-sections in the scanning electron microscope (SEM) indicated that PEC underwent surface erosion with no change to the remaining bulk. Attenuated total reflectance infrared (ATR-FTIR) spectroscopy was used to characterize the chemical degradation. Superoxide anion released from inflammatory cells appeared to initiate an "unzipping" mechanism of degradation by deprotonation of PEC hydroxyl end groups. The resulting alkoxide ion participated in a concerted mechanism involving water and the carbonate carbonyl, leading to elimination of ethylene glycol. Carbonate ions decomposed further with release of carbon dioxide to regenerate alkoxide ion.

Absorbable Implants↗

Novel biocompatible phosphorylcholine-based self-assembled nanoparticles for drug delivery.

Major challenges associated with nano-sized drug delivery systems include removal from systemic circulation by phagocytic cells and controlling appropriate drug release at target sites. 2-methacryloyloxyethyl phosphorylcholine (MPC) has been copolymerised in turn with two pH responsive comonomers (2-(diethylamino)ethyl methacrylate (DEA) and 2-(diisopropylamino)ethyl methacrylate (DPA), to develop novel biocompatible drug delivery vehicles. Micelles were prepared from a series of copolymers with varying block compositions and their colloidal stability and dimensions were assessed over a range of solution pH using photon correlation spectroscopy. The drug loading capacities of these micelles were evaluated using Orange OT dye as a model compound. The cytotoxicity of the micelles was assessed using an in vitro assay. The MPC-DEA diblock copolymers formed micelles at around pH 8 and longer DEA block lengths allowed higher drug loadings. However, these micelles were not stable at physiological pH. In contrast, MPC-DPA diblock copolymers formed micelles of circa 30 nm diameter at physiological pH. In vitro assays indicated that these MPC-DPA diblock copolymers had negligible cytotoxicities. Thus novel non-toxic biocompatible micelles of appropriate size and good colloidal stability with pH-modulated drug uptake and release can be readily produced using MPC-DPA diblock copolymers.

Biocompatible Materials↗

An ex vivo method for evaluating the biocompatibility of neural electrodes in rat brain slice cultures.

Failure of neural recording electrodes implanted in the brain is often attributed to the formation of glial scars around the implant. A leading cause of scar formation is the electrode material. Described below is an approach to evaluate the biocompatibility of novel electrode materials in a representative three-dimensional model. The model, brain slice culture, accounts for the response of the neural tissue in the absence of the systemic response. While limitations of any in vitro model exist, brain slice culture provides an indication of the response of neurons and glia in an environment more indicative of the in vivo environment than two-dimensional cell culture of glia or neurons alone. Polybenzylcyclobutene (BCB) electrodes were developed as test materials for flexible electrodes due to ease of processing, low water uptake, and inherent flexibility when formed in thin sheets. Biocompatibilty of the BCB neural electrodes was evaluated using living brain slices derived from the hippocampal regions of 100 g CD rats. Importantly, fewer animals can be used in brain slice culture to evaluate the neural tissue response than when using live animals, since several slices can be obtained per animal. Cellular response to the electrodes was evaluated at 0, 7, and 14 days. At all time points living cells, both neurons and glia, were observed in the vicinity of the electrode. In addition, cells were observed migrating out from the brain slices onto the shank of the BCB electrode. Brain slice culture is shown to be a viable alternative to in vivo evaluation, in that the response of both neurons and glia can be evaluated in a native three-dimensional state, while sacrificing fewer animals. Future in vivo evaluation with BCB will provide definitive answers on the degree of glial scarring in response to this new and biocompatible electrode material.

Animals↗

Comparison of the intraosseous biocompatibility of AH Plus, EndoREZ, and Epiphany root canal sealers.

To evaluate the intraosseous biocompatibility of AH Plus, EndoREZ, and Epiphany root canal sealers as recommended by the Technical Report #9 of the Fédération Dentaire Internationale (FDI). Thirty guinea pigs, 10 for each material, divided into experimental periods of 4 and 12 weeks, received one implant on each side of the lower jaw symphysis. At the end of the observation periods, the animals were killed and the specimens prepared for routine histological examination. After analyzing both periods, the inflammatory tissue reaction to EndoREZ was considered severe. In the AH Plus group, the reaction changed from severe to moderate, while it was observed biological compatibility to Epiphany with bone formation and none to slight inflammatory reaction. It was concluded that Epiphany root canal sealer was the only material that presented intraosseous biocompatibility within the two analyzed periods.

Animals↗

Biocompatibility of a silicone-coated polypropylene hollow fiber oxygenator in an in vitro model.

BACKGROUND: A silicone-coated microporous hollow-fiber membrane oxygenator has been developed to prevent plasma leakage during long-term use. The objective of this study was to evaluate the biocompatibility of the oxygenator. METHODS: A silicone-coated oxygenator was compared with an uncoated oxygenator in an in vitro model of cardiopulmonary bypass. Simulated circulation was maintained for 6 h at 37 degrees C. RESULTS: Platelet counts decreased significantly (p < 0.05) and leukocyte counts tended to decline; however, the differences between groups were not significant. Concentrations of C3a increased significantly in both groups (p < 0.05), but levels were significantly less in the silicone-coated oxygenator (p = 0.008). In contrast, concentrations of C4a, beta-thromboglobulin, and granulocyte elastase increased significantly (p < 0.05), but the differences between groups were not significant. CONCLUSIONS: Silicone coating over a microporous hollow-fiber membrane may improve biocompatibility by reducing C3a activation.

Coated Materials, Biocompatible↗

Biocompatibility of silicone-coated oxygenator in cardiopulmonary bypass.

BACKGROUND: This study was designed to analyze the biocompatibility of silicone-coated oxygenators using inflammatory response as the outcome measure, and to investigate whether the silicone-coated oxygenators perform better in terms of postoperative organ dysfunction. METHODS: The 32 patients who underwent cardiopulmonary bypass (CPB) were divided into 3 groups: group A (n = 10), heparin-coated circuit with silicone-coated oxygenator; group B (n = 11), whole heparin-coated circuit; and group C (n = 11), whole untreated circuit. The plasma concentrations of the proinflammatory markers, made of inflammatory cytokines (tumor necrosis factor-alpha, interleukin-1beta, interleukin-6, interleukin-8), terminal complement complex (C5b-9), and polymorphonuclear elastase (PMN-E), were measured by enzyme-linked immunosorbant assay. RESULTS: All proinflammatory markers were significantly lower in groups A and B than in group C, especially C5b-9 and PMN-E concentrations, which were significantly lower in group A than in group B. The alveolar-arterial oxygen gradients (A-aDO2) and the respiratory index were significantly better in group A than in group C. In group B, however, only the A-aDO2 was significantly better than in group C. The duration of intubation and the length of stay in the intensive care unit stay were significantly shorter in groups A and B than in group C. CONCLUSIONS: Silicone-coated oxygenators are biocompatible and prevent postoperative organ dysfunction.

Anticoagulants↗

Lipid-sugar particles for intracranial drug delivery: safety and biocompatibility.

Controlled release of drugs to specific locales in the brain has engendered considerable interest. Here we evaluate the safety and biocompatibility of 6-microm diameter particles composed of dipalmitoylphosphatidylcholine and chondroitin sulfate A, when delivered into the cerebral parenchyma and ventricles, and in the case of intravascular injection. Some particles were loaded with fluorescein-labeled albumin to facilitate detection. Particles placed in medium with cultured murine primary cortical neurons did not increase cell death at concentrations as high as 4 mg/ml. When particles (100 microg in 2 microl) were placed stereotactically in the striatum and lateral ventricles, there was no histological evidence on hematoxylin-eosin stained sections of tissue injury outside of the needle track in any animal 3, 7, and 14 days after injection (n=6 each), and no inflammation. Ventricular size was not significantly different between animals given intraventricular injections of particles and albumin solution at those time points (n=4 each). Intracarotid injection of particles at concentrations of 0.2 and 1 mg/ml (n=4 each) did not affect relative cerebral blood flow, and there were no embolic events on histology. In one animal in the group injected with 5 mg/ml (n=3), there was a profound decrease in rCBF, with patchy emboli on histology. These novel biodegradable particles are biocompatible in and around the brain, and may be safe for intracranial sustained drug delivery either in the parenchyma or into the CSF.

1,2-Dipalmitoylphosphatidylcholine↗