PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Vacuum Extraction, Obstetrical”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

[Standard versus "hand-pump" vacuum extraction device].

OBJECTIVE: Clinical evaluation of a standard vacuum delivery device and "hand-pump" vacuum delivery device. DESIGN: Retrospective clinical study. SETTING: Department of Obstetrics and Gynecology, City Hospital, Litomĕrice. METHODS: In the period between January 1993 and the end of December 2003 there were 81 deliveries by vacuum at our department, 55 of which (67.90%) were with standard vacuum delivery device and 26 (32.10%) with "hand-pump" vacuum delivery device. We evaluated the differences in the following parameters: 1. basic characteristics--maternal age, parity, gestational age, birth weight and type of labor, 2. early maternal morbidity--the presence of episiotomy, perineal and vaginal tears, blood loss, the need of blood transfusion, duration of hospitalization and postpartum incontinentia urinae and alvi, 3. early neonatal morbidity--pH a. umbilicalis, Apgar score and the presence of newborn's trauma. The differences found in individual groups were then used for statistics and evaluated. RESULTS: In comparison with standard vacuum delivery device the usage of "hand-pump" vacuum delivery device appears to be more convenient for its significantly higher reliability, especially due to construction and also for its favourable features at early neonatal morbidity. CONCLUSION: We have proved that the "hand-pump" vacuum delivery device is in comparison with standard vacuum delivery device more favourable with newborns and more convenient to use for its high reliability.

Female↗

Conduct of labor and rupture of the sphincter ani.

OBJECTIVE: To determine whether the conduct of the second stage of labor and delivery technique influences the incidence of rupture of the anal sphincter. MATERIAL AND METHOD: A total of 1072 primipara delivered vaginally at term at Rigshospitalet in 1998. A questionnaire on prenatal risk factors, conduct of the second stage of labor, and delivery technique was completed by the attending midwife immediately after delivery in 90 cases with rupture of the sphincter and in two subsequent controls (n = 164), matched by use of vacuum extractor and episiotomy. RESULTS: Partial or total sphincter rupture was found in 8.4% of primipara who delivered vaginally, in 20.9% of those delivered by vacuum extraction, and in 6.4% of those with episiotomy only. The prenatal risk factors--maternal age, birth weight, shoulder dystocia, and edema of the perineum were found to have a statistically significant effect on the incidence of rupture of the sphincter ani. In non-instrumental vaginal deliveries easing of the perineum over the caput as it advanced helped prevent a rupture of the anal sphincter. Vacuum extraction performed with the woman in a semi-recumbant position was associated with an increased risk of rupture of the anal sphincter, whereas attention to the perineum during extraction decreased the risk. CONCLUSIONS: The significant effect of prenatal risk factors did not explain a correlation between delivery technique and rupture of the sphincter ani. The present study indicates that a reduction in the incidence of sphincter rupture may be accomplished by improved obstetric care: fewer vacuum extractions and improved delivery technique.

Adolescent↗

Brachial plexus injuries in babies born in hospital: an appraisal of risk factors in a developing country.

The present study was undertaken to evaluate the magnitude of risk factors associated with brachial plexus in infants born in hospital in Benghazi. A total of 7829 babies were examined over a period of 6 months. Twenty-eight had brachial palsy, giving an incidence of 3.6 per 1000 livebirths. Significant (P less than 0.001) perinatal risk factors observed were maternal parity greater than or equal to 6, maternal diabetes, instrumental deliveries, shoulder dystocia and foetal macrosomia. Other risk factors observed included breech extraction, postmaturity and prematurity (P less than 0.02). Complete brachial plexus injury was seen in 12 cases and six infants had residual handicap on follow-up at 18-24 months.

Adult↗

Vacuum extraction: is there any need to improve the current training in the UK?

OBJECTIVE: The objective of this study was to assess the use and efficacy of delivery by vacuum extraction or ventouse in routine clinical practice and to assess some aspects of the procedure that may reflect the quality of training in this technique. MATERIALS AND METHODS: Women's demographic profiles and delivery details were collected in both the prospective (B) and retrospective (A) arm of the study. In addition, in the prospective arm of the study two custom-designed forms were used: the obstetrician recorded their perception of where the vacuum cup had been placed on one form while on a second form the pediatrician indicated the actual site of the cup placement as observed from the position of the chignon. All the diagrams of cup placement were reviewed by one of the authors, who was blinded to the outcome of the procedure. RESULTS: The vacuum extractor was the first instrument to be used in 79% and 87% of the instrumental deliveries in groups A and B, respectively, with corresponding failure rates of 20% and 21%. Although an occipito-posterior position was diagnosed in 11% of cases of group A and 14% of cases of group B, the specifically designed occipito-posterior cup was not used at all. The vacuum cup was considered to have been applied suboptimally in 40% of the cases where attempted vacuum delivery failed. CONCLUSION: The high rate of inappropriate positioning of the cup may reflect difficulty in accurately applying the cup, perhaps due to caput or malposition, but may also represent poor assessment of the orientation and position of the fetal skull and therefore be indicative of a need for improvement in training methods.

Clinical Competence↗

The incidence of acute neonatal respiratory disorders in relation to mode of delivery.

Over a 3-year period all infants (n = 7401) born at the Department of Obstetrics and Gynecology, Central Hospital, Borås Sweden, were studied for signs of respiratory disease. For all infants who developed signs of respiratory disorders the mode of delivery and the type of anesthesia used in cesarean section (CS) were analysed. The incidence of respiratory disorders in the whole material was 3.0% (n = 220) and the mortality rate for these disorders was 0.24%. There was a significantly higher incidence (p less than 0.001) of respiratory disorders in infants weighing greater than or equal to 2500 g born by CS vis-à-vis infants born by the vaginal route. The group born by elective CS under maternal general anesthesia had a higher (p less than 0.05) rate of respiratory disorders than those born by elective CS under maternal epidural anesthesia. It is concluded that the risk of respiratory disorders in infants delivered by CS is related to the mode of delivery per se. Consequently, a reduction in the proportion of such interventions ought to reduce the overall number of infants developing respiratory disease, as indicated in the present study.

Anesthesia, Obstetrical↗

Premature rupture of the membranes (PROM) at term in nulliparous women with a ripe cervix. A randomized trial of 12 or 24 hours of expectant management.

OBJECTIVE: To compare maternal and neonatal outcomes after 12 or 24 hours of expectant management in healthy nulliparous women with a ripe cervix and PROM at term. DESIGN: A prospective, randomized study. LOCATION: Karolinska Hospital, Stockholm, Sweden. SUBJECTS: Two hundred and five healthy nulliparous women with singleton pregnancies, cephalic presentation, gestational duration 36 to 42 weeks, randomized to 12 or 24 hours of expectant management after evaluation of the cervical score (> 5). If spontaneous labor did not occur, induction was performed with oxytocin after 12 or 24 hours, respectively. MAIN PARAMETERS: Maternal early morbidity and neonatal infections, obstetric intervention rate (cesarean section or instrumental delivery). RESULTS: The cesarean section rate was 4% in each group. The vacuum extraction rate was 21% in each group. Induction of labor was performed in 47% of the women allocated to 12 hours of expectant management vs 17% of the women allocated to 24 hours of expectant management (p < 0.05). The maternal morbidity rate was almost negligible. Only a few fetal infections occurred and no difference was noted between the groups. CONCLUSIONS: In healthy nulliparous women at term with a ripe cervix, expectant management over 24 hours vs 12 hours resulted in fewer inductions of labor and no increase in instrumental deliveries, without any increase in neonatal or maternal morbidity.

Adult↗

Sequential use of instruments at operative vaginal delivery: is it safe?

OBJECTIVE: Our purpose was to examine maternal and neonatal outcomes in a cohort of women who underwent delivery with the sequential use of instruments. STUDY DESIGN: This retrospective case-control study included deliveries from May 1996 through March 1998. Charts of women who underwent delivery with the sequential use of instruments (vacuum first, then forceps, or vice versa) were identified. Two control groups (1 forceps group, 1 vacuum group) were randomly selected and matched for each case. Maternal and neonatal outcomes were abstracted and compared. RESULTS: There were 34 patients in each group. There were no significant demographic differences. The vacuum group had lower rates of episiotomy (P =.01) and deep perineal lacerations (P =.014), whereas these outcomes were similar in the sequential and forceps groups. All other maternal outcomes were equivalent. There were no differences in any neonatal parameter except for superficial scalp trauma, which was more common in the vacuum group (P =.002). CONCLUSION: We conclude that the prudent use of sequential instruments at operative vaginal delivery did not engender higher rates of maternal or neonatal morbidity.

Adult↗

[Amniotic fluid embolism with coagulation disorder--a case report (author's transl)].

A case of amniotic fluid embolism during the delivery of a twin pregnancy is reported. After immediate resuscitation with artificial ventilation the mother and the neonates survived the acute episode. As a result of hyperfibrinolysis with premature separation of the placenta a dramatic postpartum haemorrhage occurred, which could be controlled by Fritsch' manoeuvre. Meanwhile it was possible to restore the coagulation disorder with fresh whole blood, fibrinogen and an antifibrinolytic agent (Aprotinin).

Aprotinin↗

Factors that are associated with clinically overt postpartum urinary retention after vaginal delivery.

OBJECTIVE: This study was undertaken to determine the incidence of clinically overt postpartum urinary retention after vaginal delivery and to examine what maternal, fetal, and obstetric factors are associated with this problem. STUDY DESIGN: This was a retrospective case-controlled study of women who had overt postpartum urinary retention after vaginal delivery from August 1992 through April 2000. RESULTS: Fifty-one of 11,332 (0.45%) vaginal deliveries were complicated by clinically overt postpartum urinary retention. In most cases (80.4%), the problem had resolved before hospital dismissal. Persons with urinary retention were more likely than control subjects to be primiparous (66.7% vs 40.0%; P <.001), to have had an instrument-assisted delivery (47.1% vs 12.4%; P <.001), to have received regional analgesia (98.0% vs 68.8%; P <.001), and to have had a mediolateral episiotomy (39.2% vs 12.5%; P <.001). On multivariate logistic regression analysis, of these 4 variables, only instrument-assisted delivery and regional analgesia were significant independent risk factors. CONCLUSION: Clinically overt postpartum urinary retention complicates approximately 1 in 200 vaginal deliveries, with most resolving before hospital dismissal. Factors that are independently associated with its occurrence include instrument-assisted delivery and regional analgesia.

Adult↗

Decision to delivery intervals for assisted vaginal vertex delivery.

OBJECTIVE: To describe the time interval between decision for assisted vaginal delivery and the birth of the baby in different clinical circumstances. DESIGN: A prospective analysis of 225 consecutive women with a singleton fetal cephalic presentation in the second stage of labour requiring an operative vaginal delivery for various reasons. SETTING: A maternity unit in a district general hospital delivering more than 6,000 women annually. MAIN OUTCOME MEASURES: The decision to delivery interval and the immediate and short term maternal and neonatal outcomes according to indication for operative vaginal delivery. RESULTS: The mean (SD) decision to delivery interval was 34.4 minutes (28.3) with a range of 5 to 101 minutes. For those delivered because of suspected fetal distress, the interval of 26.5 minutes (14.0) was significantly shorter than for those performed without fetal distress 39.5 minutes (19.0) (P < 0.0001); for cases with fetal distress, forceps were significantly quicker at 23.3 minutes (14.3) than the ventouse 29.2 minutes (13.2) (P = 0.04). The longer the interval in cases of fetal distress the less favourable the condition of the neonate at birth, although this trend did not reach statistical significance and was not seen for deliveries expedited for other reasons. Perineal repair was required following 96% forceps deliveries compared with 87% ventouse (P = 0.015). Perineal trauma was not influenced by the interval between decision and delivery. CONCLUSIONS: If speed of delivery is important, use of forceps results in a quicker birth than use of the ventouse, without any compromise to the condition of the baby at delivery, and with similar rates of perineal trauma.

Adult↗

Randomised clinical trial to assess anal sphincter function following forceps or vacuum assisted vaginal delivery.

OBJECTIVE: To compare, in a prospective, randomised controlled trial, differences in anal sphincter function following forceps or vacuum assisted vaginal delivery in an institution practising standardised management of labour. DESIGN: Prospective, randomised controlled trial. SETTING: Tertiary-referral maternity teaching hospital. POPULATION: One hundred and thirty women. METHODS: Primiparous women were recruited antenatally and if an instrumental delivery was indicated, were randomised to either a vacuum or low-cavity, non-rotational forceps assisted delivery. Follow up consisted of a symptom questionnaire, anal manometry and endoanal ultrasound at three months postpartum. MAIN OUTCOME MEASURES: Faecal continence scores, anal manometry, endoanal ultrasound. RESULTS: Sixty-one women delivered with forceps assistance (40 for failure to progress in the second stage) and 69 with vacuum assistance (33 for failure to progress); 16/69 vacuum deliveries proceeded to a forceps assisted delivery (23%). There were no statistical differences in the antecedent antenatal factors between the two groups. A third degree perineal tear followed 10 (16%) forceps and 5 (7%) vacuum deliveries. Based on intention-to-treat analysis, 36 (59%) women complained of altered faecal continence after forceps delivery compared with 23 (33%) following vacuum delivery three months postpartum (RR 2.88, 95% CI 1.41-5.88). Endoanal ultrasound was reported as abnormal following 34 (56%) forceps deliveries and 34 (49%) vacuum deliveries (RR 1.3, 95% CI 0.65-258). After exclusion of 'failed vacuum', median anal canal resting pressure was significantly lower following forceps delivery compared with vacuum delivery alone (P = 0.004). There were no significant differences in degree of ultrasound abnormality between the two groups. CONCLUSIONS: Symptoms of altered faecal continence are significantly more common following forceps assisted vaginal delivery. Based on continence outcome, when circumstances allow, vacuum should be the instrument of first choice in assisted delivery.

Adult↗

[Experiences with centralized care for pregnant diabetic women--results of the 1976 treatment period].

73 diabetic pregnant were controled and treated in our clinic 1976, there was a perinatale mortality of 2,7%. The great part of EPH--gestosis and infections of the urinary system and more operative deliveries show of a higher risk already in the stage of latent diabetes. By screening methodes for diabetics during pregnancy and by intensive control in the first trimester it will be possible to obtain better results in the future.

Dexamethasone↗