PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Digital network”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

On the Circuit Complexity of Sigmoid Feedforward Neural Networks.

This paper aims to examine the circuit complexity of sigmoid activation feedforward artificial neural networks by placing them amongst several classic Boolean and threshold gate circuit complexity classes. The starting point is the class NN(k) defined by [Shawe-Taylor et al. (1992)] Classes of feedforward neural nets and their circuit complexity. Neural Networks 5(6), 971-977. For a better characterisation, we introduce two additional classes NN(k)(Delta) and NN(k)(Delta,epsilon) having less restrictive conditions than NN(k) concerning fan-in and accuracy, and proceed to prove relations amongst these three classes and well established circuit complexity classes. For doing that, a particular class of Boolean functions F(Delta) is first introduced and we show how a threshold gate circuit can be recursively built for any f(Delta) belonging to F(Delta). As the G-functions (computing the carries) are f(Delta) functions, a class of solutions is obtained for threshold gate adders. We then constructively prove the inclusions amongst circuit complexity classes. This is done by converting the sigmoid feedforward artificial neural network into an equivalent threshold gate circuit [Shawe-Taylor et al. (1992)]. Each threshold gate is then replaced by a multiple input adder having a binary tree structure, relaxing the logarithmic fan-in condition from ([Shawe-Taylor et al. 1992]) to (almost) polynomial. This means that larger classes of sigmoid activation feedforward neural networks can be implemented in polynomial size Boolean circuits with a small constant fan-in at the expense of a logarithmic factor increase in the number of layers. Similar results are obtained for threshold circuits, and are liked with the previous ones. The main conclusion is that there are interesting fan-in dependent depth-size tradeoffs when trying to digitally implement sigmoid activation feedforward neural networks. Copyright 1996 Elsevier Science Ltd

Journal Article↗

[Value of CAD systems].

PURPOSE: Early detection of breast cancer enables for the reduction of mortality. The purpose of this article is to describe commercially available systems for computer-aided diagnosis (CAD) for mammograms and to analyze their diagnostic potential and utility. MATERIALS AND METHODS: Up to now, there are three CAD-systems available, the Image Checker M 1000 (R2-Technology, USA), the Second Look-system (CADx Medical Systems) and the Mammex TR (Scanis Inc., USA). Most of the present studies are done with the R2-system. The mammographies have been digitalized secondarily. Different algorithms recognized microcalcifications and masses. The connection between full field digital mammography systems and DICOM-networks is possible. RESULTS: In retrospective and one large prospective study with 12.860 patients it could be shown that sensitivity of the investigator with CAD could be improved up to 19%, microcalcifications are yielded with CAD in 100%, masses in up to 80%. CONCLUSION: Double-reading with CAD-systems can increase early breast cancer detection effectively. Regarding the development of full field digital mammography we are looking forward to further innovations.

Algorithms↗

[Server World-Wide Web on the Internet for the provision of clinical cases and digital radiologic images for training and continuing education in radiology].

The Internet, as a global computer network, provides opportunities to make available multimedia educational materials, such as teaching files and image databases, that can be accessed using "World-Wide Web" client browser to provide continuing medical education. Since August, 1995, at the Institute of Radiology-University of Palermo, we developed a World-Wide Web server on the Internet to provide a collection of interactive radiology educational resources such as teaching files and image database for continuing medical education in radiology. Our server is based on a UNIX workstation connected to the Internet via our campus Ethernet network and reachable at the uniform resource locator (URL) address: http:/(/)mbox.unipa.it/approximately radpa/ radpa.html. Digital CT and MR images for teaching files and image database are downloaded through an Ethernet local area network from a GE Advantage Windows workstation. US images will be acquired on-line through a video digitizing board. Radiographs will be digitized by means of a Charge Coupled Device (CCD) scanner. To set up teaching files, image database and all other documents, we use the standard "HyperText Markup Language" (HTML) to edit the documents, and the Graphics Interchange Format (GIF) or Joint Photographic Expert Group (JPEG) format to store the images. Nine teaching files are presently available on the server, together with 49 images in the database, a list of international radiological servers, a section devoted to the museum of radiology hosted by our Institute, the electronic version of the Journal Eido Electa. In the first 12 months of public access through the Internet, 12,280 users accessed the server worldwide: 45% of them to retrieve teaching files; 35% to retrieve images from the database; the remaining 20% to retrieve other documents. Placing teaching files and image database on a World-Wide Web server makes these cases more available to residents and radiologists to provide continuing medical education in radiology.

Computer Communication Networks↗

Computerized tongue diagnosis based on Bayesian networks.

Tongue diagnosis is an important diagnostic method in traditional Chinese medicine (TCM). However, due to its qualitative, subjective and experience-based nature, traditional tongue diagnosis has a very limited-application in clinical medicine. Moreover, traditional tongue diagnosis is always concerned with the identification of syndromes rather than with the connection between tongue abnormal appearances and diseases. This is not well understood in Western medicine, thus greatly obstruct its wider use in the world. In this paper, we present a novel computerized tongue inspection method aiming to address these problems. First, two kinds of quantitative features, chromatic and textural measures, are extracted from tongue images by using popular digital image processing techniques. Then, Bayesian networks are employed to model the relationship between these quantitative features and diseases. The effectiveness of the method is tested on a group of 455 patients affected by 13 common diseases as well as other 70 healthy volunteers, and the diagnostic results predicted by the previously trained Bayesian network classifiers are reported.

Artificial Intelligence↗

Some quantitative results on Golgi impregnated axons in rat visual cortex using a computer assisted video digitizer.

Axonal fiber distributions of pyramidal cells in the visual cortex of the albino rat have been investigated using the rapid Golgi method and modern data collecting techniques. Three dimensional coordinate information was extracted from Golgi-impregnated axonal networks using a computer-assisted video digitizer. Computer programs used this data to generate various statistical distributions. In particular, angular distributions of the initial collateral segments and their endpoints were examined and found to reveal anisotropies. Inspection of the spatial distributions of the endpoints indicated a clustering at two distinct levels with respect to the pyramidal cell from which they originate. Dynamic graphic displays of the three dimensional data have been obtained and presented in the form of computer tracings of various orthogonal projections.

Animals↗

Linear circuits for neural networks and affective computing.

Biological phenomena are often modeled with software on digital computers, even though the events may be analog in nature. The author describes the use of linear circuitry in two areas of biological simulation: artificial neural networks and affective computing. The operational amplifier, with the assistance of some new analog chips and simple digital microcontrollers, is featured prominently in these linear designs.

Computer Simulation↗

A digital model for the venous junctions.

The venous network in the lower limbs is composed of a considerable number of confluent junctions. Each of these singularities introduces some blood flow disturbances. Each physiological junction is unique, in terms of its geometry as well as the blood flow rate. In order to account for this great variability, we developed a numerical model based on the use of the N3S code (a software package for solving Navier-Stokes equations). To test the validity of the model, one of the numerical simulations is compared with the data obtained in the corresponding experimental configuration. The velocity measurements were carried out with an ultrasonic pulsed Doppler velocimeter. We also measured pressure differences using differential sensors. The numerical computations were then used to obtain the values of the flow variables at any point, with various geometrical and flow configurations. As far as the velocity field is concerned, a very marked three-dimensional pattern with swirls was observed. The pressure evolution was also strongly disturbed, with a non-linear decrease. All these data indicate that confluence effects cannot be neglected when evaluating pressure decreases. With a tool of this kind, it is possible to accurately predict the disturbances associated with any geometrical configuration or any flow rate.

Blood Flow Velocity↗

Integration of radiology and hospital information systems (RIS, HIS) with PACS: requirements of the radiologist.

PACS development has now reached a stage where it can clearly be stated that the technology for storage, networking and display in a fully digital environment is available. This is reflected by an already large and rapidly increasing number of PACS installations in USA, Western Europe and Japan. Such installations consist of a great variety of information systems, more or less interconnected, like PACS, HIS, RIS and other departmental systems, differing in both hardware and software. Various data - even if they only concern one person - are stored in different systems distributed in the hospital. The integration of all digital systems into a functional unit is determined by the radiologist's need of quick access to all relevant information regardless where it is stored. The interconnection and functional integration of all digital systems in the hospital determine the clinical benefits of PACS. This paper (1) describes the radiologist's requirements concerning this integration, and (2) presents some realistic solutions such as the Siemens ISI (Information System Interface), and a mobile viewing station for the wards (visitBox).

Austria↗

Authenticity and integrity of digital mammography images.

Data security becomes more and more important in telemammography which uses a public high-speed wide area network connecting the examination site with the mammography expert center. Generally, security is characterized in terms of privacy, authenticity and integrity of digital data. Privacy is a network access issue and is not considered in this paper. We present a method, authenticity and integrity of digital mammography, here which can meet the requirements of authenticity and integrity for mammography image (IM) transmission. The authenticity and integrity for mammography (AIDM) consists of the following four modules. 1) Image preprocessing: To segment breast pixels from background and extract patient information from digital imaging and communication in medicine (DICOM) image header. 2) Image hashing: To compute an image hash value of the mammogram using the MD5 hash algorithm. 3) Data encryption: To produce a digital envelope containing the encrypted image hash value (digital signature) and corresponding patient information. 4) Data embedding: To embed the digital envelope into the image. This is done by replacing the least significant bit of a random pixel of the mammogram by one bit of the digital envelope bit stream and repeating for all bits in the bit stream. Experiments with digital IMs demonstrate the following. 1) In the expert center, only the user who knows the private key can open the digital envelope and read the patient information data and the digital signature of the mammogram transmitted from the examination site. 2) Data integrity can be verified by matching the image hash value decrypted from the digital signature with that computed from the transmitted image. 3) No visual quality degradation is detected in the embedded image compared with the original. Our preliminary results demonstrate that AIDM is an effective method for image authenticity and integrity in telemammography application.

Computer Security↗

High speed digital circuits for medical communication; the MINCS-UH project.

In Japan, a high speed, bidirectional digital satellite communication system called Medical Information Network by Communications Satellite for University Hospitals is currently available in 30 national universities, and many programs, including clinical conferences, lectures and tutorials, have been broadcasted. Its characteristics are: (1) a state-of-the-art digital high-definition television system, (2) excellent security protection using digital encryption (3) bidirectional communications using two satellite circuits simultaneously, and (4) easy operability. High-quality motion images, and security protection mechanisms are essential for use in clinical medicine.

Computer Communication Networks↗

Asynchronous transfer mode technology for radiologic image communication.

Image communication is an important component in picture archiving and communication systems (PACS) and teleradiology applications. Currently, local area networks (LANs) and wide area networks (WANs) use different technologies for image communication. Asynchronous transfer mode (ATM) is an emerging technology that can be used for both LANs and WANs. This article describes experimental results using an ATM network to transmit CT scans and digitized radiographs between the University of California, San Francisco (UCSF) and Mount Zion Hospital, an affiliated community hospital in the San Francisco Bay area. The WAN connection between the two hospitals is via an ATM main switch at Pacific Bell, a local communication carrier located in Oakland, CA, which uses single-mode optical fibers. Preliminary results show that, using the ATM Optical Carrier Level 3 (OC3) (155 Mbits/sec) specification, it takes 1.3 sec and 2.7 sec to transmit a 10-Mbyte digitized radiograph and a 20-Mbyte CT scan, respectively, between the two locations. Encouraged by these results, we have designed and implemented an ATM WAN and LAN between UCSF and Mount Zion Hospital. This is the first of a three-phase project of installing a WAN serving four hospitals and one clinic in the San Francisco Bay area.

Computer Communication Networks↗

Speech recognition by an artificial neural network using findings on the afferent auditory system.

An artificial neural network which uses anatomical and physiological findings on the afferent pathway from the ear to the cortex is presented and the roles of the constituent functions in recognition of continuous speech are examined. The network deals with successive spectra of speech sounds by a cascade of several neural layers: lateral excitation layer (LEL), lateral inhibition layer (LIL), and a pile of feature detection layers (FDL's). These layers are shown to be effective for recognizing spoken words. Namely, first, LEL reduces the distortion of sound spectrum caused by the pitch of speech sounds. Next, LIL emphasizes the major energy peaks of sound spectrum, the formants. Last, FDL's detect syllables and words in successive formants, where two functions, time-delay and strong adaptation, play important roles: time-delay makes it possible to retain the pattern of formant changes for a period to detect spoken words successively; strong adaptation contributes to removing the time-warp of formant changes. Digital computer simulations show that the network detect isolated syllables, isolated words, and connected words in continuous speech, while reproducing the fundamental responses found in the auditory system such as ON, OFF, ON-OFF, and SUSTAINED patterns.

Acoustic Stimulation↗

The Baltic Health Network - Taking Secure, Internet-based Healthcare Networks to the Next Level.

Internet-based health care networks are a step forward compared to first generation health care networks, which has been limited to pushing text-based messages between different systems. An Internet-based network can also "pull" data - and not only text but any digital data - for instance images and video sequences. The Internet-based networks can more effectively fulfil the vision of access to relevant data regardless of time and location. Although far from identical, the health delivery systems of Denmark, Norway and Sweden are similar. They also share a shortage of specialized health personnel - not least radiologists and in some regions obstetricians. Furthermore, over the past ten years they have implemented an IT-strategy to increase efficiency in the delivery of healthcare services. Part of this strategy has been to build three national networks on top of the existing regional, secure and Internet-based healthcare networks. These national networks connect not only all hospitals in the three countries, but also a majority of the other stakeholders in the healthcare sector (GPs, private specialists, laboratories, homecare services etc.). The organizations behind the three networks are now working on creating a trans-national network, the Baltic Health Network (BHN), which will be one of the outcomes of the Baltic eHealth project and will not only connect the three national networks but also add two hospital networks from Lithuania and Estonia. The BHN is expected to be operational by June 2005. One of major advantages of the BHN is that the many rural hospitals of the Baltic Sea Area with a few mouse clicks can reach a specialist for second opinion in any of the approximately 200 hospitals connected to the network. For instance the midwives in the rural areas of Västerbottan County, Sweden, are awaiting the establishment of BHN to get access to second opinions from specialists at National Center for Foetal Medicine at the University Hospital of Trondheim, Norway. The BHN will remove a very important technical barrier for collaboration between health professionals and the Baltic eHealth project hopes that this and other project initiatives will facilitate the large-scale usage of second opinion from available health care experts regardless of institutional, regional and even national borders. This will lift the quality of service to patients in the Baltic Sea Region - especially in the rural areas where highly specialized health professionals tend to be geographically far away.

Cooperative Behavior↗

[Study of the mechanisms of the development of epileptic activity in neuronal networks using a simulation model].

The occurrence of synchronous, self-sustaining seizure activity is one of the basic mechanisms underlying epileptic attacks. Using a mathematical model of neuronal network in various simulation experiments carried out in digital computer the conditions were studied of the development of pathological epileptic activity and the conditions of the parameters of this network affecting its stable function. After exceeding of a threshold value in the relation between the weights of the stimulating and inhibiting synapses an unstable epileptic response appears. In the state of the so called conditional stability the network is highly sensitive to even small changes of the parameters. These observations make possible a new look at a number of phenomena found in clinical cases and in experiments.

Action Potentials↗

Neural networks as an aid in the diagnosis of lymphocyte-rich effusions.

Neural network (NN) technology was applied to digital image analysis data for 112 Papanicolaou-fixed and -stained smears of lymphocyte-rich effusions (LREs). The smears were analyzed with an inexpensive image analysis system assembled in our laboratory. Several models were developed using backpropagation NN development software in an effort to optimize classification of the LREs as reactive lymphocytosis or malignant lymphoma and to analyze the effects of various parameters on classification rates. The greatest specificity and sensitivity of LRE classification were achieved with NN models that consisted of 7 input neurons, including 5 morphometric and 2 densitometric variables, 10 hidden-layer neurons and 1 output neuron. This NN architecture with a sigmoidal transfer function provided a true cross-validation rate of 89.3% of testing data, with a sensitivity of 76.9%, specificity of 93.0% and shrinkage of 10.7%. The same NN architecture with a step transfer function provided a true cross-validation rate of 95.3%, sensitivity of 85.7%, specificity of 97.6% and shrinkage of 0%. The effects of various parameters, such as network size, shrinkage and ratio of sample size to input layer size, on NN accuracy are discussed.

Ascitic Fluid↗

Wireless networking for the dental office: current wireless standards and security protocols.

Digital radiography has gained immense popularity in dentistry today in spite of the early difficulty for the profession to embrace the technology. The transition from film to digital has been happening at a faster pace in the fields of Orthodontics, Oral Surgery, Endodontics, Periodontics, and other specialties where the radiographic images (periapical, bitewing, panoramic, cephalometric, and skull radiographs) are being acquired digitally, stored within a server locally, and eventually accessed for diagnostic purposes, along with the rest of the patient data via the patient management software (PMS). A review of the literature shows the diagnostic performance of digital radiography is at least comparable to or even better than that of conventional radiography. Similarly, other digital diagnostic tools like caries detectors, cephalometric analysis software, and digital scanners were used for many years for the diagnosis and treatment planning purposes. The introduction of wireless charged-coupled device (CCD) sensors in early 2004 (Schick Technologies, Long Island City, NY) has moved digital radiography a step further into the wireless era. As with any emerging technology, there are concerns that should be looked into before adapting to the wireless environment. Foremost is the network security involved in the installation and usage of these wireless networks. This article deals with the existing standards and choices in wireless technologies that are available for implementation within a contemporary dental office. The network security protocols that protect the patient data and boost the efficiency of modern day dental clinics are enumerated.

Computer Security↗

Optimized quality of histologic images allows the use of neural network scanning in diagnosis of fungal infection of abnormal nails.

OBJECTIVE: The neural network scanning (NNS) system, formerly known as Papnet, is capable of selecting fungi in cervical smears. The objective of this study was to investigate whether the optimized quality of histologic images created using a combination of coagulant fixation and microwave histoprocessing allows the application of this computer-assisted microscopy in the diagnostic process. STUDY DESIGN: In a prospective study, 117 abnormal nails clinically suspect for fungal disease werefixed in a coagulant fixative, BoonFix, processed in a microwave histoprocessor to obtain optimal paraffin sections and stained with the periodic acid-Schiff (PAS) method. The stained paraffin sections were randomly numbered and screened by two independent pathologists for diagnosis of fungal hyphae and spores. The same sections were subsequently scanned by a neural network, and a maximum of 128 digital images produced by the system were screened and diagnosed by pathologists. Using light microscopy as the gold standard for diagnosis of fungi, the usefulness of NNS was then assessed. RESULTS: The fungi and spores were clearly demonstrated in the paraffin sections, and the NNS system detected and recorded them efficiently. The hyphae and spores could be identified in these pixilated images with relative ease. Of the 117 examined cases, 50 were positive and 47 negative by both methods. In the 20 remaining cases, NNS did not present images of fungi that were present in the histologic sections. In practice, this implies that only 67 out of 117 cases (57%) must be screened by light microscopy. NNS recorded not only fungi and spores in the 128 digital images but also artifacts, such as round, deeply PAS-positive granules of talcum powder, which by light microscopy might be mistaken for fungal spores. CONCLUSION: NNS proves applicable for the selection of spores and fungi if the histologic sections are of sufficiently high quality. As a result, the number of slides to be screened by light microscopy can be reduced substantially. In a throughput diagnostic laboratory handling a large number of such cases this technology can be highly valuable.

Adolescent↗