PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fractures, Open”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

[External fixation in open fractures].

Author analyses 644 cases of compound fractures managed at the University Department of traumatology, Ljubljana from 1981. do 1987. He examines the incidence of compound fractures and fractures of other types. He analyses the fractures according to the Matter-Rittmann-Algöver classification. Various fixation techniques are described, especially reduction by external fixators used in nearly all grade III compound fractures. The most frequently applied tube-shaped fixator (Synthes) is presented. In 51% of cases external fixation was changed in first three months of treatment. The average length of external fixator application was 4 months, the full weight bearing in average after 7 months. Postoperative bone infection occurred in 4% of cases.

Fracture Fixation↗