At least 433 records · Page 24Linked to original sources

Long-term prognosis of extensive polyunit cantilevered fixed partial dentures.

The aim of this retrospective study was to elucidate the long-term prognoses of extensive fixed partial dentures including unilateral or bilateral polyunit cantilevers in patients with healthy but reduced periodontal support. Following periodontal therapy 36 cross-arch fixed partial dentures with two or more cantilever units unilaterally or bilaterally were fitted in 34 patients. In the prosthodontic design, special attention was given to the retention to long parallel preparations, to the dimensions of the framework, and to the occlusal design. After completion of therapy, the patients were enrolled in a regular maintenance care program and followed up for a period of 5 to 12 years. During this follow-up period one abutment tooth was fractured in one patient. One fixed partial denture with extremely reduced periodontal support was lost as a result of complete periodontal breakdown from occlusal trauma. For 33 fixed partial dentures, neither periodontal nor technical complications occurred.

Dental Abutments↗

Preparing teeth to receive a removable partial denture.

The success or failure of a removable partial denture is dependent on many factors. To achieve success, the practitioner must develop and sequence a sound treatment plan based on clinical and radiographic evidence. These findings must be carefully considered in prosthesis design and mouth preparation. Particular attention must be given to the proper placement of guiding planes and well-made rest seats and the use of surveyed crowns on abutment teeth. This article describes the rationale, importance, and clinical procedures for abutment preparation for removable partial dentures.

Crowns↗

Composite resin root coping with a keeper for magnetic attachment for replacing the missing coronal portion of a removable partial denture abutment.

Numerous methods for replacing missing removable partial denture abutments have been introduced, however, most of them are time consuming and require several visits to complete the procedure. Since magnetic attachments can provide support and bracing as well as retention for overdenture abutments, the remaining tooth root structure can be used to support the coping with the keeper. Through the use of composite resin and adhesive material, improved retention of the keeper to the root may be achieved, along with improved esthetics. This article describes a method for replacing the missing abutment of a removable partial denture with a magnetic attachment, and a composite resin coping with a keeper.

Composite Resins↗

Two-year follow-up study of Procera-ceramic fixed partial dentures.

PURPOSE: The aim of this prospective study was to determine whether a machine-fabricated titanium fixed partial denture veneered with a low-temperature fused porcelain is an acceptable treatment modality. MATERIALS AND METHODS: The study originally included 25 patients with 37 fixed partial dentures of three to seven units, with a total of 151 units including 98 abutments. A clinical examination using the California Dental Association quality evaluation system and radiologic examination and registration of complications was conducted at the time of insertion and after 1 and 2 years. RESULTS: After 2 years, 123 units (including 80 abutments) remained for examination. Twenty-eight units (including 18 abutments) were lost during the follow-up period. The losses were because of drop-out (eight cases), root fracture (two cases), caries (six cases), and periodontitis (two cases). One fixed partial denture fractured after 18 months and was therefore remade. In all, porcelain fractures occurred in two patients, both with severe parafunctional habits. At baseline, the California Dental Association rating system for marginal integrity was "excellent" for 72 abutments and "acceptable" for 26 abutments. At the 2-year follow-up the corresponding rating was "excellent" for 46 abutments, "acceptable" for 30 abutments, and "not acceptable" for four abutments. The latter marginal defects were corrected with restorations. For surface and color the corresponding ratings were "excellent" for 137 units and "acceptable" for 14 units at baseline, and "excellent" for 80 units and "acceptable" for 43 units at the 2-year follow-up. Bleeding index increased from 24% at baseline to 33% after 2 years. CONCLUSION: The study confirms that for an observation period of 2 years, fixed partial dentures made by the Procera method seem to be an acceptable treatment modality. They are a suitable alternative to fixed partial dentures with porcelain fused to high-noble alloys.

Adult↗

Success rate and failures for fixed partial dentures after 20 years of service: Part I.

PURPOSE: The objective of this study was to identify failures and to assess rate for fixed partial dentures constructed 20 years earlier by general practitioners in Sweden. MATERIALS AND METHODS: The original group consisted of 164 patients who had received prosthodontic treatment in 1974 comprising fixed partial dentures with at least five units. They had all been selected at random from the files of the Swedish Federal Dental Insurance Register. Twenty years later, 98 of them could be located and 72 of them agreed to participate in a clinical examination. The majority of drop-outs of the original group had died, could not be traced, or could not participate because of medical reasons. The examination focused on removed prostheses and/or units and a number of other clinically valid variables that will be reported in a forthcoming article. The 26 patients not participating in the clinical examination were interviewed by telephone. RESULTS: The examined participants had a total of 140 fixed partial dentures, 557 retainers, and 383 pontics still in service. When the number of failed and removed prostheses was calculated, a cumulative success rate of 65% was found, i.e., one third had been lost since 1974. There was no difference in failures between fixed partial dentures with or without cantilevers during the previous 8 years compared to the first 12 years in service. Loss of retention together with periodontal and esthetic problems, wear, and discoloration of acrylic veneers were the most frequently reported reasons for removal. CONCLUSIONS: The cumulative success rate for fixed partial dentures placed in 1974 was 65%. Failed prostheses had in most cases been replaced by a new fixed partial denture.

Adult↗

Influence of the partial denture on the articulation of dental and postalveolar sounds.

Dental prosthesis is a foreign body in oral cavity and thus necessarily interferes with speech articulation. The purpose of this study was to examine influence of partial denture on speech quality and to show eventual differences in pronunciation of dental sounds c[ts], z [z], s [s] and postalveolar sounds c [t], z [3] and s [integral of]. We have examined differences in pronunciation between subjects with removable partial dentures, the same group without partial dentures and a control group. The study was performed on 30 subjects with removable partial dentures and 30 subjects with complete dental arch. All subjects were recorded while reading six Croatian words containing the examined sounds. Recordings were analyzed with Multispeech Program (Kay Elemetrics Inc.). Acoustic analysis--LPC (linear prediction coding) provided formant peaks (Hz) for each examined sound, its intensity (dB) and formant bandwidths (Hz). Results showed that subjects with partial dentures had 50% less distorted variables and that prostheses did not completely restore articulation of postalveolar sounds. Groups with and without prostheses had lower formant peaks intensities and wider formant bandwidths in comparison to the control group. Partial dentures have not significantly interfered with resonance frequency. At the same time, pronunciation of the examined sounds was significantly improved. However, precision of the articulation movements has deteriorated.

Denture, Partial↗

Instructions for patients--a positive factor in removable partial denture service.

Studies have shown that improper wearing and care of removable partial dentures may adversely affect abutment teeth and associated periodontal tissues. A comprehensive removable partial denture service should include not only accurate construction of the prosthesis, but also printed instructions for the patient. Printed instructions help to inform the patient that delivery of removably partial dentures is only a part of our health service designed to maintain good oral health. A text of such concise printed information and instructions for the patient is presented.

Denture, Partial, Removable↗

Use of a cast flexible plate as a hinge substitute in a hinge-lock design removable partial denture framework.

PURPOSE: The use of a hinge for a removable partial denture with an opening labial bow was replaced by the design and construction of a flexible plate incorporated as part of a cobalt-chromium casting. METHODS: Three similar prostheses were constructed and tested in vitro on an endurance test machine. Each test piece completed 12,000 opening and closing operations without fracture, which a previous study showed is a probable life cycle of a typical removable partial denture with a hinged section. RESULTS: This plate provided sufficient flexibility to allow functional operation of the removable partial denture by a patient.

Chromium Alloys↗

Effect of reinforcement methods on the retention of resin-bonded fixed partial dentures using a composite denture tooth as a pontic: in vitro evaluation.

PURPOSE: The incorporation of composite denture teeth as pontics in resin-bonded fixed partial dentures has been deemed to be short-lived. This study investigated whether pre- or posttreatments could improve the bonding of denture tooth pontics. MATERIALS AND METHODS: A model fixed partial denture was fabricated that included composite denture teeth (Endura) bonded with 1 of 2 resin systems (C&B-Metabond or Aeliteflo). The bonding surface of the pontic was pretreated with one of three methods (air-particle abrasion [AA], AA plus silanization, or cavity preparation plus AA). The bonding areas between pontic and abutments were posttreated with 1 of 2 methods (reinforcement with fiber or metal post). Five bonded specimens for each treatment group were subjected to 20,000 thermocycles (40 degrees C to 60 degrees C; dwell time 60 s) before retentive forces (N) were determined. All data were analyzed with two-way ANOVA and Bonferroni's test (p = 0.05). RESULTS: All specimens that underwent the pre- and posttreatment outperformed untreated specimens. For the specimens bonded with C&B-Metabond and posttreated with a polyethylene fiber (Ribbond) or a metal post (DC Post), the mean retentive forces were 316 N and 301 N for mandibular specimens, and 354 N and 380 N for maxillary specimens, respectively. These values were significantly higher than those obtained with other pretreatment methods (p < or = 0.0003). For mandibular specimens bonded with Aeliteflo, specimens posttreated with Ribbond exhibited significantly higher retentive forces (332 N) compared to other specimens (p < or = 0.0001). CONCLUSION: Within the limitations of this study, the bond strength of a resin-bonded fixed partial denture incorporating a composite denture tooth as the pontic was improved by reinforcement with either a polyethylene fiber or a metal post.

Analysis of Variance↗

Chewing ability in patients restored with cross-arch fixed partial dentures.

The chewing ability of subjects with cross-arch fixed partial dentures was compared with that of subjects with complete healthy dentitions and complete-denture wearers. Chewing ability was expressed in terms of the number of chewing strokes, chewing time, chewing efficiency, and chewing performance. Almonds were used as the test food. In terms of chewing efficiency, that is, comminution in relation to time, subjects with cross-arch fixed partial dentures exhibited a chewing ability inferior to that of subjects with complete healthy dentition but superior to that of complete denture wearers. However, in terms of chewing performance, which describes the degree of pulverization before the time of swallow, chewing ability in subjects with cross-arch fixed partial dentures was almost as good as in subjects with complete, healthy dentitions and superior to that of complete denture wearers.

Dental Abutments↗

[Subjective evaluation of major connector designs for mandibular removable partial dentures].

The dentist himself is responsible for the design of the removable partial denture, because he must know and apply the biomechanical principles also. Two mandibular removable partial dentures, one with a lingual bar and the other with a lingual plate as the major connector were constructed for 7 men and 9 women patients who had mandibular Kennedy class I edentulous area. Patients used each type of prothesis for one month. At the end of this period, speeching, chewing and comford of partial dentures were evaluated according to the patients subjective impression. In general, patients adapted best to major connectors that covered soft tissues least was better. As a result, generally patients preferred lingual bar type denture.

Denture Design↗

The effects of buccolingual width and position of occlusal rest seats on load transmission to the abutments for tooth-supported removable partial dentures.

PURPOSE: The suitable buccolingual width and the location of occlusal rest seats for removable partial dentures have not been scientifically established. The aim of the present study was to use three-dimensional geometric analysis to evaluate the effects of buccolingual width and the location of occlusal rest seats on load transmission to the abutments for tooth-supported removable partial dentures. MATERIALS AND METHODS: A tooth-supported portion of a maxillary removable partial denture with two conventional circumferential cast clasps and an indirect retainer was analyzed. Occlusal loading of 100 N was applied to the buccal mesial cuspal incline 2.0 mm from the central fossa of the first molar or to the lingual mesial cuspal tip. Four combinations of position and width (wide, buccal shift, middle, and lingual shift) were simulated. RESULTS: For buccal loading, the wide rests and buccal-shift rests produced lower tensile forces at the indirect retainer. For lingual loading, the buccal-shift rests produced the lowest compressive force to the anterior abutment. CONCLUSION: Based on the tooth-supported removable partial dentures that were analyzed, buccal shifting of the rest seats seems to be advantageous for load transmission to the abutments.

Bicuspid↗

Intrusion of teeth in the combination implant-to-natural-tooth fixed partial denture: a review of the theories.

This article reviews the literature dealing with the combination implant-to-natural-tooth-supported fixed partial denture. The restoration of masticatory function with a combination implant-to-natural-tooth fixed partial denture is associated with a variety of undesirable clinical sequelae, including the breakage of implant components, damage to the abutment teeth, or intrusion of the abutment teeth. Theories regarding intrusion of abutment teeth combined with implants for fixed partial dentures are only speculative. Several theories are presented to explain the intrusion of natural teeth in association with implant-to-natural-tooth fixed partial dentures. One of the first theories was based on the idea that a lack of normal stimulation of the periodontal ligament produces atrophy of the periodontal ligament and intrusion of the tooth. The remaining theories relate to excessive forces being placed on the natural tooth, resulting in movement of the tooth to a less stressful position. These forces are placed on the tooth by differential energy dissipation, mandibular flexion and torsion, flexion of the fixed partial denture framework, impaired rebound memory, debris impaction or microjamming, or ratchet effect related to the use of precision attachments. Based a review of the literature, a philosophy for treating combination implant-to-natural-tooth restorations is presented.

Biomechanical Phenomena↗

A randomized clinical trial of two basic removable partial denture designs. Part II: Comparisons of masticatory scores.

STATEMENT OF PROBLEM: There is no known data on the functional efficacy of different removable partial denture designs. PURPOSE: This randomized clinical trial compared the masticatory performance of two commonly used designs in 118 patients who needed a unilateral or bilateral mandibular partial denture. MATERIAL AND METHODS: One half of the patients received a partial denture with distal occlusal rests and cast circumferential clasps and the other half a partial denture with mesial rests and I-bar cast clasps. The left side, right side, and swallowing threshold masticatory tests were made with peanuts and carrots before treatment and 16 weeks after the prosthesis insertion (baseline) and thereafter at 6, 18, 36, and 60 months. RESULTS: Masticatory scores at entry were higher in the circumferential design group, but the only significant (p < 0.05) difference was found in the right side carrot performance. Both groups realized significant improvements (p < 0.001) in all performance scores with partial dentures. Mean improvements of 24.7 with peanuts and 35.8 with carrots in the right side performance scores and 19.0 in the swallowing threshold score with peanuts in the bar design group were significantly higher (p = 0.017) than the respective mean improvements of 15.9, 21.4, and 5.6 in the circumferential design group. However, no significant differences were found between the two groups for any of the 10 performance scores at baseline. CONCLUSIONS: Despite some performance differences at entry, the mean performance scores for the two groups became similar at baseline and at subsequent intervals.

Arachis↗

Prosthodontic decision making among general dentists in Sweden. II: The choice between fixed and removable partial dentures.

PURPOSE: The purpose of this study was to describe how dentists evaluated various items related to a treatment choice between fixed partial dentures (FPD) and removable partial dentures (RPD), and to determine if the differences could be explained by dentist-related variables ("social and demographic attributes," "job situation," and "attitudes"). MATERIALS AND METHODS: Questionnaires were sent to a random sample of 2,059 Swedish general dentists, with a response rate of 76%. In the questionnaire, the choice between FPDs and RPDs in a clinical situation was presented. The dentists were asked to mark on 14-item visual analogue scales the relative importance he or she gave the different items. The items were analyzed through principal components analysis, where a 3-factor solution was obtained; the factors were labeled as "time," "health," and "comfort." The factors were run as dependent variables in multiple regression analyses. RESULTS: Great individual variations were seen, but the differences between groups of dentists were small. The items evaluated as most important were "patient's wish," "condition of possible abutment teeth," and "prognosis for delivered treatment." Male dentists gave significantly greater importance to the "health" factor compared to female dentists. The attitudinal variable "patient information" showed significant associations with all 3 factors in the multivariate models. CONCLUSION: Great individual differences were seen regarding the importance of the various items. In multiple regression models, several independent variables showed significant associations, most interestingly the attitudinal variable "patient information." Low explanatory (R2) values indicate that it is necessary to capture more variables of importance for the prosthodontic decision-making process.

Age Factors↗

Effectiveness of adhesive systems for a Co-Cr removable partial denture alloy.

PURPOSE: In vitro bond strengths of traditional denture base acrylic resin (Lucitone 199) to a cobalt-chromium partial denture alloy (J.D. Partial Denture Alloy) were tested using two surface pretreatments (sandblast, sandblast and electrochemical etch) with three adhesive primers: Lee Metal Primer, Acrylic Solder, and CR Inlay cement. A sandblasted group with no primer served as the control. MATERIALS AND METHODS: The alloy specimens (8.0-mm bonding diameter) were cast and invested to receive a traditional denture base resin after surface treatments (sandblasted, and sandblasted-electrochemically etched) and application of adhesive primers. The bonded specimens were stored in distilled water at 37 degrees C for 24 hours and divided into two groups. The first group was debonded in tension on a testing machine at a cross-head speed of 0.05 cm/min. The second group was subjected to thermocycling of 1,000 cycles and then tested for tensile bond strength. The force at which the bond failed was recorded, and the bond strength was calculated in megapascals (MPa). The sites of bond failure were examined, quantified under (20x) magnification, and recorded. Ten specimens were evaluated for each experimental condition for a total of 160 specimens. Data were analyzed by ANOVA with a factorial design. Means were compared by Tukey intervals at the 0.05 significance level. RESULTS: Significant differences in bond strength were observed, with primers being the most important factor, followed by pretreatment and storage and thermocycling with significant interactions. Sandblasted-electrochemically etched alloy with primers more effectively enhanced bond strength of the denture base resin to the treated alloy than sandblasted alloy with primers. Thermocycling had a greater effect on bond strength of the specimens with Acrylic Solder when compared with Lee and CR Inlay primers. The highest bond strengths (> or = 18.0 MPa) were observed for the conditions involving electrochemical etching and the priming with CR Inlay cement (both after 24 hours and thermocycling of 1,000 cycles). For primed specimens, the bond failures occurred cohesively within the primers or the denture resin and adhesively between the primers and the denture base resin, or between primers and alloy. For nonprimed, the bond failures occurred adhesively at the denture base resin-metal interface. CONCLUSIONS: Nonprimed specimens (both sandblasted and electrochemically etched) had lowest bond strength (0.4 +/- 0.1 MPa; 0.3 +/- 0.4 MPa). The bond strengths of the primed treated specimens were improved significantly. The CR Inlay-treated specimens exhibited the highest bond strength (20.6 +/- 6.3 MPa). After thermocycling for 1,000 cycles, the bond strengths of the specimens were significantly lower than the bond strengths of the specimens after 24 hours.

Acrylic Resins↗

Periodontal conditions with removable complete and partial dentures in the adult population aged 30 years and over.

The periodontal conditions of subjects with different combinations of removable dentures were studied in a representative sample of 8000 subjects, of which 90% were used for the experiment. The number of subjects with removable dentures was 1468. Subjects with removable partial dentures had significantly more pockets and deeper pockets than did those without dentures. The periodontal condition of subjects with a complete denture in the opposite jaw was significantly better than that in other subjects. This was true in both men and women. The results indicated the importance of prophylactic and maintenance care in subjects with removable partial dentures.

Adult↗