Polyester microparticles as a vaccine delivery system for brucellosis: influence of the polymer on release, phagocytosis and toxicity.

Microparticles, containing an antigenic complex from Brucella ovis (HS), were evaluated for vaccine purposes against brucellosis. They were prepared by the double emulsion solvent evaporation method using two different polyesters, poly-lactide-co-glycolide acid (75:25; RG 756) and poly-epsilon-caprolactone. The encapsulation efficiency and release of HS from the microparticles, their capacity to be phagocytosed and also their toxicity on murine monocytes J774.2 were investigated. Both polymers lead to smooth and spherical sub-5 microm particles, with approximately 30% of the antigen initial dose encapsulated. SDS-PAGE and immunoblot of extracted antigens confirmed that the apparent molecular weight and antigenicity remained unaltered after the encapsulation procedure. However, the in vitro release of the antigens differed among them. The release profile for PLGA microparticles was continuous, whereas PEC ones released the antigens in a triphasic release pattern. Phagocytosis was clearly influenced by the hydrophobicity of the polymer, increasing in the case of PEC microparticles. Toxicity assay showed that both types of microparticles induced similar levels of mitochondrial damage. In conclusion, HS-PEC microparticles could be used as an effective vaccine against brucellosis, as the antigen is released in boosters and they are greatly phagocytosed by macrophages.

Animals↗

The effect of spraying and rolling process factors on styrene emission during the application of unsaturated polyester resins.

In recent years the awareness of the problems caused by styrene emission during the processing of unsaturated polyester resins has enlarged. The spray-up application of gel coats is especially problematic, and it produces high styrene emission rates. The emission of styrene has been reduced through material changes, work practice controls, and add-on controls. However, the influence of the spray-up process factors on styrene emission has not been studied before. The aim of this study was to examine possibilities to reduce styrene emission by optimization of spray-up process factors. The following factors were studied under controlled laboratory conditions: orifice size and angle of the spray gun tip, spraying pressure, distance between spray gun and mold, and shape of the mold. The influence of the rolling pattern during lamination was also studied. Several significant factors were found. High pressure and long spraying distance increased both the unit styrene emission and the emission rate. The orifice size had two effects; a large orifice decreased the amount of styrene emitted per sprayed amount of resin but increased the emission rate of styrene. The shape of the mold did not affect the styrene emission. Styrene emission is greater if the entire mold area is rolled. To achieve lower emission is it necessary to roll an area as small as possible; this is especially important if a large mold is laminated. The results showed that emission of styrene can be reduced significantly by an optimal selection of the spray gun settings and the way of working. Optimal settings also increased the transfer efficiency resulting in decreased material loss.

Air Pollutants↗

Porcine insulin biodegradable polyester microspheres: stability and in vitro release characteristics.

The stability of porcine insulin in biodegradable polymers, i.e., poly(DL-lactide-co-glycolide) 50:50 (50:50 DL-PLGA) and poly(L-lactide) (L-PLA) was investigated. Insulin encapsulated microspheres were fabricated from both polymers using double-emulsion-solvent evaporation and emulsion-solvent evaporation techniques and subjected to accelerated stability studies at 40 degrees C and 75% relative humidity. Porcine insulin was found to degrade in all microsphere formulations with an average of < 50% of the initial loading amount remaining intact at the end of 4 weeks. The two major degradation products observed in these formulations were determined to be A-21 desamido insulin and covalent insulin dimer with trace amounts of high molecular weight transformation products. In vitro release studies in phosphate buffered saline at 37 degrees C resulted in very slow and incomplete (< 30% in 30 days) release kinetics for all microsphere formulations. Extraction and analyses of the unreleased insulin within the microspheres revealed that an average of approximately 11% of the encapsulated insulin remained intact. The degradation products observed consisted of approximately 15% of three distinct deamidated hydrolysis products including A-21 desamido insulin, approximately 22% covalent insulin dimer, and trace amounts of high molecular weight transformation products. The degradation of porcine insulin within biodegradable polyester microspheres during stability and release studies can be attributed to the gradual decrease in the pH within the microspheres due to progressive polymer hydrolysis resulting in the production of DL-lactic and glycolic acids. The encapsulation of an acid-base indicator, bromophenol blue, in 50:50 PLGA microspheres (as a probe to estimate pH within the microspheres during accelerated stability studies) indicated that the pH decreased to approximately 3.8 after 3 weeks.

Animals↗

Sulfated polyester interactions with the CD4 molecule and with the third variable loop domain (v3) of gp120 are chemically distinct.

Sulfated polyesters (SP) that inhibit HIV infection interact with both the gp120 binding region of CD4 molecules and with the v3 domain loop of gp120 molecules (gp120/v3) but the contributions of these interactions to the inhibition of HIV env-mediated fusion are presently unclear. In order to characterize the molecular mechanisms by which SP inhibit HIV env-mediated fusion, we studied the effect of SP treatment on env-mediated fusion of CD4+ cells driven by recombinant vaccinia virus (vPE-16) and on the binding of anti-HIV MAbs to cellular gp120 or purified, rgp120. SP were more effective than neutralizing anti-gp120/v3 MAbs in inhibiting env-mediated fusion. In addition, SP interacted with the v3 loop of gp120 to inhibit the binding of the neutralizing MAb 9284 but not the binding of 9305, a neutralizing anti-gp120/v3 MAb that binds to an adjacent epitope. Because SP are polyanions, we compared the chemical properties of the SP-gp120/v3 and SP-CD4 interactions. Whereas the ability of SP to inhibit the binding of MAb 9284 and rgp120 was relatively independent of NaCl concentrations, the ability of SP to interfere with rCD4-rgp120 binding depended on the NaCl concentration and was maximal at low NaCl concentrations. In addition, the SP-gp120 interaction was found to be reversible, in contrast to the SP-rCD4 interaction which was previously shown to be relatively irreversible at low salt. These data are consistent with the notions that the interaction of SP with CD4 is primarily electrostatic, but that the interaction of SP with gp120 has complex characteristics that implicate a role for protein conformation.

Animals↗

The effect of a non-absorbable fat, sucrose polyester, on the metabolism of vitamin A by the rat.

Sucrose polyester (SPE) is a fat-like material that is not absorbed. The effect of this material on vitamin A metabolism was determined by measuring the amount of the vitamin that was stored in the liver of rats following the ingestion of a known amount of vitamin A. In one study, the vitamin A was administered as an oral dose in a vehicle consisting of various proportions of cottonseed oil and SPE. Each 1% replacement of cottonseed oil by SPE resulted in a 0.26% decrease in the amount of vitamin A found in the liver. In the second study, the vitamin A was incorporated into diets in which the fat component consisted of various proportions of cottonseed oil and SPE. When these diets were consumed for 1 week, each 1% replacement of cottonseed oil by SPE resulted in a 0.84% decrease in the storage of vitamin A by the liver. It is proposed that in the lumen of the intestine vitamin A distributes between the customary micellar phase and the unhydrolyzed oil phase of SPE. The vitamin A in this latter phase is eliminated in the feces.

Absorption↗

The benefits of fluoropassivation of polyester arterial prostheses as observed in a canine model.

The effect of treating the surface of a polyester vascular prosthesis with a novel fluoropolymer before sealing the graft with gelatin has been evaluated in a canine thoracoabdominal bypass model. The healing behavior of the Fluoropassiv graft was compared with that of the Gelsoft ERS prosthesis used as control for prescheduled periods of implantation ranging from 4 hr to 6 months. Both series of explanted grafts were analyzed using macroscopic, histologic, and scanning electron microscopic observations, and by determining the prostacyclin/thromboxane A2 ratio (PGI2/TXA2) and the thrombogenicity of the luminal surface by means of labelled platelets and fibrin deposition. Chemical analysis of explanted and cleaned graft segments was performed using electron spectroscopy for chemical analysis, differential scanning calorimetry, and contact angle methods. No difference in platelet and fibrin deposition or PGI2/TXA2 secretion by the luminal surface was observed between the treated and the control grafts at any implantation period. On the other hand, pathologic investigation has revealed that, although there is no difference between the two grafts during the first month, the healing sequence of the Fluoropassiv graft appeared more complete and mature than the control graft after 3 and 6 months. Differences were observed in the extent of collagenous internal capsular development, endothelialization, and tissue penetration into the knitted structure. The presence of fluorine and a higher contact angle at the surface of all the explanted fluoropassivated grafts is believed to have been responsible for reducing the inflammatory response and enhancing the long-term healing behavior of this novel prototype device over the control gelatin sealed prosthesis.

Animals↗

Can collagen impregnated polyester arterial prostheses be recommended as small diameter blood conduits?

A collagen impregnated graft and its parent preclotted prosthesis were implanted as thoraco-abdominal bypasses in dogs for periods ranging from 4 hr to 6 months and evaluated for their ease of handling, imperviousness, and healing behavior in terms of luminal surface thrombogenicity using labeled platelets and fibrinogen, prostacyclin (PGI2) secretion, histomorphometric determination of internal capsule thickness, and histopathologic and scanning electron microscopic studies. The collagen impregnated graft was impervious to blood and both grafts showed excellent handling characteristics. Fibrin uptake was negligible on both grafts; however, platelet uptake was higher on the collagen impregnated graft than on the control graft at 4 and 24 hr. The healing behavior of the collagen impregnated graft was also found to be different than that of the control graft between 1 and 6 months post implantation. The development of a host collagenous internal capsule at the anastomoses, and a confluent endothelial lining, was observed in both grafts at 1 month; in later implantation periods, the healing of the medial region was found to be more irregular in the collagen impregnated grafts, showing a lower mean PGI2 secretion than the preclotted control grafts. Histomorphometric analysis showed the internal capsule on the collagen impregnated grafts to be thicker than on the control grafts for most periods of implantation. The current study illustrates that the healing process of collagen impregnated grafts is delayed and that bovine collagen has a stimulating effect on tissue encapsulation. Current impregnated polyester arterial prostheses therefore cannot be recommended as small diameter blood conduits.

Animals↗

Polyester arterial prostheses. Recent developments from the Czech Republic and Poland.

To evaluate recent developments in the design and production of polyester vascular prostheses in eastern Europe, a series of in vitro physical and chemical tests and an in vivo study was performed on three new prototype devices from the Czech Republic and one from Poland. The in vitro results for these four prostheses, referred to as the Ra-1n (warp knitted, uncrimped), Ra-1v (warp knitted, crimped), Mikrofroté (weft knitted, uncrimped), and Dallon (warp knitted, crimped) prostheses, were compared against values for three commercial devices of western origin, namely the Triaxial, the Vasculour II, and the Cooley II grafts. The animal trial involved implanting the four prototype devices as a thoracoabdominal bypass in dogs for eight different periods ranging from 4 hrs to 6 months and undertaking histologic and structural investigations on the retrieved grafts. Because of its poor long-term dimensional stability in vivo, the continued use of a weft knitted structure, like the Mikrofroté prosthesis, is to be deprecated. Conversely, the introduction of a more dimensionally stable warp knitted structure in three prototypes is to be acknowledged. However, the presence of surface contaminants was most likely responsible for the excessive inflammatory reaction generated by all four prostheses during the first month in vivo, which resulted in delayed healing performance. In addition, an unusually high surface carbon-oxygen ratio suggests that the crimping process needs further refinement. Improved cleaning and packaging procedures are essential before these products can complete against existing commercial prostheses of western origin. In conclusion, these new developments illustrate that the technology of warp knitting, which is now spreading worldwide, should be evaluated.

Animals↗

Easy sellar reconstruction in endoscopic endonasal transsphenoidal surgery with polyester-silicone dural substitute and fibrin glue: technical note.

OBJECTIVE: To describe a simple method of sellar reconstruction after endoscopic endonasal transsphenoidal surgery that will allow rapid watertight closure of the sellar floor. METHODS: A bent sheet of a polyester-silicone dural substitute, fashioned for this purpose with scissors, is introduced into the sella after removal of the lesion. Because of the consistency of the sheet, it opens spontaneously and becomes stuck. Autologous fat tissue or gelatin foam is positioned thereafter, followed by another layer of the dural substitute; a film of fibrin glue completes the sealing. RESULTS: Fifteen patients underwent this method and no postoperative cerebrospinal leak or other complication was experienced. CONCLUSION: This easy method of sellar reconstruction represents an effective and fast possibility to perform the final step of the endoscopic transsphenoidal procedure, which otherwise may cause maneuverability problems in the limited space of one nostril.

Dura Mater↗

Reconstructing the extensor apparatus with a new polyester ligament.

We analyzed the clinical outcome of patients who had reconstruction of the extensor apparatus with a new polyester ligament after extensive resection of malignant tumors around the knee. Twenty-two patients were included; 19 were evaluated after a mean followup of 44 months (range, 8-67 months) to assess active and passive knee range of motion, walking ability, need for revision, and TESS and Enneking scores. The patients were divided into two groups; patients in Group A had a weakened extensor mechanism and patients in Group B had a completely dissected extensor mechanism. Seven patients had excellent knee function with an extension lag less than 5 degrees. Five patients had an extension deficit less than 20 degrees, three patients had a deficit less than 40 degrees, and four patients could not extend their limb against gravity. However, all patients were able to walk without walking aids. They had a mean Enneking score of 83 points and a mean TESS score of 82 points. Patients who had distal femur resections had worse results than patients who had proximal tibia resections. The LARS ligament proved promising for augmentation and complete reconstruction of the extensor apparatus of the knee after extensive tumor resection, with excellent and good results in 59% of patients.

Adolescent↗

A modified technique (using polyester tape) of skin surface biopsy. Its interest for the investigation of athlete's foot.

A technical modification of skin surface biopsy has been introduced by using plastic tape instead of glass as holder, mainly to investigate mycological infections of skin folds. Among various brands of plastic sheets, a polyester film (Melinex O UCB-SIDAC) has been demonstrated as the most suitable. A direct microscopic comparison has been made between our modified technique and conventional scraping as procedures for collecting material from interdigital spaces in 30 patients with bilateral athlete's foot. It has been shown that the skin surface biopsy gives a slightly greater number of positive results (presence of dermatophytes or Candida species) than the conventional scraping technique, although the difference between both techniques is not statistically significant at the 0-05 level (0-05 less than P less than 0-10). Some advantages of the modified skin surface biopsy are emphasized.

Biopsy↗

Clinical use of low porosity woven ultrafine polyester fiber grafts.

A woven fabric graft made of ultrafine polyester fibers (UFPF) (Toray Graft, water porosity: 100 ml/min/cm2:120 mm Hg H2O) was clinically applied in 81 cases (28 thoracic aortic aneurysms, 6 thoracoabdominal aortic aneurysms, 42 abdominal aortic aneurysms, and 5 atherosclerotic obstructions of the peripheral arteries). Eight patients died after surgery due to causes unrelated to the graft. The other 73 patients were in good condition after surgery. For operations requiring extracorporeal circulation, the graft was presealed with human albumin. For the abdominal aortic aneurysms, the graft was preclotted in situ with nonheparinized autoblood after the completion of the proximal anastomosis. It took about 2 min to complete the preclotting. A nonsealed graft was used for the reconstruction of peripheral arteries for the intraaortic balloon pumping procedure. The graft was easy to handle. There was no cut edge fraying problem with the graft in any direction of cutting. Even after presealing, the graft was soft and pliable enough to enable easy adaptation and anastomosis. Just after implantation, bleeding was minimal from the graft wall, anastomotic sites, and suture pores, and it stopped spontaneously. These clinical data showed that the woven UFPF graft exhibited both easy handling despite in spite of low porosity and safe application in the reconstruction of arterial systems even under totally heparinized conditions during extracorporeal circulation.

Aortic Aneurysm↗

The effect of two different bioreactors on the neocartilage formation in type II collagen modified polyester scaffolds seeded with chondrocytes.

The effect of dynamic culture conditions on neocartilage formation in type II collagen modified polyester scaffolds was studied. Porcine or human articular chondrocytes were seeded in the scaffolds. The cell-scaffold constructs were cultivated statically, in a rotating-type bioreactor or in a shaker for up to 4 weeks. The cell proliferation, morphology, NO production, synthesis of proteoglycans and collagen, and mechanical properties were evaluated. The results demonstrated that the rotating-type bioreactor promoted the growth of primary porcine chondrocytes, helped to maintain their phenotype, and increased the production of extracellular matrix. The constructs also had the largest dynamic compressive modulus. In the static condition, chondrocytes occupied only the outer margin of the cell-polymer constructs. The poor mass transfer in static condition may have caused a lower pH value in the middle of the constructs and lead further to faster scaffold degradation as well as the weakest neocartilage. Constructs in the shaker produced the highest amount of NO as well as the lowest amount of cells and matrix production. Human or porcine chondrocytes of the second passage seeded in scaffolds were much less viable, with the largest amount of cells and matrix when cultured in rotating-type bioreactors. A larger seeding density was required to form neocartilage from passaged adult chondrocytes.

Analysis of Variance↗

Evaluation of biodegradable polyesters modified by type II collagen and Arg-Gly-Asp as tissue engineering scaffolding materials for cartilage regeneration.

Synthetic biodegradable polyesters poly(L-lactide) (PLLA) and poly(D,L-lactide-coglycolide) (PLGA) (50:50) modified by porcine type II collagen and an Arg-Gly-Asp (RGD)-containing protein were evaluated as scaffolds for cartilage regeneration in this study. Cytocompatibility of the polymer films was tested using immortalized chondrocytes. Neocartilage formation in vitro on cell-seeded scaffolds was further examined using primary porcine chondrocytes. The inflammatory response of the scaffolds was evaluated subcutaneously in rats. A pilot animal study was conducted, in which rabbit allogeneic chondrocyte-seeded scaffolds were implanted to repair the defected rabbit knee cartilage. The results demonstrated that PLGA as well as its blends with PLLA had better cell growth than pure PLLA, and that type II collagen enhanced, but RGD inhibited cell proliferation. Scaffolds made of blended PLLA/PLGA had larger dynamic compressive modulus compared to scaffolds made of PLLA or PLGA single polymer. Chondrocyte-seeded scaffolds modified by type II collagen without RGD had the greater number of cells as well as higher glycosaminoglycan (GAG) and collagen contents compared to scaffolds without type II collagen modification or scaffolds further modified with RDG. Type II collagen modification prevented infiltration by host tissue and capsule formation. Unmodified PLLA and PLLA/PLGA constructs demonstrated persisting inflammatory response after 6 months, while all type II collagen-modified PLLA/PLGA constructs showed complete repair and no inflammation. Partial or full repair was observed after 2 months of postimplantation in type II collagen-modified PLLA/PLGA constructs, with equal cellularity and 75-80% matrix contents of a normal rabbit articular cartilage. It was concluded that PLLA/PLGA blended scaffolds modified by type II collagen were a potential tissue engineering scaffold for cartilage regeneration.

Analysis of Variance↗

Occupational contact allergy to unsaturated polyester resin cements.

6 men contracted occupational allergic contact dermatitis from unsaturated polyester (UP) cements. 4 of the men were employed in car repair painting and the remaining 2 in mold manufacturing. The exposure time to UP cements ranged from 6 to 32 years before onset of skin symptoms. All patients had eczema on their hands; in addition, 4 had skin symptoms on airborne areas, i.e., wrists, neck and face. All 6 patients developed allergic reactions when patch tested with UP resin at 0.5-10% in petrolatum (pet.). None of the tested patients reacted to auxiliary or cross-linking chemicals of the cements. Diethylene glycol maleate (DGM) was purified and identified from the UP resin of a cement. 1 patient reacting to UP resin was also patch test positive to DGM and he produced an allergic reaction to DGM down to a concentration of 0.0032% pet. DGM was found in both uncured and cured UP resin. None of the patients could continue their work with UP cements after their sensitization.

Adult↗

Co-precipitation of protein and polyester as a method to isolate high molecular weight DNA.

DNA isolation is often the limiting step in genetic analysis using PCR and automated fragment analysis due to low quality or purity of DNA, the need to determine and adjust DNA concentrations after isolation etc. Several protocols have been developed which are either safe and provide good quality DNA or hazardous and provide excellent quality DNA. In this brief communication I describe a new and rapid method of DNA isolation which employs the co-precipitation of protein and polyester, in the presence of acetone, to remove contaminating proteins from a lysed-tissue sample, thus leaving high quality pure DNA. The advantages of this method are increased safety over the phenol:chloroform and the chaotrophic salt methods and increased purity over the salting-out method. Since the concentrations of DNA isolated using this method are relatively consistent regardless of the amount of starting tissue (within limits), adjustments of the DNA concentrations before use as templates in PCR's are not necessary.

Acetone↗

Positive selection systems for discovery of novel polyester biosynthesis genes based on fatty acid detoxification.

The photosynthetic bacterium Rhodobacter capsulatus can grow with short- to long-chain fatty acids as the sole carbon source (R. G. Kranz, K. K. Gabbert, T. A. Locke, and M. T. Madigan, Appl. Environ. Microbiol. 63:3003-3009, 1997). Concomitant with growth on fatty acids is the production to high levels of the polyester storage compounds called polyhydroxyalkanoates (PHAs). Here, we describe colony screening and selection systems to analyze the production of PHAs in R. capsulatus. A screen with Nile red dissolved in acetone distinguishes between PHA producers and nonproducers. Unlike the wild type, an R. capsulatus PhaC- strain with the gene encoding PHA synthase deleted is unable to grow on solid media containing high concentrations of certain fatty acids. It is proposed that this deficiency is due to the inability of the PhaC- strain to detoxify the surrounding medium by consumption of fatty acids and their incorporation into PHAs. This fatty acid toxicity phenotype is used in selection for the cloning and characterization of heterologous phaC genes.

Acetone↗

Mortality of a cohort in a polyamide-polyester factory in Lyon: a further follow up.

In 1981-2 a retrospective study was undertaken in a polyamide-polyester factory in Lyon, France, to evaluate the effect of exposure to phthalates, nickel catalysers, and other chemicals in the work environment. The present paper reports the results of the follow up of this cohort up to July 1986. A slightly increased risk of cancers, in particular of the lung (44 cases), marginally related to exposure category but not significantly related to duration of exposure was found. The excess of skin cancers noted previously has disappeared, whereas an excess of cases of bladder cancer (based on seven cases) may be noted, mainly among nylon workers. The cohort is still young, however, and a continued follow up is likely to yield important information about the potential hazards associated with the nylon and tergal polymer industry.