PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial, Removable”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Relining extension-base removable partial dentures.

Modern prosthodontic therapy must continue to address the inevitable consequence of tooth loss--that is, alveolar process atrophy. The use of removable partial dentures (RPDs) to treat partial edentia must rely, in part, on support from the ever-deteriorating edentulous ridges. Extension-base RPDs are particularly affected as the tissue-base relationship changes over time after extraction of the natural teeth. This article reviews the concept of observed changes in the residual edentulous alveolar ridge and conventional procedures used to compensate for this bone loss. Finally, a practical procedure is presented which uses convenient and accurate materials that can be readily incorporated into the modern dental practice.

Aged↗

[Position of removable partial dentures within prosthetic dentistry].

Recent developments in restorative dentistry resulted in a shift towards elderly patients with regard to the application of removable partial dentures (RPD). The half life time of a metal frame RPD is ten years. Negative effects of a RPD on the remaining dentition can be prevented by adequate oral hygiene, which is supervised in a recall program with an individually adjusted interval. Periodontal factors seem to be more important in the design of a RPD than biomechanical factors. Simplicity is a prime guideline in the design, especially in free-end situations.

Aged↗

[A survey of removable partial denture works in commercial dental laboratories].

To discover the methods by which general dental practitioners instructed the commercial dental laboratories to make removable partial dentures and to ascertain whether the dental practitioners had surveyed and designed the dentures by themselves or not. The investigations were carried out in two commercial dental laboratories, the results of this survey showed that most of the dental practitioners did not give clear instructions on the order cards. Only a very small amount of the work (5.90%) had any traces of survey lines. Evidence of tooth preparations were found to be 30.12 percent and only 24.22 percent of the master casts had designs drawn on them. More than half the work (70.5%) was given to the technicians so that they could carry out the designs on their own initiative, although it should be the sole duty and responsibility of the dental practitioners themselves.

Dental Technicians↗

The use of removable partial dentures amongst private dental practitioners in Singapore.

A questionnaire survey was carried out in 1995 amongst university trained general dental practitioners in the city state of Singapore to assess the use of removable partial dentures (RPD). 37% of the original sample of 469 completed and returned the questionnaire. The results of this survey indicate that RPDs are a common treatment modality in Singapore. Acrylic partial dentures appear to be the preferred choice for RPD treatment. The work profile of those who had a postgraduate qualification in removable prosthodontics did not differ from that of the general dental practitioner.

Acrylic Resins↗

Root retention and removable partial denture design.

The position of a retained root for preservation of a ridge requires modification of the design of a distal-extension removable partial denture on the side of the retained root. A model with silicone rubber over the ridges and simulated retained roots was fabricated. A framework with mesial rests, distal proximal plates, and I-bar clasp arms was fitted to it. A pencil lead was attached to the framework to record the arcs of rotation of the I-bar clasp arm. The movements and the fulcrums of the prosthesis were changed by the presence of simulated retained roots posterior to the distal abutment.

Dental Abutments↗

Usage and status of cobalt-chromium removable partial dentures 5-6 years after placement.

The aim of this study was to describe the usage of cobalt-chromium (Co-Cr) removable partial dentures (RPDs) by patients 5-6 years after denture insertion and to find out the factors that affected their denture usage. A random sample of patients provided with Co-Cr RPDs from a dental teaching hospital in Hong Kong was selected. Patients were interviewed using a structured questionnaire concerning their assessment and use of the dentures. Those who had been constantly wearing their original RPDs were examined by one calibrated examiner under optimal clinical conditions. The response rate of the patients who could be contacted was 98%. The results from 189 patient interviews showed that usage of the RPDs declined with time and that half of the dentures had been discarded or replaced 5-6 years after insertion. These discarded RPDs had been in use for an average of 19.5 months. The main reason given by the patients for not using the RPDs was general dissatisfaction with the dentures in various combinations of comfort, fit and chewing ability and, less importantly, with food trapping and appearance. No statistically significant association between denture usage and their respective Kennedy classification was found. The status of the Co-Cr RPDs that had been constantly used for 5-6 years was generally good. The majority of these RPDs demonstrated fair to good cleanliness, stability and retention and had no defect of any sort.

Adult↗

Wearing of removable partial dentures in relation to dental caries.

Using a representative sample of 5028 dentulous Finnish adults the occurrence of dental caries was studied among removable partial denture (RPD) wearers and non-wearers. Of the subjects wearing no RPD(s) 61.4% had one or more carious teeth, among those wearing a single RPD the figure was 60.5% and among those wearing RPDs in both jaws 62.7%, respectively. When sociodemographic background, other oral status measures than caries and oral health care habits were simultaneously controlled, subjects wearing RPDs in both jaws had slightly increased (P less than 0.05) probability of having one or more carious teeth compared to those with no RPD(s). Subjects with a single RPD did not have a statistically significantly increased probability of having carious teeth. Among those 3075 subjects who had one or more carious teeth the wearing of one or two RPDs did not significantly increase the number of carious teeth. Because the subjects wearing RPDs in both jaws were seen to have a slightly increased risk of having caries, this confirms the view that dentists should emphasize good oral hygiene habits and regular dental attendance among RPD wearers.

Adult↗

Longitudinal study on torque around the sagittal axis in lower distal-extension removable partial dentures.

The purpose of this study was to examine the longitudinal changes of torque around the sagittal axis in lower distal-extension removable partial dentures. The torque transmitted from the denture base to retainers was measured on several separate occasions from the insertion of new dentures to about 2 months after it. The maximal mean value of torque (Max.MT) was calculated from the magnitude of all chewing strokes of the minimum of the interocclusal distance. The integration values of torque (I) and time (T) from initiation of chewing to swallowing were obtained and then the average value of torque (Ave.T) was calculated (Ave.T = I/T). Subjects could be divided into two groups. Max.MT and Ave.T were almost constant in one group while they were remarkably decreased in another. After 1 month of insertion of new dentures the value of both groups was within the range of less than 3 x 10(-3) kgm (1 kgm = 9.8 Nm) of Max.MT and less than 1 x 10(-3) kgm ss-1 of Ave.T.

Adult↗

[A case report of removable partial denture with I-C attachment].

PATIENT: The alveolar bone and teeth for a patient involved in a traffic accident were prepared using removable partial dentures with I-C attachment. DISCUSSION: Because of using no clasp in the front teeth, sufficient supporting force of the dentures and no throbbing pain after insertion of the dentures, the patient was fully satisfied with the appearance and functional results of the treatment. CONCLUSION: In a case of loss of front teeth, the patient was content with the smaller and esthetically excellent attachment instead of a clasp. Moreover, the patient is progressing favorably. It is considered that the I-C attachment was effective for this case.

Dental Prosthesis Design↗

[Influence of interocclusal distance of mandibular unilateral distal extension removable partial denture on masticatory function].

The purpose of this study was to elucidate the influence on masticatory function when the mandibular unilateral distal extension removable partial denture changed the interocclusal distance. The experiments, crushability, the sense of mastication, and the masticatory strokes until swallowing, were conducted, on four subjects, using the denture with the apparatus that enabled to change the interocclusal distance. The results were as follows: The particle size distribution showed that the ratio of small particle (diameter 2.5-4.5 mm) decreased, while that of large particle (more than 5.0 mm) increased, on three of four subjects, and the value of crushability diminished. A reduction of the value of crushability when the interocclusal distance was extended more than 800 microns was found. As for the other subject, no change was recognized on the particle size distribution under experimental condition, and the value of crushability showed no significant change.

Dental Occlusion↗

Runner bar modification for mandibular removable partial dentures.

Breakage of a segment of an acrylic resin denture base of a mandibular removable prosthesis may result from inadequate retention and support. The runner bar modification can be a solution for this problem, especially where excessive crown length is to be restored in the mandibular anterior region. A technique is described for placement of a 14-gauge (1.7 mm) round wax runner bar that conforms to the anterior arch form on the removable partial denture wax-up. Wax vertical struts are added between the denture base retention and the runner bar. Improved retention and rigidity, without compromising esthetics and function, can be obtained through use of this procedure.

Denture Bases↗

Factors associated with masticatory performance in unilateral distal extension removable partial denture patients.

PURPOSE: Masticatory performance of denture patients is an outcome of the intricate inter-relationship between patient characteristics and denture construction. This study aimed to identify both patient- and denture-related factors associated with masticatory performance in unilateral distal extension removable partial denture patients (RPDs). MATERIALS AND METHODS: Seventy-two patients (25 male and 47 female, mean age 63.4 +/- 6.7 years) with unilateral distal extension RPDs were included in the study. The Mixing Ability Index (MAI) obtained from a chewing test using standard two-colored wax cubes, determined masticatory performance. The effect of each evaluated factor on masticatory performance was first determined by an independent t-test or one-way analysis of variance. The statistically significant factors were entered in a model of multivariate linear regression analysis to estimate the independent effect on MAI. RESULTS: The MAI ranged from -3.06 to 0.80 (Mean -0.71 +/- 0.86). Univariate analyses identified male gender, high maximum bite force, more functional tooth units, and natural dentition opposing RPDs as patient factors increasing the MAI. Multivariate analysis (adjusted R(2)= 0.346) revealed that gender (p < 0.001), maximum bite force (p= 0.02), and number of functional tooth units (p= 0.03) were independent predictors for masticatory performance. None of the denture-related factors had a significant influence on MAI. CONCLUSION: Gender, maximum bite force, and number of functional tooth units were the main factors influencing masticatory performance of unilateral distal extension RPD patients.

Aged↗

Longitudinal study of the influence of removable partial denture and chemical control on the levels of Streptococcus mutans in saliva.

Some studies have evaluated the salivary levels of mutans streptococci (MS) in removable partial denture (RPD) users. Saliva samples (2.0 mL) were obtained from 31 patients in six periods: (T0): immediately before installation of RPD; (T8): 8 days after T0; (T48): 48 days after T0; (T92): 92 days after T0; (T140): 140 days after T0 and (T189): 189 days after T0. The samples were vortexed and serially diluted from 10(-1) to 10(-6) in 0.05 m phosphate buffer (pH 7.4). From each dilution, 0.025 mL was plated on Mitis Salivarius Bacitracin (MSB). The plates were incubated in 5% CO2 at 37 degrees C for 72 h. There was an increase (t-test, P < 0.05) in the number of MS between periods T0 and T48 (mean/s.d., CFU mL(-1) of saliva): T0: 2.26/4.43 x 10(6) and T48: 0.47/1.48 x 10(8). After this, intensive treatment with CHX was accomplished in 29 patients. Saliva samples were obtained after treatment in four periods: (T24 h): 24 h after T0; (T14): 14 days after T24 h; (T28): 28 days after T24 h, and (T63): 63 days after T24 h. The number of MS in saliva did not decrease (t-test, P > 0.05). A new CHX formulation was applied in 15 patients. Saliva samples were obtained in periods: (T0): before new CHX application; (T24 h): 24 h after T0 and (T82): 82 days after T0. The new CHX reduced MS levels in saliva: (mean/s.d., CFU mL(-1) of saliva): T0: 6.64/8.47 x 10(6) and T24 h: 3.2/4.27 x 10(5) (sign rank, P < 0.05). In conclusion, there was a significant increase in the number of MS in saliva after the installation of RPD. The intensive treatment with a properly formulated CHX was effective in the reduction of MS, between 24 h and 82 days after its application.

Chlorhexidine↗

Treatment outcomes with removable partial dentures: a comparison between patient and prosthodontist assessments.

PURPOSE: This article presents the results from a survey of patients' degree of satisfaction with their removable partial dentures (RPD) and the comparison between patient and prosthodontist assessments. MATERIALS AND METHODS: A total of 165 experienced RPD wearers filled in a questionnaire and graded their RPDs depending on their level of satisfaction. A scale ranging from 1 to 5 was used to assess general satisfaction with RPDs and to assess their esthetics, retention, and hygiene. A specialist in prosthodontics assessed the same prostheses using the same scale, not knowing the patient's opinion. RESULTS: The patients' assessments were high, and more than half of them graded their dentures as excellent. On average, all variables were assessed higher by the patients than by the prosthodontist (P < .001). For the patients who gave the worst grades to their dentures, the grades were lower than the prosthodontist's (P < .001), while the satisfied patients graded their dentures much better than did the prosthodontist (P < .001). CONCLUSION: On average, patient assessment of the treatment outcomes with RPDs was less critical than prosthodontist assessment. However, the few dissatisfied patients assessed their dentures worse than did the prosthodontist.

Adult↗

Facial rests for a Kennedy Class IV removable partial denture.

A technique is presented in which acrylic resin extensions from the labial surface of the anterior tissue base of a Kennedy Class IV removable partial denture are used as retentive elements to minimize motion around the axis of rotation. The labial rests, formed by extending the base material of the prosthesis onto the mesiobuccal surfaces of the anterior abutments, act as guiding planes, preventing rotation of the prosthesis. The rests also improve esthetics by covering the interdental spaces often found between the prosthesis and the abutment teeth. The technique has been used successfully with 26 patients over a 3-year period.

Acrylic Resins↗

Designing clasps for the asymmetric distal extension removable partial denture.

Retentive clasp components can be created to minimize torquing forces on abutment teeth incorporated in the support and retention of bilateral distal extension removable partial dentures. Functional movement of the combined tooth-mucosa-borne prosthesis about the axis of rotation necessitates consideration of retentive element design modifications, particularly as they relate to bilateral asymmetric distal extension situations.

Dental Abutments↗

Qualitative changes in dental plaque formation related to removable partial dentures.

A study was performed on the microbial composition of dental plaque developing on fifteen abutment teeth in nine partially edentulous subjects. Bacteria were counted in samples of plaque which had formed on vestibular surfaces, and on proximal surfaces facing edentulous spaces, during a period when dentures were not worn, and then for a period when dentures were being worn. It was found that the presence of removable partial dentures favoured a proliferation of spiral organisms.

Adult↗