PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Q-method for high-resolution, whole-cell patch-clamp impedance measurements using square wave stimulation.

High-resolution measurements of cell impedance provide invaluable information on various cellular processes such as exocytosis, ion channel gating, or fertilization. The best recent techniques, although achieving impedance resolution at theoretical limits, have limited applicability due to their inherent constrains and high complexity. We report here a simple method of high-resolution impedance measurement, dubbed as the Q-method, based on measurement of a charge by integrating the cell current during square wave stimulation and on its decomposition into specific components related to segments of the voltage stimulus. Simple relations were derived allowing very fast and direct estimation of cell impedance parameters. The major advantages of the Q-method are its inherently low sensitivity to low-pass filtering, rejection of periodic interference signals, automatic on-the-fly adjustment of the stimulation frequency for the highest capacitance resolution, and simultaneous high-resolution low-crosstalk monitoring of membrane resistance, series resistance and parasitic capacitance in addition to membrane capacitance. Implementation of the Q-method is straightforward with any patch-clamp setup and any cell type. Theoretical grounds of the Q-method, including its resolution and the noise of individual parameters, are developed and experimentally verified.

Cell Membrane↗

Resolution and accuracy in two dimensional echocardiography.

The resolution and accuracy of commercially available two dimensional echocardiographic systems were tested by imaging two types of in vitro test objects. One consisted of a series of fine parallel threads spaced at known intervals and the other was a tissue phantom in which a series of holes of known size had been cut. The echocardiographic systems tested included a mechanical single element sector scanner, a three element rotary sector scanner and a phased array system. Azimuthal resolution, lateral resolution and accuracy of horizontal distance measurements were assessed at depths of 2 and 6 cm. For each system, azimuthal resolution was better than lateral resolution, especially when assessed with use of the parallel threads. When the tissue phantom was imaged, the best resolution (2 mm in azimuthal and lateral directions) was obtained with the highest frequency transducer tested (3.5 MHz). The apparent size of a tissue defect was sensitive to gain settings, especially at a depth of 2 cm with lower frequency transducers; at a depth of 6 cm, echographic measurements of defect size were accurate to within 2.5 mm. Recent applications of two dimensional echocardiography require near the apparent limits of current equipment. It is recommended that the highest frequency transducer and lowest possible gain settings be used in these situations.

Cardiomyopathies↗

Resolution of the enantiomers of various alpha-substituted ornithine and lysine analogs by high-performance liquid chromatography with chiral eluant and by gas chromatography on Chirasil-Val.

A reversed-phase high-performance liquid chromatography method, with L-proline and copper as chiral mobile phase, is described for the enantiomeric resolution of various alpha-substituted ornithine and lysine analogs. Although ornithine gives no separation with the chiral eluant used, excellent resolutions are obtained for various alpha-alkyl-, alpha-halogenomethyl-, alpha-vinyl-, and alpha-ethynyl-substituted ornithines. Similar separations are also observed for the dehydroornithine and lysine analogs. Gas chromatography on a chiral stationary phase, Chirasil-Val, allows the resolution of the ornithine and lysine analogs after derivatization into the monofluoroacyl derivatives of their corresponding lactams. No resolution or only a poor resolution is obtained by GC on Chirasil-Val for the dehydroornithine analogs as their di-N-perfluoroacyl alkyl esters. The chiral eluant HPLC procedure is easily scaled up for the semipreparative resolution of several ornithine analogs, i.e., alpha-fluoromethylornithine, alpha-difluoromethylornithine, alpha-chlorofluoromethylornithine, and alpha-fluoromethyldehydroornithine, which are known as potent ornithine decarboxylase inhibitors in vitro and in vivo.

Chromatography, Gas↗

High resolution autoradiography at the regional topographic level with [14C]2-deoxyglucose and [3H]2-deoxyglucose.

After injection of 2-deoxyglucose (2-DG) labeled with tritium or carbon-14, autoradiograms were produced by thaw-mounting 4 micron frozen sections of rat brains on nuclear emulsion-coated slides. The results show that the distribution of radioactivity among different brain regions was similar and that the resolution at the regional topographical level was virtually identical for both compounds. The resolution obtained with the thaw-mounting of thin frozen sections onto nuclear emulsion was considerably greater than the resolution demonstrated in published results in the literature, when carbon-14 or tritium-labeled 2-deoxyglucose were used with 20 micron frozen sections and X-ray film or tritium-sensitive film. The results indicate that section thickness, detection medium and intimacy of contact between section and photographic emulsion influence resolution. At the regional level, the detection medium apparently influences resolution to a greater extent than the energy differences of the beta particles emitted from 14C or 3H. Although diffusion of radiolabeled 2-deoxyglucose and metabolites during the thaw-mounting process precludes single cell resolution of these autoradiograms, the improvement of visualizing regional topographic detail demonstrates that the described technique is a valuable approach with which to study regional 2-DG uptake.

Animals↗

Emission microscopy and related techniques: resolution in photoelectron microscopy, low energy electron microscopy and mirror electron microscopy.

A unified treatment of the resolution of three closely related techniques is presented: emission electron microscopy (particularly photoelectron microscopy, PEM), low energy electron microscopy (LEEM), and mirror electron microscopy (MEM). The resolution calculation is based on the intensity distribution in the image plane for an object of finite size rather than for a point source. The calculations take into account the spherical and chromatic aberrations of the accelerating field and of the objective lens. Intensity distributions for a range of energies in the electron beam are obtained by adding the single-energy distributions weighted according to the energy distribution function. The diffraction error is taken into account separately. A working resolution is calculated that includes the practical requirement for a finite exposure time, and hence a finite non-zero current in the image. The expressions for the aberration coefficients are the same in PEM and LEEM. The calculated aberrations in MEM are somewhat smaller than for PEM and LEEM. The resolution of PEM is calculated to be about 50 A, assuming conventional UV excitation sources, which provide current densities at the specimen of 5 x 10(-5) A/cm2 and emission energies ranging up to 0.5 eV. A resolution of about 70 A has been demonstrated experimentally. The emission current density at the specimen is higher in LEEM and MEM because an electron gun is used in place of a UV source. For a current density of 5 x 10(-4) A/cm2 and the same electron optical parameters as for PEM, the resolution is calculated to be 27 A for LEEM and 21 A for MEM.

Mathematics↗

Prospects for using an IVEM with a FEG for imaging macromolecules towards atomic resolution.

Specimen preparation and imaging techniques for biological macromolecules have been improved to the point where attention to the electron-optical imaging conditions becomes a significant factor for achieving high resolution. A field emission gun (FEG) can provide an illumination source with a better spatial and temporal coherence suitable for imaging near atomic resolution. Our computational analysis of carbon film images taken between Scherzer focus and 1.1 microns underfocus (20x Scherzer focus) with the Hitachi 200 kV microscope with a cold field emission gun shows detectable contrast beyond 3.5 A resolution. In biological imaging, a large defocus is often used to optimize the low-resolution contrast in order to facilitate the subsequent steps in computer reconstruction. An intermediate-voltage electron microscope (IVEM) would optimize the contrast at high resolution by reducing the temporal coherent effects. In theory, the IVEM would give a greater depth of field so that large macromolecular assemblies such as viruses and cellular structures can be interpreted and reconstructed reliably using the projection approximation. These experimental and theoretical considerations provide a rationale for designing a future IVEM with a FEG suitable for biological macromolecule imaging close to atomic resolution.

Fourier Analysis↗

Capillary zone electrophoresis of peptides: prediction of the electrophoretic mobility and resolution.

The determination of the pKa values of some selected peptides of similar size was performed by microtitration, which makes possible an accurate determination of the peptide charge as a function of the solution pH. Capillary zone electrophoresis separation of these peptides on modified capillaries at acidic pH showed that the electrophoretic mobility correlates with the peptide charge. This observation suggests that when an appropriate charge value is used, the basic electrophoretic equation is respected and, at least at a peptide charge value less than 1, the utilization of alternative semi-empirical predictions is not necessary. As a general rule, a peptide separation at acidic pH values is to be preferred to that at basic pH values. In fact, at basic pH a separation in the absence of both electroosmotic flow and of spurious interactions between the peptides and the inner wall of the capillary is difficult, owing to the instability of capillary modification. Further, from the differences in the peptide charge, a prediction of the best resolution as a function of the pH could be obtained; in fact, the resolution, for peptides of similar size and in the absence of electroosmotic flow, is connected to a simple equation, where the principal term depends on the effective charge of the peptides, which is a function of the pH of the solution and the pKa values of the peptides. The predictions of resolution at acidic pH agreed well with the experimental results; the spatial resolution measured in the separation of met- and leu-enkephalin was virtually coincident with the predicted resolution; in the case of a mixture of four model tetrapeptides of sequence GGNA, GGQA, GGDA and GGEA some anomalous results with respect to the predicted resolutions were observed. Nevertheless, an acceptable prediction can also be made in this case.

Amino Acid Sequence↗

Poly(ethyleneoxide) for high-resolution and high-speed separation of DNA by capillary electrophoresis.

Capillary electrophoresis (CE) with polyacrylamide gels has already been demonstrated to allow single-base resolution of single-stranded DNA. However, linear polyacrylamide is not an ideal matrix because of a high viscosity and difficulties in preparing the polymer with well defined pore sizes. Alternatively, poly(ethyleneoxide) (PEO) with a large range of molecular masses from 300,000 to 8,000,000 is available commercially. In addition, it is easy to prepare homogeneous solutions to provide highly reproducible separation performance with sufficient resolution. Single-base resolution of double-stranded DNA between 123 and 124 base pairs can be achieved by the use of homogeneous matrices prepared from PEO (2.5% M(r) 8,000,000), and even better resolution is achieved by using mixed polymer matrices. With further work, it should be possible to change the fractions and the total amounts of polymers to achieve even higher resolution for different samples with different size ranges of fragments. Another advantage of mixed polymer matrices is that relatively high resolution can be obtained while maintaining a relatively low viscosity compared to linear polyacrylamide with identical contents of formamide and urea, which makes it easier to fill these matrices into small capillaries.

DNA↗

Low resolution spin echo: a simple timesaving technique for MRI liver exams.

MR evaluation of the liver at mid-field strength requires relatively lengthy T2-weighted sequences (T2W) for differentiation of benign cavernous hemangiomas from malignant lesions. A short duration T2W, which maintains standard signal-to-noise ratio and also contrast relationships, can be easily implemented by increasing the pixel size in the phase-encoding direction (thus reducing spatial resolution) and proportionally decreasing the number of phase-encoding steps in the matrix (thus reducing acquisition time). Blinded interpretations of a quick (4 min), low resolution (3.4 mm x 1.7 mm pixel) T2W sequence (matrix 64 x 256, FOV 21.7 cm phase x 43.5 cm frequency) were compared to the 17 min standard resolution (1.7 mm x 1.7 mm) T2W sequence (256 x 256 matrix, FOV 43 x 43 cm) in 25 patients suspected of having liver metastasis. Lesions felt to be cavernous hemangiomas showed a 100% (24/24) agreement for interpreter "A" and 96% (22/23) agreement for interpreter "B" when 4 min low resolution T2W was compared to the standard 17 min sequence. Sensitivity (for all types of lesions) of the low resolution T2W sequence ranged from 100% (31/31) for interpreter "A" to 80% (28/35) for interpreter "B." Missed lesions (interpreter "B") were either partially obscured by excessive fat (wrap around) (N = 4), less than 1 cm in size (N = 2), or degraded by motion artifact (N = 1). Thus in many situations low resolution T2 may provide a substantial timesaving alternative to standard T2W particularly where T2W is used primarily for lesion classification in normal sized patients.

Adult↗

Improved endocardial border resolution during dobutamine stress echocardiography with intravenous sonicated dextrose albumin.

OBJECTIVES: The purpose of this study was to determine whether intravenous sonicated dextrose albumin could improve endocardial border resolution during dobutamine stress echocardiography. BACKGROUND: Sonicated albumin improves endocardial border resolution in patients undergoing exercise stress echocardiography. Because a sonicated mixture of albumin with dextrose results in better transpulmonary passage than sonicated albumin alone, this agent could be utilized to further improve endocardial border resolution during dobutamine stress echocardiography. METHODS: We gave intravenous injections of sonicated dextrose and albumin to 50 patients undergoing dobutamine stress echocardiography. Left ventricular video intensity, contrast agent persistence (in seconds), number of contrast agent-enhanced cardiac cycles and improvement in endocardial border resolution were assessed from the apical four-chamber view at baseline, low dose (10 micrograms/kg body weight per min) and peak dobutamine infusion. RESULTS: There was significantly better left ventricular peak video intensity at peak dobutamine infusion than after the same injection at baseline (p < 0.005, analysis of variance). The number of contrast agent-enhanced cardiac cycles in the left ventricular cavity was also significantly longer at peak infusion. Endocardial border resolution was improved (mainly in lateral segments) in 93% of patients at low dose and 95% of patients at peak infusion. CONCLUSIONS: Intravenous sonicated dextrose albumin improves endocardial border resolution during dobutamine stress echocardiography.

Aged↗

Time course of resolution of persistent air leak in spontaneous pneumothorax.

Persistent air leak (PAL) following tube drainage for spontaneous pneumothorax (SP) is a potentially troublesome complication. The optimum time to intervene surgically is not known. We therefore investigated the rate of resolution of PAL (defined as continued air leak at 2 days after tube insertion) in patients treated medically. We retrospectively reviewed the records of 214 patients presenting with SP over 5 yr. One hundred and forty-two (67%) had tube drainage and in 73 (51%) of these a PAL developed. Overall median time to resolution in the 43 patients with PAL treated medically was 8 days from tube insertion, but PAL resolution was longer in those with underlying lung disease (n = 19) than those without such disease (11 days vs. 7 days, P = 0.05). In patients with normal lungs 20/24 had resolved by 9 days but subsequently the rate of resolution was much slower. In those with abnormal lungs only 8/19 had resolved by 9 days (P < 0.05 compared with those with normal lungs) but the rate of resolution in such patients appeared to change little subsequently. The size of the initial SP did not influence the rate of resolution of PAL. For patients with PAL and normal lungs, surgery at 7-9 days from tube insertion would provide a reasonable opportunity for the PAL to resolve with medical treatment. For those with underlying lung disease there is no clear optimal time and decisions need to be taken on an individual basis.

Adolescent↗

Resolution prediction and optimization of temperature programme in comprehensive two-dimensional gas chromatography.

A model is developed for predicting the resolution of interested component pair and calculating the optimum temperature programming condition in the comprehensive two-dimensional gas chromatography (GC x GC). Based on at least three isothermal runs, retention times and the peak widths at half-height on both dimensions are predicted for any kind of linear temperature-programmed run on the first dimension and isothermal runs on the second dimension. The calculation of the optimum temperature programming condition is based on the prediction of the resolution of "difficult-to-separate components" in a given mixture. The resolution of all the neighboring peaks on the first dimension is obtained by the predicted retention time and peak width on the first dimension, the resolution on the second dimension is calculated only for the adjacent components with un-enough resolution on the first dimension and eluted within a same modulation period on the second dimension. The optimum temperature programming condition is acquired when the resolutions of all components of interest by GC x GC separation meet the analytical requirement and the analysis time is the shortest. The validity of the model has been proven by using it to predict and optimize GC x GC temperature programming condition of an alkylpyridine mixture.

Chromatography, Gas↗

Sequential resolution of fragmented visual percepts: experimental investigation of a subject's perceptual experience after a right medial temporal stroke.

This report concerns the fragmented visual percepts in a woman, TR, following a right entorhinal-perirhinal infarct. In a previous report, Weddell [Weddell, R. A. (2005). A visual disorder producing highly selective deletion of recurring letters. Cortex, 41, 471-485] linked TR's highly selective tendency to delete recurrent letters with her fragmented percepts. The conflation of same-identity form elements was attributed to anterior extrastriate damage, which reduced the amount of information sustainable in fully resolved visual percepts, and the present experimental investigation of her subjective account of segment formation and resolution completes the story. She said that complex objects and long words first appeared as blurred regions, which sometimes included form elements. It is argued that figure-centred attentional mechanisms subdivided this blurred region into up to 3-4 parts. String length, lexical status (word vs. nonword), and background colour and/or luminance determined fragment length. Two rules described the fragment resolution sequence: largest segments usually resolved first, left-to-right resolution accounting for a few sequences. This resolution sequence occurred when stimuli were exposed too briefly for saccadic exploration, implicating endogenous attentional shifts. Experiment 4 confirmed TR's assertion that spatial, orthographic, and phonological information were stored during the fragment resolution process. Moreover, TR exerted considerable voluntarily control over the fragment resolution sequence and some influence over fragment length. Finally, these findings were interpreted in terms of an extended version of a neural network model of vision largely derived from nonhuman primate studies.

Adult↗

High resolution mechanical function in the intact porcine heart: mechanical effects of pacemaker location.

The necessity to quantify the mechanical function with high spatial resolution stemmed from the advancement of myocardial salvaging techniques. Since these therapies are localized interventions, a whole field technique with high spatial resolution was needed to differentiate the normal, diseased, and treated myocardium. We developed a phase correlation algorithm for measuring myocardial displacement at high spatial resolution and to determine the regional mechanical function in the intact heart. Porcine hearts were exposed and high contrast microparticles were placed on the myocardium. A pressure transducer, inserted into the left ventricle, synchronized the pressure (LVP) with image acquisition using a charge-coupled device camera. The deformation of the myocardium was measured with a resolution of 0.58+/-0.04 mm. Within the region of interest (ROI), regional stroke work (RSW), defined as the integral of LVP with respect to regional area, was determined on average at 21 locations with a resolution of 27.1+/-2.7 mm2. To alter regional mechanical function, the heart was paced at three different locations around the ROI. Independent of the pacemaker location, RSW decreased in the ROI. In addition, a gradient of increasing RSW in the outward direction radiating from the pacemaker was observed in all pacing protocols. These data demonstrated the ability to determine regional whole field mechanical function with high spatial resolution, and the significant alterations induced by electrical pacing.

Animals↗

The spatial resolutions of the apposition compound eye and its neuro-sensory feature detectors: observation versus theory.

For 100 years three ideas dominated efforts to understand the apposition compound eye. In Müller's theory, the eye viewed the panorama through an array of little windows without overlaps and without gaps, with no details within windows. Spatial resolution then depended on the interommatidial angle (Deltaphi) and the number of ommatidia. In the second proposal, the insect detected the temporal modulation of the light, which was limited by the aperture of the lens and the wavelength, assuming good focus. Modulation is the change of intensity in the receptor, usually caused by motion of a spatial contrast in the stimulus. Thirdly, motion was detected from the successive temporal modulations at adjacent visual axes. Recently, two more principles arose. The light-sensitive elements, called rhabdomeres, project through the nodal point of the lens to the outside world, and the resolution was limited by their grain size, like the pixels in a digital camera. Finally, detection of contrast and colour was limited by the signal/noise ratio (SNR) which was improved by brighter light and more visual pigment. These five physical principles provide satisfying explanations of eye function but they all originated from theory. Actual measurements of resolution depend on the operation of the test. The visual system of the honeybee recognizes a limited variety of simple cues, but there is no evidence that the pattern of ommatidial stimulation is re-assembled, or even seen. The known cues are: the temporal modulation of groups of receptors, the direction and angular velocity of motion, some measure of the spatial disruption of the pattern or the length of edge (related to spatial frequency and contrast), colour, the intensity, the position of the centre and the size of large well-separated areas of black or colour, the angle of orientation of a bar or grating, radial or tangential edges, and bilateral symmetry. Neurons connected to more than two adjacent ommatidia collaborate in the detection of cues, and the resolution depends on the neuro-sensory feature detectors at work at the time. Although some behavioural and electrophysiological measurements give a spatial resolution similar to the interommatidial angle, different spatial properties of neuro-sensory detectors predominate at different light intensities and with a diurnal rhythm. During the long history of this topic, the belief that the resolution ought to be Deltaphi has frequently been overturned by experimental measurement.

Animals↗

Flexible multi-scale fitting of atomic structures into low-resolution electron density maps with elastic network normal mode analysis.

A novel method is presented for the quantitative flexible docking of high-resolution structure into low-resolution maps of macromolecular complexes from electron microscopy. This method uses a linear combination of low-frequency normal modes from elastic network description of the molecular framework in an iterative manner to deform the structure optimally to conform to the low-resolution electron density map. The methodology utilizes gradient following techniques in collective normal modes to locally optimize the overall correlation coefficient between computed and measured electron density. To evaluate the performance of our approach, several proteins, which undergo large conformational changes, have been studied. We demonstrate that refinement based on normal mode analysis provides an accurate and fast alternative for the flexible fitting of high-resolution structure into a low-resolution density map. Additionally, we show that lower resolution (multi-scale) structural models can be used for the normal mode searching in lieu of fully atomic models with little loss of overall accuracy.

Algorithms↗

Fast fitting of atomic structures to low-resolution electron density maps by surface overlap maximization.

The complexities of X-ray crystallography and NMR spectroscopy for large protein complexes, and the comparative ease of approaches such as electron microscopy mean that low-resolution structures are often available long before their atomic resolution equivalents. To help bridge this gap in knowledge, we present 3SOM: an approach for finding the best fit of atomic resolution structures into lower-resolution density maps through surface overlap maximization. High-resolution templates (i.e. partial structures or models for multi-subunit complexes) and targets (lower-resolution maps) are initially represented as iso-surfaces. The latter are used first in a fast search for transformations that superimpose a significant portion of the target surface onto the template surface, which is quantified as surface overlap. The vast search space is reduced by considering key vectors that capture local surface information. The set of transformations with the highest surface overlap scores are then re-ranked by using more sophisticated scores including cross-correlation. We give a number of examples to illustrate the efficiency of the method and its restrictions. For targets for which partial complexes are available, the speed and performance of the method make it an attractive complement to existing methods, as many different hypotheses can be tested quickly on a single processor.

Algorithms↗

Enhanced resolution for EPR imaging by two-step deblurring.

The broad spectrum of spin probes used for electron paramagnetic resonance imaging (EPRI) result in poor spatial resolution of the reconstructed images. Conventional deconvolution procedures can enhance the resolution to some extent but obtaining high resolution EPR images is still a challenge. In this work, we have implemented and analyzed the performance of a postacquisition deblurring technique to enhance the spatial resolution of the EPR images. The technique consists of two steps; noniterative deconvolution followed by iterative deconvolution of the acquired projections which are then projected back using filtered backprojection (FBP) to reconstruct a high resolution image. Further, we have proposed an analogous technique for iterative reconstruction algorithms such as multiplicative simultaneous iterative reconstruction technique (MSIRT) which can be a method of choice for many applications. The performance of the suggested deblurring approach is evaluated using computer simulations and EPRI experiments. Results suggest that the proposed procedure is superior to the standard FBP and standard iterative reconstruction algorithms in terms of mean-square-error (MSE), spatial resolution, and visual judgment. Although the procedure is described for 2D imaging, it can be readily extended to 3D imaging.

Algorithms↗