PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Denture, Partial”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Further aspects of design for distal extension removable partial dentures based on the Kennedy classification.

A supplement to the Kennedy classification of partially edentulous arches for restoration with removable partial dentures has been suggested. Factors affecting denture design relating to the position of the abutment teeth, the symmetry of the edentulous distal extensions, the arch form and the cross-sectional shape of the residual ridges have been discussed and classified. An understanding of the movement of the denture bases in relation to the influence of these factors makes for a rational approach to removable partial denture design and the treatment of complications observed clinically in removable partial denture wearers.

Alveolar Process↗

Repair of a removable partial denture using gold occlusals.

Limited interarch space causes maintenance problems with removable partial dentures. The problem of abrasion and breakage of acrylic resin teeth, the concomitant supraeruption of opposing natural teeth, and possible decrease of vertical dimension of occlusion can be prevented or minimized with cast-gold occlusals. Use of metal occlusals has been advocated on newly constructed removable partial dentures, but not on existing prostheses with severely worn or broken denture teeth. This article describes a repair procedure for a removable partial denture where minimal interarch distance resulted in wear and breakage of denture teeth. A thin, abraded denture tooth that had been repaired numerous times was prepared and covered with a cast gold restoration. The problem of abrasion and breakage of the acrylic resin tooth was solved and the service life of the prosthesis was extended.

Acrylic Resins↗

Immediate replacement removable partial dentures with cobalt-chromium frameworks: rationale, technology and a case report.

The advantages of removable partial dentures with cobalt-chromium frameworks over those made entirely of acrylic resin, in oral health and hygiene, are well documented. However, in cases where teeth are to be extracted for fitting the removable partial denture, a difficulty arises because of the need to test the fit of the removable partial denture framework. The advent of two modern technologies-- laser welding and metal bonding agents -- make it possible to test the fit of the major part of the framework prior to adding additional metal components to support artificial teeth. A case is described in which the four lower incisors were extracted. The main part of the framework was constructed and its fit tested. A second casting was laser-welded to the lingual plate of the first casting to support the artificial incisor teeth. This technique avoids the need to make an acrylic resin temporary denture but incurs the cost of the additional technical work and so the advantages may be considered to be economically neutral.

Adult↗

Late results of treatment with partial dentures. An investigation by questionnaire and clinical examination 13 years after treatment.

Ninety-nine people who were fitted with partial dentures in 1959 were invited to take part in an investigation 13 years later. A questionnaire was answered by fifty-eight, which means a frequency of 81% if allowance is made for an explainable loss. Of the sixty-eight partial dentures in these fifty-eight patients, twenty-three were still being used, fourteen patients had had their original partial dentures replaced by new ones and three by a fixed bridge, while seven had been replaced by complete dentures. Twenty-one were no longer used and had not been replaced. Of the fifty-four patients who originally had a complete upper denture and a partial lower denture, thirty were still available. Following an invitation to take part in a clinical review, twenty-seven (90%) co-operated. Most of the patients were in need of treatment (for caries, periodontitis and/or prosthetic treatment). The periodontal injuries were rarely serious. A correlation was found between good oral hygiene and good results of treatment.

Denture, Complete↗

The effect of clinical experience on dental students' ability to design removable partial denture frameworks.

To determine whether clinical experience influenced dental students' ability to correctly design removable partial denture frameworks, four combinations of six casts depicting various partially edentulous situations were used in the study. The authors independently rated the casts as to the degree of difficulty on a three-point scale. Only those casts for which there were 100% agreement were used. All of the casts that were used had a moderate degree of difficulty rating (level 2). The dental student sample consisted of 34 second-year students who had just completed 98 hours of instruction in removable partial dentures. Each student was given six casts on which to design removable partial denture frameworks. The students were evaluated before clinical experience in removable prosthodontics and after 1 year of removable prosthodontic experience. The results indicated that the dental students made significantly fewer errors in framework design after clinical experience. Errors on two of 13 framework design items were increased postclinically. The increase in errors on these two items may have been the result of a lack of attention to detail or a lack of reinforcement in learning certain basic concepts.

Clinical Clerkship↗

Radiographic detection of porosities in removable partial denture castings.

The purpose of this study was to discern the existence of structural defects in removable partial denture frameworks by means of radiographs. A simple technique was described using a dental radiograph unit and routine periapical dental films. All components of removable partial denture castings were radiographed with different angulations. The visibility of defects was clear. Structural defects were located and classified in two brands of removable partial denture base metal alloys (Ticonium and Nobilium) commonly used in fabrication of removable partial denture castings. The technique described is simple, inexpensive, not time-consuming, and can be implemented with minimum instrumentation. Future studies with this radiographic method for investigation of internal defects in fixed prostheses or dental implants are recommended.

Chromium Alloys↗

Fabrication of a new crown and provisional to an existing removable partial denture.

A method of fabricating a new crown to an existing removable partial denture is described. A press-form plastic shell made from the diagnostic cast provides the outer contours for the abutment tooth, while an acrylic resin coping is fabricated on a die to provide accurate internal adaptation. The acrylic resin coping is seated on the prepared abutment. Autopolymerizing acrylic resin is mixed and placed in the plastic shell that is then placed in the mouth over the coping, forming the acrylic resin crown pattern. The removable partial prosthesis is fitted over the crown pattern intraorally. The pattern is transferred back to the die, the margins are refined, and the casting is completed and finished, avoiding reduction of the established contours. The same plastic shell is used with tooth-shaded acrylic resin to construct a provisional crown directly in the mouth. This technique allows the patient to wear the removable partial denture while the laboratory procedures are completed.

Crowns↗

Clinical effect of removable partial denture prepared by Saddle-Lock hidden-clasp.

OBJECTIVE: To study the method for preparing removable partial denture using Saddle-Lock hidden-clasp and evaluate its clinical effect. METHOD: Casting process was adopted for the preparation of the clasp, which was fixed at the points on the mesial and distal surfaces of the abutment tooth. The clinical records of 305 patients treated with such removable partial dentures were reviewed. RESULTS: Within a follow-up period of 6 years, 295 of the 305 patients retained good abutment condition and were satisfied with the denture that was capable of easy wearing and removing. CONCLUSIONS: Removable partial denture made by Saddle-lock hidden-clasp exhibits good performance in fixation and stability. As an innovation of traditional design of partial denture clasp, it is simple to prepare and well received by the patients with good clinical effect.

Adult↗

Effects of rehabilitation with conventional removable partial dentures on oral health--a cross-sectional study.

The study aims to elucidate the effects on the oral tissues of occlusal rehabilitation through removable partial denture. Sixty eight individuals treated with conventional partial dentures participated in a clinical study of the hygienic conditions around supporting teeth and the partial dentures, the occurrence of increased mobility of supporting teeth and deepened gingival pockets, the incidence of caries, impaired retention and the frequency of use of the prosthesis. A questionnaire was sent out and 84 per cent of the subjects responded anonymously. The results show that the removable partial denture represents a satisfactory method of oral rehabilitation for the individual with a reduced dentition.

Adult↗

Indexing procedures for converting removable partial dentures after extractions while the patient retains the prosthesis.

A new indexing procedure is described for the conversion of removable partial dentures when extraction of additional teeth is planned. Advantages and disadvantages of the indexing procedure are reviewed and compared with traditional treatment options. The new procedure facilitates the use of dental laboratory expertise and facilities and allows the patient to retain the prosthesis throughout the process. A component that includes teeth, denture base segments, and wire or cast clasps is created by the laboratory and attached by the dentist during the extraction visit as a simple denture repair procedure. The procedure can also be used to convert an existing partial denture to an immediate complete denture. Required clinical and laboratory procedures are described.

Acrylic Resins↗

Impression procedures for semiprecision removable partial dentures.

The concept for impressioning procedures for semiprecision removable partial dentures are reviewed. Techniques that are applicable to various situations are examined, and detailed coverage has been given to the advocated impression procedures for the distal-extension semiprecision removable partial denture.

Alveolar Process↗

The tooth-removable partial denture interface.

During the metal finishing phase of removable partial denture construction, metal is removed from all aspects of the casting. The amount removed from areas designed to contact prepared surfaces of abutments is critical to the resulting fit of the partial. Castings were evaluated before and during finishing procedures to measure metal loss at the tooth-removable partial denture interface. Finishing and fitting techniques for controlling the loss of metal are presented.

Calibration↗

Discoloration of a titanium alloy removable partial denture: a clinical report.

With recent advances in dental technology, titanium is currently used for fabrication of crowns, fixed partial dentures, implant frameworks, and removable partial denture frameworks. The use of titanium-aluminum-vanadium (Ti-6Al-4V) alloy assumes that it imparts similar anti-corrosion characteristics to the commercially pure titanium. This clinical report describes a patient who experienced discoloration of a Ti-6Al-4V alloy removable partial denture.

Alloys↗

Variations in a removable maxillary partial denture design by dentists.

Fifty-seven different removable partial denture designs for a patient were submitted by 57 dentists. Many designs were adequate to provide true health service for the patient. Others, however, could prove detrimental if worn by the patient. Dentists should be concerned with partial denture design if patients are to have prostheses that are functional and compatible with the oral environment.

Adult↗

Predictable success with resin bonded fixed partial dentures.

The conservative nature of the resin bonded fixed partial denture is the reason it is used. The ability to replace a missing tooth while avoiding aggressive preparation of the abutment teeth is a desirable concept. The use of conservative preparation forms will aid in the long term predictable success of the resin bonded fixed partial denture.

Denture Design↗

Discuss before fabricating: communicating the realities of partial denture therapy. Part I: patient expectations.

During planning for treatment involving cast removable partial dentures (RPDs), it is important to remember that the 2 major reasons why patients seek this treatment are to improve esthetics and to improve mastication. Treatment that is considered unsuccessful may not necessarily represent poor execution of procedures, but rather may not have fulfilled the patient's expectations with regard to these 2 goals. Searches of the Cochrane Collaboration and MEDLINE databases were conducted to identify issues pertaining to patient compliance in wearing cast RPDs. Compliance was better when the patient's chief concern was replacement of anterior teeth. The success of RPDs for replacement of teeth missing from other areas depended on the patient's perception of the value of such replacement. Maximum masticatory efficiency is equivalent for people functioning from second premolar to second premolar and those wearing partial dentures. Many clinicians believe that the prescription of partial dentures which replace teeth missing distally to the second premolars represents overtreatment.

Denture, Partial, Removable↗

Longitudinal study on forces transmitted from denture base to retainers of lower distal-extension removable partial dentures with conus crown telescopic system.

The purpose of this study was to perform longitudinal measurement of forces transmitted from the denture base to retainers of lower distal-extension removable partial dentures with a conus crown telescopic system. The experimental denture was embedded with a force-detecting unit which could detect a change in lateral and vertical forces transmitted from denture base to retainers at the same time. Forces were measured during chewing of food on several separate occasions from the insertion of new dentures to about 3 months after. Max.ver (maximal mean value of vertical force) and Max.lat (maximal mean value of lateral force) were calculated from the peak level of all strokes of chewing of food at the minimum of the interocclusal distance. The results are summarized as follows: (i) There were no significant changes of Max.ver and Max.lat; (ii) There were no significant differences of Max.ver between subjects the value of which was about 20 N; (iii) There were significant differences of Max.lat between subjects the value of which was less than 15 N.

Bite Force↗

[Cross sectional study of removable partial denture design in general practitioners].

Many reports have been made on statistical observation on prostheses, among which removable partial denture frequently becomes the subject of investigation from the two sides of cross- and longitudinal- sectional surveys, because its constituent factors are divergent. However, many of such reports used, as subject, the removable partial dentures fitted at clinical practices at the hospitals affiliated to dentistry universities (dentistry departments), and it is hard to say that these reports have grasped the actual circumstances in which removable partial denture is involved since each therapeutic principle as educational hospital constitutes its own specific environment, if the fact that difference occurs in the selecting criteria for each constituent factor according to the operators' designing conception and medical environment is taken into consideration. Then, we have made investigation of edentulous pattern and kinds of denture base material and retainers in 141 cases with removable partial denture fitted at general practitioners, and the following conclusions have been reached. 1. Among the direct retainers of free-end denture, those of clasp with distal rest (Aker's clasp) were the largest in number. 2. By base material, among the direct retainers of free-end denture, many of those of Bar type which has mesial rest (RPI clasp) were observed, in case of metal base, compared with resin base, but difference was observed in the frequency of use of the other retainers. 3. Free-end denture held a majority both in the upper and lower jaws. 4. As base material, resin base was overwhelmingly large in number, compared with metal base.

Cross-Sectional Studies↗