PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Polyhydroxyethyl Methacrylate”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Staining glycol methacrylate embedded cartilage with triethyl-carbocyanin DBTC ("ethyl-stains all") with special reference to the interlacunar network.

The dye, triethyl-carbocyanin DBTC, was tested for differential staining of cartilage structures. Femoral head articular cartilage from neonatal rats was processed for histology to demonstrate the interlacunar network. Sections of glycol methacrylate (GMA) embedded cartilage were stained at pH 2.8, 5.4, 6.1 and 8.0 to determine the optimal staining conditions. Only at pH 6.1 were all cartilage structures stained and the best contrast achieved. Streptomyces hyaluronidase, chondroitinase ABC, pepsin, trypsin, and pronase digestions were carried out prior to staining at pH 6.1 to evaluate the selectivity of the stain. Undigested chondrocyte nuclear chromatin stained dark purple; staining intensity was reduced slightly by pepsin or trypsin digestion. Undigested chondrocyte cytoplasm stained light blue but stained purple after hyaluronidase digestion. Undigested extracellular matrix stained light violet; staining was almost entirely eliminated by chondroitinase ABC digestion, was unaffected by hyaluronidase, and was either unaffected or increased after proteinase digestion. Staining of a narrow zone of matrix adjacent to the network was prevented by proteinase digestion while the network element appeared as a thin dark line. The network appears to be a trilaminar structure; a core element of hyaluronic acid and protein surrounded by a protein sheath. Triethyl-carbocyanin DBTC staining of cartilage offers slightly more selectivity and contrast than methylene blue, toluidine blue or safranin O. At pH 6.1, DNA, perhaps RNA, and hyaluronic acid stained deep purple; chondroitin sulfate, light violet; protein (collagen), stained very light violet if at all.

Animals↗

Clinical evaluation of HTR polymer bone replacement grafts in human mandibular Class II molar furcations.

A biocompatible microporous composite of PMMA (poly-methyl-methacrylate), PHEMA (poly-hydroxyl-ethyl-methacrylate), and calcium hydroxide (HTR) or autogenous osseous coagulum (AOC) bone replacement grafts were evaluated in 15 pairs of mandibular molar Class II furcations in 9 patients. Following initial preparation, full thickness flaps were raised to gain access to the furcations; mechanical hand and ultrasonic root and defect debridement and chemical (tetracycline) root preparation were performed; paired furcations in each patient were randomly grafted with either HTR or AOC; and the host flaps replaced or slightly coronally positioned. Weekly, then monthly, deplaquing was performed until surgical re-entry at 6 to 12 months. Both treatments improved the clinical status of the treated furcations. Direct clinical measurements demonstrated essentially equivalent clinical results with both bone replacement graft materials related to most hard and soft tissue changes in the furcations. Differences in favor of HTR were found for horizontal residual furcation depth (2.4 mm vs. 3.9 mm), horizontal furcation fill (1.9 mm vs. 0.8 mm), and percent horizontal furcation fill (44.4% vs. 17.1%) (all P < or = 0.05 paired t test). These favorable results with HTR polymer are similar to several reports with other graft materials and with GTR barriers, and suggest that HTR polymer may be a useful therapeutic adjunct in the clinical management of grade II mandibular molar furcations.

Adult↗

Studies of the slow releasing of testosterone from radiation-polymerized testicular prostheses implanted subcutaneously in the back of castrated rabbits.

A controlled release testicular prosthesis containing testosterone, which was previously dissolved in 2-hydroxyethyl methacrylate (HEMA) at a temperature of 80 degrees C, was prepared by radiation-induced polymerization in the supercooled state at a low temperature. The daily dose of testosterone released in vitro from the poly(HEMA) testicular prosthesis was kept constant at a rate of 5.5 +/- 1.5 mg/d throughout an experimental period of 900 d. In the in vivo experiments, the poly(HEMA) testicular prosthesis was implanted subcutaneously in the back of castrated rabbits over a maximum period of 11 mnth. The cumulative amounts of testosterone released in vitro and in vivo from the poly(HEMA) testicular prosthesis for a period of 11 mnth were found to be 2.1 g (30.0 wt% of initial drug) and 0.9 g (12.8 wt% of initial drug), respectively. The serum testosterone level in castrated rabbits with a poly(HEMA) testicular prosthesis rapidly decreased for periods up to 2 mnth (after increasing during the first 2 wk), then showed a moderate decrease for a few months, and finally held constant at a level of 10 ng/ml throughout the experimental period. It was concluded that a slight amount of testosterone is continuously released in vivo from the radiation-polymerized poly(HEMA) testicular prosthesis over a long period analogous with that in vitro.

Animals↗

Formulation optimization of photocrosslinked polyacrylic acid modified with 2-hydroxyethyl methacrylate hydrogel as an adhesive for a dermatological patch.

A photopolymerization technique was applied in the preparation of a hydrogel composed of polyacrylic acid (PAA) in which 2-hydroxyethyl methacrylate (HEMA) was modified. The formulation of photocrosslinked PAA modified with HEMA hydrogel as an adhesive for a dermatological patch was optimized based on the simultaneous optimization technique. Photocrosslinked PAA modified with HEMA hydrogels that retained a large amount of water, above 85%, were successfully prepared. Based on the analysis of ANOVA, the gel strength and adhesiveness increased with an increase in the degree of modification with HEMA and the concentration of PAA modified with HEMA in the aqueous solution. For the optimization study, the modification with HEMA and the concentration of initiator were selected as causal factors. Gel yield, probe tack, degree of swelling and turbidity were selected as response variables. A set of causal factors and response variables was used as a tutorial date for the prediction of optimal formulation with a quadratic regression model, an artificial neural network (ANN) and a multivariate spline interpolation (MSI). Response surfaces generated with MSI well represented the nonlinear relationship between the factors and the responses, and all the observed values of the response variables coincided with the predictions. A high functional photocrosslinked PAA modified with HEMA hydrogel as an adhesive for a dermatological patch was successfully created using the simultaneous optimization technique incorporating MSI.

Acrylic Resins↗

Preliminary results after implantation of four AlphaCor artificial corneas.

PURPOSE: The purpose was to evaluate the validity of implantation of the artificial cornea (AlphaCor) in human corneas considered too high risk for penetrating keratoplasty with donor tissue. METHODS: Four keratoprostheses, made from poly(2-hydroxyethyl methacrylate) (PHEMA) with a porous skirt and a transparent optical part, were implanted into the cornea of four patients. Keratocytes invading the skirt provide a watertight fixation with the scarred corneal tissue. Deep to the clear optical part, the posterior corneal lamella was excised to a diameter of 3.5 mm before the device was implanted, and the anterior lamella was trephined similarly 3 months after AlphaCor implantation. RESULTS: The eyes selected to receive an artificial cornea had significant neovascularisation, and 0-3 previous failed grafts. Follow-up for 6 months revealed best visual acuity between 20/400 and 20/50. Factors limiting the visual acuity outcome were optic atrophy and age-related macular disease. One patient underwent an extracapsular cataract extraction after the device was implanted, as a senile cataract was then noted. One complication occurred, a central corneal stromal melt, which was managed by covering with a 9-mm donor lamella. CONCLUSION: The flexible device AlphaCor may provide a substitute for donor corneal tissue in desperate cases. Advantages include the simple implantation technique, which avoids trauma to the surrounding structures. Visual acuity results may be limited by pre-existing pathology, but it appears that a patient's visual potential can be achieved. Further follow-up to exclude long-term complications is required.

Adult↗

Implantable controlled delivery systems for proteins based on collagen--pHEMA hydrogels.

Co-polymeric hydrogels of collagen and poly(hydroxyethyl methacrylate) (pHEMA) were prepared using an ammonium persulphate-sodium metabisulphite redox initiation technique. Fluorescein isothiocyanate (FITC)-labelled bovine serum albumin (BSA) was entrapped into these hydrogels. These gels were modified differently by external cross-linking and made highly porous by incorporation of ethylene glycol. The morphological characteristics of the gels containing FITC-BSA before and after release were studied. The in vitro release of FITC-labelled BSA was studied in phosphate buffer, pH 7.4, at 37 degrees C. The results clearly indicated that collagen-pHEMA hydrogels release FITC-BSA in a zero-order fashion. In the case of uncross-linked hydrogels, the release of FITC-BSA was about 81% within 8 d, compared to 49% for the same period in the case of cross-linked hydrogels. It was also observed that in the case of porous hydrogels the release was very fast (19% in the first hour) and lasted for about 12 h, releasing 76% of FITC-BSA. These results clearly indicated that collagen-pHEMA hydrogels released BSA in a zero-order fashion and that the release rate can be programmed by appropriate modification of the hydrogel matrices.

Animals↗

Synthetic hydrogel guidance channels facilitate regeneration of adult rat brainstem motor axons after complete spinal cord transection.

Synthetic guidance channels or tubes have been shown to promote axonal regeneration within the spinal cord from brainstem motor nuclei with the inclusion of agents such as matrices, cells, or growth factors to the tube. We examined the biocompatibility and regenerative capacity of synthetic hydrogel tubular devices that were composed of poly(2-hydroxyethyl methacrylate-co-methyl methacrylate) (PHEMA-MMA). Two PHEMA-MMA channels, having a mean elastic modulus of either 177 or 311 kPa were implanted into T8-transected spinal cords of adult Sprague Dawley rats. The cord stumps were inserted into the channels and fibrin glue was applied to the cord-channel interface. An expanded polytetrafluoroethylene (ePTFE) membrane was used for duraplasty. Controls underwent cord transection alone. Gross and microscopic examination of the spinal cords showed continuity of tissue within the synthetic guidance channels between the cord stumps at 4 and 8 weeks. There was a trend towards an increased area and width of bridging neural tissue in the 311-kPa guidance channels compared to the 177-kPa channels. Neurofilament stained axons were visualized within the bridging tissue, and serotonergic axons were found to enter the 311-kPa channel. Retrograde axonal tracing revealed regeneration of axons from reticular, vestibular, and raphe brainstem motor nuclei. For both channels, there was minimal scarring at the channel-cord interface, and less scarring at the channel-dura interface compared to that observed next to the ePTFE. The present study is the first to show that axons from brainstem motor nuclei regenerated in unfilled synthetic hydrogel guidance channels after complete spinal cord transection.

Animals↗

Non-connected versus interconnected macroporosity in poly(2-hydroxyethyl methacrylate) polymers. An X-ray microtomographic and histomorphometric study.

Poly(2-hydroxyethyl methacrylate) (pHEMA) has potentially broad biomedical applications: it is biocompatible and has a hardness comparable to bone when bulk polymerized. Porous biomaterials allow bone integration to be increased, especially when the pores are interconnected. In this study, three types of porogens (sugar fibers, sucrose crystals, and urea beads) have been used to prepare macroporous pHEMA. The pore volume and interconnectivity parameters of the porosity were measured by X-ray microtomography and image analysis. Sucrose crystals, having a high volumetric mass, gave large pores that were located on the block sides. Urea beads and sugar fibers provided pores with the same star volume (2.65 +/- 0.46 mm3 and 2.48 +/- 0.52 mm3, respectively) but which differed in interconnectivity index, fractal dimension, and Euler-Poincarés number. Urea beads caused non-connected porosity, while sugar fibers created a dense labyrinth within the polymer. Interconnectivity was proved by carrying out surface treatment of the pHEMA (carboxymethylation in water), followed by von Kossà staining, which detected the carboxylic groups. Carboxymethylated surfaces were observed on the sides of the blocks and on the opened or interconnected pores. The disconnected pores were unstained. Macroporous polymers can be prepared with water-soluble porogens. X-ray microtomography appears a useful tool to measure porosity and interconnectedness.

Biocompatible Materials↗

Biodegradability of poly (2-hydroxyethyl methacrylate) in the presence of the J774.2 macrophage cell line.

The degradation of cross-linked and linear poly(2-hydroxyethyl methacrylate) (pHEMA), was examined in vitro with J774.2 cells. pHEMA microbeads were prepared with both types of polymers. Only cells in contact with the microbeads increased their production of lysosomal enzymes (TRAcP and ANAE) and released large amounts of reactive oxygen species with both types of pHEMA microbeads. Electron microscopy showed that macrophages were able to erode the surface of linear pHEMA but unable to erode the surface of the cross-linked polymer. Cells appeared wrapped by the linear pHEMA surface, but those cultured on the cross-linked polymer were only laying at the surface. After cell culture, the surface roughness of pHEMA slices was observed by atomic force microscopy (AFM). There was a significant increase in roughness (R(a)) of the surface of linear pHEMA slices cultured with J774.2 cells whereas no difference in R(a) between the surface of cross-linked pHEMA slices could be measured. AFM image of the hydrated materials were done: the surface of linear pHEMA swelled considerably in saline whereas the hydrated cross-linked polymer did not differ from the air-dried appearance. In conclusion, linear pHEMA swells in biological fluids, activates macrophages in close contact with the polymer and can be progressively eroded.

Absorbable Implants↗

Correlation of histological findings with gadolinium enhanced MRI scans during healing of a PHEMA orbital implant in rabbits.

BACKGROUND/AIMS: To investigate a poly(2-hydroxyethyl methacrylate) (PHEMA) orbital implant with a spongy anterior hemisphere and a smooth gel posterior hemisphere, by histology correlated with magnetic resonance images. METHODS: Following enucleation, eight rabbits received PHEMA implants to which the muscles were directly sutured, and underwent gadolinium enhanced magnetic resonance imaging (MRI) from 3 to 52 weeks. After the rabbits were killed, the implants were removed, cut in a plane corresponding to the scan, and processed for light and electron microscopy. RESULTS: All eight rabbits retained their implant to the end of the study period without complications. The scans demonstrated muscle attachment to the anterior half of the implant, and enhancement was seen on injection of gadolinium chelate. Histology confirmed muscle attachment, and cellular and vascular ingrowth. Over time, a transformation from reactive inflammatory to relatively non-vascular scar tissue was seen within the implant. Calcium deposits in one implant were detected by imaging and histology. CONCLUSION: The implants are readily visualised on MRI. Muscle attachment and fibrovascular ingrowth into the anterior hemisphere are seen, while encapsulation of the posterior hemisphere is minimal. Histological findings confirm the progress of the healing response, with initial inflammation and marked vascularisation, developing later into quiescent scar tissue predominantly of fibroblasts.

Animals↗

Poly(hydroxyethyl methacrylate-co-methacrylamidoalanine) membranes and their utilization as metal-chelate affinity adsorbents for lysozyme adsorption.

Different adsorbents have been reported in the literature for protein purification. The authors have developed a novel and new approach to obtain high protein adsorption capacity utilizing a 2-methacrylamidoalanine-containing membrane. Amino acid ligand 2-methacrylamidoalanine (MAAL) monomer was synthesized using methacryloyl chloride and alanine. Poly(2-hydroxyethylmethacrylate-co-2-methacrylamidoalanine) [p(HEMA-co-MAAL)] membranes were then prepared by UV-initiated photopolymerization of HEMA and MAAL in the presence of an initiator (azobisisobutyronitrile, AIBN). The synthesized MAAL monomer was characterized by NMR. p(HEMA-co-MAAL) membranes were characterized by swelling studies, porosimeter, SEM, FTIR, and elemental analysis. These membranes have macropores in the size range of 5-10 microm. Cu(II) ions (25.9 mmol/m2) were chelated on these membranes. p(HEMA-co-MAAL) membranes were used to study the adsorption of lysozyme from aqueous media containing different amounts of lysozyme (0.1-3.0 mg/l) and at different pH values (4.0-8.0). The non-specific adsorption of lysozyme on the pHEMA membranes was negligible (0.9 microg/cm2). Incorporation of MAAL increased the lysozyme adsorption significantly up to 2.96 mg/cm2. The lysozyme adsorption capacity of the Cu(II) incorporated membranes (9.98 mg/cm2) was greater than that of the p(HEMA-co-MAAL) membranes. More than 90% of the adsorbed lysozyme was desorbed in 1 h in the desorption medium containing 1.0 M NaCl and 0.025 M EDTA. The metal-chelate affinity membranes are suitable for repeated use for more than ten cycles without a noticeable loss of capacity.

Adsorption↗

Molecular depth profiling of multilayer polymer films using time-of-flight secondary ion mass spectrometry.

The low penetration depth and high sputter rates obtained using polyatomic primary ions have facilitated their use for the molecular depth profiling of some spin-cast polymer films by secondary ion mass spectrometry (SIMS). In this study, dual-beam time-of-flight (TOF) SIMS (sputter ion, 5 keV SF(5)(+); analysis ion, 10 keV Ar(+)) was used to depth profile spin-cast multilayers of poly(methyl methacrylate) (PMMA), poly(2-hydroxyethyl methacrylate) (PHEMA), and trifluoroacetic anhydride-derivatized poly(2-hydroxyethyl methacrylate) (TFAA-PHEMA) on silicon substrates. Characteristic positive and negative secondary ions were monitored as a function of depth using SF(5)(+) primary ion doses necessary to sputter through the polymer layer and uncover the silicon substrate (>5 x10(14) ions/cm(2)). The sputter rates of the polymers in the multilayers were typically less than for corresponding single-layer films, and the order of the polymers in the multilayer affected the sputter rates of the polymers. Multilayer samples with PHEMA as the outermost layer resulted in lowered sputter rates for the underlying polymer layer due to increased ion-induced damage accumulation rates in PHEMA. Additionally, the presence of a PMMA or PHEMA overlayer significantly decreased the sputter rate of TFAA-PHEMA underlayers due to ion-induced damage accumulation in the overlayer. Typical interface widths between adjacent polymer layers were 10-15 nm for bilayer films and increased with depth to approximately 35 nm for the trilayer films. The increase in interface width and observations using optical microscopy showed the formation of sputter-induced surface roughness during the depth profiles of the trilayer polymer films. This study shows that polyatomic primary ions can be used for the molecular depth profiling of some multilayer polymer films and presents new opportunities for the analysis of thin organic films using TOF-SIMS.

Acetic Anhydrides↗

Retinoic acid restores shape-dependent growth control in neoplastic cells cultured on poly(2-hydroxyethyl methacrylate)-coated substrate.

The ability of retinoic acid to modulate cell-shape-dependent growth of untransformed (human skin fibroblasts and mouse embryo Swiss 3T3 fibroblasts) and neoplastic cells (human cervical carcinoma HeLa-S3, osteosarcoma Hs791, and murine melanomas B16-F1, S91-C2 and S91-C154) was examined. The cells were plated on tissue culture dishes coated with increasing concentrations of poly(2-hydroxyethyl methacrylate), poly(HEMA) which cause a gradual decrease in substrate adhesiveness. Untreated cells as well as cells pretreated with 10 microM retinoic acid for 4 days displayed a similar graded series of cell shapes between flat and spherical on these modified substrata, with the exception of HeLa-S3 cells which were rounded and loosely attached even on uncoated plastic dishes. A marked cell-shape-dependent decrease in DNA synthesis was observed in untransformed human skin fibroblasts, Swiss 3T3 fibroblasts and neoplastic human Hs791 cells 20 h following plating of untreated cells on poly(HEMA)-coated substrates of decreasing adhesiveness. Conversely, in B16-F1, HeLa-S3 and S91-C154 cells DNA synthesis was only slightly affected by changes in cell shape. Pretreatment with retinoic acid rendered DNA synthesis in Swiss 3T3, Hs791, B16-F1 and S91-C2 cells much more sensitive to changes in cell shape. In contrast, retinoic acid exerted only marginal effects on the sensitivity of DNA synthesis to changes in cell shape in untransformed human skin fibroblasts, in HeLa-S3 cells and in the retinoic-acid-resistant S91-C154 cells. The results suggest that retinoic acid can restore in certain tumor cells the tight coupling between cell shape and DNA synthesis that exists in untransformed cells.

Cell Communication↗

Poly-HEMA as a drug delivery device for in vitro neural networks on micro-electrode arrays.

Delivery of pharmacological agents in vitro can often be a difficult, time consuming and costly process. In this paper, we describe an economical method for in vitro delivery using a hydrogel of poly hydroxyethyl methacrylate (PHEMA) that can absorb up to 50% of its weight of any water-solubilized pharmacological agent. This agent will then passively diffuse into surrounding media upon application in vitro. An in vitro test of PHEMA as a drug delivery device was conducted using dissociated rat-cortical neurons cultured on micro-electrode arrays. These micro-electrode arrays permit the real-time measurement of neural activity at 60 different sites across a network of neurons. Neural activity was compared during the application of PHEMA saturated with cell culture media and PHEMA saturated with bicuculline, a widely used pharmacological agent with stereotypical effects on neural activity patterns. Application of PHEMA saturated with bicuculline produced a gradual increase in concentration in vitro. When the minimum effective concentration of bicuculline was reached, which was found to be 0.59 microM using the diffusion properties of PHEMA, it produced the rapid almost periodic synchronized bursting characteristically associated with this agent. In contrast, the application of PHEMA saturated in culture media alone had no effect on neural activity reinforcing its inherent inert properties. Since PHEMA is nontoxic, can be molded into a variety of shapes, quickly manufactured in any laboratory and is inexpensive to produce, the material represents a promising alternative to drug delivery systems on the market today.

Action Potentials↗

Minimized platelet interaction with poly(2-hydroxyethyl methacrylate-block-4-bis(trimethylsilyl)methylstyrene) hydrogel showing anomalously high free water content.

Novel hydrophilic-hydrophobic block copolymers - poly(2-hydroxyethyl methacrylate-block-4-bis(trimethylsilyl)methylstyrene) (poly(HEMA-block-BSMS) or BH polymer) - were prepared as materials potentially useful for blood-contacting devices. Among the BH(X) series including poly(HEMA) itself, platelet adhesion and activation are minimum on the surface of BH(10), the block copolymer composed of 10 mol% of the hydrophobic segment. The unique physicochemical characteristics of BH(10) such as the high free water content and the increased mobility of PHEMA segments seem to play an important role in the prevention of platelet adhesion and activation. The water content of BH(10) was twice that of poly(HEMA) itself, even in the presence of 10 mol% of the hydrophobic moiety [poly(BSMS)]. Further, an anomalous increase in free water content was observed for the BH(10) sample measured by DSC. The glass transition temperature of BH(10) in the dry state was determined to be c. 10 degrees C, which was much lower than that observed for each of the homopolymers (c.f.: Tg [poly(HEMA)] = 70 degrees C; Tg [poly(BSMS)] = 160 degrees C), suggesting an increased mobility of tethered PHEMA segments in the BH(10) film.

Acrylic Resins↗

Immobilization of acetylcholinesterase and choline oxidase in/on pHEMA membrane for biosensor construction.

In this study, acetylcholinesterase (AChE) and choline oxidase (ChO) were co-immobilized on poly(2-hydroxyethyl methacrylate) (pHEMA) membranes with the aim of using them in biosensor construction. pHEMA membranes were prepared with the addition of different salts in different HEMA: aqueous solution ratios and characterized in terms of porosity, thickness. permeability, and mechanical properties. Membranes prepared in the presence of SnCl4 were found to be superior in terms of porosity and permeability and were chosen as the immobilization matrix. Immobilization of the enzymes was achieved both by entrapment and surface attachment via epichlorohydrin (Epi) and Cibacron Blue F36A (CB) activation. The effect of immobilization on enzyme activity was evaluated by the comparison of Km and Vmax values for the free and immobilized bi-enzyme systems. The increase in Km was negligible (1.08-fold) for the bi-enzyme system upon immobilization on surface but was 2.12-fold upon entrapment. Specific activity of the free enzyme system was found to be 0.306 mV s(-1) microg(-1) ChO while it was 0.069 (4.43-fold decrease) for entrapped and 0.198 (1.54 fold decrease) for CB-Epi immobilized enzymes. The performance of immobilized enzymes in different buffer types, pH, and temperature conditions were evaluated. The best enzyme activity was obtained at pH 9.0. Activity of the enzymes was found to increase with increasing temperature (in the range 25-40 degrees C).

Acetylcholinesterase↗

Implantation of collagen IV/poly(2-hydroxyethyl methacrylate) hydrogels containing Schwann cells into the lesioned rat optic tract.

Poly (2-hydroxyethylmethacrylate) (PolyHEMA) hydrogels, when combined with extracellular matrix molecules and infiltrated with cultured Schwann cells, have the capability to induce CNS axonal regrowth after injury. We have further investigated these PolyHEMA hydrogels and their potential to bridge CNS injury sites. Collagen IV-impregnated hydrogels containing Schwann cells were implanted into the lesioned optic tract in 14 rats. On examination 2-4 months later, there was good adherence between the implants and CNS tissue, and large numbers of viable Schwann cells (S100+, GFAP+, Laminin+, and LNGFR+) were seen within the hydrogel matrices. Immunohistochemical analysis showed that the collagen IV-impregnated PolyHEMA hydrogels preferentially supported the transplanted Schwann cells and not host glial cells such as astrocytes (GFAP+) or oligodendroglia (CAII+). Macrophages (ED1+) were also seen within the sponge structure. Eighty-three percent of the implanted hydrogels contained RT97+ axons within their trabecular networks. Regrowing axons were associated with the transplanted Schwann cells and not with the small number of infiltrating astrocytes. RT97+ axons were traced up to 510 microm from the nearest host neuropil. These axons were sometimes myelinated by the transplanted Schwann cells and expressed the peripheral myelin marker Po+. WGA/HRP-labeled retinal axons were seen within transplanted hydrogel sponges, with 40% of the cases growing for distances up to 350-450 microm within the polymer network. The data indicate that impregnating PolyHEMA sponges with collagen IV can modify the host glial reaction and support the survival of transplanted Schwann cells. This study thus provides new information on how biomaterials could be used to modify and bridge CNS injury sites.

Animals↗

Improving the loading and release of NSAIDs from pHEMA hydrogels by copolymerization with functionalized monomers.

Poly(hydroxyethyl methacrylate), pHEMA, hydrogels are widely used for preparing implants, contact lenses, and other biomedical devices, which in many circumstances should load drugs to deliver them in the adjacent tissues. To enhance the potential of pHEMA hydrogels as nonsteroidal anti-inflammatory drugs (NSAIDs) delivery systems, 4-vinyl-pyridine (VP) and N-(3-aminopropyl) methacrylamide (APMA) were incorporated to the network (25-150 mM). The incorporated monomers did not change the viscoelastic properties neither the state of water, but remarkably increased the amount of ibuprofen (up to 10-fold) and diclofenac (up to 20-fold) loaded. Dried loaded pHEMA-APMA and pHEMA-VP hydrogels quickly swelled in water but ionic/hydrophobic interactions prevented the amount of drug released to be above 10%. By contrast, once the water-swollen hydrogels were transferred to pH 5.8 or 8.0 phosphate buffers or NaCl solutions, the release was prompted by competition with ions of the medium. The remaining of hydrophobic interactions and the high polymeric density of the pHEMA hydrogels contributed to sustain the release process for at least 24 h for ibuprofen and almost 1 week for diclofenac. The release rate was independent of the salt content and pH in the physiological range of values, which enables the design of hydrogel-based delivery systems with predictable release rate.

Anti-Inflammatory Agents, Non-Steroidal↗