PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Silicon Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Fracture toughness measurements of some dental core ceramics: a methodologic study.

Fracture toughness is regarded as an important property of dental ceramics. The most widely used methods for fracture toughness (KIc) determination are based on assessment of cracks created by hardness indentations. Different formulas have been developed for KIc calculations and all these methods and formulas include empirical factors based on pure ceramics, i.e. non-composite ceramics. These factors may, however, vary for a specified method for materials with different and complex structure. An important question is whether the various proposed methods and formulas lead to approximately the same numerical KIc values or at least to the same ranking of materials. The aim of this work was to compare two indentation methods and various formulas for calculation of KIc values when used on four commercial composite dental ceramics. The two applied methods and the different formulas showed substantial differences in the obtained values for one and the same material and a different ranking of various materials. It is unknown which method gives the most correct KIc values for these ceramic materials.

Aluminum Oxide↗

Studies on a new carrier of trimethylsilyl-modified mesoporous material for controlled drug delivery.

To better control drug delivery rate, a simple and effective approach has been developed for controlled drug delivery carrier system through one-step surface modification of the ibuprofen-impregnated silica MCM-41 with 1, 1, 1, 3, 3, 3-hexamethyldisilazane (HMDS). The 29Si MAS NMR characterization demonstrated that different contents of trimethylsilyl (TMS) groups were successfully grafted onto the samples modified with different silylation times. The results obtained from in vitro tests exhibited that the introduction of TMS groups greatly retarded the ibuprofen release rate. Even after in vitro test for 48 h, only 75% of the impregnated ibuprofen could be released from the modified sample with TMS groups content of 14.5% (related to the total silicon atoms). However, the release of ibuprofen could be completed just after about 1 h from the pure silica MCM-41 under the same release conditions. Furthermore, the release rate of ibuprofen could be well modulated by changing the grafted content of TMS groups, and was found to decrease with increasing grafted amount of TMS groups.

Biological Availability↗

Element selective detection for supercritical-fluid chromatography.

This manuscript describes the use of Supercritical-Fluid Chromatography (SFC) with plasma spectrometric detection for the analysis of organometallics. An introduction on the principles and characteristics of Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) is included, along with a discussion about requirements for coupling SFC to plasma detection and the different approaches for interfacing SFC to ICP. The last part of this review paper provides a comprehensive description of SFC-ICP applications for the analysis of organometallics containing iron, silicon, tin, chromium, arsenic, lead, mercury and antimony.

Antimony↗

Nano DCPA-whisker composites with high strength and Ca and PO(4) release.

The main challenges facing composite restorations are secondary caries and bulk fracture. The objective of this study was to develop nano DCPA (dicalcium phosphate anhydrous)-whisker composites with high strength and Ca and PO(4) ion release to combat caries. Flexural strength for the nano DCPA-whisker composites at a nano DCPA:whisker mass ratio of 1:2 ranged from (148 +/- 9) MPa to (167 +/- 23) MPa, significantly higher than the (103 +/- 32) MPa of an inlay/onlay commercial control composite without Ca-PO(4) release. The nano DCPA-whisker composite released PO(4) to a concentration of (1.95 +/- 0.13) mmol/L and Ca of (0.68 +/- 0.05) mmol/L. Compared with previous conventional Ca- and PO(4)-releasing composites, the nano DCPA-whisker composites had strengths two-fold higher, and released comparable or higher levels of Ca and PO(4). In conclusion, combining nano-DCPA with whiskers yielded novel composites that released high levels of Ca and PO(4) requisite for remineralization. These high-strength composites may provide a unique combination of stress-bearing and caries-inhibiting capabilities.

Analysis of Variance↗

Micro-morphometric assessment of titanium plasma-sprayed coating removal using burs for the treatment of peri-implant disease.

This study evaluated, in vitro, the effectiveness of diamond and carbide burs, and bur sequences to remove the plasma-sprayed titanium coating from IMZ fixture surfaces. Fifteen polishing procedures were tested. They included the use of 12, 16, 30 bladed carbide burs or bevered carbide burs and 30, 15, 8 microns mean-particles-size diamond burs. The treated surfaces were evaluated with profilometer and SEM. Worn burs and titanium debris produced by the grinding were observed with SEM. All procedures produce smoother surfaces than baseline plasma-sprayed surfaces for both Ra and Rz(DIN) parameters (P < 0.001). A roughening effect of the 8 microns mean-grit diamond bur and 30 bladed burs were noted. The single carbide burs produce polished surfaces affected by waviness. Waviness was minimized by sequence or diamond bur use. The carbide bur blades were variously damaged after their use. In contrast, the grit of diamond burs was observed to be clogged by titanium debris whose amount seemed to be inversely related to the diamond mean particle size. Debris produced by diamond burs was granular whereas that produced by carbide bladed burs showed needle or flake morphology. In conclusion, the most effective titanium plasma sprayed removal were obtained by 30 microns and 15 microns mean-particle-size diamond burs, i.e. 30 microns plus 15 microns diamond burs and carbide 12 plus 16 bladed burs used in sequence.

Analysis of Variance↗

Effect of surface reaction layer on grindability of cast titanium alloys.

OBJECTIVE: The purpose of this study was to investigate the effect of the cast surface reaction layer on the grindability of titanium alloys, including free-machining titanium alloy (DT2F), and to compare the results with the grindability of two dental casting alloys (gold and Co-Cr). METHODS: All titanium specimens (pure Ti, Ti-6Al-4V and DT2F) were cast using a centrifugal casting machine in magnesia-based investment molds. Two specimen sizes were used to cast the titanium metals so that the larger castings would be the same size as the smaller gold and Co-Cr alloy specimens after removal of the surface reaction layer (alpha-case). Grindability was measured as volume loss ground from a specimen for 1 min using a handpiece engine with a SiC abrasive wheel at 0.1 kgf and four circumferential wheel speeds. RESULTS: For the titanium and gold alloys, grindability increased as the rotational speed increased. There was no statistical difference (p>0.05) in grindability for all titanium specimens either with or without the alpha-case. Of the titanium metals tested, Ti-6 Al-4V had the greatest grindability at higher speeds, followed by DT2F and CP Ti. The grindability of the gold alloy was similar to that of Ti-6 Al-4V, whereas the Co-Cr alloy had the lowest grindability. SIGNIFICANCE: The results of this study indicated that the alpha-case did not significantly affect the grindability of the titanium alloys. The free-machining titanium alloy had improved grindability compared to CP Ti.

Alloys↗

Effect of unfilled resins and a silane primer on bonding between layers of a light-activated composite resin veneering material.

This investigation evaluated the effect of unfilled resins and a silane primer on bonding between layers of a urethane-based composite resin veneering material. Shear bond strengths between the layers were determined with a two-liquid silane primer and three unfilled resin bonding agents. The silane primers and unfilled resins enhanced the bond between layers of the veneering material. Durability of the bond, however, was influenced by the composition of the bonding agent. Among the systems investigated, combined use of the silane primer with triethyleneglycol dimethacrylate-based unfilled resin exhibited durable and consistent bond strength.

Analysis of Variance↗

Experimental studies with palygorskite dusts.

As the preliminary results of experimental studies on dust from the palygorskite group have led to some confusion a detailed description of the completed investigation is given for clarification. As in other experiments the biological effects have been shown to be associated with the physical characteristics of the fibres in these specimens. Samples of sepiolite and attapulgite from Spain and a single sample of palygorskite from the United Kingdom have been studied. Serious abnormalities were produced only by the palygorskite and one of the attapulgite dusts. The palygorskite is of no commercial interest and the attapulgite was from one small deposit and was used only in the preparation of drilling mud in the exploration of oil deposits.

Administration, Inhalation↗

Postadjustment polishing of CAD-CAM ceramic with luminescence diamond gel.

PURPOSES: (1) to investigate by SEM and profilometry the effectiveness of Luminescence diamond polishing gel on machinable ceramic after adjustment grinding with different grit diamond finishing burs, and (2) to define a simple, time-saving ceramic finishing and polishing technique for clinically satisfactory results. MATERIALS AND METHODS: Discs, 3 mm thick, were cut from Vita Mark II CAD-CAM ceramic and ground to a uniform surface finish on 600 grit wet SiC paper. Five specimens in each of the seven groups below were finished unidirectionally by a sweeping mode with the following Two Striper MFS diamond burs: 1. MF1 (45 microm); 2. MF2 (25 microm); 3. MF3 (10 microm); 4. MF1 + MF2; 5. MF1 + MF3; 6. MF2 + MF3; 7. MF1 + MF2 + MF3. Then, Luminescence diamond polishing gel was dispensed on a mandrel-mounted felt applicator and applied at 10,000 rpm for 60 s, and after dipping in water for another 60-s sequence. Surface roughness was determined for each step with a stylus-fitted surface analyzer. On each specimen five parallel tracings (evaluation length 4.0 mm and cut-off length 0.8 mm) were made 1 mm apart. Ra and Rz values were recorded as roughness parameters. Data was subjected to one-way ANOVA and Tukey's multiple comparison test at a significance level of alpha = 0.05. One additional sample for each grinding and polishing step in each of the seven groups was produced for SEM analysis. RESULTS: Diamond polishing after MF1 finishing reduced Ra and Rz significantly from 1.75 to 0.79, and from 10.0 to 4.09 microm, respectively, whereas the Ra and Rz reduction after MF3 finishing and diamond polishing were from 0.64 to 0.49 and from 4.31 to 1.81 microm. The polished surface roughness of specimens prefinished with MF2 or MF3 burs alone or as the final step after preceding grinding with coarser grits was not significantly different. The average Ra and Rz values were 0.42 microm and 1.73 microm. SEM photographs confirmed the uniformity of the surface finish in these groups. The second polishing sequence did not significantly improve the smoothness obtained with the first cycle.

Analysis of Variance↗

The bone-metal interface of defect and press-fit ingrowth of microwave plasma-chemical vapor deposition implants in the rabbit model.

PURPOSE: The histological differences between the defect and contact areas of the implant surface to bone were tested in 35 New Zealand White rabbits in a standardized model. Microwave plasma chemical vapor-coated implant probes were tested in control and uncoated materials. MATERIAL AND METHODS: In each femur of 35 rabbits, cylindrical implant rods with a planed side were inserted. Three groups, divided in coated and uncoated material at half, were observed 42, 84 and 168 days. The probes were examined histologically for bone-implant contact in the curved and plane (defect area) sides. RESULTS: Generally the bone-implant contact seems to be nearly constant in time in the curved area of coated and uncoated probes. Here the implant was inserted in the press-fit mode. Diamond-coated probes showed similar bone-implant contact (51.9% (42 days), 62.5% (84 days), 56.1% (168 days)) compared to uncoated material (56.2%, 65.4%, 62.9%). The defect area (plane side) had no bone-implant contact at the time of insertion and showed increasing values on longer observation times with only significant differences in the 42-day group between coated (17.85%, 35.2%, 47.7%) and uncoated materials (35.5%, 40.55%, 51.81%). CONCLUSION: The evaluation of the curved side of the implant probe showed no great variation of bone-implant contact within the described observation times. This model simulates the usual implant insertion situation. The diamond-coated material becomes osseointegrated at a later time point. The bone-implant contact was only statistically relevant in one group in comparison to uncoated material.

Alloys↗

Bond strength of porcelain on cast vs. wrought titanium.

The bond strength of porcelain fused to cast and wrought titanium surfaces was calculated from fracture loads in a 4-point bending test. Two different porcelain were applied (O'Hara and Duceratin). The surface of Ti-cast specimens was treated in two different ways to produce variations in the impurity level before porcelain veneering. Microhardness measurements as well as scanning electron microscopy with EDX analysis were conducted. The results showed no significant difference in bond strength between the two porcelains. Nor was any difference in bond capacity found between thoroughly blasted castings and wrought titanium. Significantly lower bond strengths were observed for lightly blasted specimens and for specimens treated with Gold bonding agent. Impurities in the surface region of the castings were found to be due to contact with the investment during solidification. This indicates that a thin surface layer (50-100 microns) of the casting should be removed before firing of the porcelain.

Aluminum Oxide↗

Influence of adhesive systems on interfacial dentin gap formation in vitro.

PURPOSE: This study measured: 1) the interfacial dentin gap formation (IGW) of 2 etch & rinse and 3 self-etch systems with different degrees of acidity and determined the correlation between the smear layer thickness and interfacial gap formation after 1 day and 6 months water storage; 2) the hybrid layer thickness (HLT) produced by the adhesives applied under different smear layer thicknesses. METHODS AND MATERIALS: Three self-etch adhesives, a mild (Clearfil SE Bond; SE), a moderate (Optibond Solo Plus Self-Etch Primer; SO) and a strong (Tyrian Self Priming Etchant + One Step Plus; TY), and 2 etch & rinse systems (Single Bond; SB and Scotchbond Multi-Purpose Plus; SBMP) were studied. After flat grinding of the occlusal surfaces, 30 molars were sectioned longitudinally in 2 halves. Dentin surfaces with thick and thin smear layers were obtained for each tooth after polishing different sections on 60- and 600-grit SiC paper, respectively. A resin composite (Z250) build-up was made on each tooth section after randomized application of the adhesives. After 24-hour storage in water, resin-dentin bonded sticks (0.8 mm2) were prepared and divided for 1-day and 6-month measurements. The IGW was measured in a stereomicroscope under 400x. SEM micrographs were also made in order to measure the HLT provided by each adhesive. RESULTS: The thickness of the smear layer did not influence the mean gap width (p>0.05). The etch & rinse systems showed the lowest mean IGW in the 1-day group. Their IGW remained unchanged after 6 months. The self-etch systems showed wider initial IGW, which diminished after 6 months water storage, to sizes similar to the etch & rinse systems. The hybrid layer was thicker when bonded to #60 SiC-treated dentin; however, this difference was only statistically different for the 3-step etch & rinse system (p=0.001). The thickest hybrid layers were observed for the 2 etch & rinse adhesive systems and the thinnest for the mild self-etch. A negative and strong correlation between IGW and HLT was observed for the self-etching adhesive systems tested (r=80.2, p=0.01).

Bisphenol A-Glycidyl Methacrylate↗

The art and science of abrasive finishing and polishing in restorative dentistry.

Effective use of rotary cutting burs and bonded, coated, and loose abrasives can greatly simplify and improve the effectiveness of finishing and polishing procedures. Fluted carbide finishing burs appear to be the optimal rotary contouring devices for posterior composite resins. Finishing diamonds are preferred for gross finishing of adjusted porcelain. Coated abrasive discs and strips provide unique interproximal and incisal access and are preferred for finishing and polishing of microfil resins. Rubberized bonded abrasives have evolved to provide a greater range of finishing and polishing action on composite resin and for polishing porcelain. A wide selection of aluminum oxide and diamond polishing pastes, together with highly effective felt and foam application devices, are now available to polish composite and porcelain to an enamel-like appearance. Aluminum oxide composite polishing pastes are highly effective and strongly recommended for use on highly filled hybrid composites but have limited utility on microfil resins, with use of extrafine (0.3-mu) pastes clearly contraindicated.

Aluminum Oxide↗

An evaluation of polishing agents for composite resins.

After the gross reduction and fine finishing of a composite resin restoration, selecting a system to create the smoothest polish is difficult because high magnification is necessary to compare the surface roughness. The surfaces of four anterior and posterior composite resins were compared using a Mylar strip, an unfilled resin as a glaze, polishing with three rubber polishers, and three different manufacturers' series of disks. This study suggested that pairing a specific composite resin with a matching polishing system produced the smoothest surface. Because of the differences in the size, shape, number of filler particles, and the type of resin, one system was incapable of creating the smoothest surface for all composite resins.

Acrylic Resins↗