PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “nodulation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 451 records · Page 25Linked to original sources

Thyroid cancer in the thyroid nodules evaluated by ultrasonography and fine-needle aspiration cytology.

Thyroid nodule is common disorder in endocrine clinics. In Taiwan, thyroid ultrasonography with fine-needle aspiration cytology (FNAC) is the first-line examination procedure. Data in large series on the incidence of thyroid malignancy presenting with thyroid nodules are lacking in this area. To determine the incidence of malignancy in thyroid nodules and compare the results with other populations, this investigation retrospectively reviewed 21,748 subjects who were examined in one medical center from January 1986 to December 1999. All patients underwent thyroid ultrasonography studies using a real-time ultrasonographic machine and a 10-MHz transducer. Fine-needle aspirations were made in the suspected thyroid nodule and stained using the Romanowsky- based method developed by Liu. By the end of 2002, some 3629 patients (16.7%) had thyroid nodules after surgical treatment. This group comprised 3011 women with a mean age of 41.5 +/- 13.9 years, and 618 men with a mean age of 45.7 +/- 14.9 years. Of patients undergoing surgical treatment, 2761 (76.1%) patients were diagnosed with benign nodules, 858 (23.6%) with malignant nodules, and 10 (0.3%) with atypical adenoma (7 follicular and 3 Hürthle cells). The percentages of thyroid malignancy in each age group revealed two peaks in both genders, namely in patients aged 20 to 29 years and in elderly patients (aged over 65 years). The peak age for thyroid malignancy in both genders was 41 to 60 years (male) and 21 to 40 years (female). The highest ratio of malignancy occurred in the elderly group (37.2%) receiving surgical treatment. In young patients (below 19 years) the percentage of malignancy was no greater than for the whole age group (20.2% versus 25.6%). Anaplastic and metastatic cancers affecting the thyroid were the main subjects in the age group. The present results demonstrated a younger distribution for well-differentiated thyroid cancer, particularly papillary thyroid carcinoma, compared to previous studies. This outcome may have resulted from the routine application of ultrasonography with FNAC in assessing the thyroid nodules, possibly helping to achieve more timely detection. The incidence of thyroid malignancy in young patients was no higher than in adults. Early detection of thyroid malignancy may be the main reason for this phenomenon. Male subjects with thyroid nodules displayed a higher incidence of this malignancy than females. Aging subjects with thyroid nodules suffered a higher rate of malignancy and were poorly differentiated. In conclusion, this retrospective large-series study demonstrated that 3.9% (858/21,748 cases) of patients with thyroid nodules showed histopathologically proven malignancy. Thyroid cancer detected by ultrasonography with FNAC occurred an average of 10 years younger than in prior studies.

Adenocarcinoma, Follicular↗

Low-energy interstitial laser photocoagulation for treatment of nonfunctioning thyroid nodules: therapeutic outcome in relation to pretreatment and treatment parameters.

OBJECTIVE: Interstitial laser photocoagulation (ILP) is a recently proposed therapeutic procedure for the ablation of benign thyroid nodules, which has already proven to be safe and effective. However, results supporting the routine use of ILP are still limited. DESIGN: The aim of the study was to evaluate the efficacy and safety of ILP treatment in benign nonfunctioning thyroid nodules and to establish whether the therapeutic outcome may be predicted by any clinical parameter at baseline. Twenty-three patients with either a solitary nodule or a dominant nodule within a multinodular goiter underwent ILP and were evaluated 1 and 3 months later. In order to assess the efficacy of low-energy ILP, the procedure was performed with an output power of 3 W, delivering a mean energy of 33.4 +/- 12.7 Joule/mL of nodule volume, which is much lower than previously reported. MAIN OUTCOME: Nodule volume significantly decreased after ILP as assessed after 1 and 3 months (analysis of variance; F = 5.37; p = 0.007). Patients with multinodular goiter showed a greater reduction at 3 months compared with patients bearing a solitary thyroid nodule (38.6 +/- 5.3 vs. 30.9 +/- 6.5%; p < 0.01). Age, sex, ultrasound pattern (isoechogenous/hypoechogenous), pretreatment volume, number of ILP treatments, and total energy delivered did not show any significant correlation with treatment outcome. CONCLUSIONS: Our results demonstrate that ILP can produce a significant reduction of thyroid nodule volume even when a much lower energy than previously reported is delivered. ILP constitutes a minimally invasive technique, which can be carried out on an outpatient basis and could represent a valid nonsurgical alternative for thyroid nodule management. Dominant nodules within a multinodular goiter appear to be more responsive to ILP compared with solitary thyroid nodules.

Adult↗

The predictive value of ultrasound findings in the management of thyroid nodules.

BACKGROUND: Thyroid nodules are a common medical problem, but whether fine-needle aspiration cytology (FNAC) is mandated for smaller non-palpable nodules, is controversial. AIM: To evaluate whether ultrasonographic features of thyroid nodules are associated with histological malignancy, and to identify useful criteria for clinical decision-making. DESIGN: Prospective observational study. METHODS: From January 1991 to September 2004, 5198 patients were referred to our hospital for ultrasound evaluation of thyroid nodules. Overall, 7455 nodules (diameters from 6 to 100 mm) were examined; 2865 (38.4%) were <10 mm in diameter. All patients with suspicious or malignant cytology underwent surgery. RESULTS: Of the 349 nodules undergoing surgery, 284 were malignant. The prevalence of cancer was slightly higher in nodules>or=10 mm in diameter vs. those<10 mm (5.5% vs. 3.0%, p<0.01). However, histological type and local aggressiveness were largely independent of nodule size. Microcalcifications (72.2% vs. 28.7%; p<0.001; OR 6.4, 95%CI 4.9-8.4), blurred margins (52.8% vs. 18.8%; p<0.001; OR 4.8, 95%CI 3.8-6.1), solid hypoechoic appearance (80.6% vs. 52.4%; p<0.001; OR 3.8, 95%CI 2.8-5.1), size>or=10 mm (77.4% vs. 64.9%; p<0.001; OR 1.9, 95%CI 1.4-2.5) and intranodular vascular pattern type 2 (61.6% vs. 49.7%; p<0.001; OR 1.6, 95%CI 1.2-2.0) were all significantly more frequent in malignant than in benign nodules. These associations were similar when large and small nodules were analysed separately. DISCUSSION: No single parameter, including nodule size, satisfactorily identifies a subset of patients to be electively investigated by FNAC, although several may be useful in this regard.

Biopsy, Fine-Needle↗

Computer-simulated lung nodules in digital chest radiographs for detection studies.

Computer simulations of lung nodules overcome many shortcomings of creating radiographs using anthropomorphic nodule phantoms for lung nodule detection studies, but these algorithms can be cumbersome and involved. A simple, fast, and flexible computer program to simulate lung nodules in digital chest radiographs for detection studies is reported. To verify the realism of the simulated nodules, a psychophysical study and a statistical study were conducted. In the psychophysical study, six radiologists and four nonradiologists were asked to distinguish between 17 real lung nodules and 17 computer-simulated lung nodules shown in eight radiographs. The results show that the computer-simulated lung nodules are indistinguishable visually from real lung nodules. Using parameters from the Rose model of vision, results show that the simulated and real nodules are the same statistically. Thus, besides visual validity, statistical analysis in confirming the validity of the simulated lung nodules is included.

Computer Simulation↗

Clonality of thyroid nodules in sporadic goiter.

Clonality studies have suggested that neoplasms are monoclonal and hyperplasias are polyclonal. To investigate this question in thyroid, we analyzed the clonality of 26 morphologically characterized hyperplastic nodules from 19 patients with sporadic goiters. For comparison we studied six thyroid carcinomas. We used the highly informative M27 beta probe that maps to the X-chromosome DXS255 locus (X cen-p11.22). Material was obtained from 52 nodules; tissue from nine nodules was rejected because of contamination with normal elements, five patients (eight nodules) were homozygous at Pst I sites in nonnodular thyroid tissue, and three nodules were excluded for technical reasons. Methylation patterns after Hpa II digestion confirmed polyclonality in all nontumorous thyroids of informative patients. Seven hyperplastic nodules were polyclonal, and 18 were monoclonal; one showed loss of heterozygosity. One nodule exhibited aberrant methylation. Multiple nodules were obtained from four patients; in three, all were monoclonal with activation of the same allele. Three papillary carcinomas were monoclonal; two exhibited aberrant methylation. One follicular carcinoma showed loss of heterozygosity. Our data indicate that morphologically indistinguishable hyperplastic thyroid nodules may be monoclonal or polyclonal. These findings suggest that variable molecular mechanisms are involved in the pathogenesis of nodules in sporadic goiter. Future studies will need to explore the biological significance of nodules of variable clonal origin.

Adult↗

Automatic detection of small lung nodules on CT utilizing a local density maximum algorithm.

Increasingly, computed tomography (CT) offers higher resolution and faster acquisition times. This has resulted in the opportunity to detect small lung nodules, which may represent lung cancers at earlier and potentially more curable stages. However, in the current clinical practice, hundreds of such thin-sectional CT images are generated for each patient and are evaluated by a radiologist in the traditional sense of looking at each image in the axial mode. This results in the potential to miss small nodules and thus potentially miss a cancer. In this paper, we present a computerized method for automated identification of small lung nodules on multislice CT (MSCT) images. The method consists of three steps: (i) separation of the lungs from the other anatomic structures, (ii) detection of nodule candidates in the extracted lungs, and (iii) reduction of false-positives among the detected nodule candidates. A three-dimensional lung mask can be extracted by analyzing density histogram of volumetric chest images followed by a morphological operation. Higher density structures including nodules scattered throughout the lungs can be identified by using a local density maximum algorithm. Information about nodules such as size and compact shape are then incorporated into the algorithm to reduce the detected nodule candidates which are not likely to be nodules. The method was applied to the detection of computer simulated small lung nodules (2 to 7 mm in diameter) and achieved a sensitivity of 84.2% with, on average, five false-positive results per scan. The preliminary results demonstrate the potential of this technique for assisting the detection of small nodules from chest MSCT images.

Algorithms↗

Smoking is a strong risk factor for rheumatoid nodules in early rheumatoid arthritis.

OBJECTIVE: To examine whether smoking is a risk factor for rheumatoid nodules in early rheumatoid arthritis, and if so to determine the quantitative effect of smoking. METHODS: From a cohort (n = 1589) in a structured programme for follow up of newly diagnosed cases of rheumatoid arthritis (symptoms of swollen joints < or =12 months), 112 individuals with rheumatoid nodules at inclusion were identified. Nodular patients were each compared with two age and sex matched controls without nodules from the same cohort. A detailed self administered tobacco use questionnaire was answered by 210 patients (63%). RESULTS: Seventy patients were current smokers, 71 former smokers, and 69 had never smoked. Current smoking and former smoking were more common in patients with rheumatoid nodules compared with controls (86% v 59%) in both sexes. Positive rheumatoid factor (RF) was found more often among cases with nodules than controls (78% v 64%). Using detailed information from the questionnaires with conditional logistic regression analyses, ever having smoked was associated with an increased risk of the presence of rheumatoid nodules (odds ratio (OR) = 7.3 (95% confidence interval, 2.3 to 23.6); p = 0.001). The risk of having nodules was not obviously dose dependent when smoking duration as well as smoking amount were examined. A stratified analysis showed that only RF positive smokers had an increased risk of rheumatoid nodules. Smoking was associated with rheumatoid nodules among both men (p = 0.006) and women (p = 0.001). Tobacco use other than smoking (n = 31) was not associated with an increased risk of nodules (OR = 0.8 (0.2 to 3.4); p = 0.813). CONCLUSIONS: There is a strong association between smoking and rheumatoid nodules in early seropositive rheumatoid arthritis.

Adult↗

Benign rheumatoid nodules in a woman with chronic lymphocytic leukaemia and borderline lepromatous leprosy.

OBJECTIVES: To report benign rheumatoid nodules in a woman with chronic lymphocytic leukaemia and borderline lepromatous leprosy and to summarise the features of the patients with adult onset benign rheumatoid nodules. METHODS: A 66 year old woman with chronic lymphocytic leukaemia and borderline lepromatous leprosy who presented with subcutaneous elbow nodules, which were at first suspected to represent either progression of her haematological disease or leprosy, is described. The clinical characteristics of our patient and previous reports of another 24 subjects with adult onset benign rheumatoid nodules are reviewed. RESULTS: Biopsy of the patient's subcutaneous lesion disclosed the histopathology of a rheumatoid nodule; serological and clinical evaluations for rheumatoid arthritis and other rheumatoid nodule associated systemic diseases were negative. Adult onset benign rheumatoid nodules are clinically and histologically identical to those found in patients with rheumatoid arthritis. They often appeared in women during their 20s, frequently resolved spontaneously or were adequately treated by excision, and recurred in about one third of patients. The lesions were located in the ocular adnexa in 60% of patients. The most common lesional sites in patients with non-ocular benign rheumatoid nodules were the elbows, feet, and knees. None of these patients subsequently developed rheumatoid arthritis or other rheumatoid nodule associated diseases during follow up periods of as long as 20 years. CONCLUSION: The appearance of subcutaneous nodules is often the harbinger of an associated systemic disorder. Although benign rheumatoid nodules occur infrequently in adults, they should be considered in the differential diagnosis of new nodular lesions.

Adult↗

Cell death by apoptosis is a feature of the rheumatoid nodule.

OBJECTIVE: To examine the site and extent of apoptosis in the rheumatoid nodule and to determine whether this process make a significant contribution to the control of inflammation in the rheumatoid nodule as in other granulomas. METHODS: Nine nodules and seven synovial membranes were examined by terminal deoxynucleotidyl transferase-mediated nick end labelling (TUNEL) in situ and a subset was further examined by DNA electrophoresis. The phenotype of apoptotic cells was identified using monoclonal antibodies and immunohistology. RESULTS: Apoptosis occurred in all zones of the nodule and, except in one case, was not focused adjacent to the necrotic centre. Apoptosis occurred in 3.5 (4.5)% (mean (SD)) of cells in the nodule and 3.6 (3.1)% of cells in synovial membranes. Apoptosis was more common in nodule T cells (4.1 (2.9)%) than fibroblasts (1.0 (1.4)%), p = 0.01. Among macrophages 3.2 (4.7)% were apoptotic. Banding of DNA consistent with apoptosis was seen in two of three nodules examined. CONCLUSION: Apoptosis occurs at a low level in the nodule, similar to the synovial membrane. The results suggest that two modes of cell death occur in the nodule: apoptosis, which occurs throughout the nodule; and necrosis, which is concentrated near the necrotic centre. Apoptosis was more common in infiltrating inflammatory cells than in resident fibroblasts. These results are consistent with the proposal that apoptosis of infiltrating inflammatory cells is important in controlling accumulation of cells in the rheumatoid nodule as has been established in experimental granulomas.

Adult↗

Pulmonary nodules detected at lung cancer screening: interobserver variability of semiautomated volume measurements.

PURPOSE: To retrospectively determine interobserver variability of semiautomated volume measurements of pulmonary nodules and the potential reasons for variability. MATERIALS AND METHODS: The Dutch-Belgian lung cancer screening trial (NELSON) is a lung cancer screening study that includes men between the ages of 50 and 75 years who are current or former heavy smokers. The NELSON project was approved by the Dutch Ministry of Health and the ethics committee of each participating hospital. Informed consent was obtained from all participants. For this study, the authors evaluated 1200 consecutive low-dose computed tomographic (CT) scans of the chest obtained during the NELSON project and identified subjects who had at least one 50-500-mm(3) nodule. One local and one central observer independently evaluated the scans and measured the volume of any detected nodule by using semiautomated software. Noncalcified solid nodules with volumes of 15-500 mm(3) were included in this study if they were fully surrounded by air (intraparenchymal) and were detected by both observers. The mean volume and the difference between both measurements were calculated for all nodules. Intermeasurement agreement was assessed with the Spearman correlation coefficient. Potential reasons for discrepancies were assessed. RESULTS: There were 232 men (mean age, 60 years; age range, 52-73 years) with 430 eligible nodules (mean volume, 77.8 mm(3); range, 15.3-499.5 mm(3)). Interobserver correlation was high (r = 0.99). No difference in volume was seen for 383 nodules (89.1%). Discrepant results were obtained for 47 nodules (10.9%); in 16 cases (3.7%), the discrepancy was larger than 10%. The most frequent cause of variability was incomplete segmentation due to an irregular shape or irregular margins. CONCLUSION: In a minority (approximately 11%) of small solid intraparenchymal nodules, semiautomated measurements are not completely reproducible and, thus, may cause errors in the assessment of nodule growth. For small or irregularly shaped nodules, an observer should check the segmentation shown by the program.

Aged↗

Lung nodules: dual-kilovolt peak analysis with CT--multicenter study.

PURPOSE: To test the following hypothesis: The greater the increase in the mean computed tomographic (CT) number of a radiologically indeterminate lung nodule from the CT number on a 140-kVp CT image to that on an 80-kVp CT image, the more likely the nodule is benign (ie, contains calcium). MATERIALS AND METHODS: Two hundred forty indeterminate lung nodules were prospectively studied at four institutions: Mayo Clinic Scottsdale, Ariz (n = 160); Mayo Clinic Rochester, Minn (n = 50); Shiga Health Insurance Hospital, Otsu, Japan (n = 25); and Duke University Medical Center, Durham, NC (n = 5). Of the 240 nodules, 157 met the entrance criteria for this study and had a diagnosis. All nodules included were solid, 5-40-mm diameter, relatively spherical, homogeneous, and without visible evidence of calcification or fat. Each nodule was evaluated by using 3-mm-collimation, nonenhanced CT scans with both 140- and 80-kVp x-ray beams. RESULTS: There were 86 (55%) benign and 71 (45%) malignant nodules. The median increase in the nodule mean CT number from the CT number on 140-kVp images to that on 80-kVp images was 2 HU for benign nodules and 3 HU for malignant nodules. This difference was not statistically significant. The area under the receiver operating characteristic curve was 0.505. CONCLUSION: Dual-kilovolt peak analysis with current CT technology does not appear to be helpful in the identification of benign lung nodules.

Adult↗

Small pulmonary nodules: volumetrically determined growth rates based on CT evaluation.

PURPOSE: To determine the accuracy of high-resolution computed tomographic (CT) volumetric measurements of small pulmonary nodules to assess growth and malignancy status. MATERIALS AND METHODS: The accuracy of three-dimensional (3D) image extraction and isotropic resampling techniques was assessed by performing three experiments. The first experiment measured volumes in spherical synthetic nodules of two diameters (3.20 and 3.96 mm), the second measured deformable silicone synthetic nodules prior to and after their shape had been altered markedly, and the third measured nodules of various shapes and sizes. Three-dimensional techniques were used to assess growth in 13 patients for whom the final diagnosis was known and whose initial nodule diameters were less than 10 mm. By using the exponential growth model and the calculated nodule volume at two points in time, the doubling time for each subject was calculated. RESULTS: The three synthetic nodule studies revealed that the volume could be measured accurately to within +/-3%. All five malignant nodules grew, and all had doubling times less than 177 days. Some malignant nodules had asymmetric patterns of growth identified by using the 3D techniques but not the two-dimensional methods. All eight benign nodules had doubling times of 396 days or greater or showed a decrease in volume. CONCLUSION: CT volumetric measurements are highly accurate for determining volume and are useful in assessing growth of small nodules and calculating their doubling times.

Aged↗

Fine needle aspiration of thyroid nodules. Determinants of insufficiency rate and malignancy yield at thyroidectomy.

OBJECTIVE: To evaluate patient- and practice-specific determinants of the thyroid nodule fine needle aspiration (FNA) insufficiency rate and malignancy yield at a tertiary-care teaching hospital. STUDY DESIGN: All FNAs of thyroid nodules performed from August 1990 to October 1993 at the Walter Reed Army Medical Center Endocrinology Clinic were reviewed and the results analyzed for correlation with surgical outcome, scintiscanning result and operator experience. Provider-specific factors influencing the FNA insufficiency rate, surgical referral pattern and malignancy yield were evaluated. RESULTS: A total of 504 aspirations in 422 patients with thyroid nodules were included in the analysis. The sensitivity of FNA for detecting malignancy was 80%, specificity was 73.2%, and accuracy was 75.2%. A significant negative correlation was found between recent aspirator experience and the insufficiency rate. Repeat aspiration of nodules previously yielding benign cytology increased the malignancy yield. Surgical excision of nodules with insufficient aspirations gave a low malignancy yield, and aspiration of nodules that were "hot" on scintiscanning rarely yielded false positive FNA results. CONCLUSION: Specific limitations of thyroid nodule FNA include a large number of aspirates containing insufficient cytologic material and a variable malignancy yield. Specific recommendations based on the findings in this report are: the establishment of uniform criteria for judging specimen adequacy, the performance of repeat aspiration on thyroid nodules with previously benign aspirates, the abandonment of scintiscanning in the routine management of thyroid nodules and a conservative approach to clinically indolent nodules repeatedly found to have scant cellularity on FNA. Based on these findings, an algorithm for the diagnostic evaluation of a solid thyroid nodule can be constructed.

Adolescent↗

Thyroid nodules in the follow-up of irradiated individuals: comparison of thyroid ultrasound with scanning and palpation.

In 1974 we began a prospective study of a cohort of 4296 individuals exposed to therapeutic head and neck irradiation during childhood for benign conditions. To define the role of thyroid ultrasonography in following irradiated individuals, we studied a subgroup of 54 individuals. They all had been screened between 1974-1976 and had normal thyroid scans and no palpable nodules at that time. Thyroid ultrasonography, thyroid scanning, physical examination, and serum thyroglobulin measurements were performed. One or more discrete ultrasound-detected nodules were present in 47 of 54 (87%) subjects. There were a total of 157 nodules, 40 of which were 1.0 cm or larger in largest dimension. These 40 nodules occurred in 28 (52%) of the subjects. Thirty (75%) of these 1.0-cm or larger nodules matched discrete areas of diminished uptake on corresponding thyroid scans. The 10 that did not match (false negative scans for > or = 1.0-cm nodules) were the only nodules of this size in 7 subjects. Of 11 nodules 1.5 cm or larger, only 5 were palpable. Serum thyroglobulin correlated to the number (P = 0.04; r2 = 0.10), but not the volume of the thyroid nodules (P = 0.07; r2 = 0.08). We conclude that thyroid nodules are continuing to occur and are exceedingly common in this irradiated cohort of individuals. The results confirm that thyroid ultrasonography is more sensitive than physical examination and scanning. However, thyroid ultrasound is so sensitive and nodules so prevalent that great caution is needed in interpreting the results.

Child↗

Managing the small pulmonary nodule discovered by CT.

OBJECTIVES: To review the Early Lung Cancer Action Project experience and the medical literature from 1993 to 2003 on detection of the small, noncalcified pulmonary nodule by CT in order to formulate a management algorithm for these nodules. DESIGN: Prospective noncomparative study of smokers without prior malignancy and a review of the medical literature of CT screening of lung cancer. INTERVENTIONS: Chest CT and, where appropriate, CT observation for nodule growth, antibiotics, CT-guided fine-needle aspiration (FNA) biopsy, fiberoptic bronchoscopy, and video-assisted thoracoscopic surgery (VATS). RESULTS: The following factors influence the probability of malignancy in a CT-detected, small, noncalcified pulmonary nodule: size, change in size, age, smoking history, density, number of nodules, gender, circumstance of the CT, spirometry, occupational history, and endemic granulomatous disease. The two diagnostic techniques most useful in evaluating the CT-detected, small, noncalcified nodule are short-term observation of nodule growth by CT and CT-guided FNA. Due to small nodule size and the frequent finding of nonsolid or part-solid nodules, positron emission tomography, fiberoptic bronchoscopy, and VATS were less useful. CONCLUSIONS: Pulmonologists are frequently asked to evaluate the CT-detected, small, noncalcified nodule invisible on standard chest radiography. Immediate biopsy is justified if the likelihood of cancer is high, but if that likelihood is low or intermediate, a period of observation by CT is appropriate. VATS or thoracotomy are rarely necessary for a diagnosis of lung cancer in the CT-detected small pulmonary nodule.

Adult↗

Hot nodules in children and adolescents in western Poland from 1996 to 2000: clinical analysis of 31 patients.

In an iodine deficient area, a high incidence of hot thyroid nodules was observed in children after the introduction of iodine supplementation in 1997. Thirty-one children (28 girls, 3 boys) were identified with hot nodules between the years 1996-2000 (3 patients in 1996, 4 in 1997, 10 in 1998, 7 in 1999, and 7 in 2000). The incidence ratio of hot nodules in this study population increased significantly from 0.23 in 1996 to 0.80 in 1998. In 17 children, radionuclide uptake was confined exclusively to areas corresponding to the nodules. Cancer was detected in one child in post-operative histological examination. In the other 14 children, the predominant uptake was in nodules, but it was also registered within extranodular tissue. In the latter group, eight tumors were eventually diagnosed as cancer and six as benign tumors. The majority of tumors in the entire group was located in the right lobe (19/31) and was accompanied by reduced TSH levels (23/31), but only 14 of the 31 patients had signs of hyperthyroidism. The years 1996-2000, in which the increase in the incidence of "hot" nodules in children with nodular goiter was observed, correspond to a period of enforced salt iodinization. The existence of cancer within hot nodules is rare, ranging from 2-5% of all nodules. By contrast, the risk of cancer in hot nodules in the cohort of this study was significantly higher (9/31; 29.0%), especially in cases of hot nodules with a rudimentary radionuclide uptake in the extranodular area. We conclude that, in geographical regions affected with iodine deficiency, the therapeutic protocol for children with hot nodules should be based primarily on surgery rather than on radioiodine.

Adolescent↗

CT evaluation of solitary pulmonary nodules: value of 185-H reference phantom.

The pulmonary nodule CT reference phantom is widely used in the evaluation of nodules 2 cm or less in diameter. It is used to detect benign patterns of calcification that are not visible on thin-section CT scans. Since 1986, the reference nodules have been manufactured with a nominal composition of 185 H. The multicenter study published in 1986 used nodules with a nominal composition of 264 H, 100 H more than the threshold value reported by Siegelman et al. in 1980. In the multicenter study, one of 37 nodules diagnosed as benign with the phantom proved to be malignant. The purpose of this study was to determine the misdiagnosis rate with the 185-H phantom and to ascertain whether the malignant tumors predicted to be benign actually contained calcification. We retrospectively reviewed 296 cases in which examinations had been performed with the 185-H nodules since 1986. Eighty-five nodules were diagnosed as benign by comparison to the reference phantom. These 85 contained no visible calcification on thin-section CT scans. Ten of the 85 cases were shown to be malignant tumors. Eight were diagnosed as having a high probability of benignity. Two were diagnosed as having a moderate probability of benignity. Calcium was present in the tissue of all six nodules available for review. Fifty-nine of the 85 nodules were still clinically indeterminate at the time of this review. Even if all of the clinically indeterminate nodules are benign, the misdiagnosis rate would be significantly higher than in most previous studies. Although analysis by using the reference phantom with 185-H nodules may indicate a high probability of benignity, close radiologic follow-up is necessary.

Adult↗

Radiologists' performance for differentiating benign from malignant lung nodules on high-resolution CT using computer-estimated likelihood of malignancy.

OBJECTIVE: The purpose of our study was to evaluate whether a computer-aided diagnosis (CAD) scheme can assist radiologists in distinguishing small benign from malignant lung nodules on high-resolution CT (HRCT). MATERIALS AND METHODS: We developed an automated computerized scheme for determining the likelihood of malignancy of lung nodules on multiple HRCT slices; the likelihood estimate was obtained from various objective features of the nodules using linear discriminant analysis. The data set used in this observer study consisted of 28 primary lung cancers (6-20 mm) and 28 benign nodules. Cancer cases included nodules with pure ground-glass opacity, mixed ground-glass opacity, and solid opacity. Benign nodules were selected by matching their size and pattern to the malignant nodules. Consecutive region-of-interest images for each nodule on HRCT were displayed for interpretation in stacked mode on a cathode ray tube monitor. The images were presented to 16 radiologists-first without and then with the computer output-who were asked to indicate their confidence level regarding the malignancy of a nodule. Performance was evaluated by receiver operating characteristic (ROC) analysis. RESULTS: The area under the ROC curve (Az value) of the CAD scheme alone was 0.831 for distinguishing benign from malignant nodules. The average Az value for radiologists was improved with the aid of the CAD scheme from 0.785 to 0.853 by a statistically significant level (p = 0.016). The radiologists' diagnostic performance with the CAD scheme was more accurate than that of the CAD scheme alone (p < 0.05) and also that of radiologists alone. CONCLUSION: CAD has the potential to improve radiologists' diagnostic accuracy in distinguishing small benign nodules from malignant ones on HRCT.

Diagnosis, Differential↗