PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROCARDIOGRAPHY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Thallium-201 myocardial perfusion imaging at rest and during exercise. Comparative sensitivity to electrocardiography in coronary artery disease.

The sensitivity of myocardial perfusion imaging (MPI) using thallium-201 injected both at rest and during peak exercise was compared to simultaneously recorded 12 lead electrocardiography (ECG) for the detection of transient ischemia in 20 normal subjects and 63 patients with coronary artery disease (CAD). No significant perfusion defects or ECG changes were seen on either the rest or exercise studies in any of the normal subjects. Fifty-six percent of patients with CAD developed new perfusion defects with exercise compared to 38% who developed ischemic ST-segment depression (P less than 0.02). However, when chest pain and/or ST depression were considered indices of ischemia, the sensitivity of exercise testing and thallium-201 MPI was similar. The increased sensitivity of MPI compared to ST-segment depression on the ECG was due to patients with baseline ECG abnormalities and those who failed to achieve 85% of predicted maximum heart rate with exercise. Analysis of the exercise results according to the extent of coronary artery disease revealed a progressive increase in both positive ECGs and MPI with the number of vessels involved. In patients with single vessel disease the MPI was more sensitive than the ECG (P less than 0.02). The combination of the rest and exercise ECG, MPI and chest pain during exercise failed to identify 11% of patients with CAD. Exercise thallium-201 MPI is a useful adjunct to conventional exercise testing particularly when evaluating patients with abnormal resting ECGs, those who develop ventricular conduction defects of arrhythmias during exercise, and those who fail to achieve their predicted heart rate because of fatigue or breathlessness.

Adult↗

Myocardial imaging with thallium-201 at rest and during exercise. Comparison with coronary arteriography and resting and stress electrocardiography.

Myocardial imaging with intravenous thallium-201 (201Tl) was performed at rest and following maximal treadmill exercise in 101 patients with suspected coronary artery disease. Results were interpreted from Polaroid scintiphotos by three independent observers with complete interobserver agreement in 79%. Of 25 patients with no or insignificant coronary artery disease (less than 50% diameter stenosis), one (4%) had a resting 201Tl image defect, one (4%) had an exercise 201Tl defect, none had an ECG Q wave, and four (16%) had exercise ST-segment depression. Among 76 patients with coronary artery disease (greater than or equal to 50% diameter stenosis), 58 (76%) had a defect on either the rest or exercise 201Tl image. The proportion of patients with an exercise image defect (50/76, 66%) was greater than the proportion with exercise ST depression alone (34/76, 45%; P less than 0.02). Overall, 69 of the 76 (91%) patients with coronary artery disease had either a positive rest or exercise myocardial image and/or a positive rest (ECG Q waves) or exercise (ST depression) electrocardiogram. This exceeded the proportion with only rest or exercise electrocardiographic abnormalities (50/76, 65%; P less than 0.001). We conclude that rest and exercise myocardial imaging with 201Tl is easily accomplished with readily available imaging equipment. The image data enhanced the diagnostic sensitivity of stress electrocardiography, and provided spatial identification of the abnormal segment(s) of myocardium.

Adult↗

Clinical significance of upsloping ST segments in exercise electrocardiography.

Conventional exercise electrocardiographic criteria usually involve patterns with a horizontal or downsloping ST segment. In the present study we present criteria based on upsloping ST segments and compared these criteria with the conventional criteria. Using upsloping ST-segment criteria, the amount of ST-segment depression at 80 msec after the end of the QRS complex is used as a parameter (ST criterion E, with a depression of 100 mV, and ST criterion F, with a depression of 200 mV). In the graded exercise test a bicycle ergometer was used. The ECG leads were CM5 and CC5. The results of exercise electrocardiography were compared with the findings from coronary arteriography. In 623 selected patients (565 males and 58 females), application of conventional ST criteria gave a sensitivity of 56% and a specificity of 94%; with application of the ST criteria E or F, sensitivity was 75% and specificity 90%. In the 58 females use of these new criteria resulted in a sensitivity of 76% and specificity of 88%. Ninety-three patients (15%) could be classified as positive exercise responders by the sole presence of an upsloping ST segment (type E or F). Sixty-eight percent of the patients with type E and 75% with type F had two- or three-vessel disease (coronary obstructions greater their or equal to 50%). We conclude that ST criteria based on upsloping ST segments significantly increase the diagnostic yield of the exercise ECG.

Coronary Angiography↗

The high-risk angina patient. Identification by clinical features, hospital course, electrocardiography and technetium-99m stannous pyrophosphate scintigraphy.

We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +/- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p less than 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p less than 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients.

Acute Disease↗

Prevalence and prognostic significance of exercise-induced silent myocardial ischemia detected by thallium scintigraphy and electrocardiography in asymptomatic volunteers.

Although a silent ischemic electrocardiographic response to treadmill exercise in clinically healthy populations is associated with an increased likelihood of future coronary events (i.e., angina pectoris, myocardial infarction, or cardiac death), such a response has a low predictive value for future events because of the low prevalence of disease in asymptomatic populations. To examine whether detection of reduced regional perfusion by thallium scintigraphy improved the predictive value of exercise-induced ST segment depression, we performed maximal treadmill exercise electrocardiography (ECG) and thallium scintigraphy (201Tl) in 407 asymptomatic volunteers 40-96 years of age (mean = 60) from the Baltimore Longitudinal Study on Aging. The prevalence of exercise-induced silent ischemia, defined by concordant ST segment depression and a thallium perfusion defect, increased more than sevenfold from 2% in the fifth and sixth decades to 15% in the ninth decade. Over a mean follow-up period of 4.6 years, cardiac events developed in 9.8% of subjects and consisted of 20 cases of new angina pectoris, 13 myocardial infarctions, and seven deaths. Events occurred in 7% of individuals with both negative 201Tl and ECG, 8% of those with either test positive, and 48% of those in whom both tests were positive (p less than 0.001). By proportional hazards analysis, age, hypertension, exercise duration, and a concordant positive ECG and 201Tl result were independent predictors of coronary events. Furthermore, those with positive ECG and 201Tl had a 3.6-fold relative risk for subsequent coronary events, independent of conventional risk factors.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Inhibition of dipyridamole-induced ischemia by antianginal therapy in humans. Correlation with exercise electrocardiography.

BACKGROUND: Dipyridamole echocardiography test (DET: two-dimensional echocardiographic monitoring with dipyridamole infusion up to 0.84 mg/kg in 10 minutes) is a useful tool for the noninvasive diagnosis of coronary artery disease. Aims of the present study were to assess the effects of antianginal drugs on dipyridamole-induced ischemia and to evaluate whether drug-induced changes in DET response may predict variations in exercise tolerance. METHODS AND RESULTS: Fifty-seven patients with angiographically assessed significant coronary artery disease (greater than 70% lumen reduction in at least one major coronary vessel) performed a DET and an exercise electrocardiography test (EET) in random order both off treatment and on antianginal drugs (beta-blockers, calcium antagonists and nitrates, alone or in various combinations). The criterion for DET positivity was a transient dyssynergy of contraction absent or of a lesser degree in the baseline examination. In DET, two parameters were evaluated: the dipyridamole time (i.e., the time from onset of dipyridamole infusion to obvious dyssynergy) and the wall motion score index. DET sensitivity was 91% off therapy and fell to 65% under therapy (p less than 0.01). In the 37 patients who had a positive DET both off and on therapy, the dipyridamole time increased from 6 +/- 3 (off therapy) to 8 +/- 3 minutes (on therapy) (p less than 0.01). The wall motion score index at peak dipyridamole went from 1.38 +/- 0.14 to 1.31 +/- 0.14 (p less than 0.01). EET and DET yielded concordant (positive versus negative) results in 41 of 57 (71%) patients off and in 35 of 57 (61%) on therapy (p = NS). In the subgroup of 38 patients with both positive DET and EET without treatment, the therapy-induced variations in exercise time were significantly correlated with the variations in dipyridamole time (r = 0.5; p less than 0.01), not with variations in wall motion score index (r = 0.3; p = NS). CONCLUSIONS: 1) Antianginal therapy can protect from dipyridamole-induced ischemia and 2) the therapy-induced changes in DET response parallel variations in exercise tolerance and might be useful for the objective, exercise-independent assessment of the therapy efficacy.

Adrenergic beta-Antagonists↗

Standards for analysis of ventricular late potentials using high-resolution or signal-averaged electrocardiography. A statement by a Task Force Committee of the European Society of Cardiology, the American Heart Association, and the American College of Cardiology.

Sufficient data are available to recommend the use of the high-resolution or signal-averaged electrocardiogram in patients recovering from myocardial infarction without bundle branch block to help determine their risk for developing sustained ventricular tachyarrhythmias. However, no data are available about the extent to which pharmacological or nonpharmacological interventions in patients with late potentials have an impact on the incidence of sudden cardiac death. Therefore, controlled, prospective studies are required before this issue can be resolved. As refinements in techniques evolve, it is anticipated that the clinical value of high-resolution or signal-averaged electrocardiography will continue to increase.

American Heart Association↗

Differences in electrophysiological substrate in patients with coronary artery disease and cardiac arrest or ventricular tachycardia. Insights from endocardial mapping and signal-averaged electrocardiography.

BACKGROUND: Many studies have combined patients with hemodynamically well-tolerated ventricular tachycardia (VT) and those with cardiac arrest (CA) as a single, homogenous group. Recent studies suggest that these two groups have different electrophysiological substrates and responses to therapy. Most of these studies, however, enrolled patients with a variety of cardiac diagnoses. METHODS AND RESULTS: We used signal-averaged electrocardiography (SAECG) and endocardial catheter mapping to define the electrophysiological substrate in patients with coronary artery disease and VT or CA and correlate the results of the two methods. We also examined the usefulness of SAECG in CA patients to differentiate those with inducible arrhythmias from those who are noninducible. VT patients were more likely to have had a prior myocardial infarction (p = 0.0005) and to have inducible arrhythmias (p = 0.0001) than were CA patients. The induced arrhythmias in patients who presented with VT was VT in more than 90% of cases, whereas in CA patients, polymorphic ventricular tachycardia (PMVT) accounted for one third of induced arrhythmias. Mean filtered QRS duration was longer (135 versus 120 msec) and the terminal QRS voltage was smaller (20 versus 34 microV) in VT than in CA patients (p less than 0.01). Sixty-three percent of CA patients and 87% of VT patients had abnormal SAECG (p = 0.001). VT patients had more extensive endocardial abnormalities and more abnormal (53% versus 40%, p = 0.002), fractionated (8% versus 3%, p = 0.02), late (17% versus 8%, p = 0.0003), and late abnormal or fractionated (14% versus 4%, p = 0.0001) sites than CA patients. VT patients had a greater duration of the longest electrogram (129 versus 109 msec, p = 0.0006) and total endocardial activation time (68 versus 54 msec, p = 0.009). Among CA patients, those with induced VT had more extensive substrate than did those with induced PMVT and were similar to VT patients with induced VT. Among CA patients, the trend for more patients with inducible VT (77%) or PMVT (55%) than noninducible patients (47%) to have an abnormal SAECG did not reach statistical significance (p = 0.14). The positive and negative predictive values of an abnormal SAECG were 77% and 44%, respectively. CONCLUSIONS: VT patients have more extensive endocardial substrate than CA patients, which translates into greater and more frequent SAECG abnormalities. Among CA patients, there are significant differences in substrate between patients with induced VT and those with induced PMVT. SAECG is not useful in differentiating CA patients who have inducible VT or PMVT from those who do not.

Coronary Disease↗

Detection and localization of prolonged epicardial electrograms with 64-lead body surface signal-averaged electrocardiography.

BACKGROUND: Prolonged, fractionated ventricular electrograms often are detectable after myocardial infarction and are a marker for an arrhythmia-prone state. QRS late potentials detected on the body surface with signal-averaged electrocardiography (SAECG) are thought to arise from the diseased tissue that generates prolonged ventricular electrograms and as such are also a marker for arrhythmias. A limitation of the current SAECG technique is that recordings are obtained from only three bipolar lead pairs. Because late potentials probably arise from multiple small sources in the heart, more extensive sampling of the body surface may contribute additional information to the SAECG: The present study investigates the additional sensitivity of SAECG using 64 body surface leads in detecting prolonged epicardial electrograms and examines its use in determining the epicardial location of prolonged electrograms. METHODS AND RESULTS: Dogs were studied before and 5-10 days after either lateral left ventricular (n = 13) or right ventricular (n = 8) myocardial infarction. Greater prolongation of signal-averaged QRS duration was detected with 64-lead SAECG (postinfarction QRS duration, 100.3 +/- 16.3 msec) than with three-lead SAECG (postinfarction QRS duration, 89.4 +/- 10.1, p = 0.0005). Nineteen of the 21 dogs (90%) had prolonged epicardial electrograms detected over the infarct. The correlation between epicardial electrogram duration and signal-averaged QRS duration calculated from individual leads was much better for 64-lead SAECG (r = 0.88, p less than 0.0001) than for three-lead SAECG (r = 0.53, p = 0.01), and the difference was most marked in cases with longer electrogram durations (more than 100 msec). Local late potential maxima on the thorax after lateral left ventricular infarction were located to the left and inferior compared with those after right ventricular infarction (p = 0.006). CONCLUSIONS: SAECG with more extensive recording from the body surface using 64 leads detects greater QRS prolongation than three-lead SAECG, and the longer QRS durations detected correspond to the duration of prolonged epicardial electrograms. Body surface location of late potentials corresponds to the epicardial location of the prolonged electrograms. This application of body surface mapping techniques to SAECG may permit more sensitive detection of arrhythmia-prone states and may aid in identifying arrhythmia sources.

Animals↗

The effect of Valsalva maneuver on P wave in 12-lead surface electrocardiography in patients with paroxysmal atrial fibrillation.

The previous studies relating to the effect of the Valsalva maneuver on P wave do not provide detailed information. In those studies, the parameters related to P wave duration during the release phase of the Valsalva maneuver were evaluated. The authors evaluated P wave amplitude as well as P wave duration during the strain phase of the Valsalva maneuver. Thirty-seven normal subjects and 36 patients with paroxysmal atrial fibrillation (PAF) were included in the study. Twelve-lead surface electrocardiography (ECG) was obtained from all the patients before and during the strain phase of the Valsalva maneuver. The authors evaluated the parameters related to both P wave duration and P wave amplitude. The highest P wave voltage was expressed as the P wave amplitude maximum (P amp max), the lowest P wave voltage as the P wave amplitude minimum (P amp min), and the P wave amplitude dispersion (P amp dispersion) as "the P amp max - the P amp min." Also, the maximum P wave duration was expressed as the P maximum (P max), the minimum P wave duration as the P minimum (P min), and the P wave dispersion as "the maximum P wave duration (P max) - the minimum P wave duration (P min)." All these parameters were measured before and during the strain phase of the Valsalva maneuver. P max, P dispersion, P amp max, and P amp dispersion were higher in patients with PAF compared to those of normal subjects before the Valsalva maneuver. In normal subjects, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly higher in the strain phase of the Valsalva maneuver than before (p<0.01, p<0.01, p<0.05, and p<0.05, respectively). In the patients with PAF, P max, P wave dispersion, P amp max, and P amp dispersion values were significantly lower during the strain phase of the Valsalva maneuver than before. In conclusion, in the patients with PAF, P wave parameters were decreased during the strain phase of the Valsalva maneuver, approaching to the normal levels.

Adult↗

Diagnostic uses of intraatrial electrocardiography.

Many tachyarrhythmias present difficult diagnostic problems. In patients with underlying cardiac disease, serious hemodynamic derangements can be the sequelae of uncontrolled or improperly treated arrhythmias. Our experience, illustrated by the case presentations, confirm that intraatrial electrocardiography is a safe and reliable technique for elaborating difficult tachyarrhythmias that are not conclusively diagnosed by noninvasive ECG techniques. Because misinterpretation of tachycardias can lead to incorrect therapeutic decisions, the minimal risk of such a procedure is far surpassed by the information obtained, which allows for correct diagnosis and aids in guiding effective therapy. Although careful, critical analysis of ECG and rhythm strips frequently allows a proper diagnosis, occasions often arise when the rhythm cannot be accurately defined. In such instances an intraatrial lead electrocardiogram can be utilized and is invariably of diagnostic aid in resolving the relationship of the P wave to the QRS complexes, which is usually the important key to a tachyarrhythmia diagnosis.

Aged↗

Delineation of premature P waves on four-dimensional electrocardiography, a new display of electrical forces by computer techniques.

This study investigated the feasibility of four-dimensional electrocardiography (4-D ECG), a new display in which the vector loop was rotated and scanned along a timed axis to overcome the shortcomings of vectorcardiography (VCG). The subjects consisted of 38 patients with premature atrial complexes and 30 controls. The orthogonal Frank electrocardiograms were rotated three-dimensionally according to the right-hand rectangular coordinate system and scanned along a timed axis. The P wave delineation score, signifying good agreement with the intraobserver and interobserver variability, was significantly higher in 4-D ECG than those in the orthogonal leads or those on the transverse and frontal projections (P < 0.001). The authors measured the premature P loop areas as viewed from 361 directions. P loop areas were best delineated when viewed from cranial directions of 42.6 +/- 34.0 degrees and from rightward directions of 11.3 +/- 30.7 degrees. Adequate cranial rotation followed by scanning along a timed axis will maximally delineate premature atrial signals and provide comprehensive visualization of electrical forces.

Atrial Premature Complexes↗

The design and preliminary evaluation of a home electrocardiography and blood pressure monitoring network.

A home electrocardiography (ECG) and blood pressure (BP) monitoring network was established in Beijing. The network consisted of three parts: (1) the home ECG and BP monitoring devices; (2) the monitoring centre at the hospital; and (3) the data communication network, for which we chose the public telephone network. The system was tested in our university hospital for two months with 30 patients and six normal volunteers. A preliminary evaluation by the users indicated that the system was acceptable in terms of its efficiency and effectiveness. This paper describes the system design, the preliminary testing procedure, and results.

Adult↗

The limited utility of electrocardiography variables used to predict arrhythmia in psychotropic drug overdose.

OBJECTIVE: The aim of the present study was to examine the relationship between serious arrhythmias in patients with psychotropic drug overdose and electrocardiography (ECG) findings that have been suggested previously to predict this complication. METHODS: Thirty-nine patients with serious arrhythmias (ventricular tachycardia, supraventricular tachycardia or cardiac arrest) after tricyclic antidepressant overdose or thioridazine overdose were compared with 117 controls with clinically significant overdose matched to each case for the drug ingested. These patients with psychotropic drug overdose had presented for treatment to the Department of Clinical Toxicology, Newcastle and to the Princess Alexandra Hospital, Brisbane. The heart rate, the QRS width, the QTc and QT intervals, the QT dispersion, and the R wave and R/S ratios in aVR on the initial ECGs were compared in cases and controls. RESULTS: The cases had taken dothiepin (16 patients), doxepin (six patients), thioridazine (five patients), amitriptyline (five patients), nortriptyline (three patients), imipramine (one patient) and a combination of dothiepin and thioridazine (three patients). In 20 of the 39 patients with arrhythmias, the arrhythmia had been a presumed ventricular tachycardia. Of the other 19 patients, 15 patients had a supraventricular tachycardia, two patients had cardiac arrests (one asystole, one without ECG monitoring) and two patients had insufficient data recorded to make classification of the arrhythmias possible. The QRS was >/= 100 ms in 82% of cases but also in 76% of controls. QRS >/= 160 ms had a sensitivity of only 13% and occurred in 2% of controls. QRS > 120 ms, QTc > 500 and the R/S ratio in aVR appeared to have a stronger association with the occurrence of arrhythmia: QRS > 120 ms (odds ratio [OR], 3.56; 95% confidence interval [CI], 1.46-8.68), QTc > 500 (OR, 3.07; 95% CI, 1.33-7.07), and R/S ratio in aVR > 0.7 (OR, 16; 95% CI, 3.47-74). Excluding thioridazine overdoses and performing the analysis for tricyclic antidepressant overdoses alone gave increased odds ratios for QRS > 120 ms (OR, 4.83; 95% CI, 1.73-13.5) and QTc > 500 (OR, 4.5; 95% CI, 1.56-13) but had little effect on that for the R/S ratio in aVR > 0.7 (OR, 14.5; 95% CI, 3.10-68). CONCLUSION: ECG measurements were generally weakly related to the occurrence of arrhythmia and should not be used as the sole criteria for risk assessment in tricyclic antidepressant overdose. The frequently recommended practice of using either QRS >/= 100 ms or QRS >/= 160 ms to predict arrhythmias is not supported by our study. R/S ratio in aVR > 0.7 was most strongly related to arrhythmia but had estimated positive and negative predictive values of only 41% and 95%, respectively. The use of these specific predictors in other drug overdoses is not recommended without specific studies.

Adolescent↗

Magnetic sense in the Japanese eel, Anguilla japonica, as determined by conditioning and electrocardiography.

Magnetosensitivity of the Japanese eel, Anguilla japonica, was examined by conditioning and electrocardiography. Marine eels, river eels and farmed eels were conditioned to an imposed magnetic field ranging from 12,663 nT to 192,473 nT parallel to the fish body, which was placed along the earth's west-east axis. Electrocardiograms were recorded with electrodes placed close to the fish body inside a PVC pipe shelter. After 10-40 conditioning runs, all the eels exhibited a significant conditioned response (i.e. slowing of the heart beat) to a 192,473 nT magnetic field and even to a 12,663 nT magnetic field, respectively equivalent to 5.92x and 0.38x the horizontal geomagnetic field (32,524 nT) at our laboratory. The west-east vector of the imposed magnetic field (12,663 nT) combined with that of the geomagnetic field and produced a horizontal resultant magnetic field of 21 degrees easterly. Therefore, Japanese eel are magnetosensitive whether they are at sea, in the river or in the farm. Results of the present study were compared with those of past studies that showed no magnetic sense in the American eel, Anguilla rostrata, and the European eel, Anguilla anguilla.

Anguilla↗

Clinical significance of blood brain natriuretic peptide level measurement in the detection of heart disease in untreated outpatients: comparison of electrocardiography, chest radiography and echocardiography.

The aim of present study was to compare the predictive characteristics and cost-benefit of measuring the concentration of blood brain natriuretic peptide (BNP), compared with electrocardiography (ECG), chest radiography and echocardiography, as a diagnostic test for heart disease. The study group comprised 130 untreated patients who had symptoms suggestive of heart disease. According to the results of additional examinations and follow-up checks, 86 patients were diagnosed as having heart disease and 44 patients were judged free of heart disease. Positive findings in each test suggestive of heart disease were checked in accordance with criteria, and the number of positive and negative cases for each test was calculated. The predictive characteristics, such as specificity, sensitivity, accuracy, positive and negative predictive values, of each test and the cost-benefit value were calculated and analyzed statistically. The sensitivity, specificity and accuracy of blood BNP and echocardiography were significantly greater than those of ECG and chest radiography. Echocardiography had a significantly lower cost-benefit value compared with measuring blood BNP concentration. Thus, the blood BNP concentration had significantly higher predictive characteristics than ECG and chest radiography, and a cost-benefit value significantly greater than that of echocardiography.

Aged↗

Effects of pravastatin on exercise electrocardiography test performance and cardiovascular mortality and morbidity in patients with hypercholesterolemia: Lipid Intervention Study in Kyoto.

The long-term effects of the 3-hydoxy-3-methyl-glutaryl coenzyme A reductase inhibitor, pravastatin, on exercise electrocardiography (ECG) test performance and cardiovascular mortality and morbidity were compared with those of conventional lipid-lowering drugs in hypercholesterolemic patients with no history of myocardial infarction or stroke. One thousand two hundred and seventeen patients were randomly assigned with mean serum cholesterol, triglyceride, high-density lipoprotein (HDL) cholesterol, and low-density lipoprotein (LDL) cholesterol levels of 6.98 +/- 0.91mmol/L, 2.08 +/- 1.87mmol/L, 1.38 +/- 0.44mmol/L, and 5.07 +/- 1.14 mmol/L, respectively, and received either pravastatin at a dose of 10-20mg/day (group P) or one of the conventional lipid-lowering drugs such as fibrates, nicotinic acid, and probucol (group C). The numbers of patients available for analysis in groups P and C were 305 and 278 at year 1, 261 and 216 at year 2, 206 and 184 at year 3, 159 and 122 at year 4, and 103 and 81 at year 5. Over the 3.2 year mean follow-up period, the reduction in serum LDL cholesterol levels was significantly greater (p<0.01) in group P (-24.3%) than in group C (-16.0%). Serum HDL cholesterol levels increased in group P (+11.6%), but decreased in group C (-0.3%) (p<0.01). There were no significant differences in the rate of patients who exhibited ischemic changes to exercise ECG test (ischemic responders) between the 2 groups. Coronary heart diseases (CHD) occurred in 6 patients in group P and 13 in group C; pravastatin significantly reduced CHD risk (reduction rate 0.369; 95% confidence interval 0.140-0.970; p<0.05). No significant differences existed between the treatment groups in terms of the number of strokes (group P, 6; group C, 7) or deaths unrelated to CHD (group P, 3; group C, 2). Although pravastatin did not improve the proportion of ischemic responders on exercise testing, it reduced CHD risk and serum LDL cholesterol levels more significantly than conventional lipid-lowering drugs without adversely affecting the risk of stroke and non-CHD death in hypercholesterolemic patients.

Adult↗

Electrocardiography subtraction method of detecting low-amplitude, high-frequency components (L-HFCs) within the QRS complex of patients with ventricular tachycardia.

A new method of extracting the low-amplitude and high-frequency components (L-HFCs) was developed and this study investigated its usefulness in 86 subjects: 28 normal subjects (group 1) and 58 patients with a previous myocardial infarction (MI). The patients were classified into 3 groups: group 2 with 38 patients without ventricular tachycardia (VT), group 3 with 13 patients with non-sustained VT, and group 4 with 7 patients with sustained VT. The new electrocardiography (ECG) subtraction method, using a mathematical filtering procedure, was used instead of conventional complex filtering. The continuous L-HFCs within the QRS complex were analyzed using a Z-lead recording. The duration of the continuous L-HFCs was significantly longer in group 4 than in groups 1 (p<0.0001), 2 (p<0.0001) or 3 (p<0.05) with all 3 filters. The ECG subtraction method is a powerful and useful new technique for identifying patients at risk for either sustained or non-sustained VT after MI, and overcomes several of the problems with the conventional signal-averaging method.

Adult↗