Failure modes and effects analysis for clinical implementation of online adaptive radiotherapy: A systematic review.

BACKGROUND: The accuracy of radiotherapy is limited by anatomical variations occurring over time scales ranging from sub-seconds to days. Online Adaptive Radiotherapy (OART) addresses this by enabling daily plan adaptation based on real-time imaging. While OART offers improved dose conformity, its dynamic, time-constrained workflow introduces novel failure modes that challenge traditional quality assurance protocols. PURPOSE: This study aims to synthesize the existing literature on Failure Modes and Effects Analysis (FMEA) for OART to systematically catalog risks and identify mitigation strategies. METHODS: A systematic literature search was conducted to identify studies applying FMEA to OART workflows. Eleven studies were included, covering MR-guided (ViewRay MRIdian, Elekta Unity), CBCT-guided (Varian Ethos), and MR-enhanced C-arm linac systems. To address heterogeneity in risk scoring methodologies (e.g., TG-100 10-point scales vs. 5-point rankings), extracted failure modes were harmonized into a standardized three-tier risk classification system (Class I: Low, Class II: Intermediate, Class III: High). RESULTS: A total of 300 unique failure modes were identified, with 49.6 percent classified as high-risk (Class III). Analysis revealed that the majority of high-risk failures were concentrated in the online treatment delivery phase, specifically within human-computer interactions and anatomical contouring steps. CONCLUSIONS: This study supports the development of tailored, robust QA frameworks that prioritize human factors and process consistency to guide safe implementation in diverse clinical settings.

Humans↗

Automatic analysis of multiplex ligation-dependent probe amplification products (exemplified by a commercial kit for prenatal aneuploidy detection).

For use in routine prenatal diagnostics, we developed software and methods for automatic aneuploidy detection based on a commercial multiplex ligation-dependent probe amplification (MLPA) kit. Software and methods ensure a reliable, objective, and fast workflow, and may be applied to other types of MLPA kits. Following CE of MLPA amplification products, the software automatically identified the peak area for each probe, normalized it in relation to the neighboring peak areas of the test sample, computed the ratio relative to a reference created from normal samples, and compensated the ratio for a side effect of the normalization procedure that scaled all chromosomally normal DNA peak areas slightly up or down depending on the kind of aneuploidy present. For the chromosomes 13, 18, 21, X, and Y, probe reliability weighted mean ratio values and corresponding SDs were calculated, and the significance for being outside a reference interval around ratio 1.0 was tested. p < or = 1% suggested aneuploidy and 1 < p < or = 5% suggested potential aneuploidy. Individual peaks, where the normalized area was situated more than 4 SD from the corresponding reference, suggested possible partial deletion or gain. Sample quality was automatically assessed. Control probes were not required. Having used the software and methods for two years, we conclude that a reliable, objective, and fast workflow is obtained.

Aneuploidy↗

Multi-dimensional HPLC/MS of the nucleolar proteome using HPLC-chip/MS.

The proteome of the human nucleolus was investigated in a single analysis using off-line strong cation exchange chromatography and microfraction collection combined with HPLC-chip/MS. The analysis was conducted either as a 1-D workflow with HPLC-chip alone or as a 2-D workflow. Two hundred and six unique proteins were identified in the International Protein Index human database corresponding to 2024 unique tryptic peptides identified in the 2-D analysis. In contrast, only 34 proteins and 151 corresponding tryptic peptides were found by applying a 1-D separation strategy. This clearly indicated that the complexity of the samples required the combination of more than one orthogonal separation technique. Stringent database search criteria, including reversal of sequences and therefore better exclusion of false-positive identifications, were applied for reliable protein identification.

Cell Nucleolus↗

Molecular Diagnostics for WHO Priority Bacterial Pathogens: A Bibliometric Mapping of Diagnostic Platforms, Resistance Markers, and Antimicrobial Resistance Research Trends.

Antimicrobial resistance (AMR) constrains effective treatment and carries implications for infection control, surveillance, and public health. The World Health Organization (WHO) priority bacterial pathogen framework has intensified the need for diagnostic innovation by redefining research priorities around organisms combining high disease burden with complex resistance profiles. Molecular diagnostics have accordingly moved beyond culture-based workflows, integrating rapid pathogen identification, resistance-marker detection, genomic surveillance, and clinical decision support. The present study conducted a bibliometric mapping of the literature on WHO priority pathogens. Rather than addressing resistance at a general level or a single pathogen or technology, it integrates priority pathogens, molecular platforms, and resistance markers within a single framework, tracing their joint thematic and temporal evolution along an explicit pathogen-platform-marker axis. Scopus-indexed articles and reviews (2000-2025) were retrieved, yielding 1746 publications after screening adapted from the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Analyses used Bibliometrix/Biblioshiny, R, and VOSviewer. The literature expanded markedly after 2018, led by China and the United States. Methicillin-resistant Staphylococcus aureus (MRSA), Mycobacterium tuberculosis, Enterococcus faecium, and the Enterobacterales-carbapenemase axis constituted the principal thematic cores, whereas conventional polymerase chain reaction (PCR)/nucleic acid amplification testing (NAAT) and whole-genome sequencing were the dominant platforms. Overall, the field has evolved from pathogen detection into an AMR-centered translational domain encompassing resistance prediction, genomic epidemiology, surveillance, and clinical decision support. Diagnostic development, stewardship, and surveillance depend on hybrid workflows coupling rapid marker-targeted assays with genome-based characterization, delivering actionable resistance within clinically meaningful timeframes, and extending coverage to underrepresented pathogens and platforms.

Humans↗

Nonredundant mass spectrometry: a strategy to integrate mass spectrometry acquisition and analysis.

Protein identification using automated data-dependent tandem mass spectrometry (MS/MS) is now a standard procedure. However, in many cases data-dependent acquisition becomes redundant acquisition as many different peptides from the same protein are fragmented, whilst only a few are needed for unambiguous identification. To increase the quality of information but decrease the amount of information, a nonredundant MS (nrMS) strategy has been developed. With nrMS, data analysis is an integral part of the overall MS acquisition and analysis, and not an endpoint as typically performed. In this nrMS workflow a matrix assisted laser desorption/ionization-time of flight-time of flight (MALDI-TOF/TOF) instrument is used. MS and restricted MS/MS data are searched and identified proteins are used to generate an "exclusion list", after in silico digestion. Peptide fragmentation is then restricted to only the most intense ions not present in the exclusion list. This process is repeated until all peaks are accounted for or the sample is consumed. Compared to nanoLC-MS/MS, nrMS yielded similar results for the analysis of six pooled two-dimensional electrophoresis (2-DE) spots. In comparison to standard data-dependent MALDI-MS/MS for sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) gel band analysis, nrMS dramatically increased the number of identified proteins. It was also found that this new workflow significantly increased sequence coverage by identifying unexpected peptides, which can result from post-translational modifications.

Algorithms↗

Automating proteome analysis: improvements in throughput, quality and accuracy of protein identification by peptide mass fingerprinting.

The use of robots has major effects on maximizing the proteomic workflow required in an increasing number of high-throughput projects and on increasing the quality of the data. In peptide mass finger printing (PMF), automation of steps downstream of two-dimensional gel electrophoresis is essential. To achieve this goal, the workflow must be fluid. We have developed tools using macros written in Microsoft Excel and Word to complete the automation of our platform. Additionally, because sample preparation is crucial for identification of proteins by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry, we optimized a sandwich method usable by any robot for spotting digests on a MALDI target. This procedure enables further efficient automated washing steps directly on the MALDI target. The success rate of PMF identification was evaluated for the automated sandwich method, and for the dried-droplet method implemented on the robot as recommended by the manufacturer. Of the two methods, the sandwich method achieved the highest identification success rate and sequence coverage of proteins.

Colonic Neoplasms↗

High-throughput approaches for the discovery and optimization of new olefin polymerization catalysts.

The discovery of new olefin polymerization catalysts is currently a time-intensive trial-and-error process with no guarantee of success. A fully integrated high-throughput screening workflow for the discovery of new catalysts for polyolefin production has been implemented at Symyx Technologies. The workflow includes the design of the metal-ligand libraries using custom-made computer software, automated delivery of metal precursors and ligands into the reactors using a liquid-handling robot, and a rapid primary screen that serves to assess the potential of each metalligand-activator combination as an olefin polymerization catalyst. "Hits" from the primary screen are subjected to secondary screens using a 48-cell parallel polymerization reactor. Individual polymerization reactions are monitored in real time under conditions that provide meaningful information about the performance capabilities of each catalyst. Rapid polymer characterization techniques support the primary and secondary screens. We have discovered many new and interesting catalyst classes using this technology.

Journal Article↗

Internal regulations and general guidelines of a neurosurgical department and training programme.

It is strongly recommended that general guidelines and internal regulations be laid down in written form by the department. The guidelines regulate the general workflow and related trainee duties and responsibilities, education and research, special procedures for particular diseases and conditions (standards of care). Regarding general workflow of the department, the following items should be laid down once in written form: time table of department, working hours, admission procedures, medical records directives, responsibilities on wards and in the emergency unit, patient information, discharge procedures, outpatient consultations, call schedule and on-call duty plan, as well as week-end and holiday regulations for rounds on wards and ICU. Regarding education and research, the following items should be written down: conferences and teaching rounds, policies on presentations and publications, policies regarding meetings and courses, research leave and vacation plan. The written definition of standards of care is still considered optional in neurosurgery at the present time.

Certification↗

Radiologist's clinical information review workstation interfaced with digital dictation system.

Efficient access to information systems integrated into the radiologist's interpretation workflow will result in a more informed radiologist, with an enhanced capability to render an accurate interpretation. We describe our implementation of radStation, a radiologist's clinical information review workstation that combines a digital dictation station with a clinical information display. radStation uses client software distributed to the radiologist's workstation and central server software, both running Windows NT (Microsoft, Redmond, WA). The client system has integrated digital dictation software. The bar-code microphone (Boomerang, Dictaphone Corp, Stratford, CT) also serves as a computer input device forwarding the procedure's accession number to the server software. This initiates multiple queries to available legacy databases, including the radiology information system (RIS), laboratory information system, clinic notes, hospital discharge, and operative report system. The three-tier architecture then returns the clinical results to the radStation client for display. At the conclusion of the dictation, the digital voice file is transferred to the dictation server and the client notifies the RIS to update the examination status. The system is efficient in its information retrieval, with queries displayed in about 1 second. The radStation client requires less than 5 minutes of radiologist training in its operation, given that its control interface integrates with the well-learned dictation process. The telephone-based dictation system, which this new system replaced, remains available as a back-up system in the event of an unexpected digital dictation system failure. This system is well accepted and valued by the radiologists. The system interface is quickly mastered. The system does not interrupt dictation workflow with the display of all information initiated with examination bar-coding. This system's features could become an accepted model as a standard tool for radiologists.

Data Collection↗

Integration of radiologist peer review into clinical review workstation.

Professional peer review of random prior radiologist's interpretations is mandated by the Joint Commission on Accreditation of Healthcare Organizations (JCAHO). The JCAHO expects documentation of 5% rate of random peer-review cases. Countless hours are spent in departments fulfilling these requirements. The integration of the peer-review process into the radiologist's interpretation workflow was expected to increase the percentage of documented peer review, yet decrease the time and effort for this documentation. radStation clinical review workstations are deployed at every reading station. When a requisition is bar-coded, radStation retrieves the patient's clinical information and automatically displays the prior comparison report. If the radiologist agrees with the prior report, a single click on a "quality assurance' agree box documents the agreement. In the case of a discordance, an additional dialog box automatically appears and the radiologist enters the reason for disagreement and then submits the case as a discrepancy. The system holds the discordance for 3 to 5 working days, then notifies the original radiologist via E-mail that a prior interpretation has been submitted for peer review, lists the submitted discrepancy reason, and provides a link to display the discordant report. The peer-review database is separate from the existing radiology information system (RIS). At the end of every month, summary reports of all peer-review activity are generated automatically. Initial benchmarks of our deployed system anticipate documentation of long-term random peer-review rate at greater than 50% of interpreted cases. The system enhances the peer-review process by integrating it with the normal interpretation workflow. The time to complete peer review using radStation is less than 1 second per normal case and less than 60 seconds for a discordant case. The E-mail notification system is fully automated, eliminating the need for secretarial involvement in the data collection. This system has completely replaced a manual paper-based system. The integration of peer review directly into the radiologist's interpretation workstation greatly enhances the capability to easily exceed JCAHO standards. The overall increase in peer-review documentation should continue to improve the ability to document a consistent high quality of patient care.

Computer Communication Networks↗

Upgrading legacy systems for the Integrating the Healthcare Enterprise (IHE) initiative.

As technology vendors have adopted standardized communication protocols, including Digital Imaging and Communications in Medicine (DICOM) and Health Level 7 (HL7), interconnectivity between various devices has been simplified. The recent Integrating the Healthcare Enterprise (IHE) initiative will further promote the use of standards for interconnectivity. Until these standards are universally accepted, we must live in a transitional world where some components will communicate without any modification, while others require upgrades to allow them to meet the new standards. In designing and implementing the network at University of California Los Angeles (UCLA) Medical Center, some integration problems were found that are common to the industry. Creating departmental workflow with only a limited number of acquisition devices supporting the DICOM worklist was the initial problem addressed. Although many manufacturers provide this function for their new scanners, upgrading existing equipment is often cost-prohibitive. To ensure the quality of the demographic information in the image data and the workflow of the system, third-party worklist components were required to upgrade the legacy acquisition devices. These worklist components provided a standards-compliant facade on top of the legacy equipment, allowing seamless integration with the remainder of the network. To support the distribution of worklist information and the feedback of procedure status, a bidirectional HL7/DICOM protocol bridge was required. Although many radiology information system (RIS) manufacturers will be providing native DICOM capabilities in future product releases, the majority of current RIS installations have no DICOM functionality. Similar to the legacy scanners, the HL7/DICOM bridge provided a DICOM-compliant facade to the non-DICOM RIS. The additional use of web-based technology for worklist display further extended flexibility of this facade. We have demonstrated standards-compliant facade technology allowing legacy components to operate seamlessly in an IHE environment at a fraction of the cost of upgrading to new equipment.

Computer Communication Networks↗

Computers in imaging and health care: now and in the future.

Early picture archiving and communication systems (PACS) were characterized by the use of very expensive hardware devices, cumbersome display stations, duplication of database content, lack of interfaces to other clinical information systems, and immaturity in their understanding of the folder manager concepts and workflow reengineering. They were implemented historically at large academic medical centers by biomedical engineers and imaging informaticists. PACS were nonstandard, home-grown projects with mixed clinical acceptance. However, they clearly showed the great potential for PACS and filmless medical imaging. Filmless radiology is a reality today. The advent of efficient softcopy display of images provides a means for dealing with the ever-increasing number of studies and number of images per study. Computer power has increased, and archival storage cost has decreased to the extent that the economics of PACS is justifiable with respect to film. Network bandwidths have increased to allow large studies of many megabytes to arrive at display stations within seconds of examination completion. PACS vendors have recognized the need for efficient workflow and have built systems with intelligence in the management of patient data. Close integration with the hospital information system (HIS)-radiology information system (RIS) is critical for system functionality. Successful implementation of PACS requires integration or interoperation with hospital and radiology information systems. Besides the economic advantages, secure rapid access to all clinical information on patients, including imaging studies, anytime and anywhere, enhances the quality of patient care, although it is difficult to quantify. Medical image management systems are maturing, providing access outside of the radiology department to images and clinical information throughout the hospital or the enterprise via the Internet. Small and medium-sized community hospitals, private practices, and outpatient centers in rural areas will begin realizing the benefits of PACS already realized by the large tertiary care academic medical centers and research institutions. Hand-held devices and the Worldwide Web are going to change the way people communicate and do business. The impact on health care will be huge, including radiology. Computer-aided diagnosis, decision support tools, virtual imaging, and guidance systems will transform our practice as value-added applications utilizing the technologies pushed by PACS development efforts. Outcomes data and the electronic medical record (EMR) will drive our interactions with referring physicians and we expect the radiologist to become the informaticist, a new version of the medical management consultant.

Computers↗

Integration, acceptance testing, and clinical operation of the Medical Information, Communication and Archive System, phase II.

The Medical Information, Communication and Archive System (MICAS) is a multivendor incremental approach to picture archiving and communications system (PACS). It is a multimodality integrated image management system that is seamlessly integrated with the radiology information system (RIS). Phase II enhancements of MICAS include a permanent archive, automated workflow, study caches, Microsoft (Redmond, WA) Windows NT diagnostic workstations with all components adhering to Digital Information Communications in Medicine (DICOM) standards. MICAS is designed as an enterprise-wide PACS to provide images and reports throughout the Strong Health healthcare network. Phase II includes the addition of a Cemax-Icon (Fremont, CA) archive, PACS broker (Mitra, Waterloo, Canada), an interface (IDX PACSlink, Burlington, VT) to the RIS (IDXrad) plus the conversion of the UNIX-based redundant array of inexpensive disks (RAID) 5 temporary archives in phase I to NT-based RAID 0 DICOM modality-specific study caches (ImageLabs, Bedford, MA). The phase I acquisition engines and workflow management software was uninstalled and the Cemax archive manager (AM) assumed these functions. The existing ImageLabs UNIX-based viewing software was enhanced and converted to an NT-based DICOM viewer. Installation of phase II hardware and software and integration with existing components began in July 1998. Phase II of MICAS demonstrates that a multivendor open-system incremental approach to PACS is feasible, cost-effective, and has significant advantages over a single-vendor implementation.

Compact Disks↗

Meta-manager: a requirements analysis.

The digital imaging network-picture-archiving and communications system (DIN-PACS) will be implemented in ten sites within the Great Plains Regional Medical Command (GPRMC). This network of PACS and teleradiology technology over a shared T1 network has opened the door for round the clock radiology coverage of all sites. However, the concept of a virtual radiology environment poses new issues for military medicine. A new workflow management system must be developed. This workflow management system will allow us to efficiently resolve these issues including quality of care, availability, severe capitation, and quality of the workforce. The design process of this management system must employ existing technology, operate over various telecommunication networks and protocols, be independent of platform operating systems, be flexible and scaleable, and involve the end user at the outset in the design process for which it is developed. Using the unified modeling language (UML), the specifications for this new business management system were created in concert between the University of Arizona and the GPRMC. These specifications detail a management system operating through a common object request brokered architecture (CORBA) environment. In this presentation, we characterize the Meta-Manager management system including aspects of intelligence, interfacility routing, fail-safe operations, and expected improvements in patient care and efficiency.

Arizona↗

Creation of a software application for the clinical radiologist.

PURPOSE: To create a software application that automates a significant portion of a clinical radiologist's work. METHODS: The daily workflow of clinical radiologists in a university-based department was analyzed, specifically looking for manual tasks that could be implemented in software. An application that a practicing radiologist would use in his daily work was created. RESULTS: By using speech recognition, reports could be created, edited, and verified immediately. Online medical reference information could be made instantly accessible. Billing data could be captured accurately and completely at report creation time. A radiologist could be alerted to important upcoming events by use of a reminder system. Reports could be delivered immediately to referring physicians using either the internet or telephone. CONCLUSIONS: It is possible to improve the productivity of busy practicing clinical radiologists by automating a large portion of their workflow and implementing it in an easily mastered software application.

Humans↗

[Telematics and quality. Implementation of a telematic platform in Hamburg].

Since the end of the year 2000 a group of interested people has been working on the subject of quality improvement in breast cancer. Within this framework the project "improvement of breast cancer treatment by telemedicine" was started. Based on a workflow analysis and interviews with patients as well as health professionals, it turned out that there are gaps and flaws in the communication process. These problems occurred between health professionals involved in the treatment of patients and between health professionals and patients as well. As a result a telemedicine network has been developed which is based on MPLS technology. Within this network a central communication unit facilitates optimization of the workflow for the treatment of breast cancer. It will also be possible to set up groups for integrated care. Currently the system is being evaluated in specific breast centres in Hamburg. As the net is based on a positive business plan, it can be foreseen that a broad implementation will follow.

Breast Neoplasms↗

[Manipulator assisted endoscope guidance in functional endoscopic sinus surgery: proof of concept].

BACKGROUND: Functional endoscopic sinus surgery (FESS) is characterized by single-handed preparation and guidance of the endoscope by the nondominant hand. This results in an additional extension of operation time by up to 15% and ergonomic deficits. The aim of this study is the conception of an automated assistance system for FESS in view of the following questions: (1) Which degree of surgical automation is suitable for FESS? (2) Which design is suitable? (3) What are the properties of the technical system (planning, time, accuracy, precision) of the selected system? (4) Does the system offer potential for a clinical application? METHODS: In all 49 FESS were analyzed for surgical workflows. Measurement of the maximum forces within FESS was performed with 40 trials on an anatomical model. Three different mechanical systems were used in ten FESS and evaluated using the ICCAS Human-Machine Evaluation Scale. For realization of automated endoscope guidance an engine-driven and -braked manipulator (PA10-6c, Mitsubishi, Japan) was used. The technical parameters determined were expenditure of time for the preoperative planning of workspace, surgical accuracy and precision of the intraoperative endoscope positioning, maximal forces, and time. RESULTS: Concept-conditioned instrument changes amount to an average of 41.1 and 18.9% (5.21 min) time requirement for each FESS side. Maximum forces on the mucous membrane during a conventional FESS were measured at 9.8 N (5.9-9.8). Usability of the mechanical endoscope holder was estimated in 18 of 20 cases to be inferior to the standard procedure. The time needed for segmenting the intranasal workspace was 15.2 min (10.0-23.0). The maximum deviation of the automatically driven endoscope from a planned position amounted to 0.85 mm (manually 4.64 mm). The maximum force was measured with 1.1 N in the z direction (manually 9.8 N). Automated guidance of the endoscope to an intranasal position needed 7.25 s (6.4-7.9); manually 12.64 s (5.9-43.0). CONCLUSION: Guidance of the endoscope for FESS by an automated motor-driven system is possible. The conception which is based on workflow analysis favors a system with automatic definition of the workspace and a manual movement of the endoscope. The examined system offers a potential for clinical application. Definition of the automation level and development of a man-machine interface is more important than selection or reconstruction of a special manipulator for endoscope guidance in FESS from a surgical point of view.

Endoscopes↗

[OR-manager: surgeon or anaesthetist?].

The heart of any surgical department is the operating room (OR) area. Any disturbances in the daily routine will affect the work flow of the whole hospital. On account of its central function, with numerous connections to other departments, the OR is the crystallisation point for deficiencies in various events and processes. As an example, the major complaints made by a surgical department regarding workflow and communication are outlined. To solve these problems, an "OR organization" team was established, which worked on the basis of a newly developed OR statute. Within 1 year the employees were more contentment and the workflow had improved. However, even in the second year of central OR management there is still the need to further stabilize the system as mismanagement still occurs.

Anesthesiology↗