PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 415 records · Page 23Linked to original sources

Photopatterning of antibodies on biosensors.

The immobilization of biomolecules on surfaces in defined micropatterns has become increasingly important for the development of new diagnostic devices and high-throughput genetic and drug screening protocols. We describe the synthesis and testing of thiol-reactive, photoactivatable linkers that will permit laser micropatterning or photolithographic patterning of surfaces. In these linkers, a benzophenone photophore is tethered through a variable-length poly(ethylene glycol) hydrophilic spacer to a maleimide group. Spacers containing one to five ethylene glycol units were examined. Antibodies were photoimmobilized on polystyrene waveguides and the resulting biosensors were used for fluorescence immunoassays. The spacer with five ethylene glycol units optimally decreased the steric interactions among large molecules (antibodies and antigens) and increased binding capacity and response rate of the biosensor. Two different sandwich assay protocols were examined. In the first, the antigen and fluorescently labeled second antibody were added sequentially to the biosensor ("stepwise"). In the second, the antigen and antibody were premixed before injection into the biosensor ("premixed"). The stepwise protocol gave a significantly higher response than that of the premixed protocol. Although the premixed protocol is more convenient, the stepwise protocol provides enhanced sensitivity.

Antibodies↗

Reversible surface thiol immobilization of carboxyl group containing haptens to a BIAcore biosensor chip enabling repeated usage of a single sensor surface.

We describe a reversible immobilization method for carboxyl group containing haptens that makes the repeated usage of a BIAcore biosensor chip possible. Haptens which are immobilized according to the surface thiol method can be removed completely from the sensor surface again by a reducing step. In the first part of our study, analogues of the herbicides 2,4-dichlorophenoxyacetic acid and 2,4,5-trichlorophenoxyacetic acid were immobilized in succession to a biosensor surface of a BIAcore surface plasmon resonance instrument according to the thiol coupling method. Direct kinetic analysis of these ligands to a polyclonal anti-2,4-dichlorophenoxyacetic acid antibody were performed using these biosensor surfaces. In the second part of the study, different amounts of 2,4-dichlorophenoxyacetic acid were sequentially immobilized onto the same biosensor surface in order to generate a calibration plot for 2,4-dichlorophenoxyacetic acid. Using this plot, the quantitative detection of the herbicide down to a concentration of 0.1 microg/mL, the maximum admissible concentration of pesticides in drinking water, is possible.

2,4,5-Trichlorophenoxyacetic Acid↗

Use of a biosensor with surface plasmon resonance detection for the determination of binding constants: measurement of interleukin-6 binding to the soluble interleukin-6 receptor.

The interaction of recombinant human interleukin-6 (IL-6) with the soluble extracellular form of its receptor (sIL-6R) has been characterized by the application of expressions developed for quantitative affinity chromatography to results obtained with a biosensor based on surface plasmon resonance detection. First, the interaction of sIL-6R with IL-6 covalently attached to the biosensor-chip was characterized from the dependence of the surface plasmon resonance response upon the concentration of receptor injected into the biosensor. A binding constant for the interaction between sIL-6R and IL-6 was then determined from the biosensor response observed for mixtures of IL-6 and receptor--a procedure that is shown to provide unequivocal characterization of the competing reaction, irrespective of the model used to describe the biphasic interaction between partitioning receptor and immobilized IL-6. A binding constant of 5 x 10(7) M-1 has been obtained for the interaction of sIL-6R with two equivalent and independent sites on an essentially dimeric IL-6 preparation produced using the pUC vector system, and also for the interaction of sIL-6R with a monomeric IL-6 preparation that was univalent in its interaction with receptor.

Amino Acid Sequence↗

Flow injection amperometric enzyme biosensor for direct determination of organophosphate nerve agents.

A flow injection amperometric biosensor for the determination of organophosphate nerve agents was developed. The biosensor incorporated an immobilized enzyme reactor that contains the enzyme organophosphorus hydrolase covalently immobilized on activated aminopropyl controlled pore glass beads and an electrochemical flow-through detector containing carbon paste working electrode, a silver/silver chloride reference electrode, and stainless steel counter electrode. The organophosphorus hydrolase catalyzed the hydrolysis of organophosphate with nitrophenyl substituent to generate p-nitrophenol which is then detected downstream electrochemically at the carbon paste electrode poised at 0.9 V vs the reference electrode. The amperometric response of the biosensor was linear up to 120 microM and 140 microM, with lower detection limits of 20 nM and 20 nM, for paraoxon and methyl parathion, respectively. The response was very reproducible (RSD 2%, n = 35) and stable for over 1 month when the immobilized enzyme column was stored at 4 degrees C. Each assay took ca. 2 min giving a sample throughput of 30 h(-1). The applicability of the biosensor to monitor paraoxon and methyl parathion in distilled water and simulated well water was demonstrated.

Aryldialkylphosphatase↗

The application of biosensors to fresh produce and the wider food industry.

The inherent specificity, selectivity, and adaptability of biosensors make them ideal candidates for use throughout the food industry. Potential applications within the supply chain range from testing of foodstuffs for maximum pesticide residue verification through to the routine analysis of analyte(s) concentrations, such as, glucose, sucrose, alcohol, etc., which may be indicators of food quality/acceptability. Biosensor formats include simple "one-shot" disposable devices that can be used either in the field or integrated into more sophisticated laboratory instruments. Until now, the main impact of these devices has been in the medical diagnostics field. However, with ongoing technical development, the food industry will be one of the prime beneficiaries of biosensor technology in the future. This report assesses the current and future trends in the application of biosensors to fresh produce and the wider food industry, focusing on both potential and current target analytes that are fundamental to fresh produce quality, traceability, and safety.

Acoustics↗

Carbon paste biosensor based on crude soybean seed hull extracts for phenol detection.

In this study, a novel biosensor based on enzyme extracts from soybean seed hulls has been prepared, which demonstrated promising results in the detection of hydrogen peroxide and phenol. The biosensor preparation is straightforward and inexpensive, and the response time is 50 s. The optimum conditions of pH and temperature are a pH of 7.4 and a temperature of 20 degrees C. Contrary to expectations, the biosensor showed narrow pH and temperature optimums. The effects of enzyme loading and type of mediator were also investigated. The biosensor showed a linear response up to 500 microM phenol.

Biosensing Techniques↗

Comparison among differential pulse voltammetry, amperometric biosensor, and HPLC/DAD analysis for polyphenol determination.

Polyphenols are widespread in vegetables and fruits. They can play an important role in human diet and health, and they influence the sensorial properties of many foods, and act as natural antioxidants. This study was conducted using HPLC/DAD, tyrosinase biosensor, and differential pulse voltammetry (DPV) analyses to detect polyphenolic compounds in natural complex matrices. The analyses were applied to a series of both standards and natural extracts derived from grape, olives, and green tea. The pure compounds include phenolic acids, flavones, flavonols, catechins, tannins, and oleuropein. HPLC/DAD, DPV, and the biosensor approach were used as independent analytical techniques. Bare graphite screen-printed electrodes were employed in DPV and in the biosensor analysis. The most accurate data were obtained by HPLC/DAD analysis, while the DPV approach using screen-printed electrodes could represent a quick screening method for the determination of polyphenols in natural extracts. Use of the biosensor for the analysis of complex matrices needs further study in order to improve its performance.

Biosensing Techniques↗

Multilayer assembly of Prussian blue nanoclusters and enzyme-immobilized poly(toluidine blue) films and its application in glucose biosensor construction.

A multilayered glucose biosensor via sequential deposition of Prussian blue (PB) nanoclusters and enzyme-immobilized poly(toluidine blue) films was constructed on a bare Au electrode using electrochemical methods. The whole configuration of the present biosensor can be considered as an integration of several independent hydrogen peroxide sensing elements. In each sensing element, the poly(toluidine blue) film functioned as both the supporting matrix for the glucose oxidase immobilization and the inhibitor for the diffusion of interferences, such as ascorbic acid and uric acid. Meanwhile, the deposited Prussian blue nanocluster layers acts as a catalyst for the electrochemical reduction of hydrogen peroxide formed from enzymatic reaction. Performance of the whole multilayer configuration can be tailored by artificially arranging the sensing elements assembled on the electrode. Under optimal conditions, the biosensors exhibit a linear relationship in the range of 1 x 10(-4) to 1 x 10(-2) mol/L with the detection limit down to 10(-5) mol/L. A rapid response for glucose could be achieved in less than 3 s. For 1 mM glucose, 0.5 mM acetaminophen, 0.2 mM uric acid, and 0.1 mM ascorbic acid have no obvious interferences (<5%) for glucose detection at an optimized detection potential. The present multilayered glucose biosensor with a high selectivity and sensitivity is promising for practical applications.

Biosensing Techniques↗

Novel conducting polymer electrolyte biosensor based on poly(1-vinyl imidazole) and poly(acrylic acid) networks.

Biosensor construction and characterization studies of poly(acrylic acid) (PAA) and poly(1-vinyl imidazole) (PVI) complex systems have been carried out. The biosensors were prepared by mixing PAA with PVI at several stoichiometric ratios, x (molar ratio of the monomer repeat units). The enzyme, invertase, was entrapped in the PAA/PVA interpenetrating polymer networks during complexation. Modifications were made on the PAA/PVI conducting polymer electrolyte matrixes to improve the stability and performance of the polymer electrolyte-based enzyme biosensor. The maximum reaction rate (V(max)) and Michaelis-Menten constant (K(m)) were investigated for the immobilized invertase. The temperature and pH optimization, operational stability, and shelf life of the polymer electrolyte biosensor were also examined.

Acrylic Resins↗

Peptide nucleic acids and biosensor technology for real-time detection of the cystic fibrosis W1282X mutation by surface plasmon resonance.

In this paper we demonstrate that peptide nucleic acids (PNAs) are excellent probes able to detect the W1282X point mutation of the cystic fibrosis (CF) gene when biospecific interaction analysis (BIA) by surface plasmon resonance (SPR) and biosensor technologies is performed. The results reported here suggest that BIA is an easy, fast, and automatable approach for detecting mutations of CF, allowing real-time monitoring of hybridization between 9-mer CF PNA probes and target biotinylated PCR products generated from healthy, heterozygous subjects and homozygous W1282X samples and immobilized on streptavidin-coated sensor chips. This method is, to our knowledge, the first application of PNAs, BIA, and SPR to a human hereditary mutation, and demonstrates the feasibility of these approaches for discriminating between normal and mutated target DNA. We like to point out that the procedure described in this paper is rapid and informative; results are obtained within a few minutes. This could be of great interest for molecular pre-implantation diagnosis to discriminate homozygous CF embryos from heterozygous and healthy embryos. Other advantages of the methodology described in the present paper are (a) that it is a nonradioactive methodology and (b) that gel electrophoresis and/or dot-spot analysis are not required. More importantly, the demonstration that SPR-based BIA could be associated with microarray technology allows us to hypothesize that the method described in the present paper could be used for the development of a protocol employing multispotting on SPR biosensors of many CF-PCR products and a real-time simultaneous analysis of hybridization to PNA probes. These results are in line with the concept that SPR could be an integral part of a fully automated diagnostic system based on the use of laboratory workstations, biosensors, and arrayed biosensors for DNA isolation, preparation of PCR reactions, and identification of point mutations.

Biosensing Techniques↗

Optical biosensors in drug discovery.

Optical biosensors that exploit surface plasmon resonance, waveguides and resonant mirrors have been used widely over the past decade to analyse biomolecular interactions. These sensors allow the determination of the affinity and kinetics of a wide variety of molecular interactions in real time, without the need for a molecular tag or label. Advances in instrumentation and experimental design have led to the increasing application of optical biosensors in many areas of drug discovery, including target identification, ligand fishing, assay development, lead selection, early ADME and manufacturing quality control. This article reviews important advances in optical-biosensor instrumentation and applications, and also highlights some exciting developments, such as highly multiplexed optical-biosensor arrays.

Animals↗

Flow-injection detector incorporating a screen-printed disposable amperometric biosensor for monitoring organophosphate pesticides.

The construction of a wall-jet flow cell, which houses a screen-printed amperometric pesticide biosensor, together with a complete flow-injection system, is described. This system was initially employed in studies to stabilise the enzyme acetylcholinesterase (AChE), which was immobilised on a cobalt phthalocyanine screen-printed carbon electrode to form a biosensor. A combination of dextran sulfate and lactitol, and carbodiimide for enzyme immobilisation, resulted in biosensor lifetimes of at least 76 d (at 37 degrees C). Flow-injection and biosensor conditions were optimised, then the system was evaluated by monitoring the model organophosphate pesticides (OP) dichlorvos and paraoxon. The detection limits were 7 x 10(-11) mol dm-3 (for 1 U of AChE) and 4 x 10(-11) mol dm-3 (for 0.05 U of AChE), respectively, which are better than for other electrochemical methods. Initial evaluations on two river water samples have been carried out to test the validity of the system for OP determination in field samples.

Biosensing Techniques↗

An electrochemiluminescence-based fibre optic biosensor for choline flow injection analysis.

A fibre optic biosensor based on luminol electrochemiluminescence (ECL) integrated in a flow injection analysis (FIA) system was developed for the detection of choline. The electrochemiluminescence of luminol was generated by a glassy carbon electrode polarised at +425 mV vs. a platinum pseudo-reference electrode. Choline oxidase (Chx) was immobilised either covalently on polyamide (ABC type) or on UltraBind preactivated membranes, or by physical entrapment in a photo-cross-linkable poly(vinyl alcohol) polymer (PVA-SbQ) alone or after absorption on a weak anion exchanger, DEAE (diethylaminoethyl) Sepharose. The optimisation of the reaction conditions and physicochemical parameters influencing the FIA biosensor response demonstrated that the choline biosensor exhibited the best performances in a 30 mM veronal buffer containing 30 mM KCl and 1.5 mM MgCl2, at pH 9. The use of a 0.5 ml min-1 flow rate enabled the measurement of choline by the membrane-based ECL biosensors in 8 or 5 min, with ABC or UltraBind membranes, respectively, whereas the measurement required only 3 min with the DEAE-PVA system. For comparison, the detection of choline was performed with Chx immobilised using the four different supports. The best performances were obtained with the DEAE-PVA-Chx sensing layer, which allowed a detection limit of 10 pmol, whereas with the ABC, the UltraBind and the PVA systems, the detection limits were 300 pmol, 75 pmol and 220 pmol, respectively. The DEAE-based system also exhibited a good operational stability since 160 repeated measurements of 3 nmol of choline could be performed with an RSD of 4.5% whereas the stability under the best conditions was 45 assays with the other supports.

Biosensing Techniques↗

Rapid determination of the glucose content of molasses using a biosensor.

A knowledge of the sugar content of molasses is of commercial importance to a number of industrial fermentations. Hence the feasibility of using a glucose oxidase biosensor to determine the glucose content of molasses samples was investigated. This method was compared with standard high-performance liquid chromatographic (HPLC) and gas-liquid chromatographic (GLC) procedures and with the use of a commercially available glucose analyser. A good correlation was obtained between the standard acetic anhydride GLC and glucose oxidase biosensor results (correlation coefficient = 0.98). Rapid and accurate measurements could be carried out using the biosensor without the need to employ the sample preparation step required in standard GLC methods. It was concluded that the use of the biosensor technique for the determination of glucose in molasses samples has distinct advantages over conventional methods.

Biosensing Techniques↗

Influence of surface-active compounds on the response and sensitivity of cholinesterase biosensors for inhibitor determination.

The influence of non-ionogenic surfactants, i.e., Tween-20, Triton X-100 and PEG-10,000, on the response of cholinesterase-based potentiometric biosensors and their sensitivity towards reversible and irreversible inhibitors were investigated. Acetyl- and butyrylcholinesterases were immobilized on nylon, cellulose nitrate films and tracing paper and were introduced into an assembly of potentiometric biosensors. The effect of surface-active compounds depends on the hydrophilic properties and porosity of the enzyme support material and the inhibition mechanism. In the range 0.002-0.3% m/v the surfactants show a reversible inhibiting effect on biosensor response. At lower concentrations (down to 10(-4)% m/v) the surfactants alter the analytical characteristics of reversible and irreversible inhibitor determination. The use of surface-active additives improves the biosensor selectivity in multi-component media.

Biosensing Techniques↗

Development and comparison of biosensors for in-vivo applications.

Electrochemical biosensors have been of increasing interest, especially those developed to be directly applied in diagnostic areas, such as neuroscience. We have been interested in developing a range of biosensors for monitoring glucose, lactate, pyruvate, and glutamate in order to study on-line both brain function in the laboratory and to monitor brain health in neurointensive care. For a biosensor to function effectively in these situations, it has to combine the following characteristics: quick response and high sensitivity, good reproducibility and adequate stability. In this study we compared the performance of a number of different amperometric biosensors strategies. These included ferrocene mediation of immobilised enzymes (system A), a redox hydrogel based system (system B), and a conducting polymer approach using polyaniline (system C). All assays were operated as flow-injection systems with upstream immobilised enzyme beds if necessary. When calibrated for H2O2 systems A and B reacted quickly enough to give quantitative conversion up to 0.2 mM. Above this concentration the response was limited by horseradish peroxidase enzyme kinetics and eventually enzyme loading. System C showed a restricted H2O2 response. When calibrated for glucose (by use of immobilised glucose oxidase) system B exhibited the highest sensitivity but its analytical range was restricted because the system became limited by H2O2 response. System A had low sensitivity for analyte compared to H2O2 and system B, but a greater useful range. Problems of mediator cycling between the immobilised enzymes are discussed. System C gave an excellent linear range but sensitivity was limited by background noise. Stability and reproducibility of the systems are also described. In conclusion, from this study the ferrocene system proved to be overall most useful and has now been used in the first dual on-line monitoring of glucose and lactate in patients in neurointensive care.

Biosensing Techniques↗

Microfluidic biosensing systems. Part II. Monitoring the dynamic production of glucose and ethanol from microchip-immobilised yeast cells using enzymatic chemiluminescent micro-biosensors.

A microfluidic flow injection (microFIA) system was employed for handling and monitoring of cell-released products from living cells immobilised on silicon microchips. The dynamic release of glucose and ethanol produced from sucrose by immobilised Saccharomyces cerevisiae cells was determined using microchip biosensors (micro-biosensors) with either co-immobilised glucose oxidase-horseradish peroxidase (GOX-HRP), or alcohol oxidase-horseradish peroxidase (AOX-HRP), catalysing a series of reactions ending up with chemiluminescence (CL) generated from HRP-catalysed oxidation of luminol in presence of p-iodophenol (PIP). The yeast cells were attached by first treating them with polyethylenimine (PEI) followed by adsorption to the microchip surface. The cell loss during assaying was evaluated qualitatively using scanning electron microscopy (SEM), showing that no cells were lost after 35 min liquid handling of the cell chip at 10 microl min(-1). The enzymes were immobilised on microchips via PEI-treatment followed by glutaraldehyde (GA) activation. The GOX-HRP micro-biosensors could be used during five days without any noticeable decrease in response, while the AOX-HRP micro-biosensors showed continuously decreasing activity, but could still be used employing calibration correction. The glucose and ethanol released from the immobilised yeast chips were quantitatively monitored, by varying the incubation time with sucrose, showing the possibilities and advantages of using a microfluidic system set-up for cell-based assays.

Biosensing Techniques↗

Characterization of gelatin-immobilized pigeonpea urease and preparation of a new urea biosensor.

Urease purified from pigeonpea seeds was immobilized on gelatin beads via cross-linking with glutaraldehyde. The maximum immobilization (75%) was observed at 30 mg/ml gelatin, 0.414 mg of enzyme/bead, 1% (v/v) glutaraldehyde and 4 degrees C. Beads stored in 50 mM Tris/acetate buffer (pH 7.3) at 4 degrees C showed a half-life of 240 days and there was practically no leaching of enzyme (less than 2%) over a period of 30 days. These beads can be reused more than 30 times (with 24 h intervals) without much loss of enzyme activity (i.e. less than 11%). The immobilized urease showed a shift in its optimum pH from 7.3 to 6.5 in Tris/acetate buffer. Optimum temperature also shifted from 47 to 65 degrees C compared with the soluble enzyme. Gelatin-immobilized pigeonpea urease had a higher K(m) (8.3 mM) than that of the soluble enzyme (3.0 mM). The time-dependent temperature inactivation pattern was also found to change from biphasic to monophasic kinetics. The immobilized beads were used for the preparation of a new urea biosensor with a response time of less than 2 min. At least 14 samples of urea can be measured with this biosensor within an hour. The beads, as well as the biosensor, were used to analyse the urea content in clinical samples from the local clinical pathology laboratories. The results obtained with the biosensor were strikingly similar to those obtained with the various commonly employed biochemical/autoanalyzer(R) methods used. These immobilization studies also have a potential role in haemodialysis machines that maintain the urea level in kidney patients and in the construction of a portable/wearable kidney. The easy availability of the pigeonpea urease, the ease of its immobilization on gelatin and a significantly lower cost of the urease described in the present study makes it a suitable product for future applications in therapeutics and diagnostics.

Biosensing Techniques↗