PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Solid-phase microextraction and gas chromatography-mass spectrometry for the rapid screening of triazole residues in wine and strawberries.

A solid-phase microextraction gas chromatography-mass spectrometry method has been developed for the determination of triazole residues, such as triadimefon, propiconazole, myclobutanil and penconazole. The method has been successfully applied to the analysis of strawberries and wine samples. The procedure is solvent-free, simple and highly sensitive. Within-day and day-to-day RSDs ranged between 2-11% and 7-28%, respectively. Detection limits estimated at a signal-to-noise ratio of 3 ranged between 30 (propiconazole) and 100 ng/kg (triadimefon). Since the detection limits achieved by this method are well below the maximum residue levels for wine (or grapes) and strawberries recommended by the European legislation, it can be conveniently used as a low-cost rapid screening method for the contamination of the considered samples.

Fragaria↗

Solid-phase microextraction coupled with gas chromatography-ion trap mass spectrometry for the analysis of haloacetic acids in water.

Headspace solid-phase microextraction (SPME) was studied as a possible alternative to liquid-liquid extraction for the analysis of haloacetic acids (HAAs) in water. The method involves derivatization of the acids to their ethyl esters using sulphuric acid and ethanol after evaporation, followed by headspace SPME with a polydimethylsiloxane fibre and gas chromatography-ion trap mass spectrometry (GC-IT-MS). The derivatization procedure was optimized: maximum sensitivity was obtained with esterification for 10 min at 50 degrees C in 30 microl of sulphuric acid and 40 microl of ethanol. The headspace SPME conditions were also optimized and good sensitivity was obtained at a sampling temperature of 25 degrees C, an absorption time of 10 min, the addition of 0.1 g of anhydrous sodium sulfate and a desorption time of 2 min. Good precision (RSD lower than 10%) and detection limits in the ng l(-1) range (from 10 to 200 ng l(-1)) were obtained for all the compounds. The optimized procedure was applied to the analysis of HAAs in tap water and the results obtained by standard addition agreed with those of EPA method 552.2, whereas discrepancies due to matrix interferences were observed using external calibration. Consequently, headspace SPME-GC-IT-MS with standard addition is recommended for the analysis of these compounds in drinking water.

Acetates↗

Development of a headspace solid-phase microextraction procedure for the determination of free volatile fatty acids in waste waters.

An analytical procedure based on headspace solid-phase microextraction (SPME) coupled to GC-flame ionization detection/Negative Chemical Ionization Mass Spectrometry has been developed for the determination of free volatile fatty acids (C2-C7) in waste water samples. Five different coatings have been evaluated and polydimethylsiloxane-Carboxen was the only fiber that allows a successful extraction of the shortest chain fatty acids (acetic and propionic). Several parameters such as extraction time and temperature, desorption conditions, agitation speed and sample volume have been optimized using the polydimethylsiloxane-Carboxen fiber. The linear dynamic range was over two-four orders of magnitude, depending on the acid. Procedural detection limits were in the low to medium microg/l levels and the RSDs were between 5.6% and 13.3%. To evaluate the applicability of the developed SPME procedure on real samples, fermented urban wastewaters were analysed.

Chromatography, Gas↗

Automated in-tube solid-phase microextraction coupled with HPLC for the determination of N-nitrosamines in cell cultures.

An automated in-tube solid-phase microextraction (SPME) HPLC analysis method for 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and several metabolites has been developed. NNK is one of the tobacco-specific N-nitrosamines (TSNA), which has been linked to cancers associated with the use of or exposure to tobacco products. In-tube SPME is an on-line extraction technique in which analytes are extracted and concentrated from the sample directly into a coated capillary by repeated draw/eject steps. In this study, a tailor-made polypyrrole (PPY)-coated capillary and several commercially available capillaries (capillary GC columns) were used to evaluate their extraction efficiencies for NNK and several metabolites in cell cultures. Compared with commercial capillaries that were currently used for in-tube SPME, the PPY-coated capillary showed better extraction efficiency for all of the compounds studied. After optimization of the extraction conditions, NNK and five metabolite compounds were analyzed in spiked cell cultures, confirming the applicability of the developed method. Excellent linearity was observed for all compounds (av R2 = 0.9942) and detection limits that ranged from 20 to 250 ng/mL. The average within-day and between day variations (% RSD) were 2.9 and 3.6%, respectively. This automated extraction and analysis method simplified the determination of the TSNA, requiring a total sample analysis time of only approximately 30 min.

Animals↗

High levels of monoaromatic compounds limit the use of solid-phase microextraction of methyl tert-butyl ether and tert-butyl alcohol.

Recently, two papers reported the use of solid-phase microextraction (SPME) with poly(dimethylsiloxane)(PDMS)/Carboxen fibers to determine trace levels of methyl tert-butyl ether (MTBE) and tert-butyl alcohol (tBA) in water. Attempts were made to apply this technique to the analysis of water samples containing high levels of benzene, toluene, ethylbenzene, xylenes, and trimethylbenzenes (BTEXsTMBs) as would be expected at leaking underground storage tank sites. It was found that when the sample contained total aromatic compounds above 1 ppm, the response of the internal standards, deuterated MTBE and tBA, dropped by more than 65%. As this decrease in internal standard peak area was unacceptable, a static headspace method was used instead. This headspace method was used successfully to analyze groundwater from 670 monitoring wells at 74 service stations located in the northeast United States. In these monitoring wells, 30% of the samples contained total BTEXsTMBs above 1 ppm. If the SPME method was used to analyze these samples, dilution of more than 200 samples would be required to minimize the adverse matrix effect that high aromatic content had on the internal standard peak area.

Carcinogens↗

A headspace solid-phase microextraction method for the determination of some secondary compounds of Brazilian sugar cane spirits by gas chromatography.

A headspace solid-phase microextraction (SPME) method was developed for the determination of secondary compounds from Brazilian sugar cane spirits, or cachaça, by GC-FID. An SPME holder with an 85 microm polyacrylate coating was utilized. The novel method is compared with an optimized method: liquid-liquid extraction (LLE). Both methods showed good linearity, but the repeatability for analyses done with the SPME technique (%RSD = 1.8-3.9) was better than for those done with LLE (%RSD = 10.3-11.7). The concentrations of the analytes obtained in the analysis of 12 cachaça samples with the SPME technique were higher than those obtained with LLE. In the SPME method the extraction wastes are smaller. Cachaça samples were qualitatively analyzed for GC-MS.

Gas Chromatography-Mass Spectrometry↗

Correlations between pulp properties of eucalyptus clones and leaf volatiles using automated solid-phase microextraction.

Analysis of biogenic volatile organic compounds (BVOC) of 14 Eucalyptus clones has been performed using an automated headspace solid-phase microextraction (HS-SPME) coupled to gas chromatography (GC)/ion trap mass spectrometry (ITMS) method. Correlations between pulp properties of Eucalyptus clones and the BVOC of their leaf headspaces were studied. The compounds alpha-terpineol and the sesquiterpene beta-eudesmol were positively correlated with S5, a property related to the hemicelluose content in the pulp. Qualitative results obtained with automated HS-SPME were sufficient to group together the same species and related hybrids through cluster analysis and were confirmed through principal component analysis. A preliminary separation of the essential oils of Eucalyptus dunnii through comprehensive two-dimensional gas chromatography (GC x GC) showed approximately 580 peaks compared to approximately 60 in a typical GC/ITMS first-dimension chromatogram. The potential of HS-SPME coupled to GC x GC to improve the separation of Eucalyptus volatiles and other plant essential oils looks extremely promising for new applications of unsupervised learning methods.

Autoanalysis↗

Comparison of static headspace, headspace solid phase microextraction, headspace sorptive extraction, and direct thermal desorption techniques on chemical composition of French olive oils.

Static headspace (SHS), headspace solid phase microextraction (HS-SPME), headspace sorptive extraction (HSSE), and direct thermal desorption (DTD) were applied to the analysis of four French virgin olive oils from Corsica. More than 60 compounds were isolated and characterized by GC-RI and GC-MS. SHS was not suited to the characterization of olive oil volatile compounds because of low sensitivity. The SPME and HSSE techniques were successfully applied to olive oil headspace analysis. Both methods allow the characterization of volatile compounds (mainly C(6) aldehydes and alcohols), which contribute significantly to the "green" flavor note of virgin olive oils. The PDMS stir bar showed a higher concentration capacity than a DVB/CAR/PDMS SPME fiber due to the higher volume of polymeric coating. DTD was a very good tool for extracting volatile and especially semivolatile compounds, such as sesquiterpenes, but requires a significant investment like that for HSSE. Finally, SPME may be a more appropriate technique for routine quality control due to its operational simplicity, repeatability, and low cost.

Chromatography, Gas↗

A novel approach based on solid phase microextraction gas chromatography and mass spectrometry to the determination of highly reactive organic compounds in cells cultures: styrene oxide.

A solid phase microextraction (SPME) gas chromatography/mass spectrometry (GC/MS) method was developed to assess actual doses of highly reactive organic compounds like styrene oxide (SO) in exposed cell cultures. Using SPME, we set up a method to measure accurately extracellular SO concentrations as well as to obtain an approximate assessment of intracellular levels. The SPME-GC/MS method was developed and validated using two different coating materials, carboxen-PDMS and polyacrylate. In cell-free systems, linearity was established over 3 orders of magnitude for both fibers, but carboxen-PDMS showed higher extraction efficiency and a lower limit of detection (0.5 x 10(-7) vs 10(-6) M for polyacrylate). Precision calculated as % RSD was within 4-16% for all intra- and interday determinations. Experiments performed to study SO stability in cell-free medium showed a time-dependent decrease in SO concentration (11% of initial the concentration after 24 h), mostly due to the spontaneous hydrolysis of SO into styrene glycol, which was measured by liquid chromatography/tandem mass spectrometry (LC/MS/MS). When the neuronal cell line (SK-N-MC) was exposed to a nominal concentration of 0.3 x 10(-4) M SO, the actual concentration measured in the supernatant was considerably lower and was found to decrease during incubation. Intracellular SO was estimated indirectly, by difference between the amount measured in the medium without cells and in the supernatant of the cell-containing medium.

Acrylates↗

On-fiber derivatization for direct immersion solid-phase microextraction. Part II. Acylation of amphetamine with pentafluorobenzoyl chloride for urine analysis.

On-fiber derivatization was used for solid-phase microextraction (SPME) in order to increase the detectability and extractability of drugs in biological samples. Amphetamine, which was used as a model compound, was derivatized with pentafluorobenzoyl chloride (PFBCl) and subjected to gas chromatography with electron capture or mass spectrometric detection. Extraction was performed by direct immersion of a 100 microm polydimethylsiloxane-coated fiber into buffered human urine. On-fiber derivatization was performed either after or simultaneously with extraction. The former procedure gave cleaner chromatograms but the latter turned out to be superior with respect to linearity and repeatability. For the on-fiber derivatization of amphetamine an excess of reagent is required. Because a considerable part of the PFBCl loaded on to the fiber is used up by reaction with matrix compounds and water, a reagent loading time of 5 min was needed to obtain a linear range (r = 0.9756) from 250 pg mL(-1) to 15 ng mL(-1). Due to an interfering matrix compound, the limit of detection was also found to be dependent on the reagent loading time, i.e., the limit of detection for a PFBCl loading time of 5 min is 250 pg mL(-1) whereas that for a 1 min loading time it is 100 pg mL(-1). The relative standard deviation (n = 7) of the method was about 11% at an amphetamine concentration of 1 ng mL(-1). The applicability of the method for the determination of drugs in biological samples is shown.

Acylation↗

Potential of solid-phase microextraction fibers for the analysis of volatile organic compounds in air.

This work presents the usefulness of five different solid-phase microextraction fibers in the screening of volatile organic compound (VOC) traces in air samples. The performances of these fibers are compared by studying the sorption kinetics in an equimolar gaseous mixture of eleven VOCs. For each fiber, static and dynamic sampling are compared. It is shown that repeatability is better for the dynamic mode (less than 6% for dynamic sampling and 10% for static sampling). The equilibrium time and the sensitivity vary considerably from one fiber type to another. As an example, the classical polydimethylsiloxane (PDMS) coating presented the shortest equilibration time (5 min) but also the poorest sensitivity, whereas the PDMS-Carboxen showed the longest extraction time but the greatest sensitivity. The estimation of the quantity of VOCs fixed on the target fiber allows for the determination of the different affinities of the compounds with the involved sorbent and relates them with physicochemical properties of the molecules. Competitive sorption is observed for the fibers involved with the adsorption process (i.e., PDMS-divinylbenzene and PDMS-Carboxen fibers). These competitions can lead to SPME calibration problems and thus bad quantitative analysis.

Journal Article↗

Solid-phase microextraction for cannabinoids analysis in hair and its possible application to other drugs.

This paper describes the application of solid-phase microextraction (SPME) to cannabis testing in hair. Fifty milligrams of hair was washed with petroleum ether, hydrolyzed with NaOH, neutralized, deuterated internal standard was added and directly submitted to SPME. The SPME was analyzed by GC-MS. The limit of detection was 0.1 ng/mg for cannabinol (CBN) and delta9-tetrahydrocannabinol (THC) and 0.2 ng/mg for cannabidiol (CBD). THC was detected in a range spanning from 0.1 to 0.7 ng/mg. CBD concentrations ranged from 0.7 to 14.1 ng/mg, and CBN concentrations ranged from 0.4 to 0.7 ng/mg. The effectiveness of different decontamination procedures was also studied on passively contaminated hair. The proposed method is also suitable for the analysis of methadone in hair; cocaine and cocaethylene can be detected in hair with SPME extraction after enzymatic hydrolysis.

Cannabinoids↗

Fully automated determination of cannabinoids in hair samples using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

This paper describes a fully automated procedure using alkaline hydrolysis and headspace solid-phase microextraction (HS-SPME) followed by on-fiber derivatization and gas chromatographic-mass spectrometric (GC-MS) detection of cannabinoids in human hair samples. Ten milligrams of hair was washed with deionized water, petroleum ether, and dichloromethane. After the addition of deuterated internal standards the sample was hydrolyzed with sodium hydroxide and directly submitted to HS-SPME. After absorption of analytes for an on-fiber derivatization procedure the fiber was directly placed into the headspace of a second vial containing N-methyl-N-trimethylsilyltrifluoroacetamide (MSTFA) before GC-MS analysis. The limit of detection was 0.05 ng/mg for delta9-tetrahydrocannabinol (THC), 0.08 ng/mg for cannabidiol (CBD), and 0.14 ng/mg for cannabinol (CBN). Absolute recoveries were in the range between 0.3 and 7.5%. Linearity was proved over a range from 0.1 to 20 ng/mg with coefficients of correlation from 0.998 to 0.999. Validation of the whole procedure revealed excellent results. In comparison with conventional methods of hair analysis this automated HS-SPME-GC-MS procedure is substantially faster. It is easy to perform without use of solvents and with minimal sample quantities, but with the same degree of sensitivity and reproducibility. The applicability was demonstrated by the analysis of 25 hair samples from several forensic cases. The following concentration ranges were determined: THC 0.29-2.20 (mean 1.7) ng/mg, CBN 0.55-4.54 (mean 1.2) ng/mg, and CBD 0.53-18.36 (mean 1.3) ng/mg. 11-nor-Delta9-tetrahydrocannabinol-9-carboxylic acid could not be detected with this method.

Cannabinoids↗

Determination of Se4+ in drinkable water by solid-phase microextraction and gas chromatography/mass spectrometry.

A method was developed for the selective determination of Se4+ in drinkable water by solid-phase microextraction (SPME) and gas chromatography/mass spectrometry (GC/MS). Se4+ was selectively derivatized to ethane, 1,1'-selenobis by reaction with sodium tetraethylborate, extracted by the SPME fiber, and determined by GC/MS. Both headspace (HS)-SPME and direct SPME were studied. The method requires only a few milliliters of sample and 20 min for completion. At 2.0 microg/L concentration, the relative standard deviation was 10.1% for HS-SPME and 9.1% for direct SPME. For HS-SPME, the theoretical detection limit was 81 ng/L and 166 ng/L for direct SPME. The recovery rate was 95%. The method was used to determine Se4+ in 10 tap water samples.

Calibration↗

Optimization of solid-phase microextraction (SPME) for the recovery of explosives from aqueous and post-explosion debris followed by gas and liquid chromatographic analysis

Solid-phase microextraction (SPME) has been evaluated for the recovery of explosives residues from aqueous samples and real post-explosion solid debris samples and optimized using gas chromatography with an electron capture detector (GC-ECD) and high-performance liquid chromatography with ultraviolet detection (HPLC-UV). A modified SPME/HPLC interface utilizing dual six-port valves allowed for independent optimization of SPME desorption and injection variables that provided improved chromatographic resolution and sensitivity. A unique combination of cyano and octadecyl columns resulted in the complete separation of the 14 explosives in EPA method 8330 mixture using HPLC with good quantitative results. At the optimum SPME conditions, the limits of detection (LOD) were found to be of 5 ng/mL to 16 ng/mL of explosives in water and 10 microg/kg to 40 microg/kg of explosives from soil. The technique has been successfully applied to the analysis of real post-explosion debris and can be adapted for use in the field utilizing portable chromatographic instruments.

Journal Article↗

Determination of cocaine and cocaethylene in plasma by solid-phase microextraction and gas chromatography-mass spectrometry.

The present paper describes a method for the simultaneous determination of cocaine and cocaethylene in plasma. It was based in the extraction of the analytes by solid-phase microextraction (SPME), and gas chromatography-mass spectrometry (GC-MS) was used to identify and quantify the analytes in selected ion monitoring (SIM) mode. The method showed to be very simple, rapid and sensitive. The method was validated for the two compounds, including linearity (range 25-1000 ng/mL) and the main precision parameters. It was applied to ten plasma samples from cocaine and alcohol users, obtaining positive results in all cases.

Cocaine↗

Use of solid-phase microextraction to detect and quantify gas-phase dicarbonyls in indoor environments.

Solid-phase microextraction (SPME) was evaluated for the detection and quantification of the gas-phase dicarbonyls, glyoxal (GLY) and methylglyoxal (MGLY). Additionally, polydimethylsiloxane (PDMS), polydimethylsiloxane/divinylbenzene (PDMS/DVB), and carbowax/divinylbenzene (CW/DVB) fibers were tested to determine the optimum fiber for detection of these species. GLY and MGLY were derivatized with O-(2,3,4,5,6-pentafluorobenzyl)-hydroxylamine hydrochloride (PFBHA), extracted with SPME from headspace or bag chamber and then analyzed by GC/MS. The PDMS/DVB SPME fiber for on-fiber derivatization and subsequent sampling for gas-phase methylglyoxal provided the optimum combination of analytical reproducibility and sensitivity. Linearity of the calibration curve was achieved across a range of 11-222 microg/m(3) (4-75 ppb).

Air Pollutants↗

Comparison of solid-phase extraction and solid-phase microextraction for carbofuran in water analyzed by high-performance liquid chromatography-photodiode-array detection.

In this study a direct solid-phase microextraction (SPME) procedure has been developed for the determination of carbofuran in water. Experimental parameters such as selection of SPME coating, effect of temperature, effect of salt addition and solvent desorption were studied and optimized. Analytical parameters such as linearity, precision, detection and quantitation limits, and matrix effects for solid-phase extraction (SPE) and SPME methods were evaluated for comparison purposes with the aim of selecting the most appropriate depending on the detection capabilities required. SPE and SPME were followed by high-performance liquid chromatography with diode-array detection, using a 50 x 4.6 mm I.D. guard column and a 150 x 4.6 mm I.D. analytical column, both packed with C18 silica. Both methods can be applied to real samples and give the same results, but SPE allows the detection of lower carbofuran concentrations (0.06 microg/L) as compared to

Carbofuran↗