PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Single-sided membrane introduction mass spectrometry for on-line determination of semi-volatile organic compounds in air.

Construction, optimization, and testing of a novel single-sided configuration for a semi-permeable [poly(dimethylsiloxane); PDMS] membrane introduction system for mass spectrometry is described. On-line detection of semi-volatile organic compounds of environmental interest is shown, including lindane (a pesticide), hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) (an explosive), butylated hydroxytoluene (BHT) (an antioxidant), 1,2-dichlorobenzene, dimethylmethyl phosphonate (DMMP) (a chemical warfare agent simulant) and naphthalene. The technique has limits of detection in the sub-ppb range. with rise times of 4 to 7 s and fall times of 12 to 36 s and a response that is linear over 4 orders of magnitude (from 0.1 ppb to 1000 ppb for DMMP). The cycle time, from crude air sampling to acquisition of results, is approximately 1 min. No sample preparation is necessary.

Journal Article↗

Volatile organic compound emissions from latex paint--Part 2. Test house studies and indoor air quality (IAQ) modeling.

Emission models developed using small chamber data were combined with an Indoor Air Quality (IAQ) model to analyze the impact of volatile organic compound (VOC) emissions from latex paint on indoor environments. Test house experiments were conducted to verify the IAQ model's predictions. The agreement between model predictions and experimental measurements met the American Society for Testing and Materials criteria for model verification in the room with the source and met most of the requirements in other rooms. The major cause of disagreement between the model predictions and the experimental data in the test house appears to be an inadequate sink model.

Air Pollution, Indoor↗

SPME applied to the study of volatile organic compounds emitted by three species of Eucalyptus in situ. Solid-phase micro extraction.

Headspace solid-phase microextraction coupled to gas chromatography/ion trap mass spectrometry-65 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) was used to identify and monitor the emission patterns of biogenic volatile organic compounds from leaves of Eucalyptus dunnii, Eucalyptus saligna, and Eucalyptus citriodora in situ. Short extractions (1 min) were performed every 30 min for periods of 8-10 h during 24 days taking advantage of the high capacity of this porous polymer coating. Forty-two compounds were detected and 20 identified in the headspace of E. saligna leaves, and 19 of 27 compounds were identified in the headspace of E. dunnii leaves. The emission pattern of (E)-beta-ocimene and rose oxide suggests that they may play a bioactive role in Eucalyptus.

Acyclic Monoterpenes↗

Volatile organic compounds, polycyclic aromatic hydrocarbons and elements in the air of ten urban homes.

Ten homes were monitored at regular intervals from June 1994 through April 1995 as part of a Public Health Assessment in Southeast Chicago for exposure to volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), and elements. Simultaneous 24-h indoor and outdoor samples were collected. VOCs were and analyzed using USEPA Method TO-14 with Selected Ion Monitoring Mass Spectrometry (GC/MS). PAHs were analyzed using USEPA Method TO-13 with GC/MS. Elements were collected on quartz fiber filters and analyzed by Inductively Coupled Argon Plasma (ICP) spectroscopy or Graphite Furnace Atomic Absorption (GFAA). Continuous measurements of CO2 and temperature were recorded for each indoor sample. Twenty-four h total CO2 emissions were determined from occupancy and estimated gas stove usage and were moderately correlated (R2 = 0.19) with 24 h average indoor CO2 concentrations. Modeled 24-h air exchange rates ranged from 0.04 to 3.76 air changes h-1 (ACH), with mean of 0.52 ACH. Median particle penetration was 0.89. Emission rates were calculated for each pollutant sampled. Using a detailed housing survey and field sampling questionnaires, it was possible to evaluate associations between housing characteristics and source activities, and pollutant source rates. The data indicate that several predictor variables, including mothball storage, air freshner use, and cooking activities, are reasonable predictors for emission rates for specific pollutants in the homes studied.

Air Movements↗

Adsorption of volatile organic compounds by pecan shell- and almond shell-based granular activated carbons.

The objective of this research was to determine the effectiveness of using pecan and almond shell-based granular activated carbons (GACs) in the adsorption of volatile organic compounds (VOCs) of health concern and known toxic compounds (such as bromo-dichloromethane, benzene, carbon tetrachloride, 1,1,1-trichloromethane, chloroform, and 1,1-dichloromethane) compared to the adsorption efficiency of commercially used carbons (such as Filtrasorb 200, Calgon GRC-20, and Waterlinks 206C AW) in simulated test medium. The pecan shell-based GACs were activated using steam, carbon dioxide or phosphoric acid. An almond shell-based GAC was activated with phosphoric acid. Our results indicated that steam- or carbon dioxide-activated pecan shell carbons were superior in total VOC adsorption to phosphoric acid-activated pecan shell or almond shell carbons, inferring that the method of activation selected for the preparation of activated carbons affected the adsorption of VOCs and hence are factors to be considered in any adsorption process. The steam-activated, pecan shell carbon adsorbed more total VOCs than the other experimental carbons and had an adsorption profile similar to the two coconut shell-based commercial carbons, but had greater adsorption than the coal-based commercial carbon. All the carbons studied adsorbed benzene more effectively than the other organics. Pecan shell, steam-activated and acid-activated GACs showed higher adsorption of 1,1,1-trichloroethane than the other carbons studied. Multivariate analysis was conducted to group experimental carbons and commercial carbons based on their physical, chemical, and adsorptive properties. The results of the analysis conclude that steam-activated and acid-activated pecan shell carbons clustered together with coal-based and coconut shell-based commercial carbons, thus inferring that these experimental carbons could potentially be used as alternative sources for VOC adsorption in an aqueous environment.

Adsorption↗

Use of computer-assisted methods for the modeling of the retention time of a variety of volatile organic compounds: a PCA-MLR-ANN approach.

A hybrid method consisting of principal component analysis (PCA), multiple linear regressions (MLR), and artificial neural network (ANN) was developed to predict the retention time of 149 C(3)-C(12) volatile organic compounds for a DB-1 stationary phase. PCA and MLR methods were used as feature-selection tools, and a neural network was employed for predicting the retention times. The regression method was also used as a calibration model for calculating the retention time of VOCs and investigating their linear characteristics. The descriptors of the total information index of atomic composition, IAC, Wiener number, W, solvation connectivity index, X1sol, and number of substituted aromatic C(sp(2)), nCaR, appeared in the MLR model and were used as inputs for the ANN generation. Appearance of these parameters shows the importance of the dispersion interactions in the mechanism of retention. Comparison of the MLR and 5-2-1 ANN models indicates the superiority of the ANN over that of the MLR model. The values of 0.913 and 0.738 were obtained for the standard error of prediction set of MLR and ANN models, respectively.

Journal Article↗

Combining membrane extraction with mobile gas chromatography for the field analysis of volatile organic compounds in contaminated waters.

A mobile gas chromatographic device (Airmobtx HC 1000 monitor manufactured by Airmotec, Germany), originally designed for the analysis of benzene, toluene, ethylbenzene and xylenes (BTEX) in air, was connected to a flow cell for dynamic membrane extraction. Volatile organic compounds (VOCs) diffuse out of a water stream through a hollow fibre, are enriched onto sorption tubes integrated in the mobile device, and are then thermally desorbed and analysed by gas chromatography-flame ionisation detection. Battery operation of the device enables continuous on-site analysis of VOCs. Influences of the water flow-rate on system response and memory effects were investigated. The linear range of the method depends on the flow-rate of the water sample and did not exceed two orders of magnitude. The detection limits for trichloroethene, chlorobenzene and the BTEX compounds were found to be between 0.1 and 1.0 microg/l using a water flow-rate of 30 ml/min. Dynamic membrane extraction combined with the mobile gas chromatographic device was used for the on-site analysis of contaminated waters in the area of Leipzig.

Benzene↗

Bio-oxidation of airborne volatile organic compounds in an activated sludge aeration tank.

An activated sludge aeration tank (40 x 40 x 300 cm, width x length x height) with a set of 2-mm orifice air spargers was used to treat gas-borne volatile organic compounds (VOCs; toluene, p-xylene, and dichloromethane) in air streams. The effects of liquid depth (Z), aeration intensity (G/A), the overall mass-transfer rate of oxygen in clean water (KLaO2), the Henry's law constant of the tested VOC (H), and the influent gaseous VOC concentration (C0) on the efficiency of removal of VOCs were examined and compared with a literature-cited model. Results show that the measured VOC removal efficiencies and those predicted by the model were comparable at a G/A of 3.75-11.25 m3/m2 hr and C0 of approximately 1000-6000 mg/m3. Experimental data also indicated that the designed gas treatment reactor with KLaO2 = 5-15 hr(-l) could achieve > 85% removal of VOCs with H = 0.24-0.25 at an aerated liquid depth of 1 m and > 95% removal of dichloromethane with H = 0.13 at a 1-m liquid depth.

Air Pollution↗

The consequences of volatile organic compound mediated bacterial and fungal interactions.

Microbial interactions via infochemicals are fundamental to the development of spatial distribution and activity variations in ecosystems. Microorganisms produce a wide range of infochemicals, frequently secondary metabolites, most of which are soluble and many volatile. Volatile organic compounds (VOCs) have been identified in soil atmospheres and related to community structure and function. VOC profiles produced by microorganisms are consistent, relating to cultural conditions, environment and inputs, and so to population and function dynamics. VOC-mediated interactions can result in functional responses by the organisms involved that result in selective advantage to some community members. Positive, negative or neutral interactions can occur between a very wide range of soil bacteria and fungi. These effects include both stimulation and inhibition of growth, by 40 and 60%, respectively, and enzyme production. These effects are usually transient, e.g. removal of an antagonist is followed by complete recovery. Up- and down-regulation of gene expression, by mRNA and protein profiling has been demonstrated. VOCs have played an important role during the evolution of microorganisms in the context of their communities.

Bacteria↗

Influence of short-term exposure to airborne Der p 1 and volatile organic compounds on skin barrier function and dermal blood flow in patients with atopic eczema and healthy individuals.

BACKGROUND: Epidemiological studies indicate environmental pollutants to be involved in the increase in the prevalence of allergic diseases. In human exposure studies, volatile organic compounds (VOCs) have been shown to cause exacerbations of allergic asthma whereas, no data concerning atopic eczema (AE) are available. OBJECTIVE: We investigated the effect of airborne VOCs on the skin of patients with AE and controls in the presence or absence of house dust mite allergen, Der p 1. METHODS: In a double-blind crossover study, 12 adults with AE and 12 matched healthy volunteers were exposed on their forearms to Der p 1 and subsequently to a mixture of 22 VOCs (M22, 5 mg/m(3)) in a total body exposure chamber for 4 h. Transepidermal water loss (TEWL) and skin blood flow were measured in all subjects before, during and after exposure. Additionally, an atopy patch test (APT) with Der p 1 was applied to the skin after exposure. RESULTS: A significant increase in transepidermal water loss was observed 48 h after exposure to VOCs as compared with exposure with filtered air in all individuals (mean difference: +34%; 95% Confidence Interval: 7-69%). Prior Der p 1 exposure resulted in a significant rise of dermal blood flow after 48 h in patients with AE but not in controls. Six out of seven patients showed enhanced atopy patch test (APT) reactions to HDM allergen after previous exposure to VOCs. CONCLUSION: Our results show that exposure to VOCs - at concentrations commonly found in indoor environments - can damage the epidermal barrier and enhance the adverse effect of Der p 1 on sensitized subjects with AE. These findings may contribute to a better understanding of the mechanisms underlying the increase in prevalence and exacerbation of AE.

Adult↗

Characterization of volatile organic compounds (VOCs) and their sources in the air of Izmir, Turkey.

Air samples were collected in Izmir, Turkey at two (suburban and urban) sites during three sampling programs in 2002 and 2004 to determine the ambient concentrations of several monoaromatic, chlorinated and oxygenated volatile organic compounds (VOCs). Samples were analyzed for 60 VOCs using gas chromatography/mass spectrometry and 28 compounds were detected in most samples. On the average, urban air VOC concentrations were about four times higher than those measured at the suburban site. Toluene (40.6%) was the most abundant compound in suburban site and was followed by benzene (7.4%), o,m-xylene (6.5%), and 1,2-dichloroethane (5.1%). In urban site, toluene (30.5%), p-xylene (14.9%), o,m-xylene (11.4%), and ethyl benzene (7.2%) were the dominating compounds in summer. In winter, toluene (31.1%), benzene (23.9%), 1,2-dichloroethane (9.5%), and o,m-xylene (8.2%) were the most abundant compounds. Receptor modeling (positive matrix factorization) has been performed to estimate the contribution of specific source types to ambient concentrations. Six source factors (gasoline vehicle exhaust, diesel vehicle exhaust+residential heating, paint production/application, degreasing, dry cleaning, and an undefined source) were extracted from the samples collected in the urban site. Three source factors (gasoline vehicle exhaust, diesel vehicle exhaust, and paint production/application) were identified for the suburban site.

Air Pollutants↗

Evaluation of total volatile organic compound emissions from adhesives based on chamber tests.

In 1997, Homeswest in western Australia and Murdoch University developed a project to construct low-allergen houses (LAHs) in a newly developed suburb. Before the construction of LAHs, all potential volatile organic compound (VOC) emission materials used in LAHs are required to be measured to ensure that they are low total VOC (TVOC) emission materials. This program was developed based on this purpose. In recent times, the number of complaints about indoor air pollution caused by VOCs has increased. A number of surveys of indoor VOCs have indicated that many indoor materials contribute to indoor air pollution. Although some studies have been conducted on the characteristics of VOC emissions from adhesives, most of them were focused on VOC emissions from floor adhesives. Few measurements of VOC emissions from adhesives used for wood, fabrics, and leather are available. Furthermore, most research on VOC emissions from adhesives has been done in countries with cool climates, where ventilation rates in the indoor environment are lower than those in Mediterranean climates, due to energy conservation. VOCs emitted from adhesives have not been sufficiently researched to prepare an emission inventory to predict indoor air quality and to determine both exposure levels for the Australian population and the most appropriate strategies to reduce exposure. An environmental test chamber with controlled temperature, relative humidity, and airflow rate was used to evaluate emissions of TVOCs from three adhesives used frequently in Australia. The quantity of TVOC emissions was measured by a gas chromatography/flame ionization detector. The primary VOCs emitted from each adhesive were detected by gas chromatography/mass spectrometry. The temporal change of TVOC concentrations emitted from each adhesive was tested. A double-exponential equation was then developed to evaluate the characteristics of TVOC emissions from these three adhesives. With this double-exponential model, the physical processes of TVOC emissions can be explained, and a variety of emission parameters can be calculated. These emission parameters could be used to estimate real indoor TVOC concentrations in Mediterranean climates.

Adhesives↗

Comparison of different TiO2 photocatalysts for the gas phase oxidation of volatile organic compounds.

Gas-solid photocatalyzed oxidation of air contaminants is being explored more and more for possible application to decontamination, purification and deodorization of enclosed atmospheres. Indoor air is characterized by a huge number of pollutants at low concentrations. Volatile organic compounds (VOC) represent the main indoor air pollutants category, and are of great concern since some of them can act negatively on human health. Several treatments exist to reduce VOC concentrations in gaseous effluents, but photocatalytic oxidation appears to be the most appropriate regarding indoor air specific constraints. It is then necessary to develop photocatalysts, which can possibly be used in an application such as indoor air-quality improvement. In the present work, three different TiO2-based materials were studied and compared for the photocatalytic oxidation of a typical pollutant of indoor air: methyl ethyl ketone. Kinetic studies were performed for each material in dry and humid air conditions, and the Langmuir-Hinshelwood model was satisfactorily applied in almost every case. A second approach consisted of determining methyl ethyl ketone degradation by-products. Acetaldehyde was found to be the main gaseous intermediate, and could be taken into account in the general Langmuir-Hinshelwood modeling.

Air Pollutants↗

Determination of volatile organic compounds in river water by solid phase extraction and gas chromatography.

A simple, rapid, and reproducible method is described employing solid-phase extraction (SPE) using dichloromethane followed by gas chromatography (GC) with flame ionization detection (FID) for determination of volatile organic compound (VOC) from the Buriganga River water of Bangladesh. The method was applied to detect the benzene, toluene, ethylbenzene, xylene and cumene (BTEXC) in the sample collected from the surface or 15 cm depth of water. Two-hundred ml of n-hexane-pretreated and filtered water samples were applied directly to a C18 SPE column. BTEXC were extracted with dichloromethane and average concentrations were obtained as 0.104 to 0.372 microg/ml. The highest concentration of benzene was found as 0.372 microg/ml with a relative standard deviation (RSD) of 6.2%, and cumene was not detected. Factors influencing SPE e.g., adsorbent types, sample load volume, eluting solvent, headspace and temperatures, were investigated. A cartridge containing a C18 adsorbent and using dichloromethane gave better performance for extraction of BTEXC from water. Average recoveries exceeding 90% could be achieved for cumene at 4 degrees C with a 2.7% RSD.

Chemistry Techniques, Analytical↗

Diagnosis of bacteriuria by detection of volatile organic compounds in urine using an automated headspace analyzer with multiple conducting polymer sensors.

The Osmetech Microbial Analyzer (OMA) is an automated headspace analyzer fitted with a novel detector system consisting of an array of polymer sensors, each of which responds to different volatile organic compounds. The system can be used for screening clinical urine specimens for significant bacteriuria by sampling urine headspace and subjecting the output of the multiple-detector response to principal component analysis. The OMA readily distinguished artificially infected urine samples from sterile controls. The OMA was then used to analyze 534 unselected clinical urine specimens, of which 21.5% had significant bacteriuria (containing >10(5) CFU of bacteria/ml). The sensitivity and specificity of the OMA compared with conventional culture were 83.5 and 87.6%, respectively. The OMA is a promising automated system for the rapid routine screening of urine specimens, and further clinical trials are in progress.

Bacteria↗

Multiple microbial activities for volatile organic compounds reduction by biofiltration.

In the northeast of Italy, high volatile organic carbon (VOC) emissions originate from small-medium companies producing furniture. In these conditions it is difficult to propose a single, efficient, and economic system to reduce pollution. Among the various choices, the biofiltration method could be a good solution, because microbial populations possess multiple VOC degradation potentials used to oxidize these compounds to CO2. Starting from the air emissions of a typical industrial wood-painting plant, a series of experiments studied in vitro microbial degradation of each individual VOC. Isolated strains were then added to a laboratory-scale biofiltration apparatus filled with an organic matrix, and the different VOC behavior demonstrated the potential of single and/or synergic microbial removal actions. When a single substrate was fed, the removal efficiency of a Pseudomonas aeruginosa inoculated reactor was 1.1, 1.17, and 0.33 g m(-3) hr(-1), respectively, for xylene, toluene, and ethoxy propyl acetate. A VOC mixture composed of butyl acetate, ethyl acetate, diacetin alcohol, ethoxy propanol acetate, methyl ethyl ketone, methyl isobutyl ketone, toluene, and xylene was then fed into a 2-m(3) reactor treating 100 m3 hr(-1) of contaminated air. The reactor was filled with the same mixture of organic matrix, enriched with all of the isolated strains together. During reactor study, different VOC loading rates were used, and the behavior was evaluated continuously. After a short acclimation period, the removal efficiency was > 65% at VOC load of 150-200 g m(-3) hr(-1). Quantification of removal efficiencies and VOC speciation confirmed the relationship among removal efficiencies, compound biodegradability, and the dynamic transport of each mixture component within the organic matrix. Samples of the fixed bed were withdrawn at different intervals and the heterogeneous microbial community evaluated for both total and differential compound counts.

Air Pollutants↗

Identification of volatile organic compounds in blood by purge and trap PLOT-capillary gas chromatography coupled with Fourier transform infrared spectroscopy.

A purge and trap concentrator with a Tenax trap was coupled to gas chromatography-Fourier transform infrared spectrometry for the identification of volatile organic compounds in blood samples. A styrene-divinyl benzene porous layer capillary column allowed the separation of compounds such as household and medical gases, solvents and alcohol congeners. The identification limits in blood, measured by comparison to an in-house vapour phase spectrum library, generally ranged from 0.05 to 10 mg/l, depending on the analyte structure. Low molecular weight alcohols had identification limits up to 100 mg/l. Six actual casework examples were collected during a 1-year period of routine use to demonstrate the feasibility of the method.

Adolescent↗

Dual column capillary gas chromatographic system for the in situ analysis of volatile organic compounds on a cometary nucleus.

Two Wall Coated Open Tubular capillary columns, coated with poly(cyanopropylphenyl-dimethyl)siloxane and poly(diphenyl-dimethyl)siloxane stationary phases, have been selected for use in the COmetary SAmpling and Composition space experiment for the separation and identification of the wide range of volatile organic compounds which could be present in cometary nuclei. This article presents the main characteristics of the tandem column system for the analysis of solutes of cometary interest within the constraints of space instrumental operating conditions. The high efficiency of the columns is demonstrated and the influence of the operating conditions on their separation properties are investigated. The studied columns exhibit complementary retention pattern: their use in a dual column system makes it possible to achieve the separation and the identification of the compounds of interest. Finally, the good analytical behavior of the columns when analyzing samples which include large amounts of water, the main presumed volatile in comets, is demonstrated. The presented results thus show the suitability of the selected tandem columns system for the desired analyses, and their performance on adaptation to in-situ cometary chemical investigation.

Chromatography, Gas↗