PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Computer Peripherals”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

PNSCROLL, a software package for graphical interactive analysis of single channel patch clamp currents and other binary file records: under mouse control.

The PNSCROLL program has been specifically developed for interactively scrolling through binary data files under mouse control, in order to analyse single channel current records and printout, or plot, records and histograms of currents. PNSCROLL requires the use of a Microsoft Mouse and runs on an IBM or IBM-compatible microcomputer operating under MS DOS, ideally with 256K EGA or VGA graphics card and colour display. It will print on Epson dot matrix printers and plot records and histograms on HP plotters and LaserJet laser printers.

Computer Graphics↗

Three-dimensional uniform grid modeling of electrical defibrillation on a data parallel computer.

Finite element modeling has played an increasingly important role in the study of defibrillation. In order to model well the complex anatomical details, a large number of elements are required in the finite element grid, leading to a large set of equations that often cannot be solved effectively with the computational power of conventional computers. In this paper, we describe the use of a data parallel computer to provide the memory and reduction in solution time for solving these large finite element problems. Using a uniform grid and a nodal assembly technique, the discretized problem domain can be mapped efficiently to the parallel computer, allowing the solution of problems with over two million unknowns. The finite element algorithm for a three-dimensional inhomogeneous anisotropic body is described together with its parallel implementation. Test results for a canine torso model constructed from CT images are also presented.

Algorithms↗

Audiophile hardware in vision science; the soundcard as a digital to analog converter.

The design objective was to develop an inexpensive digital to analog (D/A) converter for use in vision science. Soundcards are hardware units that can be integral or can be added to a computer to add sound capability. A soundcard contains D/A converters designed to work in the audio frequency range, typically 20-20,000 Hz. Soundcard outputs are high-pass filtered and thus do not convey sub-audio frequency or dc information. It is possible to circumvent this design feature by programming the desired output waveform as an amplitude modulation of a high frequency carrier, and then demodulating the soundcard output. The circuit, using a 20 kHz carrier, provides precise D/A conversion for the frequency range relevant for vision experiments, dc to 100 Hz, using inexpensive readily available components. The specific application was for 8 channels of D/A conversion using a Macintosh computer running under OS X. The software needed to program stimuli was created using CoreAudio, a library for programming sounds in OS X. Using soundcards on other platforms would not be a problem, as long as there exists a low level library that would enable the wave table to be filled.

Brain↗

Minimal data sets.

Explore the source record for details and available documents.

Data Collection↗

Effect of video display on the grading of diabetic retinopathy.

PURPOSE: Digital images are increasingly being used in ophthalmology. These may be viewed either on thin-film transistor (TFT) or on cathode-ray tube (CRT) displays. However, there is little data showing which is superior. In this study, we compared the performance of CRT and TFT displays for grading of both compressed and uncompressed images of diabetic retinopathy. METHODS: A total of 49 35 mm transparencies of diabetic retinopathy were scanned and compressed. The images comprised 17 with no retinopathy, eight with background, five with preproliferative, and 19 with proliferative retinopathy. Four levels of compression were used: 0, 70, 80, and 90%. A total of 196 randomised images were presented to two masked graders using both TFT and CRT displays under uniform lighting conditions, 2 months apart. The grade of retinopathy was assessed. Statistical analysis of grading accuracy was performed using receiver operator characteristic curves of sensitivity and specificity and the Stuart-Maxwell test for paired, nonparametric data. RESULTS: Both displays showed high sensitivity and specificity for the detection of any retinopathy. For the specific grade of retinopathy, the CRT performed slightly better with a sensitivity of 0.80 for uncompressed images, compared with 0.75 using the TFT. Compression reduced these sensitivities to 0.73 on the CRT and 0.63 on the TFT. Grading of uncompressed images magnified to four times their original size was more accurate on the TFT. CONCLUSIONS: Grading on both displays met sensitivity and specificity criteria proposed by Diabetes UK (formerly British Diabetic Association) for screening of diabetic retinopathy. The CRT generally performed slightly better than the TFT in relation to the detection of the specific grade of retinopathy.

Computer Peripherals↗

Effect of occupational keyboard typing on magnetic resonance imaging of the median nerve in subjects with and without symptoms of carpal tunnel syndrome.

OBJECTIVE: To examine the effects of occupational keyboard typing on median nerve shape and T2 relaxation and on forearm muscle T2 in professional typists with and without symptoms of carpal tunnel syndrome. DESIGN: Based on the Levine Carpal Tunnel Syndrome Symptom Severity scale (LCTSS), 12 female professional typist volunteers were divided into asymptomatic (LCTSS < 1.3, n = 5) and symptomatic (LCTSS > 1.3, n = 7) groups. Magnetic resonance images were acquired from wrist and forearms of all subjects before, immediately after, and 8 hrs after 3 hrs of typing. Forearm muscle T2 and median nerve T2 cross-sectional area and long/short axis ratio were evaluated by blinded observers. RESULTS: There was no difference between groups in any measured variable before typing. Median nerve T2 increased and long/short axis ratio decreased in asymptomatic subjects after typing, but there were no significant changes in symptomatic subjects. T2 increased in finger flexor muscles after typing, but there was no difference in the pattern of muscle T2 changes between groups. CONCLUSION: In magnetic resonance images of the median nerve at the carpal tunnel, swelling and T2 increases from baseline are a normal response to typing and may be less likely to occur in subjects with symptoms of carpal tunnel syndrome.

Adult↗

Stone secrets.

Explore the source record for details and available documents.

Computer Graphics↗

Augmenting holograms.

Explore the source record for details and available documents.

Computer Graphics↗

Comparison of conoscopic, telescopic, and goniometric methods for measuring angular emissions from medical liquid-crystal displays.

Although emissive displays exhibit a quasi-Lambertian emission, the anisotropy of the electro-optic effect that controls light transmission in liquid-crystal displays (LCDs) causes the pixel luminance to vary, sometimes strongly, with the viewing angle. These variations are not identical for all gray levels and can eventually cause gray-scale inversions. We compare methods currently used to measure angular luminance variations in the LCDs: the goniometric method, the telescopic method, and the conoscopic or Fourier-optics method. We show that, although they are the same at the high end of the gray scale, the results of the three methods differ significantly at lower gray levels. In some cases the measured luminance was as much as 38% higher for the conoscopic system, and 26% higher for the telescopic method, than the value obtained with the goniometric approach. This shift in the minimum luminance measurement translates directly into the contrast ratio, affecting the reporting of technical specifications of display systems.

Computer Peripherals↗

Peripheral measurement techniques for the assessment of osteoporosis.

Peripheral measurement techniques have been the first to be developed for the assessment of osteoporosis, and they remain useful. Besides traditional approaches such as radiographic absorptiometry (RA), radiogrammetry, and single-photon absorptiometry (SPA), new peripheral approaches have been developed that offer powerful ways to assess skeletal status in osteoporosis. These include single x-ray absorptiometry (SXA), peripheral dual x-ray absorptiometry (pDXA), peripheral quantitative computed tomography (pQCT), quantitative ultrasound (QUS) techniques, and magnetic resonance imaging (MRI) approaches. This review describes the current role of peripheral imaging techniques vis-à-vis their central imaging counterparts. Peripheral measurement techniques are attractive because equipment cost is substantially lower, radiation exposure is small, and the devices require less space and sometimes are even portable. Additionally, QUS and MRI offer the potential to measure aspects of bone status beyond the limits of bone densitometry. Peripheral techniques represent important diagnostic methods for the assessment of osteoporosis.

Absorptiometry, Photon↗

Exploration of virtual mazes by rhesus monkeys (Macaca mulatta).

A chasm divides the huge corpus of maze studies found in the literature, with animals tested in mazes on the one side and humans tested with mazes on the other. Advances in technology and software have made possible the production and use of virtual mazes, which allow humans to navigate computerized environments and thus for humans and nonhuman animals to be tested in comparable spatial domains. In the present experiment, this comparability is extended even further by examining whether rhesus monkeys (Macaca mulatta) can learn to explore virtual mazes. Four male macaques were trained to manipulate a joystick so as to move through a virtual environment and to locate a computer-generated target. The animals succeeded in learning this task, and located the target even when it was located in novel alleys. The search pattern within the maze for these animals resembled the pattern of maze navigation observed for monkeys that were tested on more traditional two-dimensional computerized mazes.

Animals↗

Joystick acquisition in tufted capuchins (Cebus apella).

A number of nonhuman primate species have demonstrated the ability to use a joystick to control a cursor on a computer screen, yet the acquisition of this skill has not been the focus of systematic inquiry. Here, we examined joystick acquisition in four tufted capuchins under two directional relationships of joystick movement and resultant cursor displacement, isomorphic and inverted. To document the natural history of the acquisition of this skill, we recorded the development of visual tracking of the cursor and body tilting. Rates of acquisition were comparable between the two conditions. After mastering the task in one condition, subjects remastered the task at an accelerated rate in the opposing condition. All subjects significantly increased or maintained high proportions of cursor tracking throughout acquisition. All subjects demonstrated a postural tilt while moving the cursor from the mid-phase of acquisition through task mastery. In the isomorphic condition, all subjects tilted significantly more often in the direction of goal location than in the opposite direction. In three of the four series of tilting that were scored for subjects in the inverted condition, tilting occurred significantly more often toward the direction of goal location than the direction of required hand movement. Together these findings suggest that body tilting participates in the organization of directional movement of the cursor rather than reflecting merely the motoric requirements of the task (to manipulate a joystick).

Animals↗

Behavioral analysis during the forced swimming test using a joystick device.

The behavioral test described by Porsolt in 1977 for screening potential antidepressant drugs is extensively used both in basic research and in the pharmaceutical industry. The measured behavior is the immobility time during the swimming test (preformed in rodents), which decreases upon acute antidepressant treatment. Several research groups have suggested some modifications on the original Porsolt paradigm and its analysis. Nevertheless, there are still inaccuracies resulting from either undefined intermediate behaviors or from considering the movement of the whole body as one unit without analyzing the motion of the limbs. Herein, we propose a novel and simple scoring method, based on continuous measurement of the limbs motion, using a joystick, a computer screen and simple software. We validated the method, using antidepressant drugs and studied examples of false positives and false negatives of the traditional Porsolt paradigm. The proposed method is easy to use, it accounts for all range of movements and the analysis is relatively fast. Moreover, the results obtained using this analysis method show a normal Gaussian distribution in a population of rats (while the traditional Porsolt analysis does not) which allows selective breeding of 'motivated' and 'depressed' lines of animals.

Animals↗

An improved spectral width Doppler method for estimating Doppler angles in flows with existence of velocity gradients.

Doppler angle (i.e., beam-to-flow angle) is an important parameter for quantitative flow measurements. With known Doppler angles, volumetric flows can be obtained by the mean flow velocity times the cross-section area of the vessel. The differences or changes between prestenotic and poststenotic volumetric flows have been quantified as an indicator for assessing the clinical severity of the stenosis. Therefore, several research groups have dedicated themselves to developing user-independent methods to determine automatically the Doppler angle. Nevertheless, most of these methods were developed for narrow ultrasound beam measurements. For small vessels, where the beam width is a significant fraction of the diameter of the vessel, the effect of velocity gradients plays an important role and should not be ignored in the Doppler angle estimations. Accordingly, this paper is concerned with a method for improving the estimation of Doppler angles from spectral width Doppler (SWD) method, but correcting for velocity-gradient broadening that may arise when the beam has a nonzero width. In our method, Doppler angles were firstly calculated by SWD and then were corrected by an artificial neural network (ANN) method to neutralize the contribution of velocity gradient broadening (VGB). This SWD and ANN conjoint method has been successfully applied to estimate Doppler angles from 50 degrees to 80 degrees for constant flows in 10 mm, 4 mm and 1 mm diameter tubes, whose mean flow velocities were 15.3, 19.9 and 25.5 cm/s, respectively, and the achieved mean absolute errors of the estimated Doppler angles were 1.46 degrees , 1.01 degrees and 1.3 degrees.

Blood Flow Velocity↗

An analysis of image segmentation time in beam's-eye-view treatment planning.

In this work we tabulate and histogram the image segmentation time for beam's eye view (BEV) treatment planning in our center. The average time needed to generate contours on CT images delineating normal structures and treatment target volumes is calculated using a data base containing over 500 patients' BEV plans. The average number of contours and total image segmentation time needed for BEV plans in three common treatment sites, namely, head/neck, lung/chest, and prostate, were estimated.

Computer Peripherals↗

NNERVE: neural network extraction of repetitive vectors for electromyography--Part I: Algorithm.

Artificial neural network (ANN) based signal processing methods have been shown to have significant robustness in processing complex, degraded, noisy, and unstable signals. A novel approach to automated electromyogram (EMG) signal decomposition, using an ANN processing architecture, is presented in this paper. Due to the lack of a priori knowledge of motor unit action potential (MUAP) morphology, the EMG decomposition must be performed in an unsupervised manner. An ANN classifier, consisting of a multilayer perceptron neural network and employing a novel unsupervised training strategy, is proposed. The ANN learns repetitive appearances of MUAP waveforms from their suspected occurrences in a filtered EMG signal in an autoassociative learning task. The same training waveforms are fed into the trained ANN and the output of the ANN is fed back to its input, giving rise to a dynamic retrieval net classifier. For each waveform in the data, the network discovers a feature vector associated with that waveform. For each waveform, classification is achieved by comparing its feature vector with those of the other waveforms. Firing information of each MUAP is further used to refine the classification results of the ANN classifier. Then, individual MUAP waveform shapes are derived and their firing tables are created.

Algorithms↗