PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Supine Position”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

The hemodynamic and metabolic basis for decreased aerobic capacity in the supine exercise compared with the upright exercise in coronary artery disease.

To elucidate the mechanism of reduced exercise tolerance in the supine position, 14 patients with coronary artery disease were studied by both supine ergometer exercise and upright treadmill exercise. Maximal oxygen consumption in the supine position amounted to 80% of that in the upright position (1110 +/- 453 vs 1387 +/- 470 ml/min; p less than 0.001). Maximal cardiac output was identical in both positions (12.07 +/- 4.44 vs 12.55 +/- 4.49 l/min; ns). Maximal arteriovenous oxygen difference in the supine position amounted to 83% of that in the upright position (9.22 +/- 1.92 vs 11.14 +/- 1.88 vol%; p less than 0.01). Thus, the lower maximal oxygen consumption in the supine position was not caused by the decreased cardiac output but by the impaired augmentation of arteriovenous oxygen difference. Lactate concentration at the same oxygen consumption was higher in the supine position, which means early augmentation of anaerobic metabolism. We concluded that the aerobic capacity in the supine position was significantly lower than that in the upright position in patients with coronary artery disease, and the impaired utilization of transported oxygen was considered to be one of the mechanisms of the decreased aerobic capacity in the supine position.

Adult↗

Maternal half-sitting position in the second stage of labor.

The maternal half-sitting and supine position during the second stage of fullterm labor was compared in 100 women who, after identical opening phases in supine position, randomly delivered in half-sitting (50 degrees, n = 50) or supine position (n = 50). The whole duration of the second stage of labor or the time spent in active pushing did not differ between the groups. Vacuum extraction was needed twice (4%) in the group delivering in half-sitting and six times (12%) in the group delivering in supine position. Vaginal tear occurred in one mother in both groups. Early decelerations in fetal cardiotocography were seen 22 times in half-sitting and 14 times in supine group (p less than 0.05). However, late decelerations were seen in only one mother with half-sitting, as compared to five mothers with supine position. Four infants of mothers giving birth in supine position had 1 minute APGAR scores 7 or less, whereas all infants of mothers delivering in half-sitting position had APGAR scores higher than 7. Subjectively the mothers liked more the half-sitting position. We conclude that a women can deliver in half-sitting position without maternal or fetal risks.

Adult↗

[Effect of crankshaft position on the results of supine bicycle ergometry testing. Hemodynamics in coronary heart disease patients with normal and impaired left ventricular function].

In 50 patients with coronary heart disease (CHD), 44 of them with a recent history of myocardial infarction, 2 tests on the bicycle-ergometer in the supine position, one with the crankshaft on the level of the examination cot and one with an elevation of the pedal axle by 30 cm were carried out within 30-minute intervals after initiating a flow directed right heart catheterization. In chronological sequence of the recruitment the patients began the ergometric tests alternately with a low or an elevated crank. The applied exercise loads of 50 and 75 watts lasted 3 minutes each. The results show clinically relevant differences between the 2 positions of the pedal axle, being in many cases statistically significant (p less than or equal to 0.01). The pressure of the pulmonary artery (PAP) was elevated at rest and under exercise load when the pedal axle was elevated. The changes of the pressure of the pulmonary artery through the exercise load are greater in patients with an impaired left ventricular function at rest with both pedal axle positions than in patients with a normal left ventricular function. We observed under increasing exercise load a diverging more pronounced elevation of PAP-curves only as a trend in the group of patients with an impaired left ventricular function. Heart rate and systolic blood pressure were on average likewise higher with the elevated crank then with the low one, however the mean variations were considerable. The oxygen saturation of the blood was somewhat less at rest and during exercise load when the pedal axle was elevated compared to the findings with the low pedal axle. The decrease of the oxygen saturation under exercise load was most pronounced in patients having already at rest an impaired left ventricular function. However, with both positions of the pedal axle the behaviour was identical.

Adult↗

Acid gastro-esophageal reflux in the 10 degrees-reversed-Trendelenburg-position in supine sleeping infants.

Many pediatricians recommend, empirically, the "supine reversed-Trendelenburg sleeping position" in infant regurgitation, although its efficacy has not been validated. Esophageal pH monitoring data from 10 consecutively investigated regurgitating infants show that the acid reflux parameters in all of them were increased in the "supine reversed-Trendelenburg position at 10 degrees" in comparison to the flat supine sleeping position. We conclude that further studies are needed to evaluate the effect of the "supine reversed-Trendelenburg position" on reflux parameters before recommending this position as a possible treatment to decrease esophageal acid exposure.

Female↗

The influence of postural changes on gastroesophageal reflux and barrier pressure in nonfasting individuals.

UNLABELLED: There is controversy regarding optimal body positioning (i.e., head-up, head-down) in awake nonfasting individuals to minimize the risk for pulmonary aspiration of gastric contents as the result of gastroesophageal reflux (GER). In the present study, we investigated GER and intragastric-esophageal barrier pressure by means of multichannel intraluminal impedance measurement and intragastric-esophageal manometry in awake, nonfasting volunteers randomly positioned in a 20 degrees head-up position, the supine position, and a 20 degrees head-down position. No significant difference among positions was found with respect to number of GER episodes per person (0/1/1) or intragastric-esophageal barrier pressure (15.6/19.6/19.4 mm Hg). We conclude that specific body positioning is useless in the prophylaxis of GER in awake nonfasting individuals. IMPLICATIONS: Tilting of nonfasting individuals to the head-up or head-down position recommended for prevention of regurgitation of gastric contents does not influence the frequency of gastroesophageal reflux.

Adult↗

Evaluation of the image quality of temporal subtraction images produced automatically in a PACS environment.

The aim of the study is to evaluate the reliable production of temporal subtraction images in a picture archiving and communication system environment and to establish objective criteria for the evaluation of image quality. A total of 117 temporal subtraction chest images (55 in the upright position, 62 in the supine position) were obtained in five consecutive days. In all of these, we confirmed that there were no interval changes on the original images, and cases with diffuse lung disease were excluded. The temporal subtraction images were classified by three chest radiologists into five levels: 5, excellent; 4, good; 3, acceptable; 2, poor; and 1, very poor. The following were examined: (1) the yield of adequate quality of the temporal subtraction images; (2) whether the temporal subtraction images were obtained in the warping or nonwarping mode; and (3) the correlation of the overall subjective image quality with the relative shift angles, relative shift distances, and the standard deviation of gray levels in the temporal subtraction images. The percentages of acceptable temporal subtraction images were 100% and 66% in the upright and supine positions, respectively. Sixteen (26%) of the 62 supine-position images were made in nonwarping mode, whereas all upright images were made in warping mode. Significant correlations were obtained in the relative shift angle (P < 0.05), relative horizontal shift distance (P < 0.05), and standard deviation of gray levels (P < 0.0001). Temporal subtraction images with acceptable image quality were obtained in the upright position. The objective criteria may be useful for the evaluation of image quality.

Humans↗

[Effect of changing position from supine to standing upright on the circulation of young men and women].

This study investigated the effect of changing position from supine to standing upright on the circulation of young men and women. Healthy men and women ranging from age of 18 to 24 were examined. Two minutes before standing, the baseline heart rate and blood pressure were measured. Heart rate and blood pressure were recorded immediately and at every minute for 10 minutes after standing upright. Differences in heart rate and blood pressure between supine and standing upright position were evaluated. The results were summarized as follows: 1. Heart rate increased significantly immediately and at every minute for 10 minutes after standing upright. 2. Systolic blood pressure increased significantly immediately and at every minute for 4 minutes after standing upright. 3. Diastolic and mean blood pressure increased significantly immediately and at every minute for 10 minutes after standing upright. 4. Pulse pressure immediately and at every minute for 10 minutes after standing upright was significantly narrower than that of supine position. 5. There was no significant difference of heart rate between men and women after standing upright. 6. Systolic and diastolic blood pressure of men after standing upright was significantly greater than those of women. From these results, it may be concluded that heart rate, systolic, diastolic and mean blood pressure and pulse pressure increase after standing upright, and systolic and diastolic blood pressure in men is greater than those of women after standing upright.

Adult↗

Shape and tension distribution of the active canine diaphragm.

Both diaphragm shape and tension contribute to transdiaphragmatic pressure, but of the three variables, tension is most difficult to measure. We measured transdiaphragmatic pressure and the global shape of the in vivo canine diaphragm and used principles of mechanics to compute the tension distribution. Our hypotheses were that 1) tension in the active diaphragm is nonuniform with greater tension in the central tendon than in the muscular regions; 2) maximum tension is essentially oriented in the muscle fiber direction, whereas minimum tension is orthogonal to the fiber direction; and 3) during submaximal activation change in the in vivo global shape is small. Metallic markers, each 2 mm in length, were implanted surgically on the peritoneal surface of the diaphragm at 1.5- to 2.0-cm intervals along the muscle bundles at the midline, ventral, middle, and dorsal regions of the left costal diaphragm and along a muscle bundle of the crural diaphragm. Postsurgery, a biplane videofluoroscopic system was used to determine the in vivo three-dimensional coordinates of the markers at end expiration and end inspiration during quiet breathing as well as at end-inspiratory efforts against an occluded airway at lung volumes of functional residual capacity and at one-third maximum inspiratory capacity increments in volume to total lung capacity. A surface was fit to the marker locations using a two-dimensional spline algorithm. Diaphragm surface was modeled as a pressurized membrane, and tension distribution in the active diaphragm was computed using the ANSYS finite element program. We showed that the peak of the diaphragm dome was closer to the ventral surface than to the dorsal surface and that there was a depression or valley in the crural region. In the supine position, during inspiratory efforts, the caudal displacement of the dorsal region of the diaphragm was greater than that of the dome, and the valley along the crural diaphragm was accentuated. In contrast, at lower lung volumes in the prone posture, the caudal displacement of the dome was greater than that of the crural region. At end of inspiration, transdiaphragmatic pressure was approximately 6.5 cmH2O, and tensions were nonuniform in the diaphragm. Maximum principal stress sigma(1) of central tendon was found to be greater than sigma(1) of the costal region, and that was greater than sigma(1) of the crural region, with values of 14-34, 14-29, and 4-14 g/cm, respectively. The corresponding data of the minimum principal stress sigma(2) were 9-18, 3-9, and 0-1.5 g/cm, respectively. Maximum principal tension was approximately parallel to the muscle fibers, whereas minimum tension was essentially orthogonal to the longitudinal direction of the muscle fibers. In the muscular region, sigma(1) was approximately 3-fold sigma(2), whereas in the central tendon, sigma(1) was only approximately 1.5-fold sigma(2.).

Animals↗

Relationship between power spectral densities of P-P and R-R intervals.

To investigate the role of the peripheral effector for the generation of heart rate variability, the relationship among the P-P, R-R, P-R, and R-P intervals were compared on five healthy male subject in the supine position. During supine rest, electrocardiogram was monitored, and P-P, R-R, P-R, and R-P intervals were measured. Power spectral densities (PSD) were estimated by using direct method for successive 256 intervals. PSDs were integrated at the low (PSDLF; 0.05-0.15 cycle/beat) and high (PSDHF; 0.20-0.40 cycle/beat) frequency bands. Mean interval times of P-P, R-R, R-P, and P-R intervals were 827 +/- 40, 827 +/- 40, 357 +/- 34, 170 +/- 19 msec, respectively. PSDLFS of P-P, R-R, R-P, and P-R intervals were 15677 +/- 2771, 15566 +/- 2815, 15345 +/- 2767, 1491 +/- 255 msec2/c/b, respectively. PSDHFS of P-P, R-R, R-P, and P-R intervals were 13289 +/- 3602, 12918 +/- 3897, 12558 +/- 3630, 2758 +/- 517 msec2/c/b, respectively. The PSD of P-R intervals showed white noise. These results might suggest that the periodic fluctuation would be formed at or above the sinoatrial node.

Adult↗

[Respiratory effects of epidural anesthesia and anesthetic level obtained in patients for cesarean section].

In order to determine the optimal level of epidural anesthesia, the author examined respiratory function of 138 full-term pregnant women in sitting and supine positions without anesthesia, and in supine position under epidural anesthesia prior to the cesarean section. Vital capacity (VC) increased in the sitting position in comparison with supine position because expiratory reserve volume (ERV) and tidal volume (TV) increased. In contrast, %FFV1.0, peak expiratory flow (PEF) and V75 decreased as uterus shifted anteriorly in the sitting position. Under the epidural anesthesia with T4-T6 analgesic, TV showed a relative increase resulting in an increase in VC. This was due to lateral displacement of the uterus alleviating the depression of diaphragm. Epidural anesthesia with levels C8-T3 caused a reduction in inspiratory reserve volume (IRV) and ERV which in turn resulted in a decrease in VC and PaCO2. This change depended on the paralysis of respiratory muscles and the dyspneic feeling of patient. Generally %FFV1.0 and the data related to flow volume curve decreased under epidural anesthesia. In conclusion, epidural anesthesia with T4-T6 levels accompanied a sufficient analgesic efficacy and respiratory function comparable with that in the sitting position without anesthesia, therefore this was considered to be a method of choice for cesarean section.

Adult↗

The value of prone scanning to distinguish ureterovesical junction stones from ureteral stones that have passed into the bladder: leave no stone unturned.

OBJECTIVE: When a stone is located in the region of the ureterovesical junction on CT studies, it is important to determine if the stone is impacted at the ureterovesical junction or has already passed into the bladder. The purpose of this study was to determine if CT findings can be used to distinguish stones impacted at the ureterovesical junction from stones that have already passed into the bladder. SUBJECTS AND METHODS: From February 1, 1997, to January 31, 1998, 37 patients with acute flank pain underwent unenhanced CT studies in the supine position that showed stones in the region of the ureterovesical junction. To determine stone location, limited rescans were obtained with the patients in the prone position. The supine images were reviewed retrospectively by one of the authors, who was unaware of the findings of the prone scans. Forty-one stones were classified as being impacted at the ureterovesical junction or as having passed into the bladder. RESULTS: On CT, 23 stones were correctly classified as being impacted at the ureterovesical junction; nine stones were correctly classified as having passed into the bladder; and nine stones were incorrectly classified as being within the bladder. We calculated a sensitivity of 72%, a specificity of 100%, a positive predictive value of 100%, a negative predictive value of 50%, and an accuracy of 78% for CT in revealing stones impacted at the ureterovesical junction. CONCLUSION: If patients are imaged in the supine position only, unenhanced helical CT cannot reliably distinguish stones impacted at the ureterovesical junction from stones that have already passed into the bladder. A prone scan can be used to make this distinction.

Adolescent↗

Dosimetry studies with TLDs for stereotactic radiation techniques for intraocular tumours.

Between March 1993 and January 1997, stereotactic radiation techniques were used to irradiate 66 intraocular tumour patients with the Gamma Knife (Leksell Gamma Knife, model B unit) at the University of Vienna, Austria. This study investigates the dosimetry for stereotactic irradiation of ocular structures. For the dosimetry program KULA 4.4, Gamma Knife stereotactic irradiation of the eye represents an extreme frontal skull position. In addition, irradiation of the eye may be performed in the usual supine position in exceptional cases only. With the patient in the prone position, the dose planning program has to calculate with a significantly large number of single-beam extrapolations. In our first experiment we measured the isocentre dose for eight different gamma-angle positions, both in prone and supine positions, using TLD measurements in an Alderson head phantom. We found a maximum deviation of +/- 1.6% using these individually calibrated TLDs. In the second experiment we examined the dose cross profiles for the two most frequently used treatment positions (supine position, gamma = 65 degrees, and prone position, gamma = 140 degrees). For this purpose we implanted a specially designed TLD array into the orbit of a human cadaver head. We found excellent agreement of the dose values measured for the isocentre as well as the posterior part of the eye with orbit with deviations of less than -2.7%. However, for the anterior part of the eye, deviations between computer-generated calculations and the TLD measurements were found to range up to -30%. These differences were noticed both for supine and prone positions. For the Gamma Knife stereotactic irradiation of ocular tumours or pathologies, precautions should be taken to avoid significant underdosage in the anterior part of the radiation field.

Biophysical Phenomena↗

The Allan factor: a new model of mathematical interpretation of heart rate variability in stable coronary artery disease. Preliminary results.

INTRODUCTION: The current analysis of heart rate variability (HRV) is one of the noninvasive methods of cardiovascular system assessment. The quantitative characteristics of the RR interval sequence and its dynamics are still under development as regards measurement techniques and development of new HRV interpretation models. The practical clinical application of the standard measurements is still insufficient and improvement of sensitivity and specificity of HRV parameters is needed. AIM: To assess a novel mathematical model of HRV interpretation and compare it with standard HRV measurements for patients with stable coronary artery disease (CAD), based on the virtual instrumentation technique. METHODS: The study group consisted of 24 patients with CAD confirmed by coronary angiography and a control group of 15 volunteers. Short-term electrocardiographic signals were recorded by a computer system and analysed for estimation of several HRV descriptors in time, frequency and combined time-frequency domains. Calculations included standard HRV measures and the Allan factor, a parameter based on the Haar wavelet transform. RESULTS: None of the investigated measurements derived from power spectral analysis has shown a statistically significant difference between healthy controls and patients with CAD, with the exception of rMSSD (Wilcoxon test: supine position *p=0.0018, erect position p=0.0708; discriminant function analysis: supine position *p=0.0069, erect position p=0.7851). Compared with standard HRV variables, the Allan factor better discriminated patients with CAD from healthy subjects (Wilcoxon test: supine position *p=0.0172, erect position *p=0.0001; discriminant function analysis: supine position p=0.8962, erect position *p=0.0200). CONCLUSIONS: The observations related to the novel parameter based on combined time and frequency domains may provide better quantitative measurements of heart rate variability in patients with coronary artery disease and require further investigations to assess their sensitivity and specificity.

Adult↗

Effects of position changes on transcutaneous carbon dioxide tension in neonates with respiratory distress.

Routine neonatal care includes frequent position changes. Recent research has concluded that positions other than supine may result in beneficial physiologic responses. Specifically, several studies suggest that neonates may ventilate more effectively in a prone rather than in a supine position. This study tested the hypothesis that transcutaneous carbon dioxide tension (TcPCO2) would be lower in the prone than in the supine position in neonates with respiratory distress. Fourteen ventilated infants were studied. TcPCO2 was measured and recorded in prone, supine, and right-side-lying positions for each subject. There were no statistically significant differences in mean TcPCO2 values between the three positions (F = .45; df 2,39; P = .64). The relationship between TcPCO2 and PaCO2 values was stable (r = .88) during the studies. The results indicate that changing a neonate's position does not significantly alter transcutaneous carbon dioxide tension.

Blood Gas Monitoring, Transcutaneous↗

High-frequency oscillatory ventilation following prone positioning prevents a further impairment in oxygenation.

OBJECTIVE: The improvement in oxygenation with prone positioning is not persistent when patients with acute respiratory distress syndrome (ARDS) are turned supine. High-frequency oscillatory ventilation (HFOV) aims to maintain an open lung volume by the application of a constant mean airway pressure. The aim of this study was to show that HFOV is able to prevent the impairment in oxygenation when ARDS patients are turned back from the prone to the supine position. DESIGN: Prospective, comparative randomized study. SETTING: A medical intensive care unit. PATIENTS: Forty-three ARDS patients with a Pao2/Fio2 ratio <150 at positive end-expiratory pressure > or =5 cm H2O. INTERVENTIONS: After an optimization period, the patients were assigned to one of three groups: a) conventional lung-protective mechanical ventilation in the prone position (12 hrs) followed by a 12-hr period of conventional lung-protective mechanical ventilation in the supine position (CV(prone)-CV(supine)); b) conventional lung-protective mechanical ventilation in the supine position (12 hrs) followed by HFOV in the supine position (12 hrs) (CV(supine)-HFOV(supine)); or c) conventional lung-protective mechanical ventilation in the prone position (12 hrs) followed by HFOV in the supine position (CV(prone)-HFOV(supine) group). MEASUREMENTS AND MAIN RESULTS: Pao2/Fio2 ratio was higher at the end of the study period in the CV(prone)-HFOV(supine) group than in the CV(prone)-CV(supine) group (p < .02). Venous admixture at the end of the study period was lower in the CV(prone)-HFOV(supine) group than in the two other groups. CONCLUSIONS: HFOV maintained the improvement in oxygenation related to prone positioning when ARDS patients were returned to the supine position.

Aged↗

[The influence of lung volume and body position on pulmonary blood flow under hypoxic exposure].

We examined the changes in the electromagnetically measured left lower lobe blood flow (QLLL) when the left lower lobe (LLL) was exposed to alveolar hypoxia selectively under two different positions (supine and right lateral position in 18 dogs. QLLL/CO, Qs/Qt and other cardiopulmonary parameters were obtained during the following experimental sequence; 1) the whole lung ventilated with 100% O2 (control), 2) LLL collapsed and the remainder ventilated with 100% O2, 3) N2 expansion of LLL (N2 CPAP) and the remainder ventilated with 100% O2, 4) O2 expansion of LLL (O2 CPAP) and the remainder ventilated with 100% O2, and 5) The whole lung ventilated with 100% O2. In the supine position group (n = 9), both selective collapse and N2 CPAP of LLL caused QLLL/CO to decrease significantly (P less than 0.02) from control values (14.9 +/- 1.7%) to 10.6 +/- 0.9% and 11.9 +/- 1.6%, respectively. But there was no difference in QLLL/CO between collapse and N2 CPAP of LLL. In the right lateral position group (n = 9), hypoxic exposure of LLL caused no decrease in QLLL/CO from control values. But QLLL/CO during N2 CPAP (8.5 +/- 1.1%) decreased significantly than that during collapse (10.8 +/- 1.5%) (P less than 0.02). Qs/Qt during N2 CPAP (15.6 +/- 1.4%) also decreased significantly (P less than 0.05) from that during collapse (18.5 +/- 2.2%). We conclude that the difference of the changes in QLLL/CO under hypoxic exposure between supine and right lateral position was caused by hydrostatic pressure which influenced more during lateral position than during supine position.

Animals↗

Effectiveness of turning with unequal time intervals on the incidence of pressure ulcer lesions.

AIM: This paper reports a study investigating whether repositioning patients lying on a pressure-reducing mattress alternately for 2 hours in a lateral position and 4 hours in a supine position reduces the incidence of pressure ulcers in comparison with repositioning every 4 hours. BACKGROUND: Repositioning is commonly recognized as an effective preventive measure. Almost no research has been carried out so far on the necessary turning frequencies to prevent pressure ulcer lesions. The pressure is higher in a lateral than in a supine position. METHOD: A two-arm randomized controlled trial was conducted in 16 Belgian elder care nursing homes. Patients with non-blanchable erythema were randomly assigned to either an experimental or a control group. In the experimental group (n = 122), patients were repositioned alternately 2 hours in a lateral position and 4 hours in a supine position. In the control group (n = 113), patients were repositioned every 4 hours. The sitting protocol was identical in both groups. Pressure areas were observed daily and classified according to the four grades of the European Pressure Ulcer Advisory Panel. RESULTS: In the experimental group, 16.4% patients developed a pressure ulcer lesion (grade 2-4), while 21.2% did so in the control group. The incidence was not statistically significantly different between the two groups (P = 0.40). The severity (P = 0.65) and location (P = 0.19) of pressure ulcer lesions, and the time to developing them (P = 0.29) were also similar in both groups. No patient developed a pressure ulcer at the hips. A considerable number of patients changed from a lateral to a supine position between the turning intervals. CONCLUSION: More frequent repositioning on a pressure-reducing mattress does not necessarily lead to fewer pressure ulcer lesions and consequently cannot be considered as a more effective preventive measure.

Aged, 80 and over↗