PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “FLUOROSCOPY”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

[CT fluoroscopy].

Percutaneous biopsy of pulmonary nodules requires precise needle placement, with the goal of attaining a secure position of the needle for therapeutic or diagnostic purposes as quickly as possible and with minimal tissue damage along the access route. The requirements from the image guidance system during the intervention are, in addition to universal applicability, a quick reaction time and a user-friendly interface. CT fluoroscopy fulfils these requirements, although radiation protection for the patient and radiologist becomes an important issue.

Biopsy, Needle↗

[Digital radiography und fluoroscopy. Basics of technology, imaging properties and applications].

For 110 years, x-rays and special x-ray films have been used in medical diagnostics. New developments in the field of x-ray techniques, and especially new computer applications, have led to new imaging techniques which have substantially expanded the spectrum of radiological examinations. In spite of significant technological and medical advances in the field of MRI and multidetector-CT, radiographic images of the lungs, skeleton and organs still comprise up to 80% of the routine radiological workload. The increasing availability of digital detectors has led to the continual replacement of conventional film/screen systems. The inclusion of digital mammography was delayed due to the higher requirements for spatial resolution. For about 2 years, dynamic flat panel detectors have started to replace the image intensifier which has been used in fluoroscopy for 40 years.

Biotechnology↗

Comparing the performance of mono- and biplane fluoroscopy systems in diagnostic and interventional neuroangiography using the dose-area product.

Biplane digital imaging systems are favoured in neurointerventional practice since they are believed to contribute to safer, quicker and more efficacious procedures. Our aim was to establish if such equipment exposes patients to the same level of ionising radiation as monoplane systems. We reviewed monoplane and biplane fluoroscopy screening times and dose-area products (DAP) for 267 diagnostic cerebral angiograms and 56 neurointerventional cases. Significantly lower DAP for the latter were recorded on the biplane equipment, demonstrating an important reduction in patient exposure to radiation. There were no significant differences between the two systems for diagnostic cerebral angiography.

Cerebral Angiography↗

Minimizing radiation injury and neoplastic effects during pediatric fluoroscopy: what should we know?

Radiation-induced injuries from fluoroscopic procedures in pediatric patients have occurred, and young patients are at greatest risk of many radiation-induced neoplasms. Some fluoroscopists have been injured from their use of fluoroscopy, and they are known to be at risk of radiation-induced neoplasm when radiation is not well-controlled. This article reviews the circumstances that lead to radiation injury and delineates some procedural methods to avoid injury and limit radiation exposure to both the patient and the fluoroscopist.

Body Burden↗

Fluoroscopy-guided retrieval of a sheared endotracheal stylet sheath from the tracheobronchial tree in a premature infant.

Endotracheal intubation of premature infants with respiratory distress is a commonly performed procedure in the neonatal intensive care unit. We report a rare complication of this procedure, shearing of the plastic sheath that is bonded to and surrounds the stylet used to assist intubation and lodging of the sheared stylet in the tracheobronchial tree of a small premature infant. We suggest a method for removing the plastic foreign body using fluoroscopy and an Amplatz gooseneck snare directed through the existing endotracheal tube, a technique not previously reported.

Alloys↗

CT fluoroscopy-guided abdominal interventions.

Computed tomographic fluoroscopy (CTF) is one of the most recent developments in helical computed tomography (CT), which is increasingly being used in interventional radiology. The method combines the advantages of CT with the real-time capabilities of ultrasonography. This article reviews the current clinical applications of CTF in the monitoring of abdominopelvic interventions with reference to published clinical studies.

Biopsy, Needle↗

First experiences in CT-guided percutaneous transhepatic biliary decompression by means of real-time CT fluoroscopy.

BACKGROUND: Computed tomographic fluoroscopy (CTF), also called real-time CT, is increasingly used in interventional radiology but has not yet been recommended to guide percutaneous transhepatic biliary decompression (PTBD). We report our early clinical experiences with CTF-guided PTBD. METHODS: Sixteen consecutive patients underwent PTBD under CTF guidance because of obstructive jaundice caused by malignant tumor (11 cases of carcinoma of the bile duct, four cases of pancreatic cancer, and one case of metastasis). CTF-guided PTBD was performed on a helical CT scanner and a surgical C arm. Main target parameters were the success and complication rates, the number of necessary punctures, the time needed for successful puncture of a suitable bile duct, and the patients' radiation exposure. RESULTS: CTF-guided punctures of the bile duct for PTBD were successful on the first trial in 10 cases; in six patients, two hits were necessary. The time needed to hit a suitable bile duct was 6-21 s (median = 13 s). Therefore, the radiation exposure (skin) was 27-94.5 mSv. The additional implantation and stenting of the bile duct by means of the surgical C arm was uneventful in 15 cases. In one case, only external drainage could be achieved. Complications did not occur. CONCLUSION: CTF enables good visualization of the most suitable duct for puncture. Therefore, subsequent recanalization seems to be easier than other methods.

Bile Duct Neoplasms↗

Percutaneous transhepatic catheterization of the portal vein: A combined CT- and fluoroscopy-guided technique.

Combined CT- and fluoroscopy-guided transhepatic portal vein catheterization was performed in 44 patients selected for pancreatic islet cell transplantation. The method allowed catheterization with a single puncture attempt in 39 patients. In four patients two attempts and in one patient four attempts were necessary. One minor hematoma of the liver capsule occurred that required no further treatment. Compared with other methods the average number of puncture attempts was reduced.

Adult↗

First experiences in percutaneous arterial chemoembolization of malignant liver lesions by means of real-time CT fluoroscopy.

Computed tomography fluoroscopy (CTF) allows real-time display (continuous imaging) and has been increasingly used in interventional procedures. We wished to demonstrate the usefulness of CTF in chemoembolization of the liver. Twenty-one patients with primary or secondary malignant lesions of the liver underwent CTF-guided chemoembolization after angiographic positioning of a catheter in the hepatic artery. Embolization materials such as Lipiodol and mitomycin C were administered under continuous CT scanning. CTF led to a change of the method (correction of catheter position, application of norepinephrine) in nine of 21 cases. There were no fatal complications.

Aged↗

Fluoroscopy-controlled voiding cystourethrography in infants and children: are the radiation risks trivial?

The purpose of this study was to determine the gonadal dose, effective dose and relevant radiogenic risks associated with pediatric patients undergoing voiding cystourethrography (VCUG). Exposure parameters were monitored in 118 consecutive children undergoing VCUG. The entrance surface dose (ESD) was determined by thermoluminescent dosimeters (TLDs). For male patients, the gonadal dose was determined by TLDs attached on the anterior scrotum. For female patients, the gonadal dose was estimated by converting ESD to the ovarian dose. ESD-to-ovarian dose conversion factors were determined by thermoluminescence dosimetry and physical anthropomorphic phantoms representing newborn and 1-, 5- and 10-year-old individuals. The effective dose was estimated by using ESD and data obtained from the literature. The mean fluoroscopy time and number of radiographs during VCUG were 0.73 min and 2.3 for female and 0.91 min and 3.0 for male pediatric patients, respectively. The gonadal dose range was 0.34-5.17 mGy in boys and 0.36-2.57 mGy in girls. The corresponding ranges of effective dosage were 0.12-1.67 mSv and 0.15-1.45 mSv. Mean radiation risks for genetic anomalies and carcinogenesis following VCUG during childhood were estimated to be up to 15 per million and 125 per million, respectively. Radiation risks associated with pediatric patients undergoing VCUG should not be disregarded if such a procedure is to be justified adequately.

Adolescent↗

Quality assurance programme applied to mobile C-arm fluoroscopy systems.

The importance of quality assurance (QA) of X-ray equipment in diagnostic imaging departments is well recognised. However, practically no attention has been paid in the literature to the application of QA programmes to mobile C-arm fluoroscopy systems. This equipment is sometimes omitted from these programmes because it is often "off-site" from the main radiological facility and suitable QA protocols are unavailable. The need for QA can be substantiated by the fact that these systems are finding greater clinical use in orthopaedic, vascular and cardiac applications. Hence, there is a growing awareness among users for the need of good image quality and low patient radiation dose. In view of this, the objective of this study was to review the existing literature, design a suitable QA protocol for this equipment and use it to survey 10 C-arms in clinical use. The protocol was designed to address mechanical and electrical safety in addition to radiation safety and image quality. Results indicate substantial performance differences between systems with significant variations in input air kerma rate to the image receptor. The authors believe that such a protocol is necessary with a view to establishing optimal performance levels and assist in the development of suitable "write-off" criteria for such systems.

Equipment Safety↗

Fluoroscopy-guided application of corticosteroids for local control of manubriosternal joint pain in patients with spondyloarthropathies.

Symptomatic manubriosternal arthritis, occasionally encountered with spondyloarthropathies, may not be adequately controlled by systemic therapy. Local corticosteroid injections make a potential contribution to symptomatic management. Three patients with acute inflammation of the joint as documented by MRI and fluoroscopy-guided therapy are presented. Topical treatment with triamcinolone acetonide (40 mg) was well tolerated and induced rapid and complete relief of pain for between 3 weeks and 3 months. In spite of the clinical improvement, the signs of inflammation in MRI did not decrease. Local steroid application seems to be an underused therapeutic modality in managing rheumatic involvement of the anterior chest wall.

Administration, Topical↗

Cardiac fluoroscopy for the diagnosis of coronary artery disease: a meta analytic review.

To evaluate variability in the reported accuracy of fluoroscopically detected coronary calcific deposits for predicting angiographic coronary disease, we applied meta analysis to 13 consecutively published reports comparing the results of cardiac fluoroscopy with coronary angiography. Population characteristics and technical and methodologic factors were analyzed. Sensitivity and specificity for predicting serious coronary disease compare quite well with those from the literature on the exercise ECG and the exercise thallium scintigram. Sensitivity increases and specificity decreases more significantly with patient age, and sensitivity is paradoxically lower in laboratories testing patients with more severe disease, as well as when 70% rather than 50% diameter narrowing is used to define angiographic disease. Work-up and test review bias were also significantly related to reported accuracy.

Age Factors↗

Computed tomography-guided coil injection and thoracoscopic pulmonary resection under roentgenographic fluoroscopy.

To remove a small, chest roentgenogram-negative, computed tomogram-positive nodule, we developed a novel technique of thoracoscopic pulmonary resection. This technique consists of the computed tomography-guided coil injection of a metallic coil and subsequent thoracoscopic resection under roentgenographic fluoroscopy. During the thoracoscopic resection, the fluoroscopic image was a valuable aid in determining the location of the nodule and in ensuring that the stapler was applied with a sufficient distance from the coil. Because this technique helps to determine the exact location of the nodule regardless of its depth from the pleural surface, even a minithoracotomy for direct palpation can be avoided.

Adenocarcinoma↗

Are hard-copy prints from peroperative fluoroscopy images useful as documentation?

We have examined the applicability of peroperative image documentation, in promoting early mobilization after osteosynthesis and saving the standard X-ray examination. One hundred and twenty-three patients with proximal femoral fractures were included in the investigation. Hard-copy reprints were recorded from peroperative fluoroscopy images by Fuji Film Thermal Imaging System FTI 200. These reprints were compared with the standard X-rays to assess the quality of the osteosynthesis and possible restriction in mobilization. The specificity of finding an unstable osteosynthesis was 0.40, whereas the sensitivity of finding a stable osteosynthesis was 0.96. In all, four unstable osteosyntheses were overlooked on the hard copy reprints. The specificity of finding patients in need of restricted mobilization was 0.44 and the sensitivity of finding patients allowed free mobilization was 0.93. Eight patients needing restricted mobilization were overlooked on the reprints. Hard-copy images do not safely reveal unstable osteosynthesis and cannot replace the standard X-rays taken postoperatively.

Fluoroscopy↗

Combined flexible endoscopy and fluoroscopy in the assessment of the gap between the two esophageal pouches in esophageal atresia without fistula.

The authors have used the technique of combined retrograde flexible endoscopy and fluoroscopy on two newborn babies with esophageal atresia (EA) without tracheoesophageal fistula (TEF). This technique accurately determined the gap between the two esophageal ends and predicted the feasibility and timing of delayed primary anastomosis. Esophagostomy was not performed, and continuous Replogle tube suction of the upper pouch was maintained during the period of waiting for 10 and 14 weeks, respectively. Gastrostomy feeding allowed satisfactory growth and development during the period of waiting for esophageal growth.

Anastomosis, Surgical↗