PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Cell transport via electromigration in polymer-based microfluidic devices.

Electrokinetic transport of Escherichia coli and Saccharomyces cerevisiae (baker's yeast) cells was evaluated in microfluidic devices fabricated in pristine and UV-modified poly(methyl methacrylate)(PMMA) and polycarbonate (PC). Chip-to-chip reproducibility of the cell's apparent mobilities (micro(app)) varied slightly with a RSD of approximately 10%. The highest micro(app) for baker's yeast cells was observed in UV-modified PC with 0.5 mM PBS (pH = 7.4), and the lowest was measured in pristine PMMA with 20 mM PBS (pH = 7.4). Baker's yeast in all devices migrated toward the cathode because of their smaller electrophoretic mobility compared to the EOF. In 0.5 mM and 1 mM PBS, E. coli cells migrated toward the anode in all cases, opposite to the direction of the EOF due to their larger electrophoretic mobility. E. coli cells in 20 mM PBS migrated toward the cathode, which indicated that the electrophoretic mobility of E. coli cells decreased at higher ionic strengths. Observed differential migrations of E. coli and baker's yeast cells in appropriately prepared polymer microchips were used as the basis for selective introduction into microfluidic devices of only one type of cell. As a working model, experiments were performed with E. coli and RBCs (red blood cells). RBCs migrated toward the cathode in pristine PMMA with 1 mM and 20 mM PBS (pH = 7.4), opposite to the direction of the E. coli cells. By judicious choice of the buffer concentration in which the cell suspension was prepared and the polymer material, RBCs or E. coli cells were selectively introduced into the microdevice, which was monitored via laser backscatter signals.

Cells↗

Microfluidic biosensing systems. Part II. Monitoring the dynamic production of glucose and ethanol from microchip-immobilised yeast cells using enzymatic chemiluminescent micro-biosensors.

A microfluidic flow injection (microFIA) system was employed for handling and monitoring of cell-released products from living cells immobilised on silicon microchips. The dynamic release of glucose and ethanol produced from sucrose by immobilised Saccharomyces cerevisiae cells was determined using microchip biosensors (micro-biosensors) with either co-immobilised glucose oxidase-horseradish peroxidase (GOX-HRP), or alcohol oxidase-horseradish peroxidase (AOX-HRP), catalysing a series of reactions ending up with chemiluminescence (CL) generated from HRP-catalysed oxidation of luminol in presence of p-iodophenol (PIP). The yeast cells were attached by first treating them with polyethylenimine (PEI) followed by adsorption to the microchip surface. The cell loss during assaying was evaluated qualitatively using scanning electron microscopy (SEM), showing that no cells were lost after 35 min liquid handling of the cell chip at 10 microl min(-1). The enzymes were immobilised on microchips via PEI-treatment followed by glutaraldehyde (GA) activation. The GOX-HRP micro-biosensors could be used during five days without any noticeable decrease in response, while the AOX-HRP micro-biosensors showed continuously decreasing activity, but could still be used employing calibration correction. The glucose and ethanol released from the immobilised yeast chips were quantitatively monitored, by varying the incubation time with sucrose, showing the possibilities and advantages of using a microfluidic system set-up for cell-based assays.

Biosensing Techniques↗

Multi-step synthesis of nanoparticles performed on millisecond time scale in a microfluidic droplet-based system.

This paper reports a plug-based, microfluidic method for performing multi-step chemical reactions with millisecond time-control. It builds upon a previously reported method where aqueous reagents were injected into a flow of immiscible fluid (fluorocarbons)(H. Song et al., Angew. Chem. Int. Ed., 2003, 42, 768). The aqueous reagents formed plugs--droplets surrounded and transported by the immiscible fluid. Winding channels rapidly mixed the reagents in droplets. This paper shows that further stages of the reaction could be initiated by flowing additional reagent streams directly into the droplets of initial reaction mixture. The conditions necessary for an aqueous stream to merge with aqueous droplets were characterized. The Capillary number could be used to predict the behavior of the two-phase flow at the merging junction. By transporting solid reaction products in droplets, the products were kept from aggregating on the walls of the microchannels. To demonstrate the utility of this microfluidic method it was used to synthesize colloidal CdS and CdS/CdSe core-shell nanoparticles.

Cadmium Compounds↗

Molded polyethylene glycol microstructures for capturing cells within microfluidic channels.

The ability to control the deposition and location of adherent and non-adherent cells within microfluidic devices is beneficial for the development of micro-scale bioanalytical tools and high-throughput screening systems. Here, we introduce a simple technique to fabricate poly(ethylene glycol)(PEG) microstructures within microfluidic channels that can be used to dock cells within pre-defined locations. Microstructures of various shapes were used to capture and shear-protect cells despite medium flow in the channel. Using this approach, PEG microwells were fabricated either with exposed or non-exposed substrates. Proteins and cells adhered within microwells with exposed substrates, while non-exposed substrates prevented protein and cell adhesion (although the cells were captured inside the features). Furthermore, immobilized cells remained viable and were stained for cell surface receptors by sequential flow of antibodies and secondary fluorescent probes. With its unique strengths in utility and control, this approach is potentially beneficial for the development of cell-based analytical devices and microreactors that enable the capture and real-time analysis of cells within microchannels, irrespective of cell anchorage properties.

Animals↗

"Microcanals" for micropipette access to single cells in microfluidic environments.

We demonstrate the fabrication and operation of "microcanals"(i.e. open-air microfluidic channels without a roof), which enable micropipette manipulation and probing of cells within a microfluidic environment. The microcanal devices are fabricated in PDMS on glass substrates using a PDMS membrane transferring technique. Here we show patch-clamp electrophysiological recording and intracellular dye injection performed on cells seeded in microcanals.

Animals↗

Perfusion and chemical monitoring of living cells on a microfluidic chip.

A microfluidic device that incorporates continuous perfusion and an on-line electrophoresis immunoassay was developed, characterized, and applied to monitoring insulin secretion from single islets of Langerhans. In the device, a cell chamber was perfused with cell culture media or a balanced salt solution at 0.6 to 1.5 microL min(-1). The flow was driven by gas pressure applied off-chip. Perfusate was continuously sampled at 2 nL min(-1) by electroosmosis through a separate channel on the chip. The perfusate was mixed on-line with fluorescein isothiocyanate-labeled insulin (FITC-insulin) and monoclonal anti-insulin antibody and allowed to react for 60 s as the mixture traveled down a 4 cm long reaction channel. The cell chamber and reaction channel were maintained at 37 degrees C. The reaction mixture was injected onto a 1.5 cm separation channel as rapidly as every 6 s, and the free FITC-insulin and the FITC-insulin-antibody complex were separated under an electric field of 500 to 600 V cm(-1). The immunoassay had a detection limit of 0.8 nM and a relative standard deviation of 6% during 2 h of continuous operation with standard solutions. Individual islets were monitored for up to 1 h while perfusing with different concentrations of glucose. The immunoassay allowed quantitative monitoring of classical biphasic and oscillatory insulin secretion with 6 s sampling frequency following step changes in glucose from 3 to 11 mM. The 2.5 cm x 7.6 cm microfluidic system allowed for monitoring islets in a highly automated fashion. The technique should be amenable to studies involving other tissues or cells that release chemicals.

Animals↗

Integrated microelectrode array and microfluidics for temperature clamp of sensory neurons in culture.

A device for cell culture is presented that combines MEMS technology and liquid-phase photolithography to create a microfluidic chip that influences and records electrical cellular activity. A photopolymer channel network is formed on top of a multichannel microelectrode array. Preliminary results indicated successful local thermal control within microfluidic channels and control of lamina position over the electrode array. To demonstrate the biological application of such a device, adult dissociated dorsal root ganglion neurons with a subpopulation of thermally-sensitive cells are attached onto the electrode array. Using laminar flow, dynamic control of local temperature of the neural cells was achieved while maintaining a constant chemical culture medium. Recording the expected altered cellular activity confirms the success of the integrated device.

Action Potentials↗

Macro-to-micro interfaces for microfluidic devices.

Since the concept of miniaturized total analysis systems (microTAS) was invented, a great number of microfluidic devices have been demonstrated for a variety of applications. However, an important hurdle that still needs to be cleared is the connection of a microfluidic device with the rest of the world, which is often referred to as the macro-to-micro interface, interconnect, or world-to-chip interface. In this review, we will examine the methods used by pioneers in the field and other investigators, review the approaches for capillary electrophoresis-based devices and those using pneumatic pumping, and present additional discussion on interface standardization and choosing and designing interconnects for your applications.

Electrophoresis, Capillary↗

Apoptotic cell death dynamics of HL60 cells studied using a microfluidic cell trap device.

This paper presents the design, fabrication and first results of a microfluidic cell trap device for analysis of apoptosis. The microfluidic silicon-glass chip enables the immobilization of cells and real-time monitoring of the apoptotic process. Induction of apoptosis, either electric field mediated or chemically induced with tumour necrosis factor (TNF-alpha), in combination with cycloheximide (CHX), was addressed. Exposure of cells to the appropriate fluorescent dyes, FLICA and PI, allows one to discriminate between viable, apoptotic and necrotic cells. The results showed that the onset of apoptosis and the transitions during the course of the cell death cascade were followed in chemically induced apoptotic HL60 cells. For the case of electric field mediated cell death, the distinction between apoptotic and necrotic stage was not clear. This paper presents the first results to analyse programmed cell death dynamics using this apoptosis chip and a first step towards an integrated apoptosis chip for high-throughput drug screening on a single cellular level.

Apoptosis↗

Denaturing gradient-based two-dimensional gene mutation scanning in a polymer microfluidic network.

An integrated two-dimensional (2-D) DNA separation platform, combining standard gel electrophoresis with temperature gradient gel electrophoresis (TGGE) on a polymer microfluidic chip, is reported. Rather than sequentially sampling DNA fragments eluted from standard gel electrophoresis, size-resolved fragments are simultaneously electrokinetically transferred into an array of orthogonal microchannels and screened for the presence of sequence heterogeneity by TGGE in a parallel and high throughput format. A bulk heater assembly is designed and employed to externally generate a temporal temperature gradient along an array of TGGE channels. Extensive finite element modeling is performed to determine the optimal geometries of the microfluidic network for minimizing analyte band dispersion caused by interconnected channels in the network. A pH-mediated on-chip analyte stacking strategy is employed prior to the parallel TGGE separations to further reduce additional band broadening acquired during the electrokinetic transfer of DNA fragments between the first and second separation dimensions. A comprehensive 2-D DNA separation is completed in less than 5 min for positive detection of single-nucleotide polymorphisms in multiplex PCR products that vary in size and sequence.

DNA↗

An electrokinetic/hydrodynamic flow microfluidic CE-ESI-MS interface utilizing a hydrodynamic flow restrictor for delivery of samples under low EOF conditions.

A hydrodynamic flow restrictor (HDR) that is used to combine electrokinetic and hydrodynamic flow streams has been fabricated in a microfluidic channel by laser micromachining. Combining electrokinetic and hydrodynamic flow streams is challenging in microfluidic devices, because the hydrodynamic flow often overpowers the electrokinetic flow, making it more difficult to use low electroosmotic flow in the electrokinetic portion of the system. The HDR has been incorporated into a capillary electrophoresis-mass spectrometry interface that provides continuous introduction of a make-up solution and negates the hydrodynamic backpressure in the capillary electrophoresis channel to the extent that low EOF can be utilized. Moreover, the hydrodynamic backpressure is sufficiently minimized to allow coatings that minimize EOF to be used in the electrokinetically driven channel. Such coatings are of great importance for the analysis of proteins and other biomolecules that adsorb to charged surfaces.

Electrophoresis, Capillary↗

A microfluidic-based enzymatic assay for bioactivity screening combined with capillary liquid chromatography and mass spectrometry.

The design and implementation of a continuous-flow microfluidic assay for the screening of (complex) mixtures for bioactive compounds is described. The microfluidic chip featured two microreactors (1.6 and 2.4 microL) in which an enzyme inhibition and a substrate conversion reaction were performed, respectively. Enzyme inhibition was detected by continuously monitoring the products formed in the enzyme-substrate reaction by electrospray ionization mass spectrometry (ESI-MS). In order to enable the screening of mixtures of compounds, the chip-based assay was coupled on-line to capillary reversed-phase high-performance liquid chromatography (HPLC) with the HPLC column being operated either in isocratic or gradient elution mode. In order to improve the detection limits of the current method, sample preconcentration based on a micro on-line solid-phase extraction column was employed. The use of electrospray MS allowed the simultaneous detection of chemical (MS spectra) and biological parameters (enzyme inhibition) of ligands eluting from the HPLC column. The present system was optimized and validated using the protease cathepsin B as enzyme of choice. Inhibition of cathepsin B is detected by monitoring three product traces, obtained by cleavage of the substrate. The two microreactors provided 32 and 36 s reaction time, respectively, which resulted in sufficient assay dynamics to enable the screening of bioactive compounds. The total flow rate was 4 microL min-1, which a 25-fold decrease was compared with a macro-scale system described earlier. Detection limits of 0.17-2.6 micromol L-1 were obtained for the screening of inhibitors, which is comparable to either microtiter plate assays or continuous-flow assays described in the literature.

Cathepsin B↗

A novel crossed microfluidic device for the precise positioning of proteins and vesicles.

Herein we present a novel way to create arrays of different proteins or lipid vesicles using a crossed microfluidic device. The concept relies on the combination of I) a designated two-step surface chemistry, which allows activation for subsequent binding events, and II) crossing microfluidic channels for the local functionalization by separated laminar streams. Besides its simplicity and cost efficiency, this concept has the advantage that it keeps the proteins in a hydrated environment throughout the experiment. We have demonstrated the feasibility of such a device to create a chessboard pattern of different fluorescently labeled lipid vesicles, which offers the possibility to contain biomolecules, drugs or membrane proteins.

Equipment Design↗

Continuous flow in open microfluidics using controlled evaporation.

This paper presents a method for programming the flow rate of liquids inside open microfluidic networks (MFNs). A MFN comprises a number of independent flow paths, each of which starts with an open filling port, has a sealed microchannel in which assays can be performed, and an open capillary pump (CP). The MFN is placed over Peltier elements and its flow paths initially fill owing to capillary forces when liquids are added to the filling ports. A cooling Peltier element underneath the filling ports dynamically prevents evaporation in all filling ports using the ambient temperature and relative humidity as inputs. Another Peltier element underneath the CPs heats the pumps thereby inducing evaporation in the CPs and setting the flow rate in the microchannels. This method achieves flow rates in the microchannels ranging from approximately 1.2 nL s(-1) to approximately 30 pL s(-1), and is able to keep 90% of a 0.6 microL solution placed in an open filling port for 60 min. This simple and efficient method should be applicable to numerous assays or chemical reactions that require small and precise flow of liquids and reagents inside microfluidics.

Capillary Action↗

Microfluidic discharge-based optical sources for detection of biochemicals.

This paper reports a discharge-based optical source for fluorescence of biochemicals in microfluidic systems. Its efficacy is demonstrated using a stacked microchip that integrates a microfluidic wavelength-tunable optical source, a biochemical sample reservoir and optical filters. It is shown to excite fluorescence in l-tryptophan and DNA samples labeled by SYBR green dye. The discharge is struck in ambient air, between a metal anode and a cathode cavity that is filled with an aqueous solution, which is doped with a metal salt selected for its emission characteristics. The characteristic line spectra, which arise from energetic transitions of the metal ions that are sputtered into the glow region of the discharge, are optically filtered and guided to the biochemical sample that resides in a separate on-chip reservoir. For DNA fluorescence, a barium chloride solution is used to emit light at 454 and 493 nm. For tryptophan fluorescence, the cathode contains lead (ii) nitrate solution to provide a 280 nm emission. The resulting fluorescence from the DNA and tryptophan samples is compared to reference data. This technique can also be used to excite other fluorophores by using appropriately doped liquid cathodes having the desired emission characteristics.

Benzothiazoles↗

Construction of microfluidic chips using polydimethylsiloxane for adhesive bonding.

A thin layer of polydimethylsiloxane (PDMS) prepolymer, which is coated on a glass slide, is transferred onto the embossed area surfaces of a patterned substrate. This coated substrate is brought into contact with a flat plate, and the two structures are permanently bonded to form a sealed fluidic system by thermocuring (60 degrees C for 30 min) the prepolymer. The PDMS exists only at the contact area of the two surfaces with a negligible portion exposed to the microfluidic channel. This method is demonstrated by bonding microfluidic channels of two representative soft materials (PDMS substrate on a PDMS plate), and two representative hard materials (glass substrate on a glass plate). The effects of the adhesive layer on the electroosmotic flow (EOF) in glass channels are calculated and compared with the experimental results of a CE separation. For a channel with a size of approximately 10 to 500 microm, a approximately 200-500 nm thick adhesive layer creates a bond without voids or excess material and has little effect on the EOF rate. The major advantages of this bonding method are its generality and its ease of use.

Adhesiveness↗

Mixing with bubbles: a practical technology for use with portable microfluidic devices.

This paper demonstrates a methodology for micromixing that is sufficiently simple that it can be used in portable microfluidic devices. It illustrates the use of the micromixer by incorporating it into an elementary, portable microfluidic system that includes sample introduction, sample filtration, and valving. This system has the following characteristics: (i) it is powered with a single hand-operated source of vacuum, (ii) it allows samples to be loaded easily by depositing them into prefabricated wells, (iii) the samples are filtered in situ to prevent clogging of the microchannels, (iv) the structure of the channels ensure mixing of the laminar streams by interaction with bubbles of gas introduced into the channels, (v) the device is prepared in a single-step soft-lithographic process, and (vi) the device can be prepared to be resistant to the adsorption of proteins, and can be used with or without surface-active agents.

Equipment Design↗

A disposable microfluidic cassette for DNA amplification and detection.

A pneumatically driven, disposable, microfluidic cassette comprised of a polymerase chain reaction (PCR) thermal cycler, an incubation chamber to label PCR amplicons with up-converting phosphor (UPT) reporter particles, conduits, temperature-activated, normally closed hydrogel valves, and a lateral flow strip, was constructed and tested. The hydrogel valves, which were opened and closed with the aid of electrically controlled thermoelectric units, provided a simple means to seal the PCR reactor and suppress bubble formation. The hydrogel-based flow control was electronically addressable, leakage-free, and biocompatible. To test the device, a solution laden with genomic DNA isolated from B. cereus was introduced into the microfluidic cassette and a specific 305 bp fragment was amplified. The PCR amplicons were labelled with the phosphor (UPT) reporter particles, applied to the lateral flow strip, bound to pre-immobilized ligands, and detected with an IR laser that scanned the lateral flow strip and excited the phosphor (UPT) particles that, in turn, emitted light in the visible spectrum. The UPT particles do not bleach, they provide a permanent record, and they readily facilitate the filtering of background noise. The cassette described herein will be used for rapid testing at the point of care.

Hydrogel, Polyethylene Glycol Dimethacrylate↗