PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Digital subtraction angiography for leg venography.

Venography was performed in 25 legs of 17 patients using digital subtraction angiography (DSA). Reliable diagnoses of deep vein thrombosis or patency were made in the majority of these cases. There were no complications. Multiple injections of contrast material were required to image the entire leg; however, the total quantity of iodine necessary for each leg averaged 9 g, significantly less than with conventional techniques. The preferred method consisted of injecting 15 ml of 100 mg iodine/ml contrast material followed by 15 ml of heparinized saline. DSA proved a safe and useful means of evaluating veins of the leg.

Aged↗

Spiral computed tomographic angiography of the renal arteries: a prospective comparison with intravenous and intraarterial digital subtraction angiography.

PURPOSE: To assess the accuracy of computed tomographic angiography (CTA) in the evaluation of the renal arteries in comparison with intravenous (IVDSA) and intraarterial digital subtraction angiography (IADSA). METHODS: In 18 patients, 35 CTAs and DSAs (27 IADSA, 8 IVDSA) of the renal arteries were performed. CTA was done with 2-3 mm collimation,2-4 mm/sec table speed, after intravenous injection of 80 ml of contrast medium at 4 ml/sec with a scanning delay time of 14-21 sec. No previous circulation time curve was performed. CTA data were reconstructed with maximum intensity projection (MIP) and shaded surface display (SSD). The presence of stenosis was assessed on a three-point rating scale (grade 1-3). The quality of the examinations; visualization of the ostium, the main artery, and its branches; vessel sharpness, linearity, and intraluminal contrast filling were evaluated. We compared CTA with DSA. RESULTS: CTA had 96% sensitivity, 77% specificity, and 89% accuracy in the detection of stenoses > 50%. Due to technical errors two stenoses were erroneously diagnosed as positive but there were no false negative diagnoses. The quality of CTA was good in 56% and moderate in 34% of cases. Visualization of the ostium and main artery was graded as 1.74 (out of 2) points and of the renal branches as 1.02 (out of 2) points and of the renal branches as 1.02 (out of 2) points. The quality of CTA images was worse than that of IADSA in 52%, equal in 41%, and better in 7% of cases. CTA was equal to IVDSA in 25% and better in 75% of the cases. CONCLUSION: CTA is an accurate noninvasive method for the evaluation of renal arteries. Examination quality is essential for the diagnosis. CTA is limited in its ability to visualize the branches of the renal artery and accessory arteries. CTA seems to be superior to IVDSA.

Adult↗

Hemodynamic evaluation before and after the STA-MCA anastomosis--with special reference to measurement of regional transit time with intra-arterial digital subtraction angiography.

Twenty-seven patients with minor completed and major stroke in the chronic stage underwent superficial temporal artery-middle cerebral artery (STA-MCA) anastomosis. The regional cerebral blood flow (rCBF), using inhalation of stable xenon and computed tomographic scanning (Xes CT-CBF study), and the mode of transit time (MTT) in the MCA territory using intra-arterial digital aortography were measured. Activated rCBF and MTT was measured 20 minutes after the administration of acetazolamide (10 mg/kg) in 14 patients. Nineteen of the 23 patients with minor stroke (Group 1) showed immediate improvement in their neurological state within a few days of the operation, while four patients with minor stroke (Group 2) and four patients with major stroke (Group 3) showed no improvement. Based on the rCBF obtained with the Xes CT-CBF study, affected side rCBF/unaffected side rCBF and %f [(peak DSA number/affected side MTT)/(peak DSA number/unaffected side MTT)] were compared. There was a significant positive correlation. Affected side MTT in Group 1 was 6.41 +/- 1.16 sec, preoperatively, and significantly decreased to 5.13 +/- 0.91 sec after the operation. On the other hand, preoperative MTT in Group 2 was 4.40 +/- 0.81 sec and 4.76 +/- 0.89 sec, postoperatively. Preoperative %f in Group 1 was 0.514 +/- 0.143 and significantly increased to 0.739 +/- 0.154, postoperatively. Group 2 showed no change. Vasodilatory capacity with acetazolamide showed a marked improvement in Group 1, postoperatively. Our study indicated that if MTT is moderately lengthened, %f is moderately decreased, and vasodilatory capacity is impaired, in patients with minor ischemic stroke will benefit from STA-MCA anastomosis.

Angiography, Digital Subtraction↗

Contrast-enhanced subtraction MR angiography in occlusive disease of the pelvic and lower limb arteries: results of a prospective intraindividual comparative study with digital subtraction angiography in 76 patients.

PURPOSE: The purpose of this work was to evaluate the feasibility and clinical use of MR angiography (MRA) for examining the pelvic and lower limb arteries in patients with arterial occlusive disease. METHOD: Seventy-six patients with clinical signs of peripheral arterial occlusive disease were included in the study. MRA was performed using a fast contrast-enhanced high-resolution 3D technique that covered the area from the distal abdominal aorta to the distal lower limbs in two examination steps. RESULTS: In all patients, diagnostic images comparable with those of conventional intraarterial digital subtraction angiography (DSA) could be obtained. No false-negative findings were seen in the iliac, femoral, or popliteal arteries. Ten to 16% of the mild stenoses and 6-14% of the severe stenoses, mainly in the crural vessels, were overgraded compared with intraarterial DSA. Particularly in patients with proximal severe obstructions or occlusions, the crural segments could be depicted more clearly due to decreased arterial runoff in conventional angiography. CONCLUSION: The consistency of the excellent depiction of the vascular territories of the distal aorta and the pelvic and lower limb arteries in a standardized setting suggests great potential for the use of MRA in the primary diagnosis of peripheral arterial occlusive disease.

Aged↗

Renal vasculature in potential renal transplant donors: comparison of MR imaging and digital subtraction angiography.

PURPOSE: To compare magnetic resonance (MR) angiography with a selective inversion-recovery sequence and digital subtraction angiography (DSA) in renal transplant donors. MATERIALS AND METHODS: Thirteen potential donors underwent MR imaging at 1.5 T and conventional angiography. Blinded evaluation of imaging findings was performed. A selective inversion-recovery sequence was used to obtain MR arteriograms. RESULTS: Eight accessory vessels were present; MR angiography showed 100% sensitivity in accessory vessel detection. Both studies depicted early arterial branching in two vessels, mild fibromuscular dysplasia in one patient, normal renal size in all patients, and prominent fetal lobulation in two kidneys. A small cyst was detected with MR imaging only. Minor venous anomalies were noted in three patients, though these were not surgically confirmed owing to contralateral surgery. CONCLUSION: Despite the small study population, MR angiography with this sequence appears to have potential value in pretransplantation evaluation of the kidney. Advantages include short examination time, noninvasiveness, avoidance of iodinated contrast media, no radiation, and lower cost than DSA.

Adult↗

Cerebral veins: comparative study of CT venography with intraarterial digital subtraction angiography.

BACKGROUND AND PURPOSE: Our objective was to compare the reliability of CT venography with intraarterial digital subtraction angiography (DSA) in imaging cerebral venous anatomy and pathology. METHODS: In 25 consecutive patients, 426 venous structures were determined as present, partially present, or absent by three observers evaluating CT multiplanar reformatted (MPR) and maximum intensity projection (MIP) images. These results were compared with the results from intraarterial DSA and, in a second step, with the results of an intraobserver consensus. In addition, pathologic conditions were described. RESULTS: Using DSA as the standard of reference, MPR images had an overall sensitivity of 95% (specificity, 19%) and MIP images a sensitivity of 80% (specificity, 44%) in depicting the cerebral venous anatomy. On the basis of an intraobserver consensus including DSA, MPR, and MIP images (415 vessels present), the sensitivity/specificity was 95%/91% for MPR, 90%/100% for DSA, and 79%/91% for MIP images. MPR images were superior to DSA images in showing the cavernous sinus, the inferior sagittal sinus, and the basal vein of Rosenthal. Venous occlusive diseases were correctly recognized on both MPR and MIP images. Only DSA images provided reliable information of invasion of a sinus by an adjacent meningioma. CONCLUSION: CT venography proved to be a reliable method to depict the cerebral venous structures. MPR images were superior to MIP images.

Adult↗

Intravenous digital subtraction angiography in the management of peripheral vascular disease.

All patients undergoing peripheral injection intravenous digital subtraction angiography (ivDSA) for peripheral vascular disease during 1987 have been reviewed (140 patients). The radiological distribution of disease was aorto-iliac occlusive (AI) 36 (23%), femoropopliteal (FP) 68 (44%), mixed AI/FP 36 (23%). Clinical diagnosis was correct for AI disease in 92%, for FP disease in 65% and for mixed AI/FP disease in 47%. ivDSA was the only investigation required for management in 111 of all 140 patients (79%), and in 33 of the 36 patients with AI disease (92%), but was less accurate in defining femoropopliteal disease, 22 patients (32%) requiring additional arteriography. Conventional arteriography was performed in 200 patients in 1982 compared with 100 in 1987. ivDSA is particularly suitable for the investigation of AI disease, a condition which is accurately detected by clinical examination, with a reduction in morbidity and bed occupancy.

Angiography, Digital Subtraction↗

Experience of intravenous digital subtraction angiography (IV-DSA) in evaluation of neoadjuvant chemotherapy for advanced breast cancer.

Intravenous digital subtraction angiography (IV-DSA) was performed before and after neoadjuvant chemotherapy (NACT) in five patients with locally advanced breast cancer, and the efficacy of NACT was evaluated on the basis of the results of IV-DSA and histopathological examination. Following NACT, the maximum density of tumor enhancement (MAX) in the IV-DSA image decreased by 61.6% in case 1, 50% in case 2, 58.1% in case 3, 90.8% in case 4, and 97.2% in case 5. In all five patients, the efficacy of chemotherapy was rated as a partial response in terms of tumor size, while histological efficacy was rated as slightly effective in cases 1-4 and moderately effective in case 5. The pathological efficacy of NACT was highest in case 5, which showed the greatest decrease in MAX. These results indicate that variations in MAX reflect clinical efficacy, and, to some extent, also permit prediction of pathological efficacy.

Angiography, Digital Subtraction↗

Experimental examination of videodensitometry of large opacifications in digital subtraction angiography.

With the recent introduction of digital radiography the possibility of extracting clinically useful quantitative indices of function has emerged. In digital subtraction angiography (DSA), videodensitometric analysis has been widely applied. An experimental investigation of the usefulness of logarithmically transformed pixel values in DSA images for quantitative densitometry is performed. Dependence on image uniformity, transmittance, scattered radiation and video offset voltages is examined. Results indicate independence of both uniformity and transmittance and dependence on both scattered radiation and offset voltages. The possible use of lead absorbers to derive corrections for contributions from scattered radiation and similar aberrations in each image used for subtraction is also examined. Observations indicate that such corrections can allow accurate videodensitometry.

Angiography↗

Intraoperative spinal digital subtraction angiography: technique and results.

OBJECTIVE: To evaluate technical and methodological aspects of intraoperative spinal digital subtraction angiography (ISDSA) in our clinical practice and to assess its practicability, safety, and accuracy for the surgical treatment of spinal vascular malformations. METHODS: Between August 1997 and February 2002, a total of 30 patients were treated either surgically (n = 18) or endovascularly (n = 12) for spinal vascular lesions at our institution. The clinical records of five patients who underwent ISDSA were analyzed retrospectively. The thoracic segment was involved in three patients and the medullary cone in two. RESULTS: ISDSA could be performed in four cases. In one patient, the segmental artery could not be probed sufficiently while the patient was prone. No complications occurred from the application of ISDSA. The method was beneficial for the neurosurgeon in all but one patient because the vascular anatomy of the malformation was shown with respect to the surgical approach, including the nidus, and immediate resection control could be performed before wound closure. The duration of the procedure was prolonged by 45 minutes on average. CONCLUSION: ISDSA is safe and effective, especially in surgery for complex vascular and recurrent malformations. Benefits to the patient outweigh the additional expense and prolongation of the surgical procedure.

Adolescent↗

[Digital subtraction angiography in the diagnosis of Fallot 's tetralogy].

The authors analyze the efficacy of digital subtraction angiography (DSA) in the diagnosis of Fallot's tetralogy (FT); this method helps simplify and cut down the scope of investigations but does not deteriorate their informative value. DSA findings in 120 patients with TF are analyzed. The study was confined to right ventriculography in the majority of cases, which permitted clear-cut imaging of the anatomical details of the defect due to computer processing of the image. Morphometrical parameters were used to make assessment of involvement of the pulmonary artery system more objective: the ratio of the width of various portions of the pulmonary artery system to the width of descending aorta and the pulmonary arterial index characterizing the area of section of both pulmonary arteries in relation to body surface. The quality of imaging the stenoses and hypoplasia in the pulmonary artery system was high, meeting the requirements of present-day surgery. Moreover, DSA helps diagnose other anatomical particulars of TF and the concomitant defects and abnormalities, left ventricular hypoplasia and the type of right aortic arch among other things. The advantages of DSA in the diagnosis of TF are a lesser volume of catheterization, reduced number of sessions and of the dose of contrast agent infused at each session, better imaging of the anatomical details of the defect and of concomitant defects and abnormalities. All this permit examinations on an outpatient basis.

Adolescent↗

In-vivo validation of videodensitometric coronary cross-sectional area measurement using dual-energy digital subtraction angiography.

Previous studies indicate that conventional geometric edge detection techniques, used in quantitative coronary arteriography (QCA), have significant limitations in quantitating coronary cross-sectional area of small diameter (D) vessels (D < 1.00 mm) and lesions with complex cross-section. As a solution to this problem, we have previously reported on an in-vitro validation of a videodensitometric technique that quantitates the absolute cross-sectional area including small vessel diameter (D < 1.00 mm) and any complex shape of the vessel cross-section. For in-vivo validation, plastic tubing (5-8 mm long) with different shape complex cross-section with known cross-sectional area (A = 0.8-4.5 mm2) were percutaneously wedged in the coronary arteries of anesthetized pigs (40-50 kg). Contrast material injections (6-10 ml at 2-4 ml/sec) were made into the left main coronary artery during image acquisition using a motion immune dual-energy subtraction technique, where low and high X-ray energy and filtration were switched at 30 Hz. A comparison was made between the actual and measured cross-sectional area using the videodensitometry and edge detection techniques in tissue suppressed energy subtracted images. In eighteen comparisons the videodensitometry technique produced significantly improved results (slope = 0.87, intercept = 0.24 mm2, r = 0.94) when compared to the edge detection technique (slope = 0.42, intercept = 1.99 mm2, r = 0.39). Also, a cylindrical vessel phantom (D = 1.00-4.75 mm) was used to test the ability to calculate and correct for the effect of the out of plane angle of the arterial segment on the cross-sectional area estimation of the videodensitometry technique. After corrections were made for the out of plane angle using two different projections, there was a good correlation between the actual and the measured cross-sectional area using the videodensitometry technique (slope = 0.91, intercept = 0.11 mm2, r = 0.99). These data suggest that it is possible to quantitate absolute cross-sectional area without any assumption regarding the arterial shape using videodensitometry in conjunction with the motion immune dual-energy subtraction technique.

Angiography, Digital Subtraction↗

Portable digital subtraction angiography in the operating room and intensive care unit.

A simple, inexpensive method of portable digital subtraction angiography (DSA) using an image processor (Sigma X), still-videorecorder and control panel combined with a surgical x-ray television unit can provide real time subtraction images on the monitor. This portable DSA unit was used in 161 cases (130 in the operating room and 31 in the intensive care unit). In the operating room it is useful: 1) to confirm patency of the parent artery and its branches after aneurysm clipping, 2) to identify feeding arteries of arteriovenous malformation and to confirm total extirpation, 3) to confirm the patency of extracranial-intracranial bypass, 4) to confirm patency of the internal carotid artery and absence of flap formation after carotid endarterectomy. In the intensive care unit, it is particularly useful for visualizing cerebral vasospasm after subarachnoid hemorrhage and recanalization of an occluded major intracranial artery. Absence of intracranial circulation can be demonstrated in patients with suspected brain death.

Angiography, Digital Subtraction↗

Magnetic resonance angiography of extracranial carotid and vertebral arteries, including their origins: comparison with digital subtraction angiography.

Although carotid bifurcation stenoses are not the only lesions of the extracranial cerebral arteries, magnetic resonance angiographic (MRA) studies to date have concentrated on the carotid bifurcation. We compared digital subtraction angiography of the extracranial portions of the cerebral arteries with MRA using an ordinary body coil, the time-of-flight method, and multiple transverse slabs which covered the arteries down to the aortic arch. Twenty-two patients (15 with arteriosclerotic diseases, 4 with aortitis, and 3 with tumours) had MRA using a 1.5 T magnet system with a three-dimensional fast imaging with steady state precession (FISP) technique. Thirty-nine carotid and 39 vertebral arteries were assessed by three radiologists with regard to stenoses or occlusions, graded as normal, mild (< 30%), moderate (30-60%) or severe (> 60%) stenosis, or occluded. Grading corresponded well in 81%; stenoses appeared more marked on MRA in 14% and were seen less clearly on MRA in 5%. When 26 carotid bifurcations were assessed separately, grading corresponded well in 95%. MRA is the only method which can display the whole course of the extracranial carotid and vertebral arteries non-invasively and satisfactorily.

Adolescent↗

[Stenosis of the carotid arteries in digital subtraction angiography].

The quality of intravenous digital subtraction angiograms was sufficient for diagnostic evaluation in 90%. The accuracy of the method was 90% for the internal carotid artery. 40% of the internal carotid arteries showed stenoses, whereas the common and external carotid arteries were not narrowed in 90%. On behalf of these data the authors consider that i.v. DSA of the carotid vessels is a suitable screening method for carotid arterial occlusive disease.

Brain Ischemia↗