PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Resolution of synthetic chi structures by the FLP site-specific recombinase.

The FLP site-specific recombinase is encoded by the two micron circle, an endogenous plasmid of Saccharomyces cerevisiae. FLP-mediated recombination in vitro proceeds via a short-lived Holliday (chi) intermediate. We have made a synthetic chi structure containing two FLP recognition target (FRT) sequences in order to investigate resolution by purified FLP protein. We found that incubation of this model substrate with FLP generated two pairs of linear products in equal quantities. Thus, resolution was equally likely to occur in either direction. Alteration of FLP binding sites, so as to inhibit binding, affected the direction of resolution; cleavage was reduced adjacent to the altered binding site. The overall efficiency of resolution increased when one FLP binding site was mutated. In investigating the series of mutated chi structures we found that resolution requires only two intact FLP binding sites. However, the non-specific protein-DNA interaction of additional FLP molecules may also be required. Thus, resolution is more tolerant of the loss of FLP binding sites than is the complete recombination reaction.

Base Sequence↗

Shope fibroma virus DNA topoisomerase catalyses holliday junction resolution and hairpin formation in vitro.

The telomeres of poxviral chromosomes comprise covalently closed hairpin structures bearing mismatched bases. These hairpins are formed as concatemeric replication intermediates and are processed into mature, unit-length genomes. The structural transitions and enzymes involved in telomere resolution are poorly understood. Here we show that the type I topoisomerase of Shope fibroma virus (SFV) can promote a recombination reaction which converts cloned SFV replication intermediates into hairpin-ended molecules resembling mature poxviral telomeres. Recombinant SFV topoisomerase linearised a palindromic plasmid bearing 1.5 kb of DNA encoding the SFV concatemer junction, at a site near the centre of inverted-repeat symmetry. Most of these linear reaction products bore hairpin tips as judged by denaturing gel electrophoresis. The resolution reaction required palindromic SFV DNA sequences and was inhibited by compounds which block branch migration (MgCl2) or poxviral topoisomerases. The resolution reaction was also slow, needed substantial quantities of topoisomerase, and required that the palindrome be extruded in a cruciform configuration. DNA cleavage experiments identified a pair of suitably oriented topoisomerase recognition sites, 90 bases from the centre of the cloned SFV terminal inverted repeat, which may mark the resolution site. These data suggest a resolution scheme in which branch migration of a Holliday junction through a site occupied by covalently bound topoisomerase molecules, could lead to telomere resolution.

DNA Topoisomerases, Type I↗

Low-resolution density maps from atomic models: how stepping "back" can be a step "forward".

Atomic-resolution structures have had a tremendous impact on modern biological science. Much useful information also has been gleaned by merging and correlating atomic-resolution structural details with lower-resolution (15-40 A), three-dimensional (3D) reconstructions computed from images recorded with cryo-transmission electron microscopy (cryoTEM) procedures. One way to merge these structures involves reducing the resolution of an atomic model to a level comparable to a cryoTEM reconstruction. A low-resolution density map can be derived from an atomic-resolution structure by retrieving a set of atomic coordinates editing the coordinate file, computing structure factors from the model coordinates, and computing the inverse Fourier transform of the structure factors. This method is a useful tool for structural studies primarily in combination with 3D cryoTEM reconstructions. It has been used to assess the quality of 3D reconstructions, to determine corrections for the phase-contrast transfer function of the transmission electron microscope, to calibrate the dimensions and handedness of 3D reconstructions, to produce difference maps, to model features in macromolecules or macromolecular complexes, and to generate models to initiate model-based determination of particle orientation and origin parameters for 3D reconstruction.

Algorithms↗

Low- and high-resolution mapping of DNA damage at specific sites.

Measurement of DNA damage and repair at the nucleotide level in intact cells has provided compelling evidence for the molecular details of these events as they occur in intact organisms. Furthermore, these measurements give the most accurate picture of the rates of repair in different structural domains of DNA in chromatin. In this report, we describe two methods currently used in our laboratories to map DNA lesions at (or near) nucleotide resolution in yeast cells. The low-resolution method couples damage-specific strand breaks in DNA with indirect end-labeling to measure DNA lesions over a span of 1.5 to 2 kb of DNA sequence. The resolution of this method is limited by the resolution of DNA length measurements on alkaline agarose gels (about +/-20 bp on average). The high-resolution method uses streptavidin magnetic beads and special biotinylated oligonucleotides to facilitate end-labeling of DNA fragments specifically cleaved at damage sites. The latter method maps DNA damage sites at nucleotide resolution over a shorter distance (<500 bp), and is constrained to the length of DNA resolvable on DNA sequencing gels. These methods are used in tandem for answering questions regarding DNA damage and repair in different chromatin domains and states of gene expression.

Biotinylation↗

A novel approach to high resolution fetal brain MR imaging.

This paper describes a novel approach to forming high resolution MR images of the human fetal brain. It addresses the key problem of motion of the fetus by proposing a registration refined compounding of multiple sets of orthogonal fast 2D MRI slices, that are currently acquired for clinical studies, into a single high resolution MRI volume. A robust multi-resolution slice alignment is applied iteratively to the data to correct motion of the fetus that occurs between 2D acquisitions. This is combined with an intensity correction step and a super resolution reconstruction step, to form a single high isotropic resolution volume of the fetal brain. Experimental validation on synthetic image data with known motion types and underlying anatomy, together with retrospective application to sets of clinical acquisitions are included. Results indicate the method promises a unique route to acquiring high resolution MRI of the fetal brain in vivo allowing comparable quality to that of neonatal MRI. Such data is highly valuable in allowing a clinically applicable window into the process of normal and abnormal brain development.

Algorithms↗

The influence of image resolution on the positron emission tomographic measurement of caudate glucose consumption.

The aim of this study was to investigate the influence of image resolution on (a) relative and absolute values of caudate glucose consumption (rCMRGlc) determined by positron emission tomography (PET), and (b) the detection of significant differences in these metabolic values between groups of subjects. For this purpose, raw data of cerebral accumulation of fluorine-18 fluorodeoxyglucose (FDG) obtained in 11 normal subjects and in nine patients with unilateral thalamic infarction were reconstructed using filtered backprojection with four different cut-off frequencies (CFs), yielding images with a transaxial resolution of 5.7, 7.1, 8.9 and 11 mm (full-width at half-maximum; FWHM). Absolute values of caudate rCMRGlc decreased significantly by more than 30% over the range of image resolutions studied. Bilateral ratios of caudate rCMRGlc were insensitive to variations in image resolution. Levels of significance assessing the differences in mean metabolic values between patients and controls were all below 0.01. They were, however, slightly better at image resolutions of 7.1 and 8.9 mm than at a resolution of 5.7 mm. These data indicate (a) that relative values of rCMRGlc are better suited to compare quantitative results from different PET cameras than are absolute values, and (b) that the CF used for the filtered back-projection exerts a small but not negligible influence on levels of significance assessing differences in metabolic values between groups of subjects.

Adult↗

Influence of transcription and replication on the in situ resolution of immunoglobulin heavy-chain constant region genes: an interphase cytogenetics analysis.

An interphase cytogenetics analysis was performed to investigate whether replication and transcription could influence in situ resolution of immunoglobulin (Ig) heavy chain constant region genes. A plasmid probe recognizing five C gamma segments separated by known linear DNA distances was hybridized in situ and visualized by digital fluorescence microscopy. In interphase nuclei from phytohemagglutinin (PHA)-stimulated lymphocytes, the gamma genes were resolved as one to three signals per allele in the majority of nuclei, whereas in a minority, complex patterns of several signals per allele could be observed. The latter were restricted to nuclei in an early stage of the S phase, as assessed by hybridization experiments performed in cells grown in the presence of bromodeoxyuridine. To investigate whether the in situ resolution of the C gamma segments could vary as a function of the transcription activity of the locus, the C gamma probe was subsequently hybridized to nuclei from a mature B cell line (JVM-2), which produces gamma transcripts as shown by in situ RNA hybridization experiments. Primary human fibroblasts were further used as representative of a non-lymphoid cell type with transcriptionally inactive Ig genes. When Gl nuclei from the three cell types were compared in terms of the in situ resolution of the C gamma locus, JVM-2 cells were found to include the highest percentage of higher resolution patterns (three to five signals per allele in 28% of nuclei), fibroblasts the lowest (three signals per allele, 2%), while PHA-stimulated lymphocytes occupied an intermediate position between the other two cell types (three or four signals per allele, 15%). The data show that the in situ resolution of Ig C gamma genes varies throughout the cell cycle and is influenced by the transcriptional activity of the locus. The variability of the resolution patterns observed appears to reflect different levels of chromatin packaging, which in turn are likely to influence the probe accessibility to its target. These observations are relevant for the interpretation of data from interphase cytogenetics analysis of independent, but closely spaced, DNA segments.

Cells, Cultured↗

Use of scanner characteristics in iterative image reconstruction for high-resolution positron emission tomography studies of small animals.

The purpose of this work was to improve of the spatial resolution of a whole-body positron emission tomography (PET) system for experimental studies of small animals by incorporation of scanner characteristics into the process of iterative image reconstruction. The image-forming characteristics of the PET camera were characterized by a spatially variant line-spread function (LSF), which was determined from 49 activated copper-64 line sources positioned over a field of view (FOV) of 21.0 cm. This information was used to model the image degradation process. During the course of iterative image reconstruction, the forward projection of the estimated image was blurred with the LSF at each iteration step before the estimated projections were compared with the measured projections. The imaging characteristics of the high-resolution algorithm were investigated in phantom experiments. Moreover, imaging studies of a rat and two nude mice were performed to evaluate the imaging properties of our approach in vivo. The spatial resolution of the scanner perpendicular to the direction of projection could be approximated by a one-dimensional Gaussian-shaped LSF with a full-width at half-maximum increasing from 6.5 mm at the centre to 6.7 mm at a radial distance of 10.5 cm. The incorporation of this blurring kernel into the iteration formula resulted in a significantly improved spatial resolution of about 3.9 mm over the examined FOV. As demonstrated by the phantom and the animal experiments, the high-resolution algorithm not only led to a better contrast resolution in the reconstructed emission scans but also improved the accuracy for quantitating activity concentrations in small tissue structures without leading to an amplification of image noise or image mottle. The presented data-handling strategy incorporates the image restoration step directly into the process of algebraic image reconstruction and obviates the need for ill-conditioned "deconvolution" procedures to be performed on the projections or on the reconstructed image. In our experience, the proposed algorithm is of special interest in experimental studies of small animals.

Algorithms↗

Phosphorylation-induced conformational changes in the phosphorylase ab hybrid as revealed by resolution of pyridoxal 5'-phosphate with imidazole citrate and cysteine.

The accessibility of pyridoxal 5'-phosphates of the phosphorylase ab hybrid to resolution by imidazole citrate and cysteine was studied and compared with that of the b and a forms. Promotion of resolution of phosphorylated forms by raising the temperature or in the presence of glycogen indicates that the resistance of phosphorylase a and ab to resolution at 0 degrees C is due rather to their tetrameric state than their phosphorylation-related active conformation. The pattern of resolution of the ab hybrid was similar to that of the a and differed from that of the b forms in that it occurred at 30 degrees C and 37 degrees C but not at 0 degrees C, moreover, it did not show first-order kinetics. On the other hand, inhibition of resolution by ligands binding to the nucleotide site of phosphorylase reflected an intermediate sensitivity of the ab form between that of the b and a forms. We conclude that partial phosphorylation of phosphorylase b elicits conformational change(s) in both subunits which influence the monomer-monomer interactions and resolution of pyridoxal 5'-phosphates. Resistance of ab hybrid to monomerizing agents as imidazole citrate, comparable to that of other forms, argues for its stability, ruling out its reshuffling into mixtures of phosphorylase b and a.

Adenosine Monophosphate↗

The relevance of interictal rCBF brain SPECT in temporal lobe epilepsy: diagnostical value and effects of spatial resolution.

Interictal rCBF-SPECT is frequently being used as an adjunctive method for localization of an epileptogenic area during presurgical evaluation of patients suffering from medically refractory temporal lobe epilepsy. This study retrospectively evaluates interictal rCBF-SPECT using Tc-99m-HMPAO in comparison to the results of MRI. The final results of surface EEG and ECoG and the postsurgical clinical results as to seizure frequency were used a a 'gold-standard' for the evaluation of both imaging procedures. As spatial resolution is discussed to be the major reason for higher sensitivity of F-18-DG-PET compared to rCBF-SPECT, special attention has been paid to the spatial resolution of the different SPECT systems being used in this study. In 55 patients the complete data set could be obtained retrospectively, 36 of them being evaluated using SPECT systems with relatively low spatial resolution (Picker Dyna 2000, Elscint Helix) and 19 pt. being evaluated using moderate- to high-resolution SPECT systems (ADAC Genesys, DSI Ceraspect). Overall sensitivity of the interictal rCBF-SPECT was 75%, with 69% for low-resolution systems and 84% for high-resolution systems. Approximately at the same time when our institution installed the ADAC Genesys, the MRI equipment was changed form the 1.5 T Philips Gyroscan S15 to the 1.5 T Philips Gyroscan ACS II, the latter allowing superior imaging opportunities. Overall sensitivity of MRI was 60%, with 56%, for the Gyroscan S15 and 68% for the Gyroscan ACS II. The overall positive predictive value (PPV) was 87% for the interictal rCBF-SPECT and 87% for the MRI. Due to the lack of true negative studies in this population specificity was not calculated. False lateralization using rCBF-SPECT occurred in 5 pts. (9%), however, in 3 pts. the area of hypoperfusion correlated with a detectable MRI pathology, yet EEG/ECoG revealed the epileptogenic focus to be elsewhere. In conclusion, the interictal rCBF-SPECT revealed reasonable sensitivity and PPV in pt. suffering from focal temporal lobe epilepsy and modern SPECT systems showed significantly improved results. Since there is a variety of possible reasons for regional cortical hypoperfusion, the interictal SPECT could add significant information prior to the application of ECoG. This specially appeared to be useful in patients with abnormal MRI scan. Furthermore, in patients presenting with a clear pathology on MRI and a corresponding EEG focus, ECoG could be avoided if the interictal rCBF-SPECT additionally showed localized and singular involvement of the affected temporal lobe. ECoG was mainly applied in those patients with relatively wide-spread hypoperfusion additionally involving frontal or parietal cortical areas.

Adolescent↗

Radiographic resolution of lymphocytic interstitial pneumonitis (LIP) in children with human immunodeficiency virus (HIV): not a sign of clinical deterioration.

BACKGROUND: The literature and anecdotal evidence associate the resolution of radiographic findings of lymphocytic interstitial pneumonitis (LIP) with a decline in immune and clinical status of human immunodeficiency virus (HIV) infected children. OBJECTIVE: As our clinical impression was the opposite, we sought to elucidate this contradiction. MATERIALS AND METHODS: Of 52 pediatric patients infected with the HIV currently being followed at our institution, 20 (38.5%) carried the diagnosis of LIP and 13 (65%) of these have had complete resolution of radiographic findings of LIP. We retrospectively reviewed the chest radiographs, CD4 counts, and clinical history of these 13 patients. RESULTS: Of the 13 patients who had resolution of radiographic findings, 11 (84.6%) had no significant change in CD4 count at the time of resolution and remained clinically stable during a mean follow-up period of 32 months. Two patients (15.3%) developed severe CD4 lymphocytopenia at the time of resolution of LIP, but clinically remained stable. None of these 13 patients had a recurrence of LIP, even with subsequent increases in CD4 count. CONCLUSION: We suggest that in contradiction to previously published data, resolution of LIP on chest radiographs is not an indicator for poor prognosis for the HIV-infected pediatric patient.

CD4 Lymphocyte Count↗

The influence of photon depth of interaction and non-collinear spread of annihilation photons on PET image spatial resolution.

PURPOSE: The quality of PET imaging is impaired by parallax errors. These errors produce misalignment between the projected location of the true origin of the annihilation event and the line of response determined by the coincidence detection system. Parallax errors are due to the varying depths of photon interaction (DOI) within the scintillator and the non-collinear (NC) emission of the annihilation photons. The aim of this work was to address the problems associated with the DOI and the NC spread of annihilation photons and to develop a quantitative model to assess their impact on image spatial resolution losses for various commonly used scintillators and PET geometries. METHODS: A theoretical model based on Monte Carlo simulations was developed to assess the relative influence of DOI and the NC spread of annihilation photons on PET spatial resolution for various scintillator materials (BGO, LSO, LuAP, GSO, NaI) and PET geometries. RESULTS: The results demonstrate good agreement between simulated, experimental and published overall spatial resolution for some commercial systems, with maximum differences around 1 mm in both 2D and 3D mode. The DOI introduces an impairment of non-stationary spatial resolution along the radial direction, which can be very severe at peripheral positions. As an example, the radial spatial resolution loss due to DOI increased from 1.3 mm at the centre to 6.7 mm at 20 cm from the centre of a BGO camera with a 412-mm radius in 2D mode. Including the NC, the corresponding losses were 3.0 mm at the centre and 7.3 mm 20 cm from the centre. CONCLUSION: Without a DOI detection technique, it seems difficult to improve PET spatial resolution and increase sensitivity by reducing the detector ring radius or by extending the detector in the axial direction. Much effort is expended on the design and configuration of smaller detector elements but more effort should be devoted to the DOI complexity.

Artifacts↗

The pinhole: gateway to ultra-high-resolution three-dimensional radionuclide imaging.

Today the majority of clinical molecular imaging procedures are carried out with single-photon emitters and gamma cameras, in planar mode and single-photon emission computed tomography (SPECT) mode. Thanks to the development of advanced multi-pinhole collimation technologies, SPECT imaging of small experimental animals is rapidly gaining in popularity. Whereas resolutions in routine clinical SPECT are typically larger than 1 cm (corresponding to >1,000 microl), it has recently proved possible to obtain spatial resolutions of about 0.35 mm ( approximately 0.04 microl) in the mouse. Meanwhile, SPECT systems that promise an even better performance are under construction. The new systems are able to monitor functions in even smaller structures of the mouse than was possible with dedicated small animal positron emission tomography ( approximately 1 mm resolution, corresponding to 1 microl). This paper provides a brief history of image formation with pinholes and explains the principles of pinhole imaging and pinhole tomography and the basics of modern image reconstruction methods required for such systems. Some recently introduced ultra-high-resolution small animal SPECT instruments are discussed and new avenues for improving system performance are explored. This may lead to many completely new biomedical applications. We also demonstrate that clinical SPECT systems with focussing pinhole gamma cameras will be able to produce images with a resolution that may become superior to that of PET for major clinical applications. A design study of a cardiac pinhole SPECT system indicates that the heart can be imaged an order of magnitude faster or with much more detail than is possible with currently used parallel-hole SPECT (e.g. 3-4 mm instead of approximately 8 mm system resolution).

Animals↗

A comparison of spatial and spectral image resolution for mapping invasive plants in coastal california.

We explored the potential of detecting three target invasive species: iceplant (Carpobrotus edulis), jubata grass (Cortaderia jubata), and blue gum (Eucalyptus globulus) at Vandenberg Air Force Base, California. We compared the accuracy of mapping six communities (intact coastal scrub, iceplant invaded coastal scrub, iceplant invaded chaparral, jubata grass invaded chaparral, blue gum invaded chaparral, and intact chaparral) using four images with different combinations of spatial and spectral resolution: hyperspectral AVIRIS imagery (174 wavebands, 4 m spatial resolution), spatially degraded AVIRIS (174 bands, 30 m), spectrally degraded AVIRIS (6 bands, 4 m), and both spatially and spectrally degraded AVIRIS (6 bands, 30 m, i.e., simulated Landsat ETM data). Overall success rates for classifying the six classes was 75% (kappa 0.7) using full resolution AVIRIS, 58% (kappa 0.5) for the spatially degraded AVIRIS, 42% (kappa 0.3) for the spectrally degraded AVIRIS, and 37% (kappa 0.3) for the spatially and spectrally degraded AVIRIS. A true Landsat ETM image was also classified to illustrate that the results from the simulated ETM data were representative, which provided an accuracy of 50% (kappa 0.4). Mapping accuracies using different resolution images are evaluated in the context of community heterogeneity (species richness, diversity, and percent species cover). Findings illustrate that higher mapping accuracies are achieved with images possessing high spectral resolution, thus capturing information across the visible and reflected infrared solar spectrum. Understanding the tradeoffs in spectral and spatial resolution can assist land managers in deciding the most appropriate imagery with respect to target invasives and community characteristics.

California↗

Understanding Dispute Resolution Processes for American and Australian Public Wildlands: Towards a Conceptual Framework for Managers.

/ The last 20 years have seen the successful application of environmental dispute resolution processes, where people voluntarily negotiate toward mutually acceptable solutions, to many environmental disputes. The effects of contextual influences, such as the number of parties and presence of deadlines, on outcomes are known and frequently described. Less well documented and understood are the interaction processes themselves. This paper draws on two case studies to develop a conceptual framework describing these processes. Disputes associated with management planning for the Bob Marshall Wilderness Complex in the United States and Fitzgerald River National Park in Australia provided the cases. The conceptual framework derived had eight sequential stages: (1) joint definition of problems, (2) uncertainty about what to do, (3) agreement on group procedures, (4) realization of interdependence, (5) enthusiasm about collective possibilities, (6) commitment to working together, (7) consolidation of the group, and (8) implementation of a resolution. The framework provides new insights for managers of public wildlands, especially the need for varying but ongoing managerial involvement in dispute resolution processes. High levels of involvement and influence are essential at the beginning in problem definition and group procedure design and at the end in implementing resolutions. Conversely, agency members must be willing to exert less influence, while still being involved and committed to collective purposes, during the middle stages. Also apparent from the conceptual framework is the importance of developing shared understandings and of allowing sufficient time for understanding to develop, if successful resolution is to be achieved. KEY WORDS: Environmental dispute resolution; Conceptual framework; Public wildlands; Shared understandings; Australia

Journal Article↗

Combination of low and high resolution sequences in two orientations for dynamic contrast-enhanced MRI of the breast: more than a compromise.

The purpose was to combine T1-weighted 3D gradient echo sequences at low and high spatial resolution (and short and longer acquisition time, respectively) in two orientations without compromising signal/time curve analysis and to evaluate the incremental value of assessing architectural features in high resolution images in dynamic contrast-enhanced MR mammography. T1-weighted 3D-FLASH sequences in a 1.5-T scanner (512 x 256 pixel matrix at high resolution; 256 x 128 pixels at low resolution sequences, 72 slices, 1.7-mm slice thickness, TR 8.8 ms, TE 4.5 ms, flip angle 25 degrees) were acquired in a special order during a single investigation. Three observers evaluated architectural features of 36 histopathologically proven lesions using high or low resolution images independently. Architectural features of each lesion were assessed by rating on two three-point scales. Kappa statistics verified the decrease of inter-observer variability. All observers improved assessment of architectural features regarding high resolution images in transversal and coronal orientation (observer A: eight positive, three negative corrections; B: 12/5; C: 16/4). Most positive corrections resulted from improved detection of morphologic criteria of malignancy. Mean inter-observer agreement significantly (P<0.05) increased from "slight" to "moderate" (mean weighted kappa increased from 0.185 to 0.422). This protocol at the charge of slightly enlarged time for measurement offers an elegant way to improve analysis of architectural features in MRM.

Adolescent↗

Evaluation of spatial and temporal resolution for ECG-gated 16-row multidetector CT using a dynamic cardiac phantom.

Measurements of spatial and temporal resolution for ECG-gated scanning of a stationary and moving heart phantom with a 16-row MDCT were performed. A resolution phantom with cylindrical holes from 0.4 to 3.0 mm diameter was mounted to a cardiac phantom, which simulates the motion of a beating heart. Data acquisition was performed with 16x0.75 mm at various heart rates (HR, 60-120 bpm), pitches (0.15-0.30) and scanner rotation times (RT, 0.42 and 0.50 s). Raw data were reconstructed using a multi-cycle real cone-beam reconstruction algorithm at multiple phases of the RR interval. Multi-planar reformations (MPR) were generated and analyzed. Temporal resolution and cardiac cycles used for image reconstruction were calculated. In 97.2% (243/250) of data obtained with the stationary phantom, the complete row of holes with 0.6 mm was visible. These results were independent of heart rate, pitch, scanner rotation time and phase point of reconstruction. For the dynamic phantom, spatial resolution was determined during phases of minimal motion (116/250). In 40.5% (47/116), the resolution was 0.6 mm and in 37.1% (43/116) 0.7 mm. Temporal resolution varied between 63 and 205 ms, using 1.5-4.37 cardiac cycles for image reconstruction.

Electrocardiography↗

MRI of the pelvis at 3 T: very high spatial resolution with sensitivity encoding and flip-angle sweep technique in clinically acceptable scan time.

OBJECTIVE: The higher signal at 3.0-T allows spatial resolution to be increased without loss in image quality. We evaluated a T2-weighted turbo spin-echo sequence with high spatial resolution (3T-HR) to determine whether this provides clinically useful pelvic MRI. MATERIALS AND METHODS: We designed a sequence with high spatial resolution (3T-HR) (0.45x0.46x4 mm) that was combined with parallel imaging and the variable refocusing angle technique (8.06 min). We examined 23 patients with gynecological disorders using 3T-HR and a standard sequence (3T-SP; 4.03 min; equivalent to 1.5 T). Two radiologists analyzed tissue contrast, signal to noise, detail delineation and artifact level. RESULTS: Tissue contrasts and signal to noise were rated equal. Motion artifacts occurred more often with 3T-SP despite the longer scanning time of 3T-HR. The higher spatial resolution provided additional information in four patients. In two patients small myomas were detected, in one patient a lymph node metastasis was apparent, and in one patient 3T-HR excluded tumor invasion. CONCLUSIONS: High spatial resolution pelvic studies with high image quality can be obtained at 3 T in acceptable scan time. The higher spatial resolution that is feasible at 3 T also provides more clinically relevant information.

Adolescent↗