PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Graphite”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Simulation of emission molecular spectra by a semi-automatic programme package: the case of C2 and CN diatomic molecules emitting during laser ablation of a graphite target in nitrogen environment.

Some emission spectra of diatomic molecules were calculated by a semi-automatic programme package in order to infer the rotational and vibrational temperatures in Boltzmann distribution by comparing them with the corresponding experimental ones. The calculation procedure was applied in the case of CN radical and C2 molecule whose optical emission spectra were recorded during pulsed excimer laser ablation of a graphite target in low-pressure nitrogen environment. Computed similar or dissimilar values of rotational and vibrational temperatures let to verify the existence or not of local thermodynamic equilibrium and to hypothesise the temporal range necessary to establish it in such experiments.

Carbon↗

Theoretical study on the electrochemical behavior of norepinephrine at Nafion multi-walled carbon nanotubes modified pyrolytic graphite electrode.

DFT-B3LYP/6-31G (d, p) and HF/6-31G (d, p) calculations are performed for deoxidized norepinephrineat (NP(R)) and its oxidized form (NP(O)). The electrochemistry of norepinephrineat (NP) was studied by cyclic voltammetry (CV) at a pyrolytic graphite electrode modified by Nafion multi-walled carbon nanotubes (MWNTs) in phosphate buffers at pH 6.0, showing that the standard electrode potential of half reaction for NP(O), H+/NP(R) is 0.75l V. This experimental standard electrode potential of half reaction is consistent with that calculated using the energies of solvation and sum of electronic and thermal free energies of NP(R) and NP(O). The frontier orbital theory and Mülliken charges of molecular explain the electrochemical behavior of CV at modified electrode well. The singlet vertical excited states for NP(R) and NP(O) are also discussed.

Buffers↗

The electrode reaction of Euglena gracilis cytochrome c-552 at edge-oriented pyrolytic graphite.

The direct electron transfer reaction of Euglena gracilis cytochrome c-552 at edge-oriented pyrolytic graphite electrodes was determined by cyclic voltammetry to be quasi-reversible, stable and reproducible. The presence of a persistent layer of irreversibly adsorbed cytochrome c-552 on the electrode surface was detected in these experiments. Heterogeneous electron transfer rate constants for both the diffusing and adsorbed forms of the protein are reported, and mechanistic aspects are addressed. The applicability of cytochrome c-552 as a complementarily charged analog of eucaryotic cytochrome c in interfacial bioelectrochemical studies is discussed.

Adsorption↗

Chromatographic study of terpene derivatives on porous graphitic carbon stationary phase with beta-cyclodextrin as mobile phase modifier.

The stoichiometric coefficients and apparent formation constants (Kf) of alpha-terpineol, thymol, geraniol and linalool complexes with beta-cyclodextrin (beta-CD) were determined using HPLC with a porous graphitic carbon (PGC) chromatographic support. Measurements were performed with four different methanol-water mobile phases. All the terpene derivatives under study form 1:1 guest-CD complexes. Graphs of Kf as a function of the mobile phase composition appeared different from those classically described for RP-C18 and suggest that the PGC stationary phase could play an active role in the complexation process. Solute-CD inclusion and solute-stationary phase interactions may be involved in this specific behavior.

Chromatography, High Pressure Liquid↗

Chiral ion-pair chromatography on porous graphitized carbon using N-blocked dipeptides as counter ions.

Two newly synthesized chiral di-anionic counter ions were tested for enantiomeric resolution of a set of amino alcohols on porous graphitized carbon, Hypercarb. Z-L-Aspartyl-L-proline dissolved in methanol baseline resolved nine of 12 tested racemates. One of its diastereoisomers, Z-L-aspartyl-D-proline was also tested but resulted in low separation factors, <1.1. Sodium hydroxide was added to the mobile phase in order to titrate the counter ion to its mono- or di-anionic form. Results show that the di-anionic form was found to be superior to the mono-anionic form regarding enantioselectivity. Increased content of the counter ion in the mobile phase, with constant ratio between counter ion and sodium hydroxide concentration, decreased retention but only slightly affected enantioselectivity. Increased retention and enantioselectivity were observed with decreased column temperature. Resolution factors >3 were obtained between the enantiomers in atenolol and metoprolol with a total retention time of less than 15 min. Further, all four stereoisomers of an analogue to metoprolol were separated using Hypercarb and a mobile phase of 5 mM Z-L-aspartyl-L-proline and 9 mM sodium hydroxide in methanol.

Chromatography, Liquid↗

Separation of isomers of nonylphenol and select nonylphenol polyethoxylates by high-performance liquid chromatography on a graphitic carbon column.

p-Nonylphenol (NP) is a ubiquitous degradation product of nonylphenol polyethoxylate (NPE) surfactants and has been reported to be an endocrine disrupter. It is composed of numerous structural isomers resulting from the various branching patterns of the C-9 group. Twenty-two isomers in a technical mix of NP have been identified with high-resolution capillary GC-MS. In most HPLC analyses, nonylphenol elutes as a single, broad peak. In the method described here, HPLC using a graphite carbon column resulted in the resolution of a technical mixture of NP into 12 peaks or groups of isomers. This method was also applied to select NPEs with one to 10 ethoxy units with similar results. Separation was achieved by gradient elution with 1% acetic acid in water and acetonitrile. Elution of individual isomers 4-butylphenol and 4-propylphenol under the same gradient conditions indicate that increased branching of an alkyl group results in shorter retention times than for the less substituted alkyl groups. This method can be used to fractionate NP based on structure and assess the potential for different isomers (or groups of structurally similar isomers) to act as endocrine disrupters.

Chromatography, High Pressure Liquid↗

Use of porous graphitic carbon coupled with mass detection for the analysis of polar phenolic compounds by liquid chromatography.

Phenolic compounds present in olive mill wastewater (OMW) need to be quantified because of their pollution capacity toward the environment. In the present study, six representative phenolic compounds of OMW were chosen to develop a LC-MS method. The high polarity of the compounds caused problems when using traditional reversed-phase liquid chromatography (RPLC). Consequently, a method was developed on another kind of chromatographic phase: Porous Graphitic Carbon (PGC) involving the use of a tetrahydrofuran (THF) gradient. The influence of THF as mobile phase in LC-MS coupling, which is not common practice, was evaluated. In Atmosperic Pressure Chemical Ionisation (APCI) in the negative ion mode, the presence of THF in the mobile phase did not degrade the MS signal of the target compounds in the conditions studied. On the contrary, an improvement was even observed when the percentage of THF increased. The proposed PGC-LC-MS method was selective and linear for the six phenolic compounds analysed with limits of quantification lower than 5 ppm in all cases. The precision was satisfactory (pooled RSD around 6%). The analyses of OMW matrix spiked sample confirmed the good performance of the proposed method.

Chromatography, Liquid↗

Solid-phase extraction of chloramphenicol with graphitized carbon black.

The sorption and desorption properties of graphitized carbon black (GCB) were evaluated for enrichment of highly polarizable chloramphenicol (CP) from biological fluids. The distribution of CP between GCB and water lay strongly toward GCB. Among the organic solvents examined, methanol gave the lowest adsorption coefficient. The optimum packing amount of GCB, and the optimum volume and flow-rate of the eluent were deduced from the breakthrough curve and methanol elution curve, respectively. The inner diameter of GCB extraction columns was chosen from the sorption efficiency curve obtained by plotting CP recovery against column inner diameter. The solid-phase extraction method using GCB was applied to the assay of CP in serum samples in the concentration range of 5 to 50 micrograms/ml.

Absorption↗

Role of the Na+ ion on phenol derivatives/hydroxypropyl-beta-cyclodextrin complex formation on porous graphitic carbon phase.

The reversed-phase liquid chromatography retention of phenol derivatives was investigated over a concentration range of sodium chloride (0-10(-2) M) and hydroxypropyl-beta-cyclodextrin (HP-beta-CD) (0-35x10(-3) M) using a porous graphitic carbon (PGC) stationary phase and a methanol/water mixture (50:50 (v/v)) as the mobile phase. A theoretical treatment was developed to investigate the effect of the sodium chloride and hydroxypropyl-beta-cyclodextrin on the equilibrium between the solutes with the PGC surface and the aqueous medium, respectively. The thermodynamic parameter variations were calculated using van't Hoff plots. It was expected that the sodium ion acted on the solute-PGC association process by modifying the surface tension of both the bulk solvent and the PGC surface. The phenol derivative/HP-beta-cyclodextrin complexation was shown to be entropically controlled for all the solutes except for the one which contained the -NO2 group in its structure, i.e. the nitro phenol derivative. A comparison of the compensation temperature of the solute-PGC association process when sodium chloride and HP-beta-CD concentration changed in the mobile phase led to the conclusion that these two modifiers acted via a variation in the hydrophobic effect.

2-Hydroxypropyl-beta-cyclodextrin↗

Simultaneous microanalysis of N-linked oligosaccharides in a glycoprotein using microbore graphitized carbon column liquid chromatography-mass spectrometry.

We previously reported that graphitized carbon column liquid chromatography-mass spectrometry (GCC-LC-MS) is very useful for the structural analysis of carbohydrates in a glycoprotein. In this study, GCC-LC-MS was adapted for the simultaneous microanalysis of oligosaccharides. A variety of oligosaccharide alditols prepared from fetuin, ribonuclease B, and recombinant human erythropoietin were used as model oligosaccharides. The use of microbore GCC-LC-MS was found to be successful for rapid, sensitive, and simultaneous analysis of high-mannose-type, desialylated fucosyl complex-type, sialylated complex-type, and sialylated fucosyl complex-type oligosaccharide alditols. Furthermore, we demonstrate that this method is applicable to the analysis of carbohydrate heterogeneity in a glycoprotein that possesses diverse oligosaccharides. Microbore GCC-LC-MS was able to characterize high-mannose-type, hybrid-type, and complex-type oligosaccharides in tissue plasminogen activator produced from human melanoma cells in a single analysis.

Carbohydrate Sequence↗

Ability of porous graphitic carbon to support electroosmotic flow in capillary electrochromatography.

The existence of a cathodic EOF (electroosmotic flow) in the case of a porous graphitic carbon (PGC) partially packed column has been demonstrated. Then, the ability of PGC to afford electroosmosis has been brought to the fore with a fully PGC packed column. Experimental data have shown that PGC particles are negatively charged and their electrophoretic mobility has been evaluated. In order to investigate the conditions of existence of EOF different mobile phases have been tested. An EOF occurs when the conductivity of the PGC packed column is larger than the conductivity of an empty fused-silica capillary operating in the same conditions i.e. when the PGC participates in the electric conduction. Since the local electric fields in the two segments of the column are different, an evaluation of the electroosmotic mobility is not possible and the effect of the operational parameters such as the composition of the mobile phase (acetonitrile ratio and total ionic strength) has been studied in term of electroosmotic velocity V(eo).

Chromatography, Micellar Electrokinetic Capillary↗

Eluotropic strength in non-aqueous liquid chromatography with porous graphitic carbon.

Porous graphitic carbon is an attractive packing for the chromatographic analysis of highly hydrocarbonaceous compounds with non-aqueous mobile phase. An eluotropic-strength scale of 10 pure organic solvents was established using the methylene selectivity from the fatty acid methyl ester homologous series (chain length between 18 and 31 carbon atoms). Eight binary mobile phases combining a weak solvent: methanol or acetonitrile with a strong solvent: toluene, chloroform, dichloromethane or tetrahydrofuran at different volume fractions phi of strong solvents (ranging from 0.3 to 1.0) were tested and their eluotropic strengths were then compared with those of pure solvents. The curves of the eluotropic strength versus the volume fraction of the strong solvent followed two different trends: linear or curved. The knowledge of the pure solvent strength is not sufficient to predict the eluotropic strength of solvent in the mixture. Then modelling of the eluotropic strength for binary mobile phases was envisaged in order to provide a prediction tool. This model was assessed for the establishment of the composition of eight iso-eluotropic mobile phases. Good assessment was found except in the case of toluene with acetonitrile where the difference between the predicted and the real value was the highest.

Chromatography, Liquid↗

Comparison of the performance of graphitized carbon black and poly(styrene-divinylbenzene) cartridges for the determination of pesticides and industrial phosphates in environmental waters.

The determination of polar and nonpolar organophosphorus compounds, triazines and their metabolites, molinate and chlorothalonil in 1 l water samples was investigated using off-line solid-phase extraction followed by gas chromatography with nitrogen-phosphorus and flame photometric detection. The ethylvinylbenzene-divinylbenzene copolymer (LiChrolut EN) and the commercial graphitized carbon black (GCB) of Envi-Carb were tested as solid-phase sorbents. The matrix effect was studied by extracting the compounds spiked in water samples of different types (Milli-Q, tap, salted tap water, river and sea water). The polymeric sorbent LiChrolut EN allowed the determination at low ng/l of all 40 compounds tested, except the very polar atrazine-desethyl-deisopropyl (DDA). Recoveries of compounds from the Envi-Carb sorbent are comparable to those obtained for LiChrolut EN with the exception of chlorothalonil and the more hydrophobic organophosphorus compounds (coumaphos, leptophos), which were strongly sorbed in the Envi-Carb cartridges. Envi-Carb, however, enabled the determination of DDA with a limit of detection of 14 ng/l.

Adsorption↗

Evaluation of stearate-graphite paste electrodes for chronic measurement of extracellular dopamine concentrations in the mammalian brain.

Chronoamperometric procedures, in combination with pharmacological treatments, were used to verify whether stearate-modified graphite paste recording electrodes (SGEs) could measure basal extracellular dopamine (DA) concentrations in the striatum of awake rats over a 3-week period of implantation. Baseline chronoamperometric signals were unaffected by systemic injections of ascorbate (AA) or the monoamine oxidase inhibitor pargyline, or by intraventricular infusions of the AA degrading enzyme AA-oxidase. In contrast, systemic injections of d-amphetamine or nomifensine increased, and gamma-butyrolactone decreased, the signal in a reproducible fashion over a similar test period. In addition, 6-hydroxydopamine lesions of the nigrostriatal DA pathway attenuated the ability of d-amphetamine to increase, and gamma-butyrolactone to decrease, the chronoamperometric signal. In separate studies, reverse microdialysis, performed with dialysis probes implanted directly adjacent to SGEs in the striatum, permitted the assessment of electrode selectivity, sensitivity, response linearity, and detection limits to DA. Perfusion of the probe with normal Ringer solution (5 microliters/min) decreased the baseline chronoamperometric signal by 10 nA. Comparable decreases in the baseline signal were observed after systemic injections of gamma-butyrolactone or medial forebrain bundle infusions of tetrodotoxin, suggesting these decreases reflected depletion of extracellular DA to levels below the electrode's detection limit. Reverse dialysis with high concentrations of AA, DOPAC, 5-HT, or 5-HIAA, failed to reverse the decrease in the chronoamperometric signal induced by dialysis. In contrast, reverse dialysis with a physiologically relevant range of DA concentrations, in rats pretreated with the DA uptake blocker nomifensine, increased the chronoamperometric signal in a linear fashion with a detection threshold of < 20 nM. Combined, these results indicate that the baseline chronoamperometric signals recorded at +0.20 V in the striatum with SGEs do not reflect changes in extracellular concentrations of AA, DA metabolites, or indoles, but rather represent neuronally mediated nanomolar changes in extracellular DA concentrations, even after extended periods of implantation in brain tissue.

3,4-Dihydroxyphenylacetic Acid↗

Scanning tunnelling microscopy observation of cytochrome-c denaturation induced by bromopyrogal red on highly oriented pyrolytic graphite.

The denaturation of cytochrome-c (cyt-c) induced by bromopyrogal red (BPR) was studied by scanning tunnelling microscopy (STM) on the electrochemically pretreated highly oriented pyrolytic graphite (HOPG) surface. STM images reveal that denatured cyt-c molecules exist in variable states including aggregates, globular compact, partially unfolded and combined with BPR molecule. The apparently low image contrast of denatured cyt-c observed in this experiment comparing to that of native cyt-c molecules, and the relative low image contrast of the unfolded part comparing with the compact globular part, are ascribed to the unfavourable tunnelling paths for the conformational variations of denatured cyt-c molecules.

Animals↗

Electrooxidation of phenol by catalase immobilized on graphite electrodes.

Electrocatalytic properties of catalase (CAT) immobilized on graphite and soot to mediate electrooxidation of phenol have been investigated. The kinetic parameters--Km, k(s), deltaG*Ar and Z0 of the process studied were calculated. Conclusions on a probable mechanism of the biocatalytic and electrochemical process observed were drawn from the calculated values of activation and kinetic parameters. A quantitative UV-spectrophotometrical approach was used as an analytical tool. The electrochemical oxidation of phenol was examined with potentiodynamic and polarization curves' method.

Catalase↗

Direct electrochemistry of hemoglobin in layer-by-layer films with poly(vinyl sulfonate) grown on pyrolytic graphite electrodes.

Stable layer-by-layer electroactive films were grown on pyrolytic graphite (PG) electrodes by alternate adsorption of layers of polyanionic poly(vinyl sulfonate) (PVS) and positively charged hemoglobin (Hb) from their aqueous solutions. Cyclic voltammetry (CV) of [PVS/Hb]n films showed a pair of well-defined and nearly reversible peaks at about - 0.28 V vs. SCE at pH 5.5, characteristic of Hb heme Fe(III)/Fe(II) redox couple. The process of (PVS/Hb) bilayer growth was monitored and confirmed by CV, X-ray photoelectron spectroscopy (XPS) and UV-Vis spectroscopy. While the amount of Hb adsorbed in each bilayer was the same, the amount of electroactive Hb in each bilayer decreased dramatically with increase of the number of bilayer, and electroactivity was just extended to 8 [PVS/Hb] bilayers. CVs of [PVS/Hb]8 films maintained stable in buffers containing no Hb. Positions of Soret band of Hb in [PVS/Hb]n films grown on transparent glass slides suggest that Hb in the films keeps its secondary structure similar to its native state in a wide pH range. Trichloroacetic acid and nitrite were catalytically reduced by [PVS/Hb]8 films with significant lowering of the electrode potential required.

Catalysis↗

Direct electron transfer for hemoglobin in biomembrane-like dimyristoyl phosphatidylcholine films on pyrolytic graphite electrodes.

Stable thin films made from dimyristoyl phosphatidylcholine (DMPC) with incorporated hemoglobin (Hb) on pyrolytic graphite (PG) electrodes were characterized by electrochemical and other techniques. Cyclic voltammetry (CV) of Hb-DMPC films showed a pair of well-defined and nearly reversible peaks at about -0.27 V vs. saturated calomel electrode (SCE) at pH 5.5, characteristic of Hb heme Fe(III)/Fe(II) redox couple. The electron transfer between Hb and PG electrodes was greatly facilitated in DMPC films. Apparent heterogeneous rate constants (ks) were estimated by fitting square wave voltammograms of Hb-DMPC films to a model featuring thin layer behavior and dispersion of formal potentials for redox center. The formal potential of Hb heme Fe(III)/Fe(II) couple in DMPC films shifted linearly between pH 4.5 to 11 with a slope of -48 mV pH-1, suggesting that one proton is coupled to each electron transfer in the electrochemical reaction. Soret absorption band positions suggest that Hb retains a near native conformation in DMPC films at medium pH. Differential scanning calorimetry (DSC) showed the phase transition for DMPC and Hb-DMPC films, suggesting DMPC has an ordered multibilayer structure. Trichloroacetic acid (TCA) was catalytically reduced by Hb-DMPC films with significant decreases in the electrode potential required.

Algorithms↗