SEARCH · PubMed Health
Results for “MOUTH PROTECTORS”
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Influence of awareness of the recording of breathing on respiratory pattern in healthy humans.
This study was designed to test whether awareness of the measurement of breathing influences the breathing pattern in healthy subjects under routine laboratory conditions. Seventy four subjects (40 females and 34 males), aged 21-63 yrs, were studied under three different conditions whilst their breathing was being recorded for 5 min by means of inductance plethysmography (Respitrace): 1) subjects were misled into believing that their breathing was not being recorded but that they had to wait for 5 min whilst equipment was calibrated; 2) subjects were instructed that their breathing pattern was being recorded for 5 min; 3) the subject's breathing was recorded for 5 min with mouthpiece and pneumotachograph. The first two conditions were randomized. The Respitrace was calibrated by means of multiple linear regression carried out during the 5 min period of quiet breathing through a mouthpiece. Awareness of the recording of breathing caused prolongation of inspiratory (tI) and expiratory time (tE). Breathing through the mouthpiece resulted in an increase of tI, tE and tidal volume (VT). The breathing irregularities (sighs and end-expiratory pauses) decreased when subjects were aware of the recording of breathing and nearly disappeared when subjects breathed through the mouthpiece. The end-tidal carbon dioxide concentration was not significantly different between the three conditions. Mouthpiece breathing often induced some respiratory discomfort and even anxiety, particularly in females. Awareness by the subject that his or her breathing was being recorded altered the spontaneous breathing pattern, mainly the breathing frequency. In addition, use of a mouthpiece markedly increased tidal volume, particularly in females in whom mouthpiece breathing induced more complaints than in males.
Unsteadiness of breathing in patients with hyperventilation syndrome and anxiety disorders.
The breathing pattern of 399 patients with hyperventilation syndrome (HVS) and/or with anxiety disorders and that of 347 normal controls was investigated during a 5 min period of quiet breathing and after a 3 min period of voluntary hyperventilation. The diagnosis of HVS was based on the presence of several suggestive complaints occurring in the context of stress, and reproduced by voluntary hyperventilation. Organic diseases as a cause of the symptoms were excluded. The anxiety disorders were diagnosed by means of an abbreviated version of the Anxiety Disorders Interview Schedule (ADIS). There was a large overlap between the two diagnoses. Simply breathing via a mouthpiece and pneumotachograph made end-tidal CO2 fractional concentration (FET,CO2) decrease progressively both in hyperventilators and in patients with anxiety disorders, but not in normals. At the start of the measurement the FET,CO2 was not different between patients and healthy subjects. In patients < or = 28 yrs, the decrease of FET,CO2 resulted from a higher tidal volume, and in patients > or = 29 years from an increase in frequency. After voluntary hyperventilation, the recovery of FET,CO2, was delayed in patients, due to a slower normalization of respiratory frequency in females and in older males, and of tidal volume in younger males, and also due to less frequent end-expiratory pauses. When breathing was recorded first by means of inductive plethysmography (Respitrace), the progressive decline of FET,CO2 seen in patients was not observed: from the onset of the recording, FET,CO2 was reduced in patients. It did not change further when, immediately afterwards, the subject switched to mouthpiece breathing. The finding that breathing through a mouthpiece induces hyperventilation in patients and that recovery of FET,CO2 is delayed after voluntary hyperventilation, suggests that the respiratory control system is less resistant to challenges (mouthpiece or voluntary hyperventilation) in those patients. On the other hand, the lower values of FET,CO2 measured during recording by means of a Respitrace probably result from a challenge, prior to the recordings, induced by the fitting of the measuring device to the patient. This unsteadiness of breathing characterizes patients with hyperventilation syndrome and those with anxiety disorders, but is not sufficiently sensitive to be used for individual diagnosis.
Influence of maxillary mouthguards on physiological parameters.
INTRODUCTION: The purpose of this study was to test the influence of two types of maxillary mouthguards (a self-adapted and a custom-made model: SA and CM, respectively) on various physiological parameters generally associated with performance in team sports. METHODS: Nineteen trained male subjects participating in team sports were tested. Visual reaction time, explosive power, ventilation at rest, and ventilation and oxygen consumption during submaximal and maximal exercise were measured in three randomized conditions: normal, with SA mouthguards, or with CM mouthguards. RESULTS: Wearing SA or CM mouthguards did not significantly alter any of the measured parameters compared with the normal condition. CONCLUSIONS: Wearing a maxillary mouthguard does not affect the main physiological parameters generally associated with team sport performance. These results provide additional support to the policy of encouraging athletes to wear individually fitted maxillary mouthguards.
Self-made tooth guard using Turbocast.
Tooth protection during suspension microlaryngeal surgery is a challenge when teeth are damaged or missing. We present an effective, disposable and cheap tooth guard for microlaryngeal surgical procedures using Turbocast. The tooth guard transits the laryngoscope's pressure directly to the hard palate leaving the teeth uninvolved and free of any pressure.
Lip injury prevention during tonsillectomy.
Patients commonly complain of discomfort at the angle of the mouth following tonsillectomy. This can be attributed to trauma sustained during the procedure. A prospective, patient-blinded, controlled trial of 34 tonsillectomies was performed using a protective, plastic oral guard. A blinded observer recorded postoperative pain and clinically evident trauma to the angle of the mouth. The patient group in whom the guard was used had a significantly lower incidence of labial trauma (p<0.002) and complained of pain less frequently (p<0.002) when compared with a control group in whom no guard was used. The use of a protective lip guard during tonsillectomy is recommended.
Dental protection during rigid endoscopy.
Explore the source record for details and available documents.
Measurement of maximal static respiratory pressures at the mouth with different air leaks.
The effect of two different circuit leaks on the measurement of maximal static inspiratory and expiratory pressures at the mouth (Pimax, Pemax) was assessed in 70 patients with respiratory disease. Patients were divided into three groups with similar anthropometric and spirometric characteristics. The first group (30 patients) had their Pmax measured with a leak of 2.0 mm internal diameter (ID) and 37 mm length (as proposed by T. Ringqvist) and repeated with a second leak of 1.0 mm ID and 15 mm length (as recommended by J. L. Clausen). The two measurements were done in random order. Measurements for the other two groups (20 patients each) were taken with one or another, the two leaks randomly alternated with no leak. Pimax measurements obtained with Ringqvist's leak were 17 percent (p less than 0.005) lower than those with Clausen's leak and 22 percent (p less than 0.005) lower than those with no leak. Pemax measurements performed with Ringqvist's leak in place were 11 percent (p less than 0.005) lower than those with Clausen's leak and 11 percent (p less than 0.005) lower than those obtained with no leak. The comparison between Clausen's leak and no leak showed no statistically significant difference. We conclude that whenever the effect of pressure generated in the mouth is to be avoided in the measurement of respiratory Pmax, a leak of the size proposed by Ringqvist is to be preferred.
Successful treatment of central sleep apnea with an oral prosthesis.
Two cases of polygraphically defined central sleep apnea were successfully treated with the tongue retaining device, an oral prosthesis designed to reduce hypopharyngeal obstruction. The tongue retaining device may be an alternative to CPAP in the treatment of some cases of central sleep apnea.
Intermittent positive pressure ventilation via the mouth as an alternative to tracheostomy for 257 ventilator users.
Despite wider application of the use of nocturnal intermittent positive pressure ventilation (IPPV) via nasal access for the management of nocturnal hypoventilation, there continues to be a lack of familiarity with the use of IPPV via the mouth for ventilatory support. Unlike nasal IPPV, which is generally practical only for nocturnal use, up to 24-h mouth IPPV was the key method of noninvasive ventilatory support that permitted the avoidance or elimination of tracheostomy for 257 individuals with acute or chronic ventilatory failure. Mouth IPPV was delivered via commercially available mouthpieces for daytime aid and mouthpiece with lip seal or custom orthodontic interfaces for nocturnal support. The use of mouth IPPV alone or in a regimen with other noninvasive ventilatory aids was reviewed for these 257 individuals. Mouth IPPV was used for nocturnal aid by 163 individuals, 61 of whom had little or no measurable vital capacity or significant ventilator-free breathing time, for more than 1,560 patient-years with few complications. It was also the predominant method of daytime ventilatory support for 228 individuals for more than 2,350 patient-years. We conclude that for individuals with adequate bulbar muscle function but chronic respiratory muscle insufficiency, mouth IPPV can be an effective alternative to tracheostomy. It can significantly prolong survival while optimizing convenience, safety, and communication.
Esophageal pressure measurements in cardiopulmonary exercise testing.
STUDY OBJECTIVES: We sought to determine the adaptability and effectiveness of a new esophageal balloon technique to measure changes in esophageal pressure (Pes) as a reflection of pleural pressure with progressive incremental exercise testing in normal subjects. DESIGN: An 8F (0.9 cm) esophageal balloon catheter (Smart Cath; Allied Health Products; Riverside, Calif), a CP-100 pulmonary monitor (BiCore Monitoring Systems PC-100; Irvine, Calif), and a flow transducer (Var flex; Allied Health Products; Riverside, Calif) were connected to a breathing valve (model 2700; Hans-Rudolph Inc; Kansas City, Mo). This apparatus was then used to measure Pes during a graded cardiopulmonary exercise test (CPX) to symptom limitation. SETTING: University-affiliated Veterans Affairs Hospital. PARTICIPANTS: Eight nonsmoking volunteers with normal results of pulmonary function tests. INTERVENTIONS: Plots of deltaPes against pressure time product (PTP), minute ventilation (VE), and oxygen consumption (VO2) were obtained. Pes at baseline, anaerobic threshold (AT), and maximum oxygen consumption (VO2max) were obtained by comparing the Pes measurements from the computer printout to the corresponding breath-by-breath measurements on the CPX. MEASUREMENTS AND RESULTS: The flow transducer (Varflex) connection added only 20 mL of dead space to the standard mouthpiece apparatus. The mean maximum work performance was 203+/-32 W. The mean VO2max was 29+/-9 mL/kg/min. The Pes at AT was 16+/-3 cm H2O. The Pes at maximal exercise was 42+/-16 cm H2O. CONCLUSION: The small esophageal balloon was well tolerated by all subjects. Plots of deltaPes vs PTP, VE, and VO2 demonstrated a linear correlation. This apparatus could be added to the standard CPX to assess the contribution of the diaphragm and respiratory muscles in patients with dyspnea.
Cleft tongue and ulceration of hard palate: complications of oral intubation.
In a prospective study of the complications of endotracheal intubation and tracheotomy, we encountered an unusual complication of oral intubation. This report describes a 32-year-old man who sustained laceration and cleft of the tongue and ulceration of the hard palate as a result of the use of an oral airway in conjunction with oral intubation.
An evaluation of a commercial protective mouthpiece for football players.
Explore the source record for details and available documents.
Peace Corps dental program.
Explore the source record for details and available documents.
Clinical anticaries effect of repeated topical sodium fluoride applications by mouthpieces.
Explore the source record for details and available documents.
Report of a breakthrough in preventive dental care for a National Football League team.
Explore the source record for details and available documents.
Mouthguard materials: their physical and mechanical properties.
Explore the source record for details and available documents.