PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ANESTHESIA, SPINAL”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Transient neurologic symptoms after spinal anesthesia.

We recently reported several cases consistent with transient radicular irritation after spinal anesthesia with hyperbaric 5% lidocaine. The present prospective, blind, nonrandomized study was performed to determine the incidence of these transient neurologic symptoms and to identify factors that might be associated with their occurrence. We studied 270 patients scheduled for gynecologic or obstetric procedures under spinal anesthesia. For spinal anesthesia, either 5% lidocaine in 7.5% glucose or 0.5% bupivacaine in 8.5% glucose was used. Patients were evaluated on postoperative day 3 by a quality assurance nurse who was unaware of the drug given or details of the anesthetic technique. Transient neurologic symptoms were observed in 37% of patients receiving 5% lidocaine, whereas only one patient receiving 0.5% bupivacaine had transient hypesthesia of the lateral aspect of the right foot. These results suggest that symptoms were the result of a specific drug effect. However, because of the limitations of the study one cannot conclude that lidocaine per se was the cause.

Adolescent↗

[Comparison of 8 mg and 10 mg hyperbaric bupivacaine during spinal anesthesia for cesarean section in Japanese parturients].

BACKGROUND: Hypotension after spinal anesthesia for cesarean section is common and may result in serious complications despite the use of uterine displacement and volume preloading. Adequate amount of hyperbaric bupivacaine for Japanese parturients whose frames are generally smaller than those of Caucasian counterparts have not yet been examined. We compared the analgesic efficacy and the incidence of hypotension with 8 mg versus 10 mg hyperbaric bupivacaine during spinal anesthesia for cesarean section in Japanese parturients. METHODS: Thirty six parturients were randomly divided into two groups, one receiving 8 mg (n = 19) and the other receiving 10 mg (n = 17) hyperbaric bupivacaine. Sensory block level and the incidence of hypotension were evaluated from the time of injection to delivery. Hypotension was defined as a decrease in systolic blood pressure below 100 mmHg and to less than 80% of the baseline value. RESULTS: 15 minutes after spinal injection, the difference in sensory block level was not significant. Ten minutes after the spinal anesthesia, in 79% of 8 mg group and in 88% of 10 mg group, sensory block level reached T 4. Hypotension occurred in 19 parturients (7 in 8 mg group and 12 in 10 mg group). The incidence of hypotension was significantly lower in 8 mg group (37%) than in 10 mg group (71%). There were no significant differences either in neonatal Apgar scores or umbilical blood gas pH. CONCLUSIONS: Injection of 8 mg hyperbaric bupivacaine is preferable than 10 mg in spinal anesthesia for cesarean section to obtain adequate analgesic efficacy and to avoid maternal hypotension.

Adult↗

Power spectral analysis of arterial blood pressure after spinal anesthesia.

BACKGROUND: The continuous, on-line and real-time analysis of the power spectrum (CORAPS) of systemic arterial pressure (SAP) and heart rate (HR) signals is one of the current progresses in the development of non-invasive indexes for autonomic nervous system. It might be a useful clinical tool to monitor the progress of preganglionic block of sympathetic nervous system and the homeostatsis of cardiac neuroregulation after spinal anesthesia. The purpose of this study is to examine the relationship between the hypotensive response and the changes of components in CORAPS throughout the course of spinal anesthesia. METHODS: In 10 ASA class I-II patients (aged from 17 to 75 years) scheduled for elective surgery, we analyzed the changes of spectrum of systemic arterial blood pressure signals during spinal anesthesia. Spinal anesthesia was performed with 0.5% bupivacaine (dosage at 13-15 mg). For CORAPS, SAP signals were simultaneously relayed to an analog-digital converter connected to a computer. Power spectral density of the data was computed using a fast Fourier transform. The areas of the spectral peaks within each measurement were calculated as the follows: very low (BVLF, 0.01-0.08 Hz), low (BLF, 0.09-0.15 Hz), and high (BHF, 0.16-0.25 Hz). RESULTS: During the time interval (S2 period) when spinal anesthesia was initiated and 15 min thereafter the power density of low frequency (BLF), (1.2 vs. 2.3), and very low frequency (BVLF) components decreased, (3.4 vs. 7.8), in comparison with that at the baseline level (S1 period). We also found the shift of dominance between low frequency (BLF) and high frequency (BHF) in S2 period. The effects of intrathoracic pressure on the venous return may contribute to the increase of power density of BHF components (1.7 vs. 1.1). We also found that even in patients with stable hemodynamic variability, the decrease of BLF and BVLF components, and the shift of dominance were the same as in patients with unstable hemodynamic variability. CONCLUSIONS: It might prove that the cephalic spread of spinal block abolished the sympathetic tone of the autonomic nervous system. These results validated previous speculations of a sympathetic block during spinal anesthesia. More importantly, patients with stable hemodynamic variability still have profoundly sympathetic block with decreased power density of BLF and BVLF. The CORAPS is a good clinical monitoring tool to evaluate the homeostatsis of cardiac neuroregulation after spinal anesthesia.

Adolescent↗