PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tooth Cervix”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Prevalence and distribution of cervical dentin hypersensitivity in a population in Taipei, Taiwan.

The prevalence, distribution, and possible causal factors of cervical dentin hypersensitivity were studied in a population attending the Health Examination Center of National Taiwan University Hospital. A total of 780 patients were examined for the presence of cervical dentin hypersensitivity by means of a questionnaire and intraoral tests. There were 253 patients (32%) who claimed to have hypersensitive teeth at present and 90 patients (12%) who reported a history of hypersensitive teeth. The intraoral distribution of hypersensitivity showed that premolars and molars were the most common teeth sensitive to the air and probe stimuli, while the incisors were the least sensitive ones. The presence and history of dentin hypersensitivity were positively correlated with previous tooth-brushing and periodontal disease. Only a few of the patients who claimed to have dentin hypersensitivity had tried treatment with desensitizing tooth-pastes (11%) or sought professional help (5%).

Adult↗

Strain patterns in cervical enamel of teeth subjected to occlusal loading.

OBJECTIVES: This study was planned to investigate the variations in strains in enamel under different patterns of occlusal loading, using three-dimensional finite element analysis (3D FEA) and strain gage measurements in extracted teeth. METHODS: A 3D FEA model of a mandibular second premolar was used to investigate effects of occlusal load on enamel surface strains, particularly in response to oblique directions of cuspal loading. Point loads of 100 N were applied axially and at 45 degrees from the vertical on the buccal or lingual incline of the buccal cusp, either in the bucco-lingual plane or at varying mesio-distal angulations (up to +/- 20 degrees). Patterns of strain observed in the FEA model were confirmed experimentally using strain gages on extracted premolars mounted in a servohydraulic testing machine. RESULTS: Strains predicted from the FEA model were in excellent agreement with the strain gage measurements. Strains were concentrated near the cementoenamel junction (CEJ) regardless of load direction. A vertical load on the buccal cusp tip resulted in compressive strains on the buccal surface but small tensile strains in lingual cervical enamel. Strains resulting from oblique loads on buccal cusp inclines were complex and asymmetric, with either tension or compression occurring in any location depending on the site and angle of loading. SIGNIFICANCE: The magnitude, direction and character of strains in cervical enamel are highly dependent on patterns of loading. The asymmetric pattern of strains in buccal cervical enamel in response to oblique occlusal forces is consistent with the common clinical picture of asymmetric non-carious cervical lesions.

Analysis of Variance↗

Effect of stress on acid dissolution of enamel.

OBJECTIVES: This study was designed to measure the dissolution of buccal enamel of extracted teeth exposed to acid with or without simultaneous cyclic occlusal loading. METHODS: Twenty mandibular premolars were mounted in pairs in a servohydraulic testing machine, and immersed in 1% lactic acid (pH 4.5) or water. One tooth of each pair was subjected to cyclic loading (100 N at 2 Hz for 200,000 cycles), with the load applied at 45 degrees to the tooth axis on the buccal incline of the buccal cusp. The second tooth of each pair was immersed in acid but not subjected to load. Control teeth were immersed in water, with one tooth of each pair undergoing cyclic loading. Impressions of the teeth were taken before and after exposure to acid and occlusal loading, and a profiling system was used to measure the depth and volume loss of enamel on the buccal surface. RESULTS: The depth of enamel dissolved ranged from approximately 50-200 microm. In certain locations teeth undergoing cyclic loading during acid exposure showed greater volumetric loss than teeth not subjected to load. Loaded teeth showed a complex pattern of enamel dissolution; volumetric loss in the cervical third was greater than in the middle third, and was much greater in the mesiobuccal segment (under tension) than in the distobuccal segment (under compression). Unloaded teeth showed greater volumetric loss in the cervical third than in the middle third, with a uniform pattern of enamel dissolution from mesiobuccal to distobuccal aspects. SIGNIFICANCE: Enamel dissolution is increased significantly in sites subjected to cyclic tensile load.

Analysis of Variance↗

The effect of load cycling on the nanoleakage of dentin bonding systems.

OBJECTIVES: The purpose of this study was to evaluate the effects of load cycling on nanoleakage of occlusal flat surface or cervical restorations bonded with three self-etching priming systems and a single bottle system. METHODS: The dentin bonding systems used in this study were Clearfil SE Bond, Unifil Bond, Prompt L-Pop and Single Bond. Flat occlusal dentin surfaces and cervical cavities from extracted human molars were bonded with one of the dentin bonding systems. After load cycling of 90N for 5000 cycles, samples were immersed in a 50% w/v solution of silver nitrate for 24h, and exposed to photodeveloping solution for 8h. Specimens were sectioned, mounted on stubs, carbon-coated and observed in a Field Emission-SEM using backscattered electron mode. One-way ANOVA was used for statistical analysis of the leakage scores. RESULTS: FE-SEM images showed that samples subjected to load cycling had leakage patterns similar to non-load-cycled samples for all dentin bonding systems. Load cycling did not affect leakage lengths in any system. Prompt L-Pop had greater silver deposition and leakage score than the other systems. SIGNIFICANCE: The dentin bonding systems tested were unable to prevent nanoleakage, and the extent of nanoleakage was not increased by load cycling.

Analysis of Variance↗

Micro-tensile bond strengths to sclerotic dentin using a self-etching and a total-etching technique.

OBJECTIVES: To evaluate the in vitro regional micro-tensile bond strengths of a self-etching/self-priming adhesive system to sclerotic dentin, in the absence or presence of phosphoric acid conditioning. METHODS: Naturally-occurring, non-carious cervical lesions on extracted premolars were hand-cleaned with a slurry of pumice and chlorhexidine, then bonded without further cavity preparation. One group was bonded using Clearfil Liner Bond 2V (Kuraray Co. Ltd., Osaka, Japan). The other group was first conditioned with K-etchant; 40% phosphoric acid gel (Kuraray) prior to the application of the self-etching primer. Artificially prepared wedge-shaped cavities were also made in sound premolars and bonded with the two methods as controls. Resin composite build-ups were made using Clearfil Protect Liner F and AP-X resin composite (Kuraray). After storage in water for 24h, the teeth were sectioned into 0.7 x 0.7 mm composite-dentin beams along the occlusal and gingival walls, and at the apex of the lesions. The use of two conditioning methods, two substrate types, and three different locations yielded 10-14 beams for each of the 12 groups. After testing for the microTBS, representative beams that were stressed to failure were examined with SEM. Remaining fractured beams were demineralized and processed for TEM examination. Statistical analysis was performed using a three-way ANOVA and Student-Newman-Keuls tests. RESULTS: Regardless of the conditioning methods, bond strengths to sound dentin were significantly higher than to sclerotic dentin (P< 0.05). With sclerotic dentin, there was no significant difference for the conditioning methods used, except that K-etchant significantly improved the bond strength at the gingival aspect of the lesions. Fractographic analysis revealed that the self-etching primer could not etch beyond the surface hypermineralized layer of sclerotic dentin. Interfacial failure occurred along the surface of the mineralized intermicrobial matrix and/or hypermineralized layer. With the use of phosphoric acid, a hybrid layer was only seen when the surface layers were thin. Incompletely removed sclerotic casts were evident in both groups. SIGNIFICANCE: Removal of the surface layers of sclerotic dentin and/or conditioning with stronger acids may be beneficial to obtain stronger bonding to sclerotic dentin.

Acid Etching, Dental↗

Ultimate tensile strength of tooth structures.

OBJECTIVE: This study determined the ultimate tensile strength (UTS) of enamel (E), dentin (D) and dentin-enamel junction (DEJ) using the microtensile technique. It was hypothesized that the UTS of dental structures varies according to location and nature. METHODS: Intact occlusal enamel surfaces from extracted human third molars were etched with 37% phosphoric acid and bonded with a one-bottle adhesive system. The bonded occlusal surfaces received a resin composite build-up and teeth were serially, vertically sectioned into several 0.7 mm thick slabs. Each slab was then trimmed to a dumbbell-shaped specimen with irrigated diamond burs to reduce the cross-sectional area to approximately 0.5 mm2 at E, D or DEJ. E was tested according to its prismatic orientation (parallel, EP; and transversally, ET) and D as function of depth (superficial, DS; middle, DM and deep, DD). Specimens were tested in tension in an Instron testing machine at 0.5 mm/min. Results were analyzed by one-way ANOVA and Duncan's Multiple Range test. RESULTS: UTS mean values (N = 20) were, MPa (SD): DEJ, 46.9 (13.7)b; EP, 42.1 (11.9)b; ET, 11.5 (4.7)d; DS, 61.6 (16.2)a; DM, 48.7 (16.6)b and DD, 33.9 (7.9)c. Enamel stressed transversally to its prismatic orientation was significantly weaker (p < 0.05) Dentin depth significantly affected its UTS (p < 0.05) DEJ presented UTS that was similar to EP and DM (p > 0.05) SIGNIFICANCE: The UTS of dental structures varies according to its nature and location.

Analysis of Variance↗

Resistance of cementum in Class II and V cavities to penetration by an adhesive system.

OBJECTIVES: As the cervical margin located in cementum-dentin is still the most unpredictable area of an adhesive resin restoration, the aim of this investigation was to evaluate the morphology of the cementum layer at the cervical margins of Class V and Class II cavities and the impregnability of this layer to resin bonding systems. METHODS: Three different types of in vitro investigations of the cervical margins were performed by scanning electron microscopy: 1) direct anatomical observation of conditioned cavities; 2) observation of resin replicas; and 3) observation of resin infiltration. During direct observation, the presence of opened tubules was evaluated; in the resin replicas, the presence of resin tags and their density were observed; in the observation of resin infiltration, the presence of an acid-resistant interdiffusion was investigated. RESULTS: From direct observation, cut tubules were seen 200 microns from the cervical margin. After treatment with a dentin bonding system, the outer layer was infiltrated by the resin. In the resin replica, the presence of resin tags was detectable 150-200 microns from the margin. In Class II samples, the presence of an outer layer at the cervical margin, which could not be identified as bulk dentin or cementum, was clearly detectable by both direct and indirect observation. In the Class V samples, the border between this layer and bulk dentin was less evident. SIGNIFICANCE: The presence of a cementum layer of approximately 150-200 microns at the cervical margins of cavities may pose a serious clinical problem for reliable bonding. Although in the present study the observation of a zone of resin-impregnated cementum may confirm the improvement obtained with the last generation of hybridizing dentin bonding systems, the effectiveness of the bond is still unclear.

Composite Resins↗

Microleakage and SEM interfacial micromorphology of amalgam restorations using three adhesive systems.

OBJECTIVE: This study evaluated the microleakage and interfacial micromorphology of Class V cervical amalgam restorations lined with OptiBond, AElitebond, or Panavia 21. METHODS: Unlined amalgams served as control. Cavities were treated with each dentin bonding system according to the manufacturers' instructions and restored with Tytin non-gamma 2 spherical amalgam. After one week of storage in tap water at 37 degrees C, the specimens were thermocycled (1000 cycles, 6-60 degrees C, 30s dwell time). Microleakage was assessed by means of basic fuchsin dye penetration and recorded according to an ordinal scale. RESULTS: None of the systems tested in this study completely eliminated microleakage. Kruskal-Wallis one-way ANOVA and Mann-Whitney U test found that on the occlusal wall, Panavia 21 and the control group had the least leakage (P<0.05). No statistically significant differences were found at dentin margins (P>0.05). Wilcoxon matched pairs signed rank test found that Panavia 21 and the control group had less leakage at the occlusal than at the dentin margins (P<0.05); when AElitebond and OptiBond groups were evaluated, microleakage at the enamel and at the dentin margins was similar for each group. With the adhesive systems, perhaps the hydrophilic bonding agents incorporated the dye during specimen immersion and/or sectioning. CONCLUSIONS: The use of adhesives may not be as worthy as resin cements for sealing and bonding amalgam restorations to enamel and dentin.

Adhesives↗

Marginal integrity of large compomer Class II restorations with cervical margins in dentine.

OBJECTIVES: The aim of the present study was to investigate the marginal integrity of total-bond Dyract AP restorations in large Class II restorations with cervical margins in dentine. The efficacy of a new non-rinse conditioner and the effect of beveling the enamel margins were also studied. METHODS: Large MOD cavities with cervical margins located 1mm below the CEJ were prepared in 48 extracted human molars. Six groups (n=8) were filled using a total-bond technique with Spectrum TPH or Dyract AP or a sandwich technique with Dyract in combination with Spectrum TPH. For Dyract AP total-bond restorations, a new non-rinse conditioner was tested vs. a total-etch with 36% phosphoric acid in beveled and butt-joint cavities. After water storage for 21 days and thermocycling (2000x, 5-55 degrees C), replicas were produced for quantitative marginal analysis in the SEM. Afterwards, teeth were immersed in 0.5% basic fuchsin for 24h and dried. Percent dye penetration over the total margin length was analysed in three layers using a sequential grinding technique. Statistical analysis was performed with non-parametric tests and the Bonferroni correction for multiple comparisons at p<0.05. RESULTS: All restoration types showed microleakage. On cervical margins in dentine, Dyract AP restorations showed better marginal adaptation than Spectrum TPH total-bond restorations (marginal openings (MO), median 33.8 vs. 79.6%), but were inferior to Dyract/Spectrum TPH sandwich restorations (MO: 0. 0%). The non-rinse conditioner improved the marginal adaptation of Dyract AP restorations in dentine (MO: 4.7 vs. 38.4%, p=0.0206 for beveled cavities, 12.2 vs. 33.8%, p=0.0238, for butt-joint cavities) and yielded similar results in enamel margins provided that enamel margins were beveled. Beveling of enamel significantly reduced the occurrence of enamel microcracks. CONCLUSIONS: The use of a non-rinse conditioner in combination with Dyract AP may improve the marginal adaptation of Class II restorations compared to composite restorations. The sandwich technique with Dyract results in better marginal adaptation in cervical dentine compared to all other restorative techniques tested in this study. However, microleakage cannot predictably be prevented with the sandwich technique.

Acid Etching, Dental↗

Splints and stress transmission to teeth: an in vitro experiment.

OBJECTIVE: To determine the influence of hard and soft splints with two thicknesses on the stress transmission to the tooth supporting the splint and the opposite tooth. METHODS: Continuous vertical forces up to 500N were applied to two opposite first molar phantom teeth using a universal loading machine. Deformation was detected by strain gauges attached to the cervical area of the buccal and lingual aspects of the lower tooth. Strain, as a function of force, was collected and the slope, defined as the compliance (in microS/N) of the system, was calculated. RESULTS: The highest compliance was found with hard splints. When splints were constructed on the upper molar, the highest compressive compliance was registered on the buccal side (2.8 microS/N) and tension compliance on the lingual side (-0.35 microS/N). When constructed on the lower tooth, the opposite was found. Soft splints resulted in compression on both the buccal and lingual sides when adjusted to the upper or lower tooth. A higher compliance was found on the buccal side (1.26 microS/N), while on the lingual side, the values varied (0.48-0.78 microS/N). CONCLUSIONS: Soft splints are more efficient in protecting teeth against the damage of bending forces although there is an increase of compression forces. The tooth opposing a hard splint is exposed to a higher risk of bending forces.

Analysis of Variance↗

An ultrastructural study of the application of dentine adhesives to acid-conditioned sclerotic dentine.

OBJECTIVE: This in vitro study examined the ultrastructure of resin-infiltrated sclerotic dentine following the application of a self-etching primer, with or without the adjunctive use of phosphoric acid pre-conditioning. MATERIALS AND METHODS: Non-carious, natural cervical sclerotic lesions were hand-cleaned with a slurry of pumice and chlorhexidine and bonded without further cavity preparation. One group was bonded using Clearfil Liner Bond 2V (Kuraray Co. Ltd, Osaka, Japan) alone. Specimens from the other group were pre-conditioned with K-etchant (40% phosphoric acid gel, Kuraray) prior to the application of the same self-etching primer. Artificially prepared wedge-shaped lesions were also made in sound bicuspids, bonded using the two methods, and used as controls for the two groups. For SEM examination, each specimen was cryofractured into two halves through a pre-formed slit made on the lingual surface, after the respective conditioning treatment. Different locations within the lesions were examined after rinsing of the phosphoric acid/self-etching primer and specimen dehydration. For TEM investigation, specimens were bonded with the adhesive. Both demineralised and undemineralised ultrathin sections were prepared from the occlusal, gingival and deepest part of the wedge-shaped bonded lesions following specimen fixation, dehydration and resin embedding. RESULTS: A hypermineralised surface layer was present on the surface of etched sclerotic dentine. This layer was thicker in the deepest part of the natural lesions, where bacterial colonisation of the lesion surface was also apparent. Both treatment protocols were unable to effectively dissolve sclerotic casts that occluded the dentinal tubules. Depending upon the thickness of the surface layers at different locations in the natural lesion, self-etching primer treatment alone resulted in reduction of the thickness of the authentic hybrid layer (i.e. hybridised intertubular dentine). This was also true of phosphoric acid pre-conditioning along the deepest part of the natural lesions. Within this region, intertubular dentine completely devoid of an authentic hybrid layer could be seen in both treatment groups. Resin tags were also sparsely observed in such regions. CONCLUSIONS: Adhesive strategies that rely mostly on micromechanical retention alone may be compromised by the sporadic absence of the hybrid layer and resin tags in sclerotic dentine. Based on the ultrastructural features presented, it is further speculated that adaptive strategies such as removal of the surface layers and extended etching time may not be completely effective in improving bonding efficacy in highly sclerotic dentine. Interdisciplinary research should be continued to develop alternative procedures for bonding resins equally well to sound and sclerotic dentine.

Acid Etching, Dental↗

Marginal quality and microleakage of adhesive class V restorations.

OBJECTIVES: The aim of this in vitro study was to determine the marginal quality and microleakage of composite resin class V restorations. METHODS: Standardized mixed class V cavities (diameter: 4mm, depth: 2mm) with half of the finish lines limited within dentin were cut in 90 freshly extracted human molars and randomly assigned to nine groups (n=10). After etching enamel and dentin, the cavities were restored with nine different restorative systems (Syntac Sprint/Tetric Ceram=SS, Syntac Single-Component/Tetric Ceram=SC, Onestep/Aeliteflo=OS, Aquaprep+Onestep/Aeliteflo=OA, Prime & Bond 2.1/TPH=PB, Optibond Solo/Prodigy=OP, Singlebond/Z100=SB, Tenure Quik/Marathon=TQ, Solobond M/Arabesk=SM) using a wet-bonding procedure. After finishing and polishing, the teeth were stored for 24h in distilled water at 37 degrees C before they were subjected to thermocycling (5/55 degrees C, 1000x). Epoxy replicas were made for margin analysis in the SEM. Specimens were stained in methylene blue, sectioned, and evaluated for microleakage. Dye penetration was scored on a 0-3 ordinal scale. RESULTS: Statistical analysis (Kruskal-Wallis H-test, Mann-Whitney U-test) revealed significant differences (P<0.05) among the groups at dentin and enamel margins for the microleakage scores as well as for the results of the quantitative SEM margin analysis. SC revealed a significantly higher percentage of perfect margins in the SEM than OS and SM in enamel and dentin, respectively. OA exhibited significantly more leakage in enamel than all other groups. CONCLUSIONS: None of the tested restorative systems achieved a perfect seal in dentin and enamel of mixed class V cavities. Marginal quality and sealing ability of adhesive systems to dentin, using a wet-bonding procedure, is still inferior compared with enamel margins.

Barium Compounds↗

Analysis on the nature of thermally induced deformation in human dentine by electronic speckle pattern interferometry (ESPI).

OBJECTIVE: To examine the in-plane and out-of-plane response of human dentine to thermal loads in real time. METHODS: An Electronic Speckle Pattern Interferometry (ESPI) system sensitive to both the in-plane and out-of-plane displacements was configured and used in conjunction with an advanced fringe processing technique. Specimens were prepared from freshly extracted lower central incisor teeth and were separately mounted on a thermal block to apply thermal loads from room temperature (25 degrees C) to 60 degrees C. The real time speckle patterns were acquired using a digital camera. These digital fringe patterns were subjected to further image processing to enhance the quality of fringes. The resultant images were later analyzed to study the out-of-plane and in-plane displacement gradients in the facio-lingual plane of the dentine. RESULTS: The out-of-plane deformations were observed in the plane perpendicular to the long axis of the tooth, while the in-plane deformations occurred in the plane parallel to the long axis of the tooth. CONCLUSION: The ESPI analysis revealed whole-field and distinct thermal response in human dentine in-plane and out-of-plane. The cervical dentine experienced distinct and conspicuous displacement to the temperature changes.

Adult↗

Glass ionomer microleakage from preparations by an Er/YAG laser or a high-speed handpiece.

OBJECTIVE: The purpose of this study was to compare microleakage of glass ionomer materials (GIC) using two different modes of cavity preparation: a high-speed hand piece and an erbium/yttrium-aluminum-garnet (Er/YAG) laser. METHODS: Eighty caries free permanent molar teeth had class V preparations cut on both the buccal and lingual surfaces. The high-speed hand piece was used to prepare a class V cavity preparation on the buccal surface and an Er/YAG laser was used to prepare a class V cavity preparation on the lingual surface. GIC or resin modified GIC was used as the restorative material. The teeth were thermocycled for 7000 cycles, placed in 2% basic fushin for 24h, sectioned in the center of each restoration, and analyzed under a stereomicroscope. RESULTS: There was no statistical difference in microleakage between the two modes of cavity preparations. The gingival margins had more microleakage than the occlusal margins for both GIC materials and the resin modified GIC showed significantly more leakage than the conventional GIC. CONCLUSIONS: The Er/YAG laser provided an equivalent method of tooth removal when evaluated for microleakage of GIC materials compared to a high-speed hand piece.

Aluminum Silicates↗

Marginal and internal adaptation of class II restorations after immediate or delayed composite placement.

Direct class II composite restorations still represent a challenge, particularly when proximal limits extend below the CEJ. The aim of this in vitro study was to evaluate the influence of the type of adhesive and the delay between adhesive placement and composite insertion on restoration adaptation. Direct class II MOD box-shaped composite restorations (n=8 per group) were placed on intact human third molars, with proximal margins 1mm above or under CEJ. All cavities were filled with a horizontal layering technique, immediately after adhesive placement (IP) or after a 24h delay (DP). A filled three-component adhesive (OptiBond FL: OB) and a single-bottle, unfilled one (Prime & Bond 2.1: PB) were tested. Marginal adaptation was assessed before and after each phase of mechanical loading (250000 cycles at 50 N, 250000 cycles at 75 N and 500000 cycles at 100 N); internal adaptation was evaluated after test completion. Gold-plated resin replicas were observed in the SEM and restoration quality evaluated in percentages of continuity (C) at the margins and within the internal interface, after sample section. Adaptation to beveled enamel proved satisfactory in all groups. After loading, adaptation to gingival dentin degraded more in PB-IP (C=55.1%) than PB-DP (C=86.9%) or OB-DP (C=89%). More internal defects were observed in PB samples (IP: C=79.2% and DP: C=86.3%) compared to OB samples (IP: C=97.4% and DP: C=98.3%). The filled adhesive (OB) produced a better adaptation than the 'one-bottle' brand (PB), hypothetically by forming a stress-absorbing layer, limiting the development of adhesive failures. Postponing occlusal loading (such as the indirect approach) improved also restoration adaptation.

Acetone↗

The prevalence of dentine hypersensitivity in a hospital clinic population in Hong Kong.

OBJECTIVES: Dentine hypersensitivity is a common clinical finding with a wide variation in prevalence values. The aim of this study was to establish the prevalence of dentine hypersensitivity and to examine some associated aetiological factors in a cross-sectional study of patients visiting the Periodontology and Oral Hygiene Clinic at Prince Phillip Dental Hospital, Hong Kong over a three-week period. METHODS: 226 patients were examined over a three-week period using a triple syringe to administer a blast of cold air to confirm the diagnosis of dentine hypersensitivity. Additional factors such as smoking habits, initiating stimuli, gingival recession and cervical tooth surface loss were noted. RESULTS: 153 patients were diagnosed as having dentine hypersensitivity, giving a prevalence figure of 67.7%. The commonest teeth affected were the lower incisors and the commonest initiating factor was cold drinks. CONCLUSIONS: The prevalence of dentine hypersensitivity in a hospital periodontology clinic population in Hong Kong was 67.7%.

Adolescent↗

Occluding effect of dentifrices on dentinal tubules.

OBJECTIVES: The objective of this study was to evaluate the tubule occluding ability of three commercial available dentifrices (Sensodyne, Emoform and Sorriso) by Scanning Electron Microscopy. METHODS: Fifty cervical areas from buccal and lingual surfaces of sound third human molars were used. Cervical enamel was wet abraded to expose flat dentin surfaces and further polished with diamond pastes. Specimens were randomly divided into five groups (n=10): G1-no brushing; G2-brushing without dentifrice; G3-brushing with Sensodyne; G4-brushing with Emoform; G5-brushing with Sorriso. Brushed specimens were treated for 4 min per day, for 7 days in a toothbrushing machine. Specimens were prepared and observed under SEM for calculation of the percentage of occluded tubules. In addition, slurries of toothpastes were analyzed by X-ray microanalysis. Data were statistically analyzed by ANOVA and Tukey test (p<0.05). RESULTS: Means of occluded tubules in descending order were: G5-98.83+/-3.31% (a), G4-96.02+/-5.24% (a), G3-80.12+/-24.65% (a), G1-37.31+/-24.22% (b); G2-22.92+/-15.19% (b). The three tested dentifrices produced increased dentinal occlusion as compared to controls (p<0.05) but equivalent occlusion among each other. Calcium from calcium-carbonate abrasive was identified in all dentifrices. CONCLUSIONS: Results indicated that the use of all dentifrices occluded tubules more than no brushing and brushing without dentifrices groups. Thus, the tested dentifrices seem effective for desensitization by tubule occlusion.

Analysis of Variance↗

Physical properties and gap formation of light-cured composites with and without 'softstart-polymerization'.

OBJECTIVES: Recently it has been pointed out that light-initiated prepolymerization at low intensity followed by a post-light-cure at full intensity ('softstart-polymerization') may lead to light-cured composite fillings with improved marginal adaptation. The aim of this study was to examine the influence of this procedure with different initial cure conditions on physical material properties like flexural modulus, flexural strength and Vickers microhardness of different composites. Additionally, an in vitro study was carried out to investigate the influence of different initial cure conditions on the marginal quality of composite restorations in cases of Class V cavities with a cemento-enamel junction. METHODS: Physical properties of composite materials Tetric (Vivadent, Liechtenstein) and Charisma (Kulzer, Germany) were evaluated. Three hundred specimens were made for the flexural tests performed similar to EN 24049:1993. Microhardness was measured with a Vickers indenter. For the in vitro study of Class V composite fillings, cavities of 32 extracted teeth were filled with Tetric and analysed by quantitative marginal gap analysis and dye penetration test before and after thermocycling. RESULTS: The results indicate that initial cure with decreased light intensity followed by final cure with high light intensity has no influence on microhardness and increases flexural modulus and flexural strength. With the low-level initial cure/high-level final cure regime the marginal integrity was significantly better compared with the high light intensity curing system. CONCLUSION: Therefore, initial cure with low light intensity followed by final cure with high light intensity significantly improves the marginal integrity of light-cured composite fillings and also the material properties.

Chemical Phenomena↗