PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Error minimization”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Six methods for isolating high-density lipoprotein compared, with use of the reference method for quantifying cholesterol in serum.

Using 90 serum specimens, we compared six routine procedures for high-density lipoprotein (HDL) isolation to determine the biases, if any, of each. Use of the Reference Method for cholesterol (Duncan et al., Centers for Disease Control, Atlanta, GA) and automated dispensing equipment helped ensure the accuracy of the cholesterol measurements and minimized errors from sample and reagent manipulations. Regression analysis of the results showed significant differences between most HDL isolation methods, except for those involving precipitation with heparin-MnCl2 (1.0 mol/L) or polyethylene glycol 6000, which yielded comparable results with a slope close to one and a zero intercept. The dextran sulfate (Mr 500 000)-MgCl2 method had the largest proportional and constant bias with respect to those two methods. All the methods produced comparable results in the clinically important low HDL-cholesterol range (250 to 350 mg/L), but biases were significant at high concentrations. We conclude that these increased biases in the upper ranges of HDL-cholesterol concentrations are the result of increased heterogeneity of HDL and the different mechanisms involved in forming the insoluble complexes between lipoproteins and the various precipitation reagents.

Analysis of Variance↗

Quantitation of bovine immunoglobulins: comparison of single radial immunodiffusion, zinc sulfate turbidity, serum electrophoresis, and refractometer methods.

Laboratory methods designed to quantitate serum immunoglobulin were evaluated: single radial immunodiffusion, zinc sulfate turbidity, and serum electrophoresis. Estimation of immunoglobulin concentration in neonatle calves, using total protein measurements, was also evaluated. Single radial immunodiffusion proved useful for quantitation when either class or subclass information was needed. Zinc sulfate turbidity measurements gave accurate results for total immunoglobulin except when hemolysis was present in the sample. A correction factor for hemoglobin that will minimize errors resulting from hemolysis was presented. Serum electrophoresis was also found to be an accurate quantitation method. Large errors were encountered in attempting to estimate immunoglobulin on the basis of total protein.

Animals↗

Experience with the cumulative integral method for measurement of glomerular filtration rate.

The glomerular filtration rate (GFR) was estimated using (125)I-iothalamate by the cumulative integral method in 95 subjects - 16 normal subjects and 79 patients with suspected or proved renal disease. This method is accurate, simple to perform and theoretically sound. It minimizes errors due to transit time and bladder storage. The normal range of GFR was determined to be 71 +/- 10 (two standard deviations) ml/min/m(2). In 66 patients serum creatinine levels were compared with the GFR value expressed per square metre. For any given serum creatinine level there is a wide range of GFR values. A serum creatinine value in the normal range, i.e. between 0.7 and 1.3 mg/dl, cannot be used to predict the patient's GFR. The micro blood sampling technique makes this method particularly useful in infants.

Adult↗

[About the adjustment of filters and comparators for the automatic interval-analysis (author's transl)].

The selective effect produced by an analog filter followed by a comparator, is represented in the voltage-frequency-plane by a frequency-dependent threshold of sensitivity and a scatter-diagramm, which is characterising the signal. The variation of the threshold, caused by differentiation of the signal, is described. Following this model it is discussed, how deviations of real circuits and real signals from certain assumptions influence the formation of intervals and the interval-histogram. It is stated, which values of the parameters of adjustment should be set, on the one hand, in order to minimize errors of the interval-length and maximize frequencies of intervals in the pass-band and, on the other hand, to provide for the chance of separating from the histogram such intervals which are inevitably subject to bigger faults.--Other criteria of optimization are pointed out. Technically caused limitations for the variation of parameters are mentioned. The application of the model, which is valid for analog signals in general, is demonstrated by two examples from the automatic analysis of EEG.

Electroencephalography↗

Effect of evaporation from sample cups on urea nitrogen assay.

The effects of evaporation from sample cups for urea nitrogen assays were determined. Thirty replicate analyses were performed on each of five groups of pooled human serum subjected to controlled evaporation in our laboratory. We found a mean increase in urea nitrogen concentration of one percent per hour due to evaporation. We urge laboratory personnel to take the action necessary to minimize errors due to evaporation. Specimens should always be capped while awaiting analysis in the laboratory.

Blood Urea Nitrogen↗

DNA sequences from the str operon of Escherichia coli.

The str operon at 72 min on the Escherichia coli chromosome contains genes for ribosomal proteins (r-proteins) S12 (str or rpsL) and S7 (rpsG) and elongation factors G (fus) and Tu (tufA). The sequence of the entire S12 gene, the S12-S7 intercistronic region, and the beginning of the S7 gene is reported. Also, the sequence of the end of the S7 gene, the S7-G intercistronic region, and the beginning of the elongation fractor G gene is reported. The S12-S7 intercistronic region is 96 base pairs long, in contrast to other intercistronic regions in r-protein operons which have been found to vary from 3 to 66 base pairs. The S7-G intercistronic region is only 27 bases long, supporting the previous conclusion that r-protein and elongation factor genes are co-transcribed. A comparison of translation initiation sites of the S12 and S7 genes, and other examples of co-transcribed r-protein genes, reveals no obvious features that could account for equimolar synthesis of all r-proteins. The codon usage in the S12 and S7 genes follows the pattern observed in other r-protein genes; that is, there is a highly preferential usage of codons recognized by the most abundant of isoaccepting tRNA species. This pattern could reflect the cell's need for efficient translation or minimal errors, or both, in r-protein synthesis.

Amino Acid Sequence↗

Toward the development of a new aptitude selection test battery for air traffic control specialists.

In an effort to update and refine the selection battery for air traffic controllers, five experimental tests measuring aptitudes and skills considered important in air traffic work were administered to 1,828 newly selected air traffic control specialist (ATCS) trainess on their first day of training at the FAA Academy in Oklahoma City. The five experimental tests and the five tests presently used by the Office of Personnel Management (OPM) for selecting ATCS trainess were employed in an iterative stepwise regression (stepdown procedure). The tests that made a significant contribution in predicting Academy scores were then used to form a composite and the old test battery and the new battery were compared. The new composite demonstrated a statistically significant increase in the multiple correlation over the old test battery. Use of the new test battery could result in a savings to the FAA in terms of Academy attrition due to failures. It could also aid in upgrading the quality of ATCS selectees and aid in minimizing error in air traffic control work.

Aptitude Tests↗

Guidelines for point-of-care testing. Improving patient outcomes.

Whole-blood biosensors and point-of-care testing created a unique paradigm in medical diagnostics in the 1980s, when liver and heart transplant centers, as well as operating rooms and other critical care areas implemented whole-blood analysis to provide rapid test results in 2 to 5 minutes. Rising expectations, patient-focused hospitals, and managed care intensify the need for immediate decisions at the point of care. The guidelines promote consensus priorities, multidisciplinary teamwork, fiscal coordination, and collaborative practice during this phase of rapid change. Four primary principles and accompanying guideline objectives are optimization (patient outcomes, medical linkages, integrated diagnostic synthesis, therapeutic turnaround time, test clusters, and critical limits), hybridization (strategic modalities, economic effectiveness, and testing --> monitoring), quality (quality improvement, clinical performance, risk reduction and academics and accreditation), and consistency (results communication and error minimization, and reference intervals and standardization). Whole-blood analysis and point-of-care testing help facilitate temporal optimization, optimize diagnostic-therapeutic processes, and improve patient outcomes in critical care.

Blood Chemical Analysis↗

Individual differences in slow brain potentials in a guessing task.

18 healthy right-handed subjects had to predict one of two random non-equiprobable events by pressing one of two buttons with the right index finger. Each trial was preceded by a cue that increased the probability of the corresponding event in comparison to its overall probability. The Bereitschaftspotential (BP) before an action and the stimulus-preceding negativity (SPN) between the action and the event presentation were recorded. The subjects were subdivided into groups according to their tendency to follow the cue or to reject it. Cue rejection provided in the present situation a larger final gain than cue acceptance. Those subjects who used the former strategy were characterized by a local BP increase over the right parietal cortex, when a low-probable cue was presented. Their SPN amplitude was relatively small, but it increased substantially after a low-probable cue. Subjects who tended to follow the cue had a very large BP amplitude over the projection area and at vertex. Their SPN was overall large, regardless of condition. Peculiarities of the potentials recorded in these subjects are thought to relate to their desire to minimize errors.

Adolescent↗

Aspiration cytology of salivary gland lesions advantages and pitfalls.

FNAC of the major salivary glands was performed on 72 patients during a period of two and a half years. In 64 patients samples were satisfactory. The cytologic diagnosis was correlated with histology available in 36 cases. 21 out of 22 benign lesions and 12 out 4 malignant lesions were correctly identified rendering a diagnostic accuracy of 91 percent. The pitfalls of FNAC of salivary gland lesions are reflected by the overall false positive rate of 5.5 percent of false negative rate of 2.7 percent. Diagnostic pitfalls are due to variability of tumor morphology which makes sampling & interpretation difficult. Multiple sampling and increasing experience help to minimize errors.

Biopsy, Needle↗

Yale database for DNA sequence changes in mutagenesis.

The Yale database contains sequence changes in mutations induced in a number of bacterial, mammalian and yeast genes. It contains data in electronic form on more than 17,000 mutations (July, 1994), is periodically updated, and is available without cost on Internet and on diskettes. Researchers are invited to contribute additional results; a data entry program, MUSTIN, is provided to facilitate adding new data and to minimize errors.

Animals↗

Quantitative mapping of regional cerebral blood flow using iodine-123-IMP and SPECT.

UNLABELLED: A method was developed to calculate functional images of regional cerebral blood flow (rCBF) from a single scan using SPECT following intravenous 123I-N-isopropyl-p-iodoamphetamine (IMP) infusion. METHODS: A two-compartment model that includes two parameters of rCBF and regional distribution volume of IMP (Vd) was employed to correct for clearance of IMP from the brain. Using a given input function and a fixed Vd value (30 ml/ml according to an analysis on dynamic SPECT data), a unique value of rCBF was calculated for each pixel of the SPECT image according to the table-look-up procedure. This technique was applied to 15 human subjects, and the calculated rCBF values were compared with those measured by PET. RESULTS: A set of simulation studies demonstrated an optimal SPECT midscan time at 30 to 40 min postinjection of IMP, providing the minimal error sensitivity to the individual difference of the input function (rCBF values with an accuracy of +/- 10%). Another set of simulation suggested validity of fixing the Vd values, i.e., errors in calculated rCBF values were around +/- 7% for a change of Vd of +/- 10%. The measured rCBF values obtained from 15 human subjects were independent on the SPECT scan time. The calculated rCBF values also agreed well with those obtained by the nonlinear least-squares fitting analysis that were obtained from the dynamic SPECT scan and the frequent arterial blood sampling and measurement of lipophilic fraction for each sample (0.54 + 0.88x, r = 0.86), suggesting the validity of the simplified procedures in this method. CONCLUSION: These observations suggested the validity of this method as a clinical tool for quantitative measurement of rCBF.

Amphetamines↗

99mTc-DTPA scintillation-camera renography: a new method for estimation of single-kidney function.

A new method of combined serial scintigraphy and renography, using a scintillation camera and 99mTc-DTPA is evaluated. Renographic curves, corresponding to light-pen "areas of interest" over the renal parenchyma, were processed. "Blood-background" curves were recorded from an external detector over the temporal region of the head and also from an "area of interest" corresponding to the aorta and inferior vena cava. The uptake phase of the renogram was always linear. The sum of the slopes of the uptake phase of both kidneys correlated well with the measured glomerular filtration rate in 25 patients with renal insufficiency of various degrees. Single-kidney function estimated from the slopes correlated reasonably well with single-kidney function estimated from 131I-Hippuran renography with external detectors. The method described minimizes errors in the estimation of single-kidney function, and both anatomic and functional information is obtained.

Humans↗

Etiology of spondylolisthesis. Assessment of the role played by lumbar facet joint morphology.

This study examined the role of facet joint morphology in the etiology of both degenerative spondylolisthesis and isthmic spondylolysis. To this end, the axial facet joint morphology of the lower lumbar spine in a normal population and in populations of patients with spinal stenosis or degenerative spondylolisthesis at L4-5 and in patients with isthmic spondylolysis at the L5 level were characterized. Computed tomographic scans were digitized, defining the axial morphology of the normal facet joint at five stations from proximal to distal within the joint. Assessments were made of facet joint orientation, transverse articular dimension, depth of the articular surface, and shape of the articular surface at levels L3-4, L4-5, and L5-S1. There was a gradually more coronal orientation from proximal to distal among the stations at each level, and a maximal transverse articular dimension at the level of the superior endplate of the caudad vertebra. Minimal error in the recording process at this level. In addition to the maximal joint dimension, made this level the most representative of the overall morphology and most useful for further studies. At the L4-5 level, a significantly more sagittal facet orientation was found in the degenerative spondylolisthesis group when compared to both the normal population and spinal stenosis groups (P < 0.01). At L5-S1, the only significant morphologic difference between the normal population and the patients with isthmic spondylolysis was reduced transverse articular dimension. These results support the hypothesis that patients developing degenerative spondylolisthesis are predisposed to this by a developmental sagittal orientation of the L4-5 facet joints.

Adult↗

[Quantitation of regional myocardial blood flow using continuous inhalation of C15O2 and positron emission tomography].

A C15O2 continuous inhalation and a steady-state theory using positron emission tomography (PET) have been used to quantitate regional cerebral blood flow. We extended this method for quantitative regional myocardial blood flow (RMBF) measurement. Forty-three patients, involving 4 normal volunteers, 16 patients with coronary heart disease (CHD), 20 patients with hypertrophic cardiomyopathy (HCM), and 3 patients with dilated cardiomyopathy (DCM), were studied. 6 min-scan was recorded in the steady-state condition during C15O2 continuous inhalation. A C15O inhalation scan was required to obtain the blood pool image. The subtracted image showed myocardial perfusion image. These images demonstrated homogeneous accumulation in normal volunteers. Reduced accumulation were detected in patients with myocardial infarction. Hypertrophied myocardium was demonstrated in patients with HCM. Diffuse heterogeneous accumulation was demonstrated in patients with DCM. Fourteen patients with HCM, whose left ventricular myocardial thicknesses were more than 20 mm, were selected for the RMBF measurement to minimize errors due to the partial volume effect. The arterial blood activity was measured by assigning a region of interest to the left atrial cavity on PET images. RMBF was calculated using the steady-state theory. Calculated flow values ranged from 21.2 to 152.6 ml/min/100 g. The good correlation was obtained between RMBF using 13NH3 first pass method and RMBF using gas inhalation method in six patients. These results indicate that C15O2 PET has the potential capability for the noninvasive quantitation of RMBF.

Adult↗

Measurement of cardiovascular and renal function in unrestrained hamsters.

We describe a preparation for measuring blood pressure, left ventricular end diastolic pressure, heart rate, and renal excretory variables (volume, electrolytes, glomerular filtration rate) in hamsters. The new approach offers an advantage over previously described methods by eliminating the problems associated with restraint. Hamsters were surgically implanted with venous and arterial catheters. A specially constructed bladder catheter, which allows flushing to minimize errors due to dead space and permits urine collection without restraining the animals, was also implanted. The hamsters were allowed to recover from surgery for 3 hours before being studied in a specially designed lucite housing unit. Representative results were obtained in cardiomyopathic and healthy hamsters.

Animals↗

Comparison of endoscopic and surgical explorations for perilymphatic fistulas.

A history suggestive of perilymphatic fistula (PLF) often prompts repeated tympanostomies to establish a diagnosis and perform a repair. Two patients having multiple previous explorations for perilymphatic fistulas were reoperated, comparing endoscopic and open surgical methods. A third patient with a history consistent with PLF also underwent dual assessment. Endoscopic exploration of the middle ear was performed through a myringotomy and, immediately after, by elevation of a tympanotomy flap. The endoscopic examinations were thorough yet revealed no evidence of perilymphatic fistula; however, the surgical approaches revealed pooling in the oval windows consistent with perilymphatic fistula. These findings were video documented. Recurrent and primary fistulas may be the result of artifact, such as injected anesthetic agents and transudates introduced during surgical explorations, which may interfere with an accurate diagnosis of perilymphatic fistula. Endoscopy of the middle ear is recommended as one method to minimize errors in diagnosis.

Adult↗

[Adverse effects due to unstable blood products].

Most discussions of blood transfusion cover risks and side effects, while the daily benefits of donor systems and transfusion concepts for modern medicine are taken for granted. Even though in this report side effects are a major part of the content, we should be aware that today's component concept leads to a remarkable quality level of blood products. After a historical introduction we present a patient with transfusion transmitted anti-hepatitis A IgM antibodies and a delayed type hemolytic transfusion reaction induced by a boostered anti-Fyb alloantibody. This case demonstrates that the safety of transfusions depends on both the blood product and the patient's transfusion history. In the second part we summarize side effects from transfused blood products: (1) transmission of infectious diseases and the risk of blood products testing falsely negative, (2) immune mediated side effects, (3) immuno-modulations by blood transfusions, (4) side effects caused by human error. Minimizing transfusion risks is not only the task of the doctors specialized in transfusion medicine, but can only be achieved by close cooperation between all the persons associated with each step, from motivating unpaid blood donors, evaluation of donors, phlebotomy, viral testing, preparation of components, storage, and transportation conditions, to adequate indications and transfusions for the patients.

Aged↗