PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “PERCHLORIC ACID”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Interference of heparin in plasma levocarnitine determination with radioenzyme assay.

This paper describes the interference of heparin (CAS 9005-49-6) in whole plasma used for free and total levocarnitine (L-carnitine, CAS 541-15-1) analysis. Alkaline hydrolysis required for total L-carnitine measurement does not overcome the problem. The same interference is also present in long-chain acyl-L-carnitine assay, because heparin precipitates together with proteins and long-chain esters of L-carnitine in the acid insoluble fraction of perchloric acid treated plasma sample. In this case an appropriate cleaning of the sample is recommended before the assay.

Acetylcarnitine↗

Carcinoembryonic antigen in whole serum.

A microradioimmunoassay technique is described for detecting carcinoembryonic antigen (CEA) in whole serum. It differs from previous methods in being performed on 0·025 ml of whole serum instead of 5 ml of serum extracted with perchloric acid. The present assay was sufficiently sensitive to detect 85% of carcinomata, localized to the colon, but positive results occurred also with certain non-gastrointestinal cancers, chiefly lung and breast, and certain non-malignant diseases. Many of the latter sera, with the general exception of alcoholic cirrhosis and pancreatitis, gave negative results after extraction with perchloric acid. It is suggested that a direct assay for CEA in whole serum may permit testing of large numbers of sera by laboratories with facilities for radioimmunoassays.

Ammonium Sulfate↗

Nucleotide preparation from cells and determination of nucleotides by ion-pair high-performance liquid chromatography.

Procedures for the analysis of cellular purine and pyrimidine nucleotides are described. The commonly used perchloric acid and especially the trichloroacetic acid methods for nucleotide extraction interfere with ion-pair high-performance liquid chromatography, but we have developed such a system for the separation and determination of major cellular nucleotides in biological matrices, including tri-, di-, monophosphates, cAMP, cGMP, NAD, NADP, UDP-glucose and UDP-galactose. Compared with perchloric acid extraction, no degradation of the nucleotide standards used was observed with respect to triphosphates and other relatively unstable nucleotides. Cellular nucleotides were extracted by lysing cells in a hypotonic buffer containing an ion-pair reagent (tetrabutylammonium hydrogen-sulphate) to decrease enzymic degradation of nucleotides in combination with ultrafiltration of the cell lysate to remove compounds of higher molecular mass, for example enzymes. This method is a simple and reproducible procedure for investigating nucleotide pools in cells.

Animals↗

15 beta-hydroxysteroids (Part V). Steroids of the human perinatal period: the synthesis of 3 beta, 15 beta, 17 alpha-trihydroxy-5-pregnen-20-one from 15 beta, 17 alpha-dihydroxy-4-pregnen-3,20-dione.

A simple three-step synthetic method is reported on the conversion of delta 4-3-ketosteroids to the corresponding 3 beta-hydroxy-delta 5-steroid analogues. 17 alpha-Hydroxy-4-pregnen-3,20-dione (10a) was used as a model to develop a method for the synthesis of 3 beta, 17 alpha-dihydroxy-5-pregnen-20-one (16). The major problem being the synthesis of 3,17 alpha-diacetoxy-3,5-pregnadien-20-one (14) was solved by acetylating using a mixture of acetic anhydride and perchloric acid. The conversion of 15 beta, 17 alpha-dihydroxy-4-pregnen-3, 20-dione (8), product of Penicillium citrinum fermentation, to the desired 3 beta,15 beta,17 alpha-trihydroxy-5-pregnen-20-one (1), is described using a modification of this method. Reaction of 8 with acetic anhydride and perchloric acid in ethyl acetate gave 3,15 beta,17 alpha-triacetoxy-3,5-pregnadien-20-one (17) which on reduction with sodium borohydride gave 5-pregnen-3 beta,15 beta,17 alpha, 20(S + R)-tetrols (18a and 18b); however, reduction of 17 with a mixture of sodium borohydride and potassium bicarbonate gave after basic hydrolysis with methanolic sodium hydroxide the desired product 3 beta,15 beta,17 alpha-trihydroxy-5-pregnen-20-one (1) in good yield (54%).

17-alpha-Hydroxypregnenolone↗

Direct fluorometric assay of catecholamine secretion from isolated bovine adrenal chromaffin cells.

The intrinsic fluorescence of catecholamines can be exploited for a simple and speedy fluorescence assay of secretion from bovine adrenal chromaffin cells. Catecholamines are separated from concomitantly secreted proteins by centrifugation in 0.4 M perchloric acid, and their fluorescence is measured directly in a conventional spectrofluorometer without chemical derivatization. Catecholamine release, assayed by this technique, is virtually identical to data obtained in parallel by the classical trihydroxyindole method. Intrinsic catecholamine fluorescence does not differentiate between epinephrine and norepinephrine. Interferences from small molecular weight compounds not precipitated in perchloric acid are rare, and can be accounted for using appropriate calibration curves.

Adrenal Medulla↗

One-step procedure for the determination of thymosin beta 4 in small tissue samples and its separation from other thymosin beta 4-like peptides by high-pressure liquid chromatography.

Thymosin beta 4 has been determined by a simple and fast one-step procedure in different tissues of rats. The tissues (1 to 40 mg) were disintegrated and deproteinized by homogenization in perchloric acid. After neutralization by potassium hydroxide the supernatant solution was used for determining thymosin beta 4 by reverse-phase HPLC without further manipulations. Not only does this procedure avoid artificial proteolysis as effectively as extraction of tissues by guanidinium chloride or boiling buffer, but it offers two further advantages. First, no additional steps--as for example desalting--are necessary prior to HPLC and thus the risk of losing thymosin beta 4 is eliminated. Using this procedure thymosin beta 4 is recovered quantitatively. The method is linear over the range 0.04 to 1.13 nmol and thymosin beta 4 is well separated from other thymosin beta 4-like peptides known to be present in mammals; i.e., thymosin beta Ala4, thymosin beta 9, thymosin beta 10, and thymosin beta Arg10. Second, the acid-insoluble pellet of the same extract can be used to determine the DNA content of the sample. Thus it is possible to relate thymosin beta 4 to DNA, which then allows comparing cells of different tissues and cell lines to one another. This procedure is also applicable to small peptides soluble in perchloric acid.

Amino Acid Sequence↗

Simple and rapid determination of serotonin and catecholamines in biological tissue using high-performance liquid chromatography with electrochemical detection.

Using the CNS of Lymnaea stagnalis a method is described for the rapid analysis of neurotransmitters and their metabolites using high performance liquid chromatography coupled with electrochemical detection. Tissue samples were homogenised in ice-cold 0.1 M perchloric acid and centrifuged. Using a C(18) microbore column the mobile phase was maintained at a flow rate of 100 microl/min and consisted of sodium citrate buffer (pH 3.2)-acetonitrile (82.5:17.5, v/v) with 2 mM decane-sulfonic acid sodium salt. The potential was set at +750 mV versus Ag|AgCl reference electrode at a sensitivity of 50 nA full scale deflection. The detection limit for serotonin was 11.86 ng ml(-1) for a 5 microl injection. Preparation of tissue samples in mobile phase reduced the response to dopamine and serotonin compared with perchloric acid. In addition it was found that the storage of tissue samples at -20 degrees C caused losses of dopamine and serotonin. As a result of optimising the sample preparation and mobile phase the total time of analysis was substantially reduced resulting in a sample preparation and assay time of 15-20 min.

Animals↗

Quantification of intracellular levels of cyclic ADP-ribose by high-performance liquid chromatography.

A combined two-step high-performance liquid chromatographic (HPLC) method was developed for the analysis of endogenous levels of cyclic adenosine diphosphoribose (cADPR) in cell extracts. The detection sensitivity for cADPR was about 10 pmol. Linearity of the HPLC detection system was demonstrated in the range of 10 pmol up to 2 nmol. The method was validated in terms of within-day and between-day reproducibility of retention times and peak areas of standard nucleotides. The method was applied to the analysis of endogenous cADPR in human T cell lines. Sequential separation of perchloric acid extracts from cells on strong anion-exchange and reversed-phase ion-pair HPLC resulted in a single symmetrical peak co-eluting with standard cADPR. The identity of this endogenous material was further confirmed by its ability to be converted to ADPR upon heating the cell samples at 80 degrees C for 2 h. Recoveries of the combined perchloric acid extraction-HPLC analysis procedures were 48.3 +/- 10.2%. The determined intracellular concentrations of cADPR in quiescent Jurkat and HPB. ALL human T cells were 198 +/- 41 and 28 +/- 9 pmol/10(8) cells, respectively. In conclusion, a non-radioactive HPLC method presenting a specificity and sensitivity suitable for precise quantification of cADPR in cell extracts was developed.

Adenosine Diphosphate Ribose↗

High-resolution magic angle spinning MRS of breast cancer tissue.

High-resolution magic angle spinning (HR MAS) may develop into a new diagnostic tool for studying intact tissue samples, and several types of cancer have been investigated with promising results. In this study HR MAS spectra of breast cancer tissue from 10 patients have been compared to conventional high-resolution spectra of perchloric acid extracts of the same tissue type. The HR MAS spectra show resolution comparable to spectra of extracts, and two-dimensional techniques lead to identification of a majority of the constituents. More than 30 different metabolites have been detected and assigned. To our knowledge this is the most detailed assignment of biochemical components in intact human breast tissue. The spectra of intact breast cancer tissue differ from perchloric acid extracts by the presence of lipids and fewer signals in the low field region. HR MAS analysis of intact breast tissue specimens is a rapid method, providing spectra with resolution where relative quantification of the majority of the detected metabolites is possible.

Adult↗

Improved radiochemical assay for carnitine and its derivatives in plasma and tissue extracts.

We describe the measurement of carnitine and short-chain and long-chain acylcarnitines in perchloric acid extracts of liver and muscle. [1-14C]Acetyl-CoA is used, and labeled acetylcarnitine is measured with a sensitivity of less than 1 to 50 nmol of L-carnitine per 50-microliter sample. Samples frozen at -20 degrees C lost no carnitine during several months. Analytical recovery of carnitine (5 nmol) added to 50-microliter perchloric acid extracts of liver was 103 +/- 2%. This method may be suitable for clinical applications such as screening patients with muscle and metabolic disorders.

Acetylcarnitine↗

Inositol phosphates in rat atria and the importance of the extraction procedure.

The nature of the inositol phosphates present in adult rat left atria have been examined. Trichloroacetic acid extracts of [3H] inositol-labelled left atria contained the 1 (or 3)-, 2- and 4-isomers of inositol monophosphate, inositol-1,4-bisphosphate, and inositol-1,4,5-trisphosphate. Addition of noradrenaline increased all of these isomers. However, even in the presence of noradrenaline, there was no evidence for the presence of inositol-1,3,4,5-tetrakisphosphate or its dephosphorylation products including inositol-1,3,4-trisphosphate and the 1,3- and 3,4-isomers of inositol bisphosphate. Total accumulation of inositol phosphates in the presence of LiCl was 98% accounted for by dephosphorylation of inositol-1,4,5-trisphosphate and its cyclic isomer. These data indicate that, in intact left atria, metabolism of inositol-1,4,5-trisphosphate is by dephosphorylation and that significant activity of the phosphorylation pathway is not present. When extractions were performed using either acidified chloroform-methanol or perchloric acid, other [3H] inositol-labelled compounds were detected in atrial extracts. One of these chromatographed with ATP and might be mistaken for inositol-1,3,4-trisphosphate if co-chromatography with ATP was used to identify that compound. Another compound had a similar, but not identical chromatographic profile to inositol-1,3,4,5-tetrakisphosphate and is thus likely to be mistaken for that compound. In addition, perchloric acid extraction caused phosphate group migration generating extra isomers of the inositol phosphates and other unidentified [3H]-labelled compounds. Such extraction artifacts are likely especially problematic in studies of intact heart tissue because of the time required to effectively homogenize the tissue. These findings demonstrate the need for caution in interpreting data relating to estimations of inositol phosphates in intact heart tissue.

Animals↗

Blood glucose, lactate, pyruvate, glycerol, 3-hydroxybutyrate and acetoacetate measurements in man using a centrifugal analyser with a fluorimetric attachment.

Methods are described for the analysis of glucose, lactate, pyruvate, alanine, glycerol, 3-hydroxybutyrate and acetoacetate in perchloric acid extracts of human blood, using the Cobas Bio centrifugal analyser fitted with a fluorimetric attachment. Intra-assay and inter-assay coefficients of variation ranged from 1.9 to 7.9% and from 1.0 to 7.2% respectively. Correlation coefficients ranged from 0.96 to 0.99 against established continuous-flow and manual spectrophotometric methods. All seven metabolites can be measured using a single perchloric acid extract of 20 microliter of blood. The versatility of the assays is such that as little as 100 pmol pyruvate, 3-hydroxybutyrate or as much as 15 nmol glucose can be measured in the same 20 microliter extract.

Acetoacetates↗

Detecting early response to cyclophosphamide treatment of RIF-1 tumors using selective multiple quantum spectroscopy (SelMQC) and dynamic contrast enhanced imaging.

The purpose of this study was to develop a reliable, noninvasive method for early detection of tumor response to therapy that would facilitate optimization of treatment regimens to the needs of the individual patient. In the present study, the effects of cyclophosphamide (Cp, a widely used alkylating agent) were monitored in a murine radiation induced fibrosarcoma (RIF-1) using in vivo (1)H NMR spectroscopy and imaging to evaluate the potential of these techniques towards early detection of treatment response. Steady-state lactate levels and Gd-DTPA uptake kinetics were measured using selective multiple quantum coherence (Sel-MQC) transfer spectroscopy and dynamic contrast enhanced imaging, respectively in RIF-1 tumors before, 24 and 72 h after 300 mg/kg of Cp administration. High-resolution (1)H NMR spectra of perchloric acid extracts of the tumor were correlated with lactate and glucose concentrations determined enzymatically. In vivo NMR experiments showed a decrease in steady-state lactate to water ratios (5.4 +/- 1.6 to 0.6 +/- 0.5, p < 0.05) and an increase in Gd-DTPA uptake kinetics following treatment response. The data indicate that decreases in lactate result from decreased glycolytic metabolism and an increase in tumor perfusion/permeability. Perchloric acid extracts confirmed the lower lactate levels seen in vivo in treated tumors and also indicated a higher glycerophosphocholine/phosphocholine (GPC/PC) integrated intensity ratio (1.39 +/- 0.09 vs 0.97 +/- 0.04, p < 0.01), indicative of increased membrane degradation following Cp treatment. Steady-state lactate levels provide metabolic information that correlates with changes in tumor physiology measured by Gd-DTPA uptake kinetics with high spatial and temporal resolution. Both of these parameters may be useful for monitoring early tumor response to therapy.

Animals↗

Altered organic anion and osmolyte content and excretion in rat polycystic kidney disease: an NMR study.

Polycystic kidney disease (PKD) is the fourth most common cause of end-stage renal disease and the most common potentially lethal inherited disease in humans. Early identification of carriers of dominant PKD in the absence of genetic markers is problematic in both humans and the Han:SPRD-cy/+ rat, a model of PKD that shares many features of human disease. We undertook a proton magnetic resonance imaging (MRI) study of young Han:SPRD-cy/+ and unaffected Han:SPRD(-)+/+ animals to determine whether carrier status could be identified based upon image appearance or signal characteristics. Affected animals demonstrated significant prolongation of longitudinal relaxation time (T1) and transverse relaxation time (T2) in both cystic renal cortex and noncystic renal medulla. Both of these measurements correlated significantly with whole kidney section tubular luminal space measurements, a correlate of water space, in the renal cortex, but only T1 in renal medulla showed a relationship to tubular luminal volume measured throughout the kidney. Urine and perchloric acid kidney extracts were studied using proton nuclear magnetic resonance (1H-NMR) spectroscopy to test the hypothesis that imaging differences implied specific urinary and tissue biochemical differences between affected and normal animals. 1H-NMR spectra of urine from cy/+ animals showed significantly increased excretion of alanine, citrate, succinate, and, 2-oxoglutarate but not methylamine compounds compared with +/+ animals. 1H-NMR spectra of aqueous perchloric acid kidney extracts confirmed reduced concentrations of the above ions and others involved in the citric acid cycle, as well the osmolytes betaine, taurine, and glycerophosphocholine PKD in the Han:SPRD-cy/+ rat is associated with distinct early MRI changes and alterations in urinary and tissue levels of organic anions and osmolytes.

Animals↗

31P magnetic resonance of intact endocrine tissue: adrenal glands of dogs.

Intact dog adrenal glands were examined for their phosphate profiles in the 31P nuclear magnetic resonance spectrometer at 36.43 MHz at 31 degrees, and the resultant spectra were compared to those obtained from perchloric acid extracts of the same endocrine tissue. The adrenal gland presents a unique organ for whole tissue spectroscopy in that its phosphate profile shows a number of features which have not been previously observed in similar phosphate profiles obtained from other intact tissue preparations. A number of prominant resonances are observed in the intact adrenal gland which arise from phosphorus-containing substances that are not extractable with perchloric acid. The 31P shifts of these resonances indicate that they may arise from phosphorylated proteins and membrane phospholipids.

Adenine Nucleotides↗

Serum alanine assay with an enzymic micromethod (L-alanine dehydrogenase).

L-Alanine was measured by an enzymic micromethod in serum after treatment with perchloric acid, as well as after ultrafiltration through collodium membrane filters. Serum L-alanine was also determined by an automated column chromatographic technique. Using the enzymic method, spuriously increased L-alanine levels could be obtained due to the absorbent reaction between hydrazine and NAD-containing reagents. It could be shown that this absorbent reaction depends on the pH value of the test solution. In contrast to supernatant diluted by perchloric acid, ultrafiltrates gave L-alanine data equivalent to those by column chromatography, since conditions of reaction time and pH value could be kept identical for blank, standard and ultrafiltrate solutions.

Adult↗

In vitro 31P-magnetic resonance spectroscopy of muscle extracts in malignant hyperthermia-susceptible patients.

BACKGROUND: It was recently suggested that malignant hyperthermia-susceptible (MHS) patients could have an elevated peak of phosphodiesters in leg muscles using in vivo phosphorus magnetic resonance spectroscopy. In the current study, analysis of the phosphodiesters of muscle extracts of MHS and malignant hyperthermia-negative patients was performed using in vitro phosphorus magnetic resonance spectroscopy to chemically identify and to compare the muscle concentrations of water-soluble compounds between the two groups with respect to the muscle fiber type composition. METHODS: Perchloric acid extracts of the vastus medialis muscle of seven MHS patients and ten malignant hyperthermia-negative patients on the basis of the European malignant hyperthermia contracture test were subjected to in vitro phosphorus magnetic resonance spectroscopy carried out at 9.4 T. In addition, chemical identification of the phosphodiester region and histologic examination of the muscle specimens were performed. RESULTS: The peak in the phosphodiester region was assigned to glycerophosphorylcholine. Muscle perchloric acid extracts of MHS patients had a significantly (P < 0.05) higher glycerophosphorylcholine to the sum of phosphocreatine and inorganic phosphate (glycerophosphorylcholine/ [phosphocreatine +inorganic phosphate]) value than those of malignant hyperthermia-negative patients. Neither a difference in the fiber type composition between the two groups nor any specific myopathy were found. CONCLUSIONS: In the absence of histologic differences between muscle specimens of MHS and malignant hyperthermia-negative patients, these results could suggest that glycerophosphorylcholine could be a marker of an impairment in the phospholipid metabolism in the skeletal muscle of MHS patients.

Adolescent↗

Metabolic signatures associated with a NAD synthesis inhibitor-induced tumor apoptosis identified by 1H-decoupled-31P magnetic resonance spectroscopy.

PURPOSE: Attempts to selectively initiate tumor cell death through inducible apoptotic pathways are increasingly being exploited as a potential anticancer strategy. Inhibition of NAD+ synthesis by a novel agent FK866 has been recently reported to induce apoptosis in human leukemia, hepatocarcinoma cells in vitro, and various types of tumor xenografts in vivo. In the present study, we used 1H-decoupled phosphorus (31P) magnetic resonance spectroscopy (MRS) to examine the metabolic changes associated with FK866 induced tumor cell death in a mouse mammary carcinoma. EXPERIMENTAL DESIGN: Induction of apoptosis in FK866-treated tumors was confirmed by histology and cytofluorometric analysis. FK866-induced changes in mammary carcinoma tumor metabolism in vivo were investigated using 1H-decoupled 31P MRS. To discern further the changes in metabolic profiles of tumors observed in vivo, high-resolution in vitro 1H-decoupled 31P MRS studies were carried out with perchloric acid extracts of mammary carcinoma tumors excised after similar treatments. In addition, the effects of FK866 on mammary carcinoma tumor growth and radiation sensitivity were studied. RESULTS: Treatment with FK866 induced a tumor growth delay and enhanced radiation sensitivity in mammary carcinoma tumors that was associated with significant increases in the 31P MR signal in the phosphomonoester region and a decrease in NAD+ levels, pH, and bioenergetic status. The 31P MRS of perchloric acid extracts of treated tumors identified the large unresolved signal in the phosphomonoester region as the resultant of resonances originating from intermediates of tumor glycolysis and guanylate synthesis in addition to alterations in pyridine nucleotide pools and phospholipid metabolism. CONCLUSION: The present results suggest that FK866 interferes with multiple biochemical pathways that contribute to the increased cell death (apoptosis) and subsequent radiation sensitivity observed in the mammary carcinoma that could be serially monitored by 31P MRS.

Acrylamides↗