PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ASPIRATION”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Tracheobronchial aspiration of foreign bodies: current indications for emergency plain chest radiography.

PURPOSE: The purpose of this study was to determine the role of plain chest radiography in the evaluation of patients with suspected foreign-body aspiration. MATERIALS AND METHODS: During a 5-year period, 31 patients (18 men and 13 women; age range 6 months to 85 years) were referred to our observation for clinical suspicion of foreign-body aspiration. Clinically, the patients presented with cough in 27/31 cases (87.1%), decreased breath sounds in 22/31 (71%), choking in 18/31 (58.1%), fever in 7/31 (22.6%) and cyanosis in 5/31 (16.1%). Suspected foreign-body aspiration had occurred 2-72 h before hospitalisation. Within 2 h of hospitalisation, all patients underwent plain chest radiography performed in the upright position (two projections) in 10/31 (32.3%) patients and in the supine decubitus position in the remaining 21 (67.7%) patients. Plain chest radiography was subsequently integrated with multislice computed tomography (MSCT) of the chest in 3/31 (9.7%) patients and with bronchoscopy in 27/31 (87.1%) patients. RESULTS: Plain chest radiography showed the presence of a foreign body in the tracheobronchial tree in 7/31 (22.6%) patients, who subsequently underwent successful bronchoscopy in all cases. Foreign bodies included tooth fragment (three cases), nail (two cases), metallic spiral of a ball-point pen (one case) and an earring (one case). In the remaining 24/31 patients, plain chest radiography was positive in 14 cases, showing atelectasis (seven cases), pneumonia (six cases), pulmonary hyperinflation (one case) and pneumomediastinum (one case). Such findings had been caused by an aspirated foreign body, which was subsequently removed by means of bronchoscopy in all 14 patients. Moreover, three of the remaining ten patients with negative plain chest radiograph were submitted to MSCT of the chest, which required in 1 case tracheobronchial aspiration of a foreign body that was subsequently removed by means of bronchoscopy. Overall, plain chest radiography showed the presence of foreign-body aspiration and/or pleuroparenchymal lesions in 21/31 patients (67.7%); bronchoscopy was positive in 23/27 patients (85.2%), localising the foreign body in the right main bronchus in 16/27 patients (59.3%), left main bronchus in 7/27 patients (25.9%), intermediate bronchus in 2/27 patients (7.4%) and right lower lobe bronchus in 2/27 patients (7.4%). No late complications were observed within 6 months of hospital discharge. CONCLUSIONS: Plain chest radiography remains the initial imaging modality for patients with clinically suspected tracheobronchial aspiration of a foreign body. Nevertheless, in the case of negative chest radiography and a clinical suspicion of foreign-body aspiration, MSCT-possibly integrated with virtual bronchoscopy-should be considered in order to avoid unnecessary bronchoscopy.

Adolescent↗

Fine-needle aspiration biopsy of the mediastinum.

Fine-needle aspiration is a useful technique to identify neoplasms of many sites, such as breast, thyroid, and lung. Thirty-two mediastinum aspirates from 29 patients were reviewed. Five aspirates yielded insufficient material. Five aspirates were of benign lesions. Four aspirates were suggestive of but not diagnostic of malignancy. Eighteen aspirates contained malignant cells; in 13 of these, a definite cell type was identified, which usually was metastatic lung carcinoma; in five instances, the cell type could not be unequivocally identified. Complications were minimal, two instances of pneumothorax (6.3 percent) and two of hemoptysis (6.3 percent). No deaths or hemorrhage occurred. In 16 of the 29 patients (55 percent), thoracotomy was avoided because of fine-needle aspiration biopsy. It is concluded that fine-needle aspiration biopsy of the mediastinum is a safe, useful diagnostic tool. This procedure may obviate the need for thoracotomy in persons with inoperable cancer, thus lowering medical costs and length of hospital stay.

Adolescent↗

The cavitational ultrasonic surgical aspirator for cytoreduction in advanced ovarian cancer.

OBJECTIVE: The cavitational ultrasonic surgical aspirator is a newer surgical instrument that has been shown to be effective in tumor resection. The purpose of this study was to evaluate its usefulness for cytoreduction of advanced ovarian cancer. STUDY DESIGN: Over a 24-month period patients with advanced ovarian cancer (stage IIIC and IV or bulky recurrent disease) were studied to determine the frequency of use of the cavitational ultrasonic surgical aspirator and the sites of tumor resection. The blood loss and operative time for patients who underwent surgery with the cavitational ultrasonic surgical aspirator were compared by Student t test with those of patients who did not undergo surgery with the cavitational ultrasonic surgical aspirator. RESULTS: The cavitational ultrasonic surgical aspirator was utilized to effect optimal cytoreduction in 22 of 45 patients (48%). Of 52 sites of disease resected, 23 (44%) involved sites difficult to resect with standard operative techniques. These sites included the diaphragm, liver, spleen, and fixed retroperitoneal adenopathy. The cavitational ultrasonic surgical aspirator allowed resection from other sites, precluding procedures with potentially more morbidity. Of all 45 patients, 86% had cytoreduction to less than 2 cm and 44% to less than 0.5 cm. The blood loss and operative time were not different between cases in which the cavitational ultrasonic surgical aspirator was used and those in which it was not used. CONCLUSION: The cavitational ultrasonic surgical aspirator appears to contribute to cytoreduction in patients with advanced ovarian cancer.

Diaphragm↗

The use of fine-needle aspiration in the evaluation of persistent palpable dominant breast masses.

OBJECTIVE: Our purpose was to determine if fine-needle aspiration can decrease the necessity for open surgical biopsy in the diagnosis of a persistent palpable dominant breast mass. STUDY DESIGN: In a university obstetrics-gynecology resident physician training program, persistent palpable dominant breast masses seen in the Breast Diagnostic Center at Women's Hospital, Los Angeles County-University of Southern California Medical Center, were evaluated by fine-needle aspiration. When a cytologic diagnosis was obtained, the patients were treated, followed, or referred for treatment. Open surgical biopsy was reserved for those lesions that were not cytologically diagnosed or for which there was no concordance of the diagnostic triad of palpation, fine-needle aspiration, and mammography. RESULTS: Resident physicians rotating through the Breast Diagnostic Center performed 568 fine-needle aspirations under staff supervision. The technique was readily learned by most of the resident physicians with equipment already available in most outpatient settings. Fine-needle aspiration was performed on the initial clinic visit, and the preliminary cytologic diagnosis was given to the patient on the same day. Forty-two cancers were cytologically diagnosed (7% of the fine-needle aspirations). Seventy-five (13%) other patients were referred for open surgical biopsy as the definitive diagnostic procedure. Twenty-four (4%) patients elected open surgical excision biopsy of fine-needle aspiration-diagnosed masses. CONCLUSION: Fine-needle aspiration of persistent palpable dominant breast masses allows expeditious and potentially cost-effective management of most cases and decreases the necessity of open surgical biopsy for definitive diagnosis.

Adenofibroma↗

Cytologic diagnosis of prostatic carcinoma by fine-needle aspiration biopsy. Community hospital experience.

Transrectal fine-needle aspiration and transrectal or perineal core biopsies were simultaneously performed on 31 patients with suspected prostatic cancer over an eighteen-month period. Of the 29 aspirations that were adequate for cytologic diagnosis, there was histologic correlation in 24 (83%). The sensitivity of aspiration for the diagnosis for prostatic cancer was 92 per cent (11 of 12) compared with 85 per cent (11 of 13) for the core biopsy method. There were no apparent false negative or false positive diagnoses with the aspiration biopsy technique. Insufficient material was obtained by aspiration in 2 cases. A febrile urinary tract infection occurred in 1 patient after transrectal aspiration and core biopsy. Our results suggest that fine-needle aspiration may be utilized by the practicing urologist in conjunction with a pathologist trained in the interpretation of fine-needle aspirates as a safe, relatively inexpensive, and sensitive diagnostic procedure for suspected prostatic cancer.

Biopsy, Needle↗

Bone marrow biopsy instead of 'marrow juice' for cell kinetic analysis. Comparison of bone marrow biopsy and aspiration material.

Since cell kinetic bone marrow studies have so far exclusively been carried out on aspiration material and have yielded inconsistent or even contradictory results, we investigated the adequacy and reliability of aspirates for cell kinetic analyses in comparison to biopsies. Paired samples of bone marrow (133) were taken simultaneously by aspiration and Jamshidi biopsy from 48 patients with acute leukemias and 67 patients with non-leukemic disorders. Cell kinetic analysis by (1) flow cytometry (FCM) of cellular DNA and RNA content, (2) autoradiography for [3H]TdR pulse labelling indices and (3) liquid scintillation counting of [3H]TdR uptake revealed significantly higher values in biopsies (p less than 0.001) exceeding the corresponding results from aspirates on average by factors of 1.65 for FCM S-phase index, 1.90 for G0/1 cells with high RNA content, 1.82 for [3H]TdR LI and 1.90 for [3H]TdR uptake. In more than 70% of all samples results from biopsies were 1.1-11.4 times higher, indicating that aspirates were equivalent to biopsies in fewer tan 30% of cases. Cell kinetic analysis in vitro blood/biopsy mixtures and measurements of DNA synthesis rate in corresponding aspirates and biopsies revealed that these discrepancies are due to the contamination of aspirates with non-proliferating nucleated blood cells. Biopsy, however, was found to provide representative and reproducible sampling of marrow for cell kinetic studies and should replace the presently used aspirate already characterized as "unreliable marrow juice" by Dameshek et al. in 1937 [18].

Acute Disease↗

Fine needle aspiration in infected hip replacements.

Ninety painful prosthetic hips from 88 consecutive patients underwent fine needle aspiration and the results compared with clinical progress, operative findings and culture. Fourteen of the 15 cases proven to be infected at operation were correctly identified by fine-needle aspiration. The one hip with a false negative aspirate had an arthrogram which showed a cavity suggesting infection. There were three false positive aspirates. One grew a different organism at surgery from the original aspirate. The other two had no growth on surgical culture. Both had had pre-operative antibiotics. Eleven cultures of doubtful significance were repeated or regarded as negative and the patients carefully followed-up. One repeat culture confirmed infection emphasizing the importance of repeating doubtful aspirates. The sensitivity of aspiration is 93%, specificity is 96%. The accuracy is 95% confirming that aspiration is a simple and reliable method of diagnosing infection in hip prostheses.

Adolescent↗

Changes in follicular fluid gas and pH during carbon dioxide pneumoperitoneum for laparoscopic aspiration and their effect on human oocyte fertilizability.

OBJECTIVE: To determine changes in follicular fluid (FF) gases and acidity (pH) during either ultrasound (US)-guided or laparoscopic aspiration under carbon dioxide (CO2) pneumoperitoneum and relate the findings to the outcome of oocyte fertilization in vitro. DESIGN: A prospective study carried out over a limited period of 1 month during which test FF samples were obtained without direct exposure to CO2 or air. SETTING: Within the assisted pregnancy program setting at the Human Reproductive Biology Unit at the Soliman Fakeeh Hospital. PATIENTS: Infertile women undergoing either laparoscopic or US guided follicular aspiration for the purpose of in vitro fertilization treatment. INTERVENTION: Laparoscopic follicular aspiration under 100% CO2 pneumoperitoneum or transurethral US-guided follicular aspiration. RESULTS: Mean FF carbon dioxide partial pressure (pCO2) and oxygen partial pressure (pO2) were significantly higher in those aspirated at laparoscopy compared with those obtained by US-directed aspiration. The mean FF pH in the laparoscopic group was as a consequence significantly lower than in the US group. Oocyte fertilizability was significantly reduced in the laparoscopic aspiration group compared with the US group. This was more pronounced when the fertilization rate of the last recovered oocytes from the groups were compared. No difference was observed in the post fertilization embryonic development between the two groups. CONCLUSION: One hundred percent pneumoperitoneum leads to changes in FF that adversely affect oocyte fertilizability in a time-dependent manner. The use of US-directed procedure is advocated for all patients undergoing follicular aspiration in assisted pregnancy program. Where this is not feasible, the duration of CO2 pneumoperitoneum should be minimized.

Bicarbonates↗

Prediction of metastatic potential of aspirated cells from the Dunning R-3327 prostatic adenocarcinoma model.

Pathological grading systems have failed to assess accurately the prognosis of patients with prostatic carcinoma. A visual grading system of cancer cell motility has described successfully the metastatic potential of sublines of the Dunning R-3327 rat prostatic adenocarcinoma model maintained in vitro and in vivo. Clinical application of this technique would be facilitated if it could be performed upon aspirated cells. We compared the motility of cells obtained by biopsy and fine needle aspiration from in vivo Dunning tumors and determined if the motility of aspirated cells could predict metastatic potential. Specimens from the same tumor were obtained by fine needle aspiration and incisional biopsy from three sublines of low (less than 10%) and three sublines of high (greater than 90%) metastatic potential. Membrane ruffling, pseudopodal extension and cellular translation of 100 cells were graded using time-lapse videomicroscopy. Cells obtained by biopsy and aspiration had similar average (analysis of variance, p greater than 0.7) and variation (coefficient of variation, aspirated = 18.6%, biopsy = 17.7%) of motility. Aspirated cells from three low metastatic sublines (membrane ruffling 5.20 +/- SEM 0.41, pseudopodal extension 4.10 +/- 0.57 and cellular translation 3.07 +/- 0.45) were distinguished from cells of three high metastatic sublines (membrane ruffling 7.10 +/- 0.15, pseudopodal extension 6.93 +/- 0.22 and cellular translation 5.47 +/- 0.25). Cellular translation, the best discriminator, correctly classified the metastatic potential of the subline of origin in 82% of 60 individual cells. A grading system based upon the motility of aspirated cancer cells should be studied in human prostatic carcinoma.

Adenocarcinoma↗

Transabdominal fine needle aspiration of retroperitoneal lymph nodes in staging of genitourinary tract cancer (correlation with lymphography and lymph node dissection findings).

Percutaneous fine needle aspiration of retroperitoneal pelvic and abdominal lymph nodes was done in 100 patients with clinically localized bladder, prostatic, testis and penile cancer. A diagnosis of metastases to regional lymph nodes was detected by this method in 20 patients. Fine needle aspiration revealed evidence of regional lymph node involvement in 6 of 40 patients (15 per cent) with negative findings on lymphography and computerized tomography scan. Lymph node aspiration was followed by lymph node dissection in 50 patients. The correlation between aspiration and dissection was 68 per cent. The accuracy of obtaining representative material from the lymph node aspiration was 83 per cent. Negative results of lymph node aspiration cannot be used in clinical management. However, positive aspiration results provide the clinician with valuable information obtainable otherwise only by laparotomy or lymph node dissection. Positive aspiration results may spare patients with prostatic and bladder cancer an unnecessary radical operation, and may indicate early chemotherapy or surgery in patients with testis and penile cancer.

Biopsy, Needle↗

Pure preovulatory follicular fluid promotes in vitro maturation of in vivo aspirated equine oocytes.

In the mare, rates of fertilization and development are low in oocytes matured in vitro, and a closer imitation of in vivo conditions during oocyte maturation might be beneficial. The aims of the present study were, therefore, to investigate whether (1) equine oocytes can be matured in vitro in pure equine preovulatory follicular fluid, (2) priming of the follicular fluid donor with crude equine gonadotrophins (CEG) before aspiration of preovulatory follicular fluid promotes the in vitro maturation rate, (3) the in vitro maturation rate differs between oocytes aspirated during estrus and those aspirated again 8 days after the initial follicular aspiration, and (4) high follicular concentrations of meiosis activating sterols (MAS) are beneficial for in vitro maturation of equine oocytes. During estrus, 19 pony mares were treated with 25 mg CEG. After 24 h (Al) and again after 8 days (A2), all follicles >4mm were aspirated and incubated individually for 30 h in the following culture media: standard culture medium (SM), preovulatory follicular fluid collected before CEG containing low MAS concentrations (FF1), preovulatory follicular fluid collected before CEG containing high MAS concentrations (FF2) or preovulatory follicular fluid collected 35 h after administration of CEG containing low MAS concentrations (FF3). Cumulus expansion rate was significantly affected by culture medium. The overall nuclear maturation rate was significantly higher for oocytes collected at A1 (67%) than for oocytes collected at A2 (30%). For oocytes collected at A1, the maturation rates were 71% (FF1), 61% (FF2), 79% (FF3) and 56% (SM). An electrophoretic protein analysis of the culture media revealed the presence of a 200-kDa protein in FF3. The results demonstrate that (1) equine oocytes can be matured during culture in pure equine preovulatory follicular fluid, (2) preovulatory follicular fluid collected after gonadotrophin-priming seems superior in supporting in vitro maturation than standard culture medium, (3) oocytes aspirated 8 days after a previous aspiration are less competent for in vitro maturation than oocytes recovered during the initial aspiration, and (4) the regulation of meiotic resumption during in vitro culture of equine oocytes might be related to the presence of a 200-kDa protein.

Animals↗

Effects of needle tip bevel and aspiration procedure on the morphology and developmental capacity of bovine compact cumulus oocyte complexes.

Effects of the needle tip bevel and the aspiration procedure on the morphology of cumulusoocyte-complexes (COCs) and the developmental capacity of the oocytes after IVF were studied in 2 in vitro oocyte pick-up (OPU) simulations using a disposable ovum pick-up needle guidance system. In Experiment 1, the influence of the length of the needle bevel was investigated using a short and a long bevelled 20-g disposable needle. After being aspirated from slaughterhouse ovaries, the retrieved COCs were divided into 3 categories: 1) oocytes surrounded by a compact cumulus, 2) oocytes with an expanded cumulus, 3) partially naked oocytes. In Experiment 2, the influence of 5 different levels of aspiration vacuum for 3 different needle diameters (18-g, 19-g, 20-g) and 2 different needle bevels (long, short) was tested on the recovery and on the morphology of the cumulus investment of a fixed number of previously scored compact cumulus oocytes complexes (CCOCs), retrieved after slicing slaughterhouse ovaries. The re-retrieved COCs were allocated to Categories 1 and 3. The results show that the length of the needle bevel has a significant effect on oocyte recovery, in favor of the long-bevelled needle. As soon as higher aspiration vacua are used, a decrease of the number of CCOCs can be observed, which is less prominent for the short-bevelled needle compared to the long-bevelled one. The final number of blastocysts is similar for both needle types. In Experiment 2, the disposable needle system proved to be highly effective since nearly 80% of the CCOCs were retrieved. At low aspiration vacuum, up to 90% of the CCOCs withstand the aspiration procedure undamaged. Increasing the aspiration vacuum results in a decrease of the number of CCOCs, which is less pronounced using thinner needles. Averaged over all needle types, the prevalence of blastocysts expressed relative to the number of recovered oocytes decreases with higher aspiration vacuum.

Journal Article↗

Evaluation and comparison of 2 needle models in terms of blood aspiration during truncal block of the inferior alveolar nerve.

PURPOSE: We conducted a study to determine the possible differences in blood aspiration between 2 needles of the same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The working hypothesis was that increased blood aspiration may be expected with larger internal gauge needles. MATERIALS AND METHODS: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle were used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm and an XL Monoprotect (manufactured by Sofic, Mazamet, France, and distributed by Laboratorios Inibsa, Barcelona, Spain) 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the operator performing the technique, and blood aspiration (either positive or negative). RESULTS: No significant differences (P <.05) were observed on contrasting the blood aspiration positivity with the internal gauge of the needles. Likewise, no significant differences were seen on correlating aspiration to the anesthetic technique used, the number of bone contacts, the operator, or the patient-extraction side. Blood aspiration was observed in 8.7% of cases. CONCLUSIONS: No significant differences were recorded in terms of blood aspiration and internal gauge, operator, patient-extraction side, or the anesthetic technique involved. Consequently, our initial working hypothesis can be rejected, because no increased percentage of blood aspirations was observed for greater internal gauges.

Adult↗

Aspiration in chest compression alone without mechanical ventilation in the head down position in dogs.

BACKGROUND: Previous work by the authors has shown that chest compressions alone without mechanical ventilation during cardiopulmonary resuscitation in the natural supine position was associated with pulmonary aspiration in dogs. The purpose of this investigation was to test the hypothesis that a head down position may prevent aspiration during chest compressions alone and whether oxygenation can be improved by simply insufflation of oral oxygen 10 min after cardiac arrest. METHODS: Cardiac arrest was induced in ten mongrel dogs which were anesthetized and paralysed. Eight underwent chest compressions alone in different head down positions using an automatic compressor at 9 kg compression force and 3 cm compression depth. The study was composed of two parts. Part 1 evaluated the effect of insufflation of 10 l/min O2, into the mouth of the dogs, 10 min after initiation of resuscitation, using chest compressions alone. Part 2 was designed to test our hypothesis that the head down position may protect the lungs from aspiration during chest compression alone. The mouths of the dogs were filled with mixed barium and the dogs underwent serial episodes of chest compressions, for 10 min each, in the 20 degree head down, 10 degree head down and the natural supine positions. Chest X-rays with antero-posterior and lateral views were taken to evaluate pulmonary aspiration. Two additional dogs underwent direct chest compression alone in the natural supine position and the time of chest compression was shortened to 5 min. RESULTS: All dogs in the natural position showed evidence of pulmonary aspiration of barium, five or six of the dogs showed tracheal aspiration in the 10 degree head down position, while no any barium was visualized in the tracheo-broncheal trees of the dogs in the 20 degree head down position. Supplemental oxygen in the mouth improved the mean PaO2 from 67 +/- 26 to 160 +/- 97 mmHg during chest compressions alone. CONCLUSION: Chest compression alone without mechanical ventilation in the supine position caused pulmonary aspiration in the unprotected airway in dogs. This complication could be prevented by adopting a 20 degree head down position. The 10 degree head down position seemed to reduce the severity of the pulmonary aspiration, but not enough to eliminate the danger altogether. Supplemental oxygen in the mouth can improve oxygenation in chest compressions alone.

Administration, Oral↗

[Intracranial pressure response during secretion aspiration after administration of a muscle relaxant].

UNLABELLED: Aspiration of secretions is a usual nursing technique in patients undergoing mechanical ventilation that may be the cause of increased Intracranial Pressure (ICP). OBJECTIVE: This study aims to evaluate the repercussion of a muscle relaxant on ICP with secretion aspiration. METHOD: Clinical trial using the same patient as case and control, performing two endotracheal aspirations in each patients, on of them after administration of a muscle relaxant (Cis-Atracurium) and another no. The bolus administration of the relaxant in the first or second aspiration was done randomly. Thirteen patients with intraparenchymatous ICP measurement catheter were studied within the first 36 hours post-placement and with sedoanalgesia for a score of 6 on the Ramsay scale. ICP and CPP were measured before, during and after each aspiration. STATISTICAL METHOD: SPSS 11.0 program was used. Data analysis by Student's t test for paired data. Statistical significance level accepted was 95%. RESULTS: On comparing the cases in which muscle relaxant was administered with those in which it was not administered, statistically significant differences were found in the ICP and CCP values during secretion aspiration. CONCLUSIONS: According to the data obtained in the study, a lower increase of ICP was observed during secretion aspiration in those cases in which muscle relaxant was administered prior to the aspiration.

Adolescent↗

Contribution of routine joint aspiration to the diagnosis of infection before hip revision surgery.

OBJECTIVES: To define the sensitivity and specificity of routine preoperative hip aspiration for diagnosing hip prosthesis infection (HPI) and to separately analyze subgroups with and without a clinical suspicion of HPI before aspiration. METHODS: From June 1994 to June 1997, all patients scheduled for hip revision surgery underwent aspiration of the hip under image intensifier guidance. Microbiological results were compared between these preoperative specimens and the intraoperative specimens. The reason for surgery was either a clinical suspicion of HPI or pain suggesting loosening. RESULTS: The study patients had had multiple surgical procedures. HPI was suspected clinically in 39.4% of cases. Of the 109 patients who underwent aspiration, 54 had true-negative results, nine had false-negative results, and 44 had true-positive results (there were no false-positive results), yielding a sensitivity of 83% and a specificity of 100%. Diagnostic efficiency was 91.6%, positive predictive value was 100%, and negative predictive value was 85.7%. In the subset of 43 patients with a clinical suspicion of HPI, aspiration identified all the causative organisms in 60.5% of cases. Of the 66 patients with no clinical suspicion of HPI, 12 had HPI, and aspiration provided the diagnosis preoperatively in seven of these patients, radically changing their management plans. Restricting routine aspiration to patients whose prosthesis had been implanted within the last 5 years or whose erythrocyte sedimentation rate (ESR) was above 30 mm/h would not have modified our findings. CONCLUSIONS: Hip aspiration before revision surgery for pain is effective in detecting HPI, which can simulate aseptic loosening. However, this investigation may be noncontributive in patients who have had their prosthesis for more than 5 years and whose ESR is less than 30 mm/h.

Aged↗

Quantitative PCR detection of t(14;18) bcl-2/JH fusion sequences in follicular lymphoma patients: comparison of peripheral blood and bone marrow aspirate samples.

In patients with follicular lymphoma (FL), it is unresolved whether peripheral blood (PB) can replace bone marrow (BM) aspirate samples for detection of bcl-2/JH fusion sequences that result from the t(14;18)(q32;q21). We compare here the results of quantitative polymerase chain reaction (q-PCR) analysis for bcl-2/JH involving the major breakpoint cluster region (mbr) on paired PB and BM aspirate samples from 60 consecutive FL patients. There was a significant correlation between the level of bcl-2/JH fusion sequence obtained from PB and BM aspirate samples (r = 0.886), with 82% of samples showing less than one log of difference. Patients who had histological evidence of FL involving concurrent BM biopsy specimens had moderate to high levels of bcl-2/JH in both PB and BM aspirate samples, allowing unequivocal determination of translocation status (median bcl-2/JH to cyclophilin level was 8.014%). In contrast, patients with no detectable FL in their BM biopsy specimens often showed low levels of bcl-2/JH in both PB and BM aspirate samples (bcl-2/JH to cyclophilin median level = 0.006%), in a range similar to background levels that could be detected in patients without FL (n = 15, median bcl-2 mbr/JH to cyclophilin level = 0.002%). We conclude that PB can be used in place of BM aspirate samples to test for the presence of bcl-2 mbr/JH fusion sequence in FL patients and that either PB or BM aspirate testing yields a rough approximation of the degree of BM involvement by FL. However, in patients with minimal levels of bcl-2/JH in PB or BM aspirate samples, confirmation of this result by testing the primary tumor is recommended to confirm the presence of an identical bcl-2/JH fusion sequence and exclude false-positive results.

Biopsy↗

Mercury vapour release from a dental aspirator.

OBJECTIVE: To investigate the release of mercury vapour from a dental aspirator which vented its waste air through its base directly into the surgery environment. METHODOLOGY: Mercury vapour in air concentrations were measured at the breathing zone of the dentist during continuous operation of the aspirator. Further series of mercury vapour measurements taken at the aspirator exhaust vent were carried out to determine the sources of mercury vapour from this particular device. RESULTS: At the dentist's breathing zone, mercury vapour concentrations of ten times the current occupational exposure limit of 25 micrograms/m3 were recorded after 20 minutes of continuous aspirator operation. A build up of amalgam contamination within the internal corrugated tubing of the aspirator was found to be the main source of mercury vapour emissions followed by particulate amalgam trapped within the vacuum motor. As the vacuum motor heated up with run time, mercury vapour emissions increased. It was found that the bacterial air exhaust filter (designed to clean the contaminated waste air entering the surgery) offered no protection to mercury vapour. In this case the filter trapped particulate amalgam which contributed to further mercury vapour contamination as high volume air was vented through it. CONCLUSION: It is not known how many dental aspirators are in use that vent their waste air directly into the surgery or if this aspirator is representative of others in existence. The safety of dental aspirating systems with regard to mercury vapour exposure requires further investigation.

Air Pollution, Indoor↗