PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “surface modification”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 433 records · Page 24Linked to original sources

Surface modification of polystyrene nanoparticles using dextrans and dextran-POE copolymers: polymer adsorption and colloidal characterization.

Hydrophobically-modified dextran (dextran-phenoxy, DexP) and dextran-phenoxy-poly(oxyethylene) (DexP-POE) copolymers have been used to modify the surface properties and the stability of polystyrene nanoparticles. We examined the effect of phenoxy group and POE chain concentrations on their adsorption behaviour. The adsorbed amount was determined by the standard depletion method and the layer thickness of the adsorbed layer by photon correlation spectroscopy and electrokinetic measurements. The results show that the hydrophobic interaction is the driving force during the adsorption while the layer thickness correlates with the interfacial concentration of grafted POE chains. The effects of adsorbed layers on the properties of latex dispersions have been characterized in terms of the stability of the dispersions toward added electrolyte and temperature. The conformation of the adsorbed copolymers is discussed in relation to layer thickness and colloidal stability of suspensions.

Adsorption↗

Surface modification of poly (D,L-lactic acid) with chitosan and its effects on the culture of osteoblasts in vitro.

Chitosan is a good biodegradable natural polymer, widely used in biomedical fields. In this study, chitosan was used to modify the surface of poly (D,L-lactic acid) (PDLLA) in order to enhance its cell affinity. The properties of a modified PDLLA surface and control were investigated by contact angle and electron spectroscopy for chemical analysis (ESCA), which indicated the changes in surface energy and chemical structure. Scanning electron microscopy (SEM) observation displayed differences in surface morphology between the chitosan-modified film and the control. These data reflected that PDLLA films could be modified with chitosan and in turn may affect the biocompatibility of the modified films. Therefore, adhesion and growth of osteoblasts on modified PDLLA films as well as control were studied. Cell morphologies on the films were examined by SEM and cell viability was evaluated using an MTT assay; the differentiated cell function was assessed by measuring alkaline phosphatase (ALP) activity. The ALP activity of modified PDLLA films was significantly higher than that found on the control (p < 0.01). The proliferation of osteoblasts on modified films was also found to be higher than that on the control (p < 0.05), suggesting that chitosan could be used to modify PDLLA and then enhance its cell biocompatibility.

Alkaline Phosphatase↗

Surface modification of polycaprolactone with poly(methacrylic acid) and gelatin covalent immobilization for promoting its cytocompatibility.

Polycaprolactone (PCL) membrane was modified by grafting copolymerization of methacrylic acid (MAA) initiated under UV light. The covalent immobilization of gelatin on PCL-g-PMAA surface was consequently performed by using condensing agent, 1-ethyl-3-(3-dimethylamino propyl) carbodiimide hydrochloride. The occurrence of grafting copolymerization of PMAA and further immobilization of gelatin was confirmed by ATR-FTIR and X-ray photoelectron spectroscopy characterizations. The existence of carboxyl groups grafted on PCL surface was verified quantitatively by absorbance spectroscopy where rhodamine 6G was employed to react with carboxyl groups to generate an absorbance at 512 nm. The endothelial cell culture proved that the PCL membrane slightly modified with suitable amount of PMAA or gelatin had better cytocompatibility than control PCL or PCL membrane heavily modified with PMAA or gelatin.

Biocompatible Materials↗

Surface modification of an experimental silicone rubber maxillofacial material to improve wettability.

OBJECTIVES: Good wettability of maxillofacial prosthetic materials is important so that a lubricating layer is formed with supporting tissues thus reducing patient discomfort. The purpose of the study was to surface modify an experimental silicone rubber material in order to improve wettability. METHODS: Samples of experimental silicone rubber were surface modified by first argon plasma treatment followed by chemisorption of ethyleneoxy functional silanes. These were compared with the same silicone rubber which had ethyleneoxy functional surfactants incorporated into the polymer matrix. In all cases contact angles, tear strength and water uptake were measured. RESULTS: Surface modified materials had comparable contact angles to surfactant modified silicone rubber all being significantly lower than the unmodified material. Surface modified materials, however, had a significantly higher tear strength and lower water uptake in comparison to surfactant modified materials. CONCLUSIONS: Argon plasma treatment followed by chemisorption of ethyleneoxy functional silanes proved an effective way of improving the wettability of an experimental silicone rubber maxillofacial prosthetic material without altering bulk properties.

Materials Testing↗

A chemical surface modification of chitosan by glycoconjugates to enhance the cell-biomaterial interaction.

The use of wheat germ agglutinin (WGA), a lectin molecule, to modify chitosan and enhance the cell-biomaterial interaction was examined. The percentage of living fibroblast cells on the surfaces of tissue culture polystyrene (TCPS) control, WGA-modified chitosan, and unmodified chitosan films increased to 99%, 99%, and 85%, respectively, after seeding for 48 h. DNA staining revealed that a portion of fibroblasts cultivated on chitosan films( )were undergoing apoptosis. In contrast, fibroblasts growing on WGA-modified chitosan film surfaces did not show any indication of apoptosis. The number of fibroblast cells was the highest on the WGA-modified chitosan surfaces, followed by the TCPS and unmodified chitosan surfaces. This WGA-mediated enhancement on the fibroblast cell-biomaterial interaction was cell type dependent. Other types of cells may need different lectin molecules for enhanced interaction with biomaterials. Further, the evaluation of the heat shock protein (HSP) mRNA expression indicated that HSP 90 expression was increased in the fibroblast cells cultivated on chitosan films and decreased to basal levels on the WGA-modified chitosan films. Taken together, our data suggest that the use of WGA and other lectin molecules to enhance the cell-biomaterial interaction via oligosaccharide-mediated cell adhesion is a promising way to improve cell adhesion and proliferation, the two key issues in tissue engineering.

Base Sequence↗

Controllable surface modification of poly(lactic-co-glycolic acid) (PLGA) by hydrolysis or aminolysis I: physical, chemical, and theoretical aspects.

While biodegradable, biocompatible polyesters such as poly (lactic-co-glycolic acid) (PLGA) are popular materials for the manufacture of tissue engineering scaffolds, their surface properties are not particularly suitable for directed tissue growth. Although a number of approaches to chemically modify the PLGA surface have been reported, their applicability to soft tissue scaffolds, which combine large volumes, complex shapes, and extremely fine structures, is questionable. In this paper, we describe two wet-chemical methods, base hydrolysis and aminolysis, to introduce useful levels of carboxylic acid or primary and secondary amine groups, respectively, onto the surface of PLGA with minimal degradation. The effects of temperature, concentration, pH, and solvent type on the kinetics of these reactions are studied by following changes in the wettability of the PLGA using contact angle measurements. In addition, the treated surfaces are studied using X-ray photoelectron spectroscopy (XPS) to determine the effect on the surface chemical structure. Furthermore, we show using XPS analysis that these carboxyl and amine groups are readily activated to allow the covalent attachment of biological macromolecules.

Amines↗

Photochemical surface modification of poly(arylsulfone) ultrafiltration membrane and covalent immobilization of enzyme.

The sensitivity of poly(arylsulfone) (PSf) for UV irradiation in different solvents (water and ethanol) was investigated. It is confirmed that acrylic acid (AA) and acrylamide (AAm) are grafted only onto the surface of the membrane instead of the interior by FTIR and scanning electron microscope (SEM). The membrane performance (deltaJ/J0 and contact angle theta) after photografting was studied. In the range of conditions used, the grafting yield increases with irradiation time and monomer concentration growing. After photografting and N-3-dimethylaminopropyl-N'-ethycarbodiimide hydrochloride (EDC) activation, PSf membrane was immobilized with hydrogen peroxide oxidoreductase, and showed a higher activity than the control membrane.

Filtration↗

Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting.

Poly(dimethylsiloxane) (PDMS)-based microfluidic devices are increasing in popularity due to their ease of fabrication and low costs. Despite this, there is a tremendous need for strategies to rapidly and easily tailor the surface properties of these devices. We demonstrate a one-step procedure to covalently link polymers to the surface of PDMS microchannels by ultraviolet graft polymerization. Acrylic acid, acrylamide, dimethylacrylamide, 2-hydroxylethyl acrylate, and poly(ethylene glycol)monomethoxyl acrylate were grafted onto PDMS to yield hydrophilic surfaces. Water droplets possessed contact angles as low as 45 degrees on the grafted surfaces. Microchannels constructed from the grafted PDMS were readily filled with aqueous solutions in contrast to devices composed of native PDMS. The grafted surfaces also displayed a substantially reduced adsorption of two test peptides compared to that of oxidized PDMS. Microchannels with grafted surfaces exhibited electroosmotic mobilities intermediate to those displayed by native and oxidized PDMS. Unlike the electroosmotic mobility of oxidized PDMS, the electroosmotic mobility of the grafted surfaces remained stable upon exposure to air. The electrophoretic resolution of two test peptides in the grafted microchannels was considerably improved compared to that in microchannels composed of oxidized PDMS. By using the appropriate monomer, it should be possible to use UV grafting to impart a variety of surface properties to PDMS microfluidics devices.

Dimethylpolysiloxanes↗

Non-thrombogenicity by novel surface modification methods.

Three novel methods, recently developed by us, for the synthesis of non-thrombogenetic materials were reviewed. The first was the utilization of poly(vinyl sulfonate) as a heparinoid and a newly synthesized polymerizable-thrombin-inhibitor. The chemicals were grafted onto the surfaces of materials. The second was the use of thrombin-substrate-analog peptide. The immobilized peptide was decomposed by blood coagulation factors and inhibited thrombus formation on the surface. The third method was the enhancement of endothelialization by immobilization of bio-signal molecules. The immobilized biosignals remarkably accelerated the growth of endothelial cells.

Anticoagulants↗

Surface modification of implant materials and its effect on attachment and proliferation of bone cells.

Osteoblast-like cell response in variation with the air plasma sprayed (APS) TiO2 coating process parameters correlated with coating properties were investigated to evaluate the durability and biocompatibility of the surface-modified implant. The Taguchi technique was used to determine the coating properties affected by plasma spraying parameters on Ti-6AI-4V alloy substrate. The coating properties were characterized by porosity and surface roughness using an image analyzer and surf analyzer, respectively. The MG-63 osteoblast like cell morphology and proliferation data on TiO2 coated substrate were measured by SEM observation and direct cell counting. It was demonstrated that surface roughness increased as spray distance decreased but gas flow rates and spray distance were major factors in the case of porosity. The osteoblast adhesion morphology and proliferation data indicated that osteoblast-like cell morphology was not influenced by process parameters, but cell proliferation was affected to some extent by surface roughness and porosity among TiO2 coated specimens. Specifically, the difference between those of substrate and coating layer was relatively more visible.

Animals↗

Phage-related surface modifications of Pseudomonas aeruginosa: effects on the biological activity of viable cells.

Lysogenic [EI(8)3] and phage 8-resistant mutant (EI/8S17) strains of Pseudomonas aeruginosa EI were isolated. Besides lacking the capacity to adsorb phage 8, strains EI(8)3 and EI/8s17 did not contain surface substrate for the depolymerase that is produced de novo when phage 8 infects wild-type strain. EI. The glycolipoprotein (GLP) in the wild type contains phage 8 receptors and surface substrate for the depolymerase, as well as possesses characteristics of a virulence factor; therefore, the chemical and biological characteristics of the derived strains were investigated. The neutral-sugar, amino sugar, and protein content of the GLPs from the derived strains differed quantitatively from that of the wild type. In spite of some cross-reactivity, the GLPs from all strains were antigenically distinct in the indirect hemagglutination inhibition test. In mice, the toxicity of the GLP from strain EI(8)3 equaled that of the wild type, but the GLP of strain EI/8s17 was threefold less toxic. Significantly fewer viable EI(8)3 cells were required for the mouse 50% lethal dose than for the cells of either the wild type or the phage-resistant mutant.

Antigens, Bacterial↗

Human osteoprogenitor growth and differentiation on synthetic biodegradable structures after surface modification.

The ability to generate new bone for skeletal use is a major clinical need. Biomimetic scaffolds that interact and promote osteoblast differentiation and osteogenesis offer a promising approach to the generation of skeletal tissue to resolve this major health-care issue. In this study we examine the ability of surface-modified poly(lactic acid) (PLA) films and poly(lactic-co-/glycolic acid) (PLGA) (75:25) porous structures to promote human osteoprogenitor adhesion, spreading, growth, and differentiation. Cell spreading and adhesion were examined using Cell Tracker green fluorescence and confocal microscopy. Osteogenic differentiation was confirmed with alkaline phosphatase activity as well as immunocytochemistry for type I collagen, core binding factor-1 (Cbfa-1), and osteocalcin. Poor cell growth was observed on nonmodified PLA films and PLGA scaffolds. The polymers were then coupled with RGD peptides [using poly(L-lysine), or PLL] and physical adsorption as well as PLA films presenting adsorbed fibronectin (FN). Both modifications enhanced cell attachment and spreading. On PLA-FN and PLA-PLL-GRGDS films, the osteoblast response was dose dependent (20 pmol/L to 0.2 micromol/L FN and 30 nmol/L to 30 micromol/L PLL-GRGDS) and significant at concentrations as low as 2 nmol/L FN and 30 nmol/L PLL-GRGDS. With optimal concentrations of FN or RGD, adhesion and cell spreading were comparable to tissue culture plastic serum controls. In PLGA (75:25) biodegradable porous scaffolds, coated with FN, PLL-GRGDS, or fetal calf serum for 24 h in alpha MEM alone, prior to growth in dexamethasone and ascorbate-2-phosphate for 4-6 weeks, extensive osteoblast impregnation was observed by confocal and fluorescence microscopy. Cell viability in extended culture was maintained as analyzed by expression of Cell Tracker green and negligible ethidium homodimer-1 (a marker of cell necrosis) staining. Alkaline phosphatase activity, type I collagen, Cbfa-1, and osteocalcin expression were observed by immunocytochemistry. Mineralization of collagenous matrix took place after 4 weeks, which confirmed the expression of the mature osteogenic phenotype. These observations demonstrate successful adhesion and growth of human osteoprogenitors on protein- and peptide-coupled polymer films as well as migration, expansion, and differentiation on three-dimensional biodegradable PLGA scaffolds. The use of peptides/proteins and three-dimensional structures that provide positional and environmental information indicate the potential for biomimetic structures coupled with appropriate factors in the development of protocols for de novo bone formation.

Aged↗

Biodegradable PLGA microcarriers for injectable delivery of chondrocytes: effect of surface modification on cell attachment and function.

Poly(D,L-lactic-co-glycolic acid) (PLGA) microspheres were prepared by an oil/water emulsion solvent evaporation method to use as an injectable microcarrier for cell delivery. Three different kinds of PLGA microspheres having hydrophobic, negatively charged, and positively charged surfaces were prepared. Hydrophobic and negatively charged PLGA microspheres were prepared by using terminally capped and uncapped PLGA polymer, respectively. Positively charged PLGA microspheres were prepared by blending PLGA with PLGA-g-poly(L-lysine) graft copolymer as a surface modifying agent. Bovine chondrocytes were cultured on the three PLGA microspheres under serum conditions to comparatively evaluate cell attachment, cell proliferation, and cell function with respect to surface properties. Positively charged PLGA microspheres showed the highest cell attachment, growth, and function compared to hydrophobic and negatively charged microspheres. Surface-modified PLGA microspheres can potentially be used as an injectable delivery system for cells into a tissue defect site.

Absorbable Implants↗

Surface modification of poly-L-lactic acid (PLLA) membrane by grafting acrylamide: an effective way to improve cytocompatibility for chondrocytes.

Poly-L-lactic acid (PLLA) membranes were photo-oxidized in hydrogen peroxide solution under ultraviolet light (UV) to introduce hydroperoxide groups onto the PLLA membrane surfaces. The photo-oxidized membranes were then immersed in acrylamide (AAm) solution containing Fe2+ to graft polyacrylamide (PAAm) onto the PLLA membrane surfaces. The density of the hydroperoxide groups introduced on the PLLA membrane surfaces varied with the temperature and the photo-oxidization time. The occurrence of grafting was verified by X-ray photoelectron spectroscopy (XPS). The degree of grafting increased with the monomer concentration and the polymerization time. Water contact angle measurements showed that the wettability of the modified PLLA membranes had improved. Chondrocytes proliferated more rapidly and were more spread out on the modified membrane than on the control PLLA membrane, indicating that the PAAm-grafted PLLA membrane has better cytocompatibility for chondrocytes.

Acrylamide↗

TNF-alpha induces surface modifications in mouse Sertoli cells: physiopathological implications.

The expression of the adhesion molecules ICAM-1 and VCAM-1 has been measured in mouse Sertoli cells cultured in vitro. Cytometric analysis revealed that, in basal conditions, low levels of ICAM-1 and VCAM-1 were present on the surface of the cells, whereas treatment with TNF-alpha induced an increase in their expression. Binding experiments using both 51Cr-labelled lymphocytes, for quantitative analysis, and scanning electron microscopy demonstrated that increased expression of ICAM-1 and VCAM-1 on the surface of Sertoli cells, induced by TNF-alpha, determines an augmented adhesion between the two cell types. These results suggest the presence of a specific mechanism of interaction between Sertoli and immune-competent cells, possibly involved in the control of the immune response in the testis following an inflammatory reaction in situ. Such mechanism is of interest for the understanding of auto-immune pathologies of the testis and, if confirmed in humans, it could be involved in the sexual transmission of HIV infection.

Animals↗

In vitro behavior of a porous TiO2/perlite composite and its surface modification with fibronectin.

In this study, we introduce a porous composite material, termed "Ecopore", and describe in vitro investigation of the material and its modification with fibronectin. The material is a sintered compound of rutile TiO2 and the volcanic silicate perlite with a macrostructure of interconnecting pores. It is both inexpensive and easy to manufacture. We first investigated Ecopore for corrosion and leaching of elements in physiological saline. The corrosion supernatants did not contain critical concentrations of toxic trace elements. In an in vitro model, human primary osteoblasts (HOB) were cultured directly on Ecopore. HOB grew on the composite as well as on samples of its single constituents, TiO2 and perlite glass, and remained vital, but cellular spreading was less than on tissue culture plastic. The pro-inflammatory cytokines IL-1 and TNF-alpha were below detection limits in HOB culture supernatants, whereas IL-6 was detectable on a low level. To enhance cellular attachment and growth, the surface of the composite was modified by etching, functionalization with aminosilane and coupling of fibronectin. This modification greatly enhanced the spreading of HOB, indicated by vital staining and Sodium 3'-[1-(phenylaminocarbonyl)-3,4-tetrazolium]-bis (4-methoxy-6-nitro) benzene sulfonic acid hydrate (XTT) metabolism assays. HOB grew on the entire visible surface of porous fibronectin-modified composite, expressing alkaline phosphatase, a mature osteoblast marker. We conclude that Ecopore is non-toxic and sustains HOB growth, cellular spreading being improvable by coating with fibronectin. The composite may be usable in the field of bone substitution.

Alkaline Phosphatase↗

Enhanced transfection efficiency of PAMAM dendrimer by surface modification with L-arginine.

We designed a novel type of arginine-rich dendrimer, with a structure based on the well-defined dendrimer, polyamidoamine dendrimer (PAMAM). Further characterization was performed to prove that the polymer is a potent nonviral gene delivery carrier. The primary amines located on the surface of PAMAM were conjugated with L-arginine to generate an L-arginine-grafted-PAMAM dendrimer (PAMAM-Arg). For comparison, an L-lysine-grafted-PAMAM dendrimer (PAMAM-Lys) was also generated and compared as a control reagent. The polymers were found to self-assemble electrostatically with plasmid DNA, forming nanometer-scale complexes. From dynamic light scattering experiments, the mean diameter of the polyplexes was observed to be around 200 nm. We used PicoGreen reagent as an efficient probe for assaying complex formation of polymers with plasmid DNA. The complex composed of PAMAM-Arg/DNA showed increased gene delivery potency compared to native PAMAM dendrimer and PAMAM-Lys. The cytotoxicity and transfection efficiencies for 293, HepG2, and Neuro 2A cells were measured by comparison with PEI and PAMAM. In addition, transfection experiments were performed in primary rat vascular smooth muscle cells, and PAMAM-Arg showed much enhanced transfection efficiency. These findings suggest that the L-arginine-grafted-PAMAM dendrimer possesses the potential to be a novel gene delivery carrier for gene therapy.

Animals↗

Surface modification of neural probes with conducting polymer poly(hydroxymethylated-3,4- ethylenedioxythiophene) and its biocompatibility.

A novel conducting polymer, poly(hydroxymethylated-3,4-ethylenedioxythiophene) (PEDOT-MeOH), was electrochemically deposited onto the electrodes of micromachined neural probes. Uniformly distributed film was obtained from aqueous solution when doped with polystyrenesulfonate. The surface morphology was rough and had good cellular adhesion. Impedance spectroscopy showed that the magnitude of coated electrode was lower than that of the bare gold over a range of frequencies from 10(0)to 10(5) Hz. Since the biocompatibility of the interface between the neural probes and brain tissue plays an important role when the probes are implanted in the central nervous system for long-term application, biomolecules were incorporated into the coating. Nonapeptide CDPGYIGSR was codeposited as the counterion in the conducting films. The surface morphology of the coating was fuzzy, providing many bioactive sites for interaction with neural cells. The magnitude of impedance was as low as 53 kOmega at the biologically relevant frequency of 1 kHz. An in vitro experiment demonstrated that the neuroblastoma cells grew preferentially on the PEDOT-MeOH/CDPGYIGSR-coated electrode sites and spread beyond the electrode area.

Bridged Bicyclo Compounds, Heterocyclic↗